Pin No. DB-25
10
Description
1 Speed Control Voltage Input (0-10 V)
2 Speed Control Current Input (0-20 mA)
3 Speed Control Input Ground Return
4 Speed Signal Current Output (0-20 mA)
5 Speed Signal Output Ground Reference
6 (Motor Running N.O. Default) 1A @24V (Open Collector)
7 Motor Running Ground Return
8 (Motor Running N.C. Default) 1A @24V (Open Collector)
14 Speed Signal Voltage Output (0-10 V)
15 Remote Start/Stop Input
16 Remote CW/CCW Input
17 Remote Start/Stop, CW/CCW, Prime Grnd Ref.
18 Tach Ground Reference
19 Tach Output (Open Collector)
20 Remote Prime Input
23 General Alarm Output
24 Local/Remote Indicator
9-12 Reserved - Not Used
21-22 Reserved - Not Used
25 Aux 24V+
13 Aux 24V-
Pin No.
DB-25
SAFETY
PRECAUTIONS
Explanation of
Symbols
WARNING:
Product Use
Limitation
DANGER: Remove power from the pump before any cleaning operation is started.
WARNINGS: Remove power from the pump before attempting any maintenance.
The Power switch on the Back Panel is not the main disconnect.
A contactor or other device that
routinely disconnects and reapplies the AC line to the drive to start and stop the motor can
cause drive hardware damage. The drive is designed to use control input signals that will start
and stop the motor.
Turn Pump System off before removing or installing Gear Pump. Fingers or loose clothing
could get caught in drive mechanism.
CAUTIONS: Replace the fuse only with one of the same type and rating. The fuse type and
rating are stated on the rear panel.
Power must be turned off before connecting the external remote control cable to prevent
damage to the drive.
CAUTIONS: To avoid electrical shock, the power cord protective grounding conductor
must be connected to ground. Not for operation in wet locations as defined by EN61010-1.
If the product is not used in a manner specified in the instructions, the protection provided
by the equipment may be impaired.
CAUTION: Risk of Danger. Consult Operator’s manual for nature of hazard and
corrective actions.
CAUTION: Risk of crushing. Keep fingers away from magnetic coupling while pump is in opera-
tion. Stop pump before mounting Gear Pump.
CAUTION: Risk of electric shock. Consult Operator’s manual for nature of hazard and
corrective actions.
This product is not designed for, nor intended for use in patient connected
applications; including, but not limited to, medical and dental use, and accordingly
has not been submitted for FDA approval.
This product is not designed for, nor intended for use in hazardous duty areas as
defined by ATEX or the NEC (National Electrical Code); including but not limited to
use with flammable liquids.
50001-60
50001-62
50001-64
50001-68
50001-69
50001-70
50001-72
50001-74
50001-76
50001-78
—
Italy
U.S. 230V
—
Israel
Europe
England
Switzerland
Replacement Cord/Plug Sets Ordering Information
Catalog
number
Description DescriptionDescription Catalog
number
Catalog
number
PUMP CAL
CAL DE LA BOMBA
CALIBRAGE
PUMPENKAL
TARATURA POMPA
FLOW RATE
CAUDAL
DÉBIT
DURCHFLUSSRATE
INDICE DI FLUSSO
Australia
Denmark
India
U.S. STD. 115V
夏校准
ホソブサイズ