manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Meanwell
  6. •
  7. Power Supply
  8. •
  9. Meanwell DR-15-5 User manual

Meanwell DR-15-5 User manual

Installation Manual
Type:DR Family with Class II(Series:DR-15, DR-30, DR-60, DR-100)
DR-15-5 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 5V 2.4A
DR-15-12 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 12V 1.25A
DR-15-15 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 15V 1A
DR-15-24 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 24V 0.63A
DR-30-5 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 5V 3A
DR-30-12 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 12V 2A
DR-30-15 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 15V 2A
DR-30-24 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 24V 1.5A
DR-60-5 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 5V 6.5A
DR-60-12 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 12V 4.5A
DR-60-15 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 15V 4A
DR-60-24 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 24V 2.5A
DR-100-12 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 12V 7.5A
DR-100-15 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 15V 6.5A
DR-100-24 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 24V 4.2A
Introduction
DR with class II is a double insulated DIN rail power supply series, meaning it is ungrounded. Like other Mean Well’s
DIN series, they can be mounted on a TS35 Standard DIN rail.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top for DR-15, the input terminals on the right and output on the left for DR-30, DR-60, and DR-100.
Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
(3)Use stranded copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
6A
6-10A
13-16A
16-25A
Cross-section of
Lead(mm2)
0.75
1.00
1.5
2.5
Note:Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
Installation Manual
3
1
2
4
(4)Use wire that can withstand temperatures of at least 80°C such as UL1007.
(5)Recommended wire strapping length is 7mm/0.275inch.
(6)Recommended torque setting for terminals is 5 kgf-cm (4.4 Lb-in).
(7)Recommended screwdriver is 3mm, slotted type.
(8)Suggested fuse and maximum number of the DR classⅡPSUs that can be connected to a circuit breaker at
230V are shown as below.
Model
Fuse
Circuit breaker
C16
D16
DR-15
T2A/L250V
19
22
DR-30
F2A/L250V
7
15
DR-60
F3.15A/L250V
3
7
DR-100
F3.15A/L250V
3
6
(9)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(10)For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
(7)The maximum operating temperatures is 50°C for DR-15 and DR-30 series and 40°C for DR-60 and DR-100 series,
please do not install the unit in places with high ambient temperature or near fire source.
(8)Output current and output wattage must not exceed the rated values on its specification.
"Click"
Installation Manual
(9)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from supply
voltage. Make sure that inadvertent connection in circuit will be impossible!
(10)For continued protection against risk of fire, replace only with same type and rating of fuse.
Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même type
et de memes caractéristiques nominales.
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.

This manual suits for next models

14

Other Meanwell Power Supply manuals

Meanwell SDR Series User manual

Meanwell

Meanwell SDR Series User manual

Meanwell DR Series User manual

Meanwell

Meanwell DR Series User manual

Meanwell LCM-40(DA) User manual

Meanwell

Meanwell LCM-40(DA) User manual

Meanwell DRDN20 User manual

Meanwell

Meanwell DRDN20 User manual

Meanwell PWR24048 User manual

Meanwell

Meanwell PWR24048 User manual

Meanwell RCB-1600 Series User manual

Meanwell

Meanwell RCB-1600 Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell IRC1 User manual

Meanwell

Meanwell IRC1 User manual

Meanwell NMP650 User manual

Meanwell

Meanwell NMP650 User manual

Meanwell LCM-25KM User manual

Meanwell

Meanwell LCM-25KM User manual

Meanwell DR-RDN20 User manual

Meanwell

Meanwell DR-RDN20 User manual

Meanwell LCM-40KN User manual

Meanwell

Meanwell LCM-40KN User manual

Meanwell ELG-150-C Series User manual

Meanwell

Meanwell ELG-150-C Series User manual

Meanwell TDR-480-24 User manual

Meanwell

Meanwell TDR-480-24 User manual

Meanwell SHP-30K-HV Series User manual

Meanwell

Meanwell SHP-30K-HV Series User manual

Meanwell DDR-15G-3.3 User manual

Meanwell

Meanwell DDR-15G-3.3 User manual

Meanwell XLG-25 Series User manual

Meanwell

Meanwell XLG-25 Series User manual

Meanwell KNX-20E-640 User manual

Meanwell

Meanwell KNX-20E-640 User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell APV-25 User manual

Meanwell

Meanwell APV-25 User manual

Meanwell RCP-2000 User manual

Meanwell

Meanwell RCP-2000 User manual

Meanwell CSP Series User manual

Meanwell

Meanwell CSP Series User manual

Meanwell RSP-2400-12 User manual

Meanwell

Meanwell RSP-2400-12 User manual

Meanwell DDR-120A-12 User manual

Meanwell

Meanwell DDR-120A-12 User manual

Popular Power Supply manuals by other brands

Televes 502905 manual

Televes

Televes 502905 manual

Gallagher S100 instructions

Gallagher

Gallagher S100 instructions

Kramer VA-100P-5 user manual

Kramer

Kramer VA-100P-5 user manual

XS Power IntelliSUPPLY PSC30 user guide

XS Power

XS Power IntelliSUPPLY PSC30 user guide

ODROID SmartPower2 manual

ODROID

ODROID SmartPower2 manual

Valcom VP-624B user guide

Valcom

Valcom VP-624B user guide

Satel APS-412 manual

Satel

Satel APS-412 manual

ScienTECH ST4073 operating manual

ScienTECH

ScienTECH ST4073 operating manual

Thermaltake Toughpower 800W user manual

Thermaltake

Thermaltake Toughpower 800W user manual

Pulsar HPSB 3524C quick start guide

Pulsar

Pulsar HPSB 3524C quick start guide

Avocent Network Device SPC420 Specifications

Avocent

Avocent Network Device SPC420 Specifications

Global Specialties 1412 user manual

Global Specialties

Global Specialties 1412 user manual

Pulsar AWZ 251 manual

Pulsar

Pulsar AWZ 251 manual

Velleman PS1306 quick start guide

Velleman

Velleman PS1306 quick start guide

Delta Electronics GPS-300AB-9 Specifications

Delta Electronics

Delta Electronics GPS-300AB-9 Specifications

Pulsar PSCU 08348SEP manual

Pulsar

Pulsar PSCU 08348SEP manual

Sadelta SPS-2530D user manual

Sadelta

Sadelta SPS-2530D user manual

GMI D6014S instruction manual

GMI

GMI D6014S instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.