MG R7L-YS2 User manual

EM-7804-E Rev.6 P. 1 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
DC CURRENT OUTPUT MODULE, 2 points
(LONWORKS)MODEL R7L-YS2
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
DC current output module..................................................(1)
NeuronID label....................................................................(2)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LNS Plug-in Software (model: R7LPLG) is usable to set up
Functional Blocks. For detailed information, refer to the
R7PLG Users Manual. The R7LPLG is downloadable at our
web site.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V AC rating: 24V ±10%, 50/60 Hz, approx. 180mA
24V DC rating: 24V ±10%, approx. 110mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.

R7L-YS2
EM-7804-E Rev.6 P. 2 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
ERR SVCE
ONLINETX/RX
PWR
0123456789ABCD EF
4567
123
Reset SW Factory Configuration Port
Service SW
Status Indicator LED
Indicator LED
LONWORKS, Power Supply
Terminals Output Terminals
23415
10
789
6
■STATUS INDICATOR LED
ID COLOR STAT E MEANING
PWR Green ON Internal 5V is normal
OFF Internal 5V is abnormal.
ONLINE Green
ON Online
Blink
approx.
0.5 Hz
Offline
Sending/receiving of Net-
work
Variables has stopped.
Blink
approx.
2 Hz
Receiving Wink Message
OFF Abnormal state
ERR Red
ON Writing in the non-volatile
memory
Blink Abnormal state
OFF Normal state
TX/RX Green ON Sending/receiving Network
Variables
OFF Communication is lost.
SVCE Green
ON No network information
Blink
approx.
0.5 Hz
Offline
Sending/receiving of Net-
work
Variables has stopped.
OFF Normal state
■INDICATOR LED
Used to show network variable status assigned to fbLED.
ON : LED ON
OFF : LED OFF
■SERVICE SWITCH
Used to identify the node in LONWORKS network configura-
tion.
■RESET SWITCH
Used to reset the Neuron Chip. Press the switch behind the
front cover to reset.
Control functions are halted while completing resetting and
restarting. Confirm no danger before conducting resetting.
■POWER SUPPLY, LONWORKS TERMINAL ASSIGNMENT
4
NET1
5
NET2
6
U (+)
1
NET1
2
NET2
3
FG
7
V (
–
)
NO. ID FUNCTION, NOTES
1 NET1 LONWORKS communication 1
2 NET2 LONWORKS communication 2
3 FG FG
4 NET1 LONWORKS communication 1
5 NET2 LONWORKS communication 2
6 U (+) Power input
7 V (–) Power input
Note: LONWORKS wiring must be paired between NET1 termi-
nals and/or NET2 terminals.
■OUTPUT TERMINAL ASSIGNMENT
6
NC
7
I0
8
NC
1
NC
2
COM0
3
NC
9
I1
4
COM1
10
NC
5
NC
NO. ID FUNCTION NO. ID FUNCTION
1 NC No connection 6 NC No connection
2 COM0 Common 0 7 I0 Current 0
3 NC No connection 8 NC No connection
4 COM1 Common 1 9 I1 Current 1
5 NC No connection 10 NC No connection

R7L-YS2
EM-7804-E Rev.6 P. 3 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
23415
10
789
6
4567
123
30 (1.18) [5 (.20)]
3 (.12)5.5 (.22)
7–M3 SCREW
TERMINALS
for L
ON
W
ORKS
, POWER
10–M3 SCREW
TERMINALS
for OUTPUT
DIN RAIL
35mm wide
54 (2.13)
17 (.66)
6 (.24)
50 (1.97)
6 (.24)
18.5 (.73)
115 (4.53)
■CONNECTION DIAGRAM
4
7
6
3
2
5
1
V (–)
U (+)
FG
NET2
NET2
NET1
NET1
OUTPUT 0
LONWORKS
LONWORKS
EXTENSION CONNECTOR
7I0
2COM0
9
4
I1
COM1
OUTPUT 1
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd, Nichifu Co., Ltd
6 (.24) max
3.3 (.13) max
mm (inch)
COMMUNICATION CABLE CONNECTIONS
■HOST PC CONNECTION
HOST PC
LONWORKS
R7L
LONWORKS
R7L
LONWORKS
Terminator

R7L-YS2
EM-7804-E Rev.6 P. 4 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
DEVICE INTERFACE FILE
Device Interface File (XIF) is used to define a LONWORKS device when programmed on LonMaker.
For this module, the following file is used:
R7L-YS2v110.XIF
The XIF files are downloadable at our web site.
FUNCTIONAL BLOCKS
■NodeObject
NodeObject (Object ID : 0)
nv 0 nviRequest
SNVT_obj_request nv 1 nvoStatus
SNVT_obj_status
nv 2 nvoFileDirectory
SNVT_address
nv 3 nvoABNLCond
SNVT_state
SCPTdirection
SCPTmaxSendTime[ ]
SCPTminSendTime[ ]
SCPTlocation
SCPToemType
SCPTserialNumber
Extension module setting
Maximum sending time (per fb)
Minimum sending time (per fb)
Set Tag No. (name)
Indicate Model No. and Version
Indicate Serial No.
NodeObject :
Network Variables
Configuration Properties
• Network Variables
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviRequest {SNVT_obj_request} For use with LonMaker and other tools.
nvoStatus {SNVT_obj_status} For use with LonMaker and other tools.
nvoFileDirectory {SNVT_address} For use with LonMaker and other tools.
Required to get access to Configuration Properties.
nvoABNLCond {SNVT_state}
Shows the device status (All 0s in normal conditions).
Bit 0 through Bit 9 : Invalid
Bit 10 : E2PROM Configuration Property check sum error
Bit 11 : E2PROM Count data check sum error
(Bit 10 and Bit 11 can be reset to 0 by RQ_CLEAR_STATUS against NodeObject.)
Bit 12 through Bit 15 : Invalid

R7L-YS2
EM-7804-E Rev.6 P. 5 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTdirection ----
{SNVT_state}
{0 or 1}
{0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0}
Bit 0, Bit 1: Setting the extension module (Power supply
must be reset when this configuration property is changed.)
0,0 : Without extension module
1,0 : Discrete input (fb and other settings assigned to the 9th
and following points are invalid with 8-point input module.)
0,1 : Discrete output (fb and other settings assigned to the
9th and following points are invalid with 8-point output
module.)
Set this property before an extension module is connected.
Bit 2 through Bit 15 : Invalid
SCPTmaxSendTime
[Number of fb] ----
{SNVT_time_sec}
{0.0,10.0...3600.0}
{0.0}
Maximum time interval to send network variables (per fb).
(Power supply must be reset when this configuration prop-
erty is changed.)
Network variables are sent out in the specified intervals
even when there is no change in the value.
No sending when a value less than 10.0 is set.
Invalid property when the assigned fb has no network vari-
ables to be sent to the network.
SCPTminSendTime
[Number of fb] ----
{SNVT_time_sec}
{0.0,0.2...3600.0}
{1.0}
Minimum time interval to send network variables (per fb).
(Power supply must be reset when this configuration prop-
erty is changed.)
Network variables are sent out in the specified intervals
even when there are changes in the value faster than the
interval.
No sending when a value less than 0.2 is set.
Invalid property when the assigned fb has no network vari-
ables to be sent to the network.
SCPTlocation ----
{SNVT_str_asc}
{30-character string}
{“”}
Used to write Tag No. (name)
SCPToemType ---- {SNVT_str_asc}
{
e.g. “R7L-YS2_VER:0.10”
}Used to indicate Model No. and Version
SCPTserialNumber ---- {SNVT_str_asc}
{e.g. “ZZ123456”} Used to indicate Serial No.

R7L-YS2
EM-7804-E Rev.6 P. 6 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbCNT[0...7]
fbCNT[0...7] (Object ID : 17...24)
nv 36
...nv 43
nviCNTIn
SNVT_switch
nv 44
...nv 51
nviCNTCtrl
SNVT_switch
nv 52
...nv 59
nvoCNTOut
SNVT_count_32
SNVT_count_f
Set the initial value at nviCNTCtrl at the startup
Set count logic (ON or OFF)
Set operating mode
Set network variable type nvoCNTOut
Set the maximum count
Set the value when fbCNT[ ] is reset
fbCNT[ ] :
SCPTdirection
nviCNTIn :
SCPTinvrtOut
nviCNTCtrl :
SCPTpwrUpState
nvoCNTOut :
SCPTnvType
SCPTmaxRnge
SCPTsetpoint
Network Variables
Configuration Properties
• Network Variables
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviCNTIn
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Counted object
nviCNTCtrl
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Controls operation of fbCNT
0.0 0 : Stop counting
100.0 1 : Start counting
Invalid : Reset count value
nvoCNTOut
{SNVT_count_32}
{0...999 999 999}
{0}
{SNVT_count_f}
{0...999 999}
{0}
Number of ON counts or accumulated time of ON status at nviCNTIn or
the input terminal

R7L-YS2
EM-7804-E Rev.6 P. 7 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTdirection ----
{SNVT_state}
{0 or 1}
{0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0}
Bit 0 through 4: Counted object
0,0,0,0,0 : nviCNTIn
1,0,0,0,0 : ExX0
0,1,0,0,0 : ExX1
1,1,0,0,0 : ExX2
0,0,1,0,0 : ExX3
1,0,1,0,0 : ExX4
0,1,1,0,0 : ExX5
1,1,1,0,0 : ExX6
0,0,0,1,0 : ExX7
1,0,0,1,0 : ExX8
0,1,0,1,0 : ExX9
1,1,0,1,0 : ExXA
0,0,1,1,0 : ExXB
1,0,1,1,0 : ExXC
0,1,1,1,0 : ExXD
1,1,1,1,0 : ExXE
0,0,0,0,1 : ExXF
ExX0 through ExXF: Extension discrete input
Bit 6: Count function
0 : Number of status changes from OFF to ON
1 : Accumulated time of ON status
Bit 7: Memory storage at the non-volatile memory
0 : Count retained in the memory and preset at the startup
1 : Count always reset to 0
Bit 5, 8 through 15 : Invalid
Minimum input pulse width 500 ms for nviCNTIn, 50 ms
for the input terminals.
DO NOT connect a network variable to nviCNTIn when one
of the input terminals (other than nviCNTIn) is assigned as
the counted object.
ON time per 1 second increments.
SCPTinvrtOut nviCNTIn
{SNVT_lev_disc}
{ST_OFF, ST_ON}
{ST_OFF}
Count logic at nviCNTIn.
ST_OFF : Count with nvoCNTIn = ON
ST_ON : Count with nvoCNTIn = OFF
SCPTpwrUpState nviCNTCtrl
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{100.0 1}
Set value applied at nviCNTCtrl when the power supply is
turned on.
0.0 0 : Stop counting
100.0 1 : Start counting
Invalid : Reset count value
SCPTnvType nvoCNTOut
{SNVT_nv_type}
{}
{SNVT_count_32}
Indicates nvoCNTOut type.
For use with LonMaker and other tools.
SCPTmaxRnge nvoCNTOut
Same as nvoCNTOut.
Default = Max. range value
available for the type
Maximum count for nvoCNTOut. Count reset to 0 and
restarted at overflow.
SCPTsetpoint nvoCNTOut
Same as nvoCNTOut.
Default = Max. range value
available for the type
Set value applied at nvoCNTOut when fbCNT[ ] is Over-
Ride.

R7L-YS2
EM-7804-E Rev.6 P. 8 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbYS[0,1]
fbYS [0,1] (Object ID : 25, 26)
nviYSVal
SNVT_lev_percent
0% and 100% setpoints
Zero adjustment
Span adjustment
nviYSVal :
SCPTsetpoint [ ]
SCPToffset
SCPTgain
Network Variables
Configuration Properties
DC current output Output 0, Output 1
nv 60,
nv 61
• Network Variables
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviYSVal
{SNVT_lev_percent}
{-15.000...115.000}
{0.0}
% input proportional to the current at Output 0 and 1.
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTsetpoint[0] nviYSVal
{SNVT_lev_percent}
{-15.000...115.000}
{0.0}
nviYSVal lower range current in % of the output range.
SCPTsetpoint[0] < SCPTsetpoint[1]
SCPTsetpoint[1] nviYSVal
{SNVT_lev_percent}
{-15.000...115.000}
{100.0}
nviYSVal upper range current in % of the output range.
SCPTsetpoint[0] < SCPTsetpoint[1]
SCPToffset nviYSVal
{SNVT_lev_percent}
{-15.000...115.000}
{0.0}
nviYSVal zero (offset) adjustment.
Added to the calculation result with SCPTsetpoint[0,1] and
SCPTgain.
SCPTgain nviYSVal
{SNVT_muldiv
(mulplier,divisor)}
{0...32000,10000}
{10000,10000}
nviYSVal span (gain) adjustment.
Gain = Multiplier / 10000 (Divisor is fixed at 10000.)
Applied to SCPTsetpoint[0,1].

R7L-YS2
EM-7804-E Rev.6 P. 9 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbCV[0,1]
fbCV [0,1] (Object ID : 27, 28)
nvoCVOut
SNVT_lev_percent
SNVT_temp
SNVT_temp_p
SNVT_count_32
nviCVIn
SNVT_lev_percent
SNVT_temp
SNVT_temp_p
SNVT_count_32
Set the value source
Network variable type
0% and 100% setpoints
Network variable type
0% and 100% setpoints
nviCVIn :
SCPTnumDigits
SCPTnvType
SCPTsetpoint [ ]
nvoCVOut :
SCPTnvType
SCPTsetpoint [ ]
Network Variables
Configuration Properties
nv 62,
nv 63
nv 64,
nv 65
• Network Variables
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviCVIn
{SNVT_lev_percent}
{-163.840...163.835}
{0.0}
{SNVT_temp}
{-274.0...6279.5}
{0.0}
{SNVT_temp_p}
{-273.17...327.66}
{0.0}
{SNVT_count_32}
{0...999 999 999}
{0}
Inputs the value to be scaled.
nvoCVOut
{SNVT_lev_percent}
{-163.840...163.835}
{0.0}
{SNVT_temp}
{-274.0...6279.5}
{0.0}
{SNVT_temp_p}
{-273.17...327.66}
{0.0}
{SNVT_count_32}
{0...999 999 999}
{0}
Outputs the scaled value.

R7L-YS2
EM-7804-E Rev.6 P. 10 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTnumDigits nviCVIn
{SNVT_count}
{0}
{0}
Source of the input to nviCVIn
0 : LonMaker bound output network variable
SCPTnvType nviCVIn
{SNVT_nv_type}
{}
{SNVT_temp}
Indicates nviCVIn type.
For use with LonMaker and other tools.
SCPTnvType nvoCVOut
{SNVT_nv_type}
{}
{SNVT_temp}
Indicates nvoCVOut type.
For use with LonMaker and other tools.
SCPTsetpoint[0] nviCVIn Same as nviCVIn Scaling setting
Output SCPTsetpoint[0] (nvoCVOut) is provided with the
input SCPTsetpoint[0] (nviCVIn).
Output SCPTsetpoint[1] (nvoCVOut) is provided with the
input SCPTsetpoint[1] (nviCVIn).
Output is proportionally provided to the input between
these setpoints.
SCPTsetpoint[0] < SCPTsetpoint[1]
SCPTsetpoint[1] nviCVIn Same as nviCVIn
SCPTsetpoint[0] nvoCVOut Same as nvoCVOut
SCPTsetpoint[1] nvoCVOut Same as nvoCVOut
■FUNCTIONAL BLOCK: fbLED
fbLED (Object ID : 29)
nv 66
nviLEDState
SNVT_state
nv 67
nviLEDIn01
SNVT_switch
nv 68
nviLEDIn02
SNVT_switch
nv 69
nviLEDIn03
SNVT_switch
nv 82
nviLEDIn16
SNVT_switch
Network Variables
Configuration Properties
• Network Variables
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviLEDState
{SNVT_state}
{0 or 1}
{0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0}
The front LEDs (0...F) turn on/off according to the input.
Bit 0 through Bit 15 assigned to LED 0 through F respectively.
DO NOT use nviLEDIn01...nviLEDIn16 when nviLEDState is used.
nviLEDIn01...
nviLEDIn16
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
The front LEDs (0...F) turn on/off according to the input.
100.0 1 : LED ON
Other : LED OFF
DO NOT use nviLEDState when nviLEDIn01...nviLEDIn16 is used.

R7L-YS2
EM-7804-E Rev.6 P. 11 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbDOEX[0...7]
This Functional Block is valid only when the output extension module is specified at NodeObject.
fbDOEX[0...7] (Object ID : 1...8)
fbDOEX[ ] :
SCPTdirection
SCPTpwrUpState
Set operating mode
Set the initial value at the startup
Network Variables
Configuration Properties
Extension
discrete output
Y0, Y2, Y4, Y6, Y8, YA, YC, YE
Output nviDOEX1 status
Y1, Y3, Y5, Y7, Y9, YB, YD, YF
Output nviDOEX2 status
nv 4
...nv 11
nviDOEX1
SNVT_switch
nv 12
...nv 19
nviDOEX2
SNVT_switch
• Output Terminal v.s. fbDOEX Network Variables (nviDOEX1, nviDOEX2) Assignments
FUNCTIONAL BLOCK NETWORK VARIABLE OUTPUT TERMINAL
fbDOEX[0] nviDOEX1 Y0
nviDOEX2 Y1
fbDOEX[1] nviDOEX1 Y2
nviDOEX2 Y3
fbDOEX[2] nviDOEX1 Y4
nviDOEX2 Y5
fbDOEX[3] nviDOEX1 Y6
nviDOEX2 Y7
fbDOEX[4] nviDOEX1 Y8
nviDOEX2 Y9
fbDOEX[5] nviDOEX1 YA
nviDOEX2 YB
fbDOEX[6] nviDOEX1 YC
nviDOEX2 YD
fbDOEX[7] nviDOEX1 YE
nviDOEX2 YF

R7L-YS2
EM-7804-E Rev.6 P. 12 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbDOEX[0...7]
• Network Properties
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nviDOEX1
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Turns on or off Y0, Y2, Y4, Y6, Y8, YA, YC, YE of the extension module
depending upon this input.
100.0 1 : ON
Other : OFF
nviDOEX2
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Turns on or off Y1, Y3, Y5, Y7, Y9, YB, YD, YF of the extension module
depending upon this input.
100.0 1 : ON
Other : OFF
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTdirection ----
{SNVT_state}
{0 or 1}
{0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0}
Bit 1: Output held or not at power off
0 : OFF at the power startup
1 : Outputs the held status at the power startup
Bit 0, Bit 2 through 15 : Invalid
SCPTpwrUpState nviDOEX1
{SNVT_switch}
{0.0 0}, {100.0 1},
{Invalid}
{0.0 0}
Set value applied at nviDOEX1 when the power supply is
turned on.
SCPTpwrUpState nviDOEX2
{SNVT_switch}
{0.0 0}, {100.0 1},
{Invalid}
{0.0 0}
Set value applied at nviDOEX2 when the power supply is
turned on.

R7L-YS2
EM-7804-E Rev.6 P. 13 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbDIEX[0...7]
This Functional Block is valid only when the input extension module is specified at NodeObject.
fbDIEX[0...7] (Object ID : 9...16)
nv 20
...nv 27
nvoDIEX1
SNVT_switch
nv 28
...nv 35
nvoDIEX2
SNVT_switch
Network Variables
Configuration Properties
Extension
discrete Input
X0, X2, X4, X6, X8, XA, XC, XE X1, X3, X5, X7, X9, XB, XD, XF
Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2
Combination Mode Refer to the table in the next page.
fbDIEX[ ] :
SCPTdirection
nvoDIEX1 :
SCPTinvrtOut
nvoDIEX2 :
SCPTinvrtOut
Set operating mode
Invert output
Invert output
• Input Terminal v.s. fbDIEX Network Variables (nvoDIEX1, nvoDIEX2) Assignments
FUNCTIONAL BLOCK NETWORK VARIABLE INPUT TERMINAL
fbDIEX[0] nvoDIEX1 X0
nvoDIEX2 X1
fbDIEX[1] nvoDIEX1 X2
nvoDIEX2 X3
fbDIEX[2] nvoDIEX1 X4
nvoDIEX2 X5
fbDIEX[3] nvoDIEX1 X6
nvoDIEX2 X7
fbDIEX[4] nvoDIEX1 X8
nvoDIEX2 X9
fbDIEX[5] nvoDIEX1 XA
nvoDIEX2 XB
fbDIEX[6] nvoDIEX1 XC
nvoDIEX2 XD
fbDIEX[7] nvoDIEX1 XE
nvoDIEX2 XF

R7L-YS2
EM-7804-E Rev.6 P. 14 / 14
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■FUNCTIONAL BLOCK: fbDIEX[0...7]
• Network Variables
Normal Mode
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nvoDIEX1
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Outputs X0, X2, X4, X6, X8, XA, XC, XE status of the extension module
nvoDIEX2
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Outputs X1, X3, X5, X7, X9, XB, XD, XF status of the extension module
Combination Mode
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
nvoDIEX1
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
Contact input, nvoDIEX1 and nvoDIEX2 Reference Table
X0
X2
X4
X6
X8
XA
XC
XE
X1
X3
X5
X7
X9
XB
XD
XF
nvoDIEX1 nvoDIEX2
OFF OFF 0.0 0 (OFF) Invalid
ON OFF 100.0 1 (ON) Invalid
OFF ON 0.0 0 (OFF) 0.0 0 (OFF)
ON ON 100.0 1 (ON) 100.0 1 (ON)
nvoDIEX2
{SNVT_switch}
{0.0 0}, {100.0 1}, {Invalid}
{0.0 0}
• Conguration Properties
CONFIGURATION
PROPERTY
NETWORK
VARIABLE
TYPE
{ Range }
{ Default }
EXPLANATIONS
SCPTdirection ----
{SNVT_state}
{0 or 1}
{0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0}
Bit 0, Bit 1: fbDIEX operating mode
0,0 : Normal mode
0,1 : Combination mode
Bit 2 through 15 : Invalid
SCPTinvrtOut nvoDIEX1
{SNVT_lev_disc}
{ST_OFF, ST_ON}
{ST_OFF}
Contact input logic is inverted at nvoDIEX1.
ST_OFF : OFF at open contact, ON at closed contact
ST_ON : ON at open contact, OFF at closed contact
SCPTinvrtOut nvoDIEX2
{SNVT_lev_disc}
{ST_OFF, ST_ON}
{ST_OFF}
Contact input logic is inverted at nvoDIEX2.
ST_OFF : OFF at open contact, ON at closed contact
ST_ON : ON at open contact, OFF at closed contact
Table of contents
Other MG Control Unit manuals
Popular Control Unit manuals by other brands

Fastwel
Fastwel CPB904 user manual

DynaQuip
DynaQuip WaterCop LEAK STOP+ Owner's manual and installation guide

Schmidt
Schmidt PressControl 3000 Operator's manual

Grundfos
Grundfos CIM 3 Series Installation and operating instructions

Kohler
Kohler Mira Select B14C Installation and user guide

Pickering
Pickering 40-527A user manual