manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. Control Unit
  8. •
  9. MG R3-CT4B User manual

MG R3-CT4B User manual

Other MG Control Unit manuals

MG M8YCH User manual

MG

MG M8YCH User manual

MG R5-SS1A User manual

MG

MG R5-SS1A User manual

MG R6S-SS2 User manual

MG

MG R6S-SS2 User manual

MG R3-DC64C User manual

MG

MG R3-DC64C User manual

MG R3-CT4B User manual

MG

MG R3-CT4B User manual

MG JFK User manual

MG

MG JFK User manual

MG R7ML-EA8 User manual

MG

MG R7ML-EA8 User manual

MG 10BW User manual

MG

MG 10BW User manual

MG R6S-TS2A User manual

MG

MG R6S-TS2A User manual

MG R80YVT4N User manual

MG

MG R80YVT4N User manual

MG R7L-EA16 User manual

MG

MG R7L-EA16 User manual

MG R80DAT16A2 User manual

MG

MG R80DAT16A2 User manual

MG R30US4 User manual

MG

MG R30US4 User manual

MG R7LWTU User manual

MG

MG R7LWTU User manual

MG 18KYC User manual

MG

MG 18KYC User manual

MG R3-DC32C User manual

MG

MG R3-DC32C User manual

MG R5-RS1A User manual

MG

MG R5-RS1A User manual

MG R6D-SS2 User manual

MG

MG R6D-SS2 User manual

MG R7F4HC-DAC32C-K User manual

MG

MG R7F4HC-DAC32C-K User manual

MG R3-NCIE1 User manual

MG

MG R3-NCIE1 User manual

MG R7E-EC16A User manual

MG

MG R7E-EC16A User manual

MG R8-SST8 User manual

MG

MG R8-SST8 User manual

MG R5-TS1A User manual

MG

MG R5-TS1A User manual

MG R3Y-YS4 User manual

MG

MG R3Y-YS4 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EM-8445 Rev.4 P. 1 / 3
INSTRUCTION MANUAL
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
AC CURRENT INPUT MODULE
(4 points, isolated, clamp-on current sensor type CLSB use) MODEL R3-CT4B
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
AC current input module....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-CT4B
EM-8445 Rev.4 P. 2 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■ FRONT VIEW ■ SIDE VIEW
ERR LED
RUN LED
Conv.
Rate
Input 2 (SW1)
or
Input 4 (SW2)
Range
Input 1 (SW1)
or
Input 3 (SW2)
Functions
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input abnormality;
Green in normal operating conditions.
■SIDE DIP SW
(*) Factory setting
• Input Range: SW1, SW2
INPUT 1 (SW1) INPUT 2 (SW1)
RANGEINPUT 3 (SW2) INPUT 4 (SW2)
12345678
OFF OFF OFF OFF OFF OFF OFF OFF CLSB-60 (*)
ON OFF OFF OFF ON OFF OFF OFF CLSB-40
OFF ON OFF OFF OFF ON OFF OFF CLSB-20
ON ON OFF OFF ON ON OFF OFF CLSB-10
OFF OFF ON OFF OFF OFF ON OFF CLSB-05
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
80 ms (*)40 ms 20 ms 10 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
Note: Be sure to set unused SW3-3 and 3-4 to OFF.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Zero Base Depends on sensor type 0.00
Full Base Depends on sensor type 0.00
Unused 0: Enable
1: Disable
0: Enable
R3-CT4B
EM-8445 Rev.4 P. 3 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
BUS CONNECTOR
INTERNAL
POWER
INTERNAL
BUS A
INTERNAL
BUS B*
*For dual redundant communication.
INPUT 1
1
2
INPUT 2
3
4
LOAD
SOURCE
k
l
LOAD
SOURCE
k
l
INPUT 3
6
7
INPUT 4
8
9
LOAD
SOURCE
k
LOAD
SOURCE
l
CLAMP-ON SENSOR
CLAMP-ON SENSOR
CLAMP-ON SENSOR
CLAMP-ON SENSOR
k
l
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.75 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)