EM-7781-AC Rev.4 P. 1 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
DC CURRENT INPUT MODULE, 2 points
(Euro terminal) MODEL R6D-SS2
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
DC current input module....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The unit is programmable using the PC Configurator Soft-
ware. For detailed information on the PC configuration, re-
fer to the R6CON users manual. The R6CON PC Configu-
rator Software is downloadable at our web site.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• Insert a noise filter for the input and communication line
connected to the unit. NEC TOKIN Model ESD-SR-250
or equivalent is recommended.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■HOT INSERTION/REMOVAL OF MODULES
• Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■GENERAL PRECAUTIONS
• Do NOT set the switches while the power is supplied.
The switches are used only for maintenance without the
power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■UNUSED INPUT CHANNELS
• Set the unused channels to -40 – +40 mA range. Unused
channels left open with other settings may be equal to the
input lower than -15%, which sets a data abnormality at
the PLC or the host device.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
Body
Front Cover
Mounting Adaptor
INSTALLATION
Mount the unit on the base (model: R6D-BS).
R6D-SS2
EM-7781-AC Rev.4 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
EXTERNAL VIEWS
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
• Front View (cover opened) • Side View
5678
1234
1
SW3
SW2
SW1
2345678
OFF
ON
0
16
SW3
SW2
SW1
Module Address
Setting
Operating Mode
Setting
Status LED
Power LED
■INDICATOR LED
ID COLOR FUNCTION
Power OFF Power supply is off
Green ON Power supply is on.
Status OFF Standing by (at the startup)
or communication error
Green ON Normal communication
Green blink Configuration mode
Red ON DIP switch error
Red blink
2 sec. interval
Parameter error
Red blink
0.5 sec. interval
Analog input overrange
(≤ -15% or ≥ 115%)
■MODULE ADDRESS
Module address is selectable between 0 and 31. Choose 0 or
16 with SW1 for offsetting the address selected with SW2 (0
to F, hexadecimal).
The module’s slot position on the base and the module ad-
dress are not necessarily correlated.
ADDRESS SW1 SW2 ADDRESS SW1 SW2
0 0 0 16 16 0
1 0 1 17 16 1
2 0 2 18 16 2
3 0 3 19 16 3
4 0 4 20 16 4
5 0 5 21 16 5
6 0 6 22 16 6
7 0 7 23 16 7
8 0 8 24 16 8
9 0 9 25 16 9
10 0 A 26 16 A
11 0 B 27 16 B
12 0 C 28 16 C
13 0 D 29 16 D
14 0 E 30 16 E
15 0 F 31 16 F
■OPERATING MODE
(*) Factory setting
• Conguration Mode
CONFIGURATION MODE SW3-8
DIP SW (*)
PC ■
■= ON, Blank = OFF
• Input Range
RANGE
INPUT 1 INPUT 2
SW3 SW3
123456
-40 – +40 mA DC
-20 – +20 mA DC ■ ■
-1 – +1 mA DC ■ ■
0 – 40 mA DC ■ ■ ■ ■
0 – 20 mA DC ■ ■
4 – 20 mA DC (*) ■ ■ ■ ■
0 – 1 mA DC ■ ■ ■ ■
■= ON, Blank = OFF
Note: Be sure to set unused SW3-7 to OFF.
R6D-SS2
EM-7781-AC Rev.4 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
94 (3.70)
5.9 (.23)
102 (4.02)
5678
1234
8–M3
EURO TERMINAL
WIRE INSERTION ANGLE: approx. 7°
■CONNECTION DIAGRAM
BUS CONNECTOR
INPUT 1
3
1
+
–
2
NARROW SPAN
WIDE SPAN
+
INPUT 2
7
5
+
–
6
NARROW SPAN
WIDE SPAN
+
INTERNAL
POWER
INTERNAL
BUS
• Wide span: -40 – +40 mA DC, -20 – +20 mA DC,
0 – 40 mA DC, 0 – 20 mA DC, 4 – 20 mA DC
• Narrow span: -1 – +1 mA DC, 0 – 1 mA DC
■WIRING INSTRUCTIONS
• Applicable wire size
Solid: 0.2 to 2.5 mm2(0.55 to 1.75 dia.)
Stranded: 0.2 to 2.5 mm2(Tinning wire ends may cause
contact failure and therefore is not recom-
mended.)
Ferruled: 0.2 to 1.5 mm2(0.55 to 1.35 dia.)
• Expose wire conductors by 8 mm (0.31”).
8 mm 8 mm
3.7 mm dia.
max.
3.7 mm dia.
max.
Wire exposure Recommended
ferruled wire
R6D-SS2
EM-7781-AC Rev.4 P. 4 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
• How to Connect Wires
Screwdriver
Wire
Insert a wire. Confirm that the wire tip hits the bottom and
tighten the screw with a screwdriver.
Confirm that the wire’s insulation tube is not caught in the
terminal. (Torque: 0.3 N.m)
Screwdriver
Wire
8 mm
6 mm
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R6CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Input range -40 to +40 mA DC,
-1 to +1 mA DC
-40 to +40 mA DC
Lower range value -40.00 to +40.00 (mA)
-1.00 to +1.00 (mA)
4.00 (mA)
Upper range value -40.00 to +40.00 (mA)
-1.00 to +1.00 (mA)
20.00 (mA)
Fine zero adjustment -320.00 to +320.00 (%) 0.00 (%)
Fine gain adjustment -3.2000 to +3.2000 1.0000
Scaled range Zero -32000 to +32000 0
Scaled range Span -32000 to +32000 10000
■CHANNEL BATCH SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Loss of internal bus commu-
nication detection time
0.0 to 99.9 (sec.) 1.0 (sec.)
Conversion rate 10, 20, 40, 80 (msec.) 80 (msec.)

Other MG Control Unit manuals

MG R3-DC32C User manual

MG

MG R3-DC32C User manual

MG R3-NCIE1 User manual

MG

MG R3-NCIE1 User manual

MG M8YCH User manual

MG

MG M8YCH User manual

MG R6S-SS2 User manual

MG

MG R6S-SS2 User manual

MG R5-SS1A User manual

MG

MG R5-SS1A User manual

MG R6-NE2 User manual

MG

MG R6-NE2 User manual

MG 18KYC User manual

MG

MG 18KYC User manual

MG R3-DC64C User manual

MG

MG R3-DC64C User manual

MG R7E-EA16 User manual

MG

MG R7E-EA16 User manual

MG R3-YS4 User manual

MG

MG R3-YS4 User manual

MG R80YVT4N User manual

MG

MG R80YVT4N User manual

MG R7F4HC-DAC32C-K User manual

MG

MG R7F4HC-DAC32C-K User manual

MG 10BW User manual

MG

MG 10BW User manual

MG R3-CT4B User manual

MG

MG R3-CT4B User manual

MG R30US4 User manual

MG

MG R30US4 User manual

MG R3Y-YS4 User manual

MG

MG R3Y-YS4 User manual

MG R5-RS1A User manual

MG

MG R5-RS1A User manual

MG R80DAT16A2 User manual

MG

MG R80DAT16A2 User manual

MG Devicenet R7F4DD-DA16A-H User manual

MG

MG Devicenet R7F4DD-DA16A-H User manual

MG R3-AS8 User manual

MG

MG R3-AS8 User manual

MG R6S-TS2A User manual

MG

MG R6S-TS2A User manual

MG R7L-EA16 User manual

MG

MG R7L-EA16 User manual

MG R7L-YS2 User manual

MG

MG R7L-YS2 User manual

MG R7L-YV2 User manual

MG

MG R7L-YV2 User manual

Popular Control Unit manuals by other brands

VSI AWWA C504 Installation, operation and maintenance manual

VSI

VSI AWWA C504 Installation, operation and maintenance manual

Omega DMD1080 user guide

Omega

Omega DMD1080 user guide

JVC RM-P200 Service manual

JVC

JVC RM-P200 Service manual

BFT ELMEC1 instructions

BFT

BFT ELMEC1 instructions

Current Technology ISM Series Installation, operation and maintenance manual

Current Technology

Current Technology ISM Series Installation, operation and maintenance manual

ADDAC System ADDAC900PD Assembly guide

ADDAC System

ADDAC System ADDAC900PD Assembly guide

Daikin BRC230Z4 installation manual

Daikin

Daikin BRC230Z4 installation manual

Roco and Fleischmann Z21 user manual

Roco and Fleischmann

Roco and Fleischmann Z21 user manual

Magnetic MPT-333 manual

Magnetic

Magnetic MPT-333 manual

MSA M1 operating manual

MSA

MSA M1 operating manual

TiSUN MULTIPLEX user guide

TiSUN

TiSUN MULTIPLEX user guide

Industrial Shields PLC 10 manual

Industrial Shields

Industrial Shields PLC 10 manual

Viavi mA-3A01 Operation guide

Viavi

Viavi mA-3A01 Operation guide

Volth ARGO HYTOS PVRM2X3-103 operating instructions

Volth

Volth ARGO HYTOS PVRM2X3-103 operating instructions

Sistemes Electrònics Progrés s.a. AGRONIC 4000 instruction manual

Sistemes Electrònics Progrés s.a.

Sistemes Electrònics Progrés s.a. AGRONIC 4000 instruction manual

check-all Valve EPIC Installation & operation manual

check-all Valve

check-all Valve EPIC Installation & operation manual

Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 manual

Pepperl+Fuchs

Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 manual

Lamtec ETAMATIC quick reference

Lamtec

Lamtec ETAMATIC quick reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.