Jun. 2023
03
Version
Metric SAE
W
H
A
L
ØD
N-m
L
NTP-30N
NTP-110N
NTP-210N
NTP-350N
NTP-500N
NTP-700N
NTP-980N
NTP-1500N
NTP-2000N
1/4”
3/8”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
1”
1”
0.2 Nm
0.5 Nm
1 Nm
1 Nm
2.5 Nm
2.5 Nm
7 Nm
10 Nm
10 Nm
6-30 Nm
20-110 Nm
40-210 Nm
70-350 Nm
100-500 Nm
140-700 Nm
140-980 Nm
300-1500 Nm
400-2000 Nm
0.74
0.96
1.70
2.54
3.66
5.94
6.46
11.19
13.61
295
380
535
650
860
1090
1230
1750
2181
W
28.2
36.3
46.7
47.5
72.0
72.0
72.0
83.5
83.5
H
20.3
23.6
27.7
33.3
37.3
51.5
51.5
51.5
57.0
72.3
72.3
B
9.0
12.4
12.6
15.2
16.8
23.6
24.0
24.1
28.5
30.6
30.6
20.3
23.6
27.7
33.3
37.3
51.5
51.5
51.5
57.0
72.3
72.3
9.0
12.4
12.6
15.2
16.8
23.6
24.0
24.1
28.5
30.6
30.6
ØD
35.0
35.0
40.0
47.0
47.0
47.0
47.0
40.0
40.0
KG
A
L
NTP-250i
NTP-80F
NTP-150F
NTP-250F
NTP-300F
NTP-600F
NTP-700F
NTP-1000F
NTP-1500F
1/4”
3/8”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
1”
1”
1 in.lb
0.5 ft.lb
1 ft.lb
1 ft.lb
2.5 ft.lb
2.5 ft.lb
5 ft.lb
5 ft.lb
5 ft.lb
40-250 in.lb
15-80 ft.lb
30-150 ft.lb
50-250 ft.lb
50-300 ft.lb
100-600 ft.lb
100-700 ft.lb
200-1000 ft.lb
300-1500 ft.lb
0.74
0.96
1.70
2.54
3.66
5.94
6.46
11.19
13.61
295
380
535
650
860
1090
1230
1750
2181
W
28.2
36.3
46.7
47.5
72.0
72.0
72.0
83.5
83.5
HBØD
35.0
35.0
40.0
47.0
47.0
47.0
47.0
40.0
40.0
KG
A
ITEM NO. Range ITEM NO. Range
Unit : mm
Accuracy : C.W.±4%
For example : ITEM NO. NTP-210N
To set torque to 135 Nm. Firstly pull the lock ring and turn
the handle clockwise until the upper edge to 130 Nm (see A)
and the reading “5” on the long tube must align with the
center line of scale vertically so as to acquire 130+5=135 Nm.
(see B)
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
N-M
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
1 2 3
C
0
28
210
170
130
190
150
110
200
160
120
180
140
1. Pull the lock ring to unlocked.
2. Turn the adjustable handle clockwise or
counter-clockwise (Right or left) to set the desired torque.
3. Push the lock ring to set finished.
Unlock
Lock
Set
MAINTENANCE AND STORAGE
HOW TO SET TORQUE VALUE
TORQUE CONVERSION FACTORS
1. Please return torque value to the lowest reading when not in use. (see C) Do not turn below the lowest reading.
2. If this tool has not been used for a period of time, it shall be preloaded several times at its maximum torque setting.
This will allow internal lubricant to recoat.
3. Clean this tool by wiping with a clean cloth after operation and storage in a dry environment.
Do not dip any type of liquid in this tool. This may damage the internal of this tool.
4. This tool should be recalibrated a period of 12 months, or 5,000 cycles, whichever occurs first.
To contact with local vendor or an authorized repair center for supporting.
Units to be
converted
1 mN.m
1 cN.m
1 N.m
1 ozf.in
1 lbf.in
1 lbf.ft
1 gf.cm
1 kgf.cm(kp.cm)
1 kgf.m(kp.m)
1
10
1000
7.062
113
1356
0.098
98.07
9807
0.1
1
100
0.706
11.3
135.6
0.01
9.807
980.7
0.001
0.01
1
0.007
0.113
1.356
0.0001
0.098
9.807
0.142
1.416
141.6
1
16
192
0.014
13.89
1389
0.009
0.088
8.851
0.0625
1
12
0.0009
0.868
86.8
0.0007
0.007
0.738
0.005
0.083
1
0.00007
0.072
7.233
10.2
102
10197
72
1152.1
13826
1
1000
100000
0.01
0.102
10.2
0.072
1.152
13.83
0.001
1
100
0.0001
0.001
0.102
0.0007
0.0115
0.138
0.00001
0.01
1
=mN.m =cN.m =N.m =ozf.in =lbf.in =lbf.ft =gf.cm =kgf.cm
(kp.cm)
=kgf.m
(kp.m)
Corresponding unit
Conversion-formula :
Units to be converted × Factor = Corresponding unit
Example : Convert 5 lbf.ft into cN.m
Solution : 5 × 135.6 = 678 cN.m
170
190
160
180
170
190
200
160
180
AB
12 months
5000 cycles
SPECIFICATION
www.matatakitoyo.com Made in Taiwan
MATATAKITOYO TOOL CO., LTD.
No. 63, Ln. 493, Sec. 3, Zhongshan Rd., Tanzi Dist.,
Taichung City 42754, Taiwan
TEL : 886-4-2533 5893
Manufacturer