Microtronics myDatalogNANO User manual

300357 | Rev.02
Cover
Valid from:
lFirmware version: 03v003
lModem Version: 03v002
lServer version: 40.1
lHardware version: 2.0
User manual
myDatalogNANO


Chapter 1 Table of contents
Chapter 1 Table of contents
Cover 1
Chapter 1 Table of contents 3
Chapter 2 Declaration of conformity 9
Chapter 3 Technical data 11
Chapter 4 General specifications 13
4.1 Translation 13
4.2 Copyright 13
4.3 General descriptive names 13
4.4 Safety instructions 13
4.4.1 Use of the hazard warnings 14
4.4.2 General safety instructions 14
4.4.3 Safety and preventative measures for handling GSM/GPRS modems 14
4.4.3.1 Safety and precautionary measures for the installation of the GSM/GPRS modem 15
4.4.3.2 Safety measures for installing the antenna 15
4.5 Overview 16
4.5.1 Block diagram 17
4.6 Intended use 18
4.7 General product information 18
4.8 Device labelling 19
4.9 Installation of spare and wear parts 19
4.10 Storage of the product 20
4.11 Obligation of the operator 20
4.12 Personnel requirements 20
Chapter 5 Functional principle 23
5.1 Internal processing of the measurement values 25
5.1.1 Filter module 26
5.1.2 Overflow module 27
5.1.3 Scale module 28
5.1.4 Decay module 28
5.1.5 Hold module 29
5.1.6 Alarm/trigger module 29
Rev. 02 3

5.1.7 Record module 30
5.1.7.1 Alarm flags 31
5.1.7.2 Trigger flags 31
5.2 ALOHA transmission mode 32
5.3 Automatic selection of the GSM network 33
5.3.1 Ban list 33
Chapter 6 Storage, delivery and transport 35
6.1 Inspection of incoming deliveries 35
6.2 Scope of supply 35
6.3 Storage 35
6.4 Transport 35
6.5 Return 37
Chapter 7 Installation 39
7.1 Dimensions 39
7.2 Installing the myDatalogNANO 39
7.2.1 Wall mounting 40
7.2.2 Top-hat rail assembly 42
7.2.3 Pipe assembly 43
7.3 Safety instructions for the cabling 44
7.3.1 Information on preventing electrostatic discharges (ESD) 44
7.4 Electrical installation 44
7.4.1 Connecting the sensors 44
7.4.1.1 Connection examples 46
7.4.1.2 Use of the clamping tubes 47
7.4.1.3 Using Pressure compensation tube with 1x 0/4-20mA 24VDC " (300255 ) 47
7.4.2 Connecting the GSM antenna 49
7.4.3 Optimum antenna positioning for assembly in a shaft 49
7.4.3.1 Typical influences on the signal quality 49
7.4.3.2 Possibilities for improving the signal quality 50
7.4.3.3 Procedure for determining the optimum position of the antenna 50
7.4.4 Technical details about the universal inputs 51
7.4.4.1 0/4...20mA mode 51
7.4.4.2 Voltage 0...2V 52
4Rev. 02

Chapter 1 Table of contents
7.4.4.3 Digital modes (digital, day counter, pulse counter, frequency, PWM) 52
7.4.4.4 Temperature modes (PT1000, KTY81110, KTY81210, NI1000, TK5000) 53
7.4.5 Technical detailsabout the "switchable sensor supply (Vout)" 54
7.4.6 Technical details about the device operating time 57
Chapter 8 Initial Start-Up 59
8.1 User information 59
8.2 General principles 59
8.3 Commissioning the system 59
8.4 Testing communication with the device 61
Chapter 9 User interfaces 63
9.1 User interface on the myDatalogNANO 63
9.1.1 Operating elements 63
9.1.1.1 Solenoid switch 63
9.1.1.2 Status LED 64
9.2 User interface on the myDatanet server 65
9.2.1 Site configuration 65
9.2.1.1 Site 65
9.2.1.2 Comments 65
9.2.1.3 Measurement channels 65
9.2.1.3.1 Basis 65
9.2.1.3.2 Config 69
9.2.1.3.3 Alarms 79
9.2.1.3.4 Trigger 80
9.2.1.4 Calculated channels 80
9.2.1.4.1 Basis 81
9.2.1.4.2 Calculation 82
9.2.1.4.3 Alarms 83
9.2.1.5 Output channels 84
9.2.1.5.1 Basis 84
9.2.1.6 Internal channels 84
9.2.1.6.1 Basis 84
9.2.1.6.2 Alarms 84
9.2.1.6.3 Trigger 85
Rev. 02 5

9.2.1.7 Alarm settings 86
9.2.1.8 Basic setting 87
9.2.1.9 FTP export settings 89
9.2.2 Device configuration 89
9.2.2.1 Comments 89
9.2.2.2 Measurement instrument 89
9.2.2.3 Device-specific settings 91
9.2.2.4 GPRS 91
Chapter 10 myDatanet server 93
10.1 Overview 93
10.1.1 Explanation of the symbols 93
10.2 "Customer" area 94
10.3 "Site" area at customer level 96
10.3.1 Reports 97
10.3.2 Groups 97
10.3.3 Map view 97
10.4 Recommended procedure 97
10.4.1 Creating the site 97
10.4.2 Assigning a device to the customer 99
Chapter 11 API 101
11.1 General 101
11.2 rapidM2M Playground 101
11.2.1 Overview 102
Chapter 12 Maintenance 103
12.1 General maintenance 103
12.2 Replacing the battery pack 104
Chapter 13 Removal/disposal 107
Chapter 14 Troubleshooting and repair 109
14.1 General problems 109
14.2 Log entries and error codes 110
14.2.1 Modem error 114
14.3 Evaluating the device log 117
14.3.1 Evaluating the device log on the myDatanet server 117
6Rev. 02

Chapter 1 Table of contents
14.3.2 Evaluating the device log using DeviceConfig 117
Chapter 15 Spare parts and accessories 119
15.1 Assembly sets 119
15.2 Antennas 119
15.3 Battery packs 119
15.4 Cable 119
15.5 Other accessories 119
Chapter 16 Application example 121
16.1 Measuring the heat quantity (in heating systems) 121
16.1.1 Requirements 121
16.1.2 Required configuration 122
16.2 Flow ratemeasurement (in lines) 122
16.2.1 Requirements 122
16.2.2 Required configuration 123
16.3 Temperature measurement (freezing, food trade) 124
16.3.1 Requirements 124
16.3.2 Required configuration 124
Chapter 17 Document history 127
Chapter 18 Glossary 129
Chapter 19 Contact information 131
Rev. 02 7


Chapter 2 Declaration of conformity
Chapter 2 Declaration of conformity
Rev. 02 9


Chapter 3 Technical data
Chapter 3 Technical data
Voltage supply BP713RLC Battery : 2 x Li-SOCl2 cells fully fabricated with 13Ah
Housing Material: UL94HB/UL94V0 (housing/lid)
Weight: 510g (incl. battery)
Degree of protection: IP68
Dimensions (WHD): 86 x 152 x 64mm (without connection cable)
Operating
temperature
Standard: -10...+50°C, 15...90%rH non-condensing
Extended: -20...+60°C (functional parameters may be impaired)
Storage
temperature
-30...+85°C
Display LED for indicating the operating state and error codes
Operation Solenoid switch for initiating ALOHA transmission mode
Antenna
connector
TNC-F
Universal inputs 5 x analogue or digital
Modes:
lVoltage 0...2V: Resolution 610µV, max. 2,5V, load 680k2
lPWM: 1...99% , max. 25Hz , min. pulse length 20ms
lFrequency: 1...25Hz
lDigital: low <2,3V, high >2,4V
lDay counter: Minimum pulse length 20ms
lInterval counter: Minimum pulse length 20ms
lTemperature: Typ. resolution. 0,5°C , load 2k2,
Measurement range -20...+80°C (-40...+150°C at reduced accuracy),
supported sensors: PT1000, KTY81-120, KTY81-210, Ni1000, Ni1000/TK5000
Additional information is provided in "Technical details about the universal inputs" on
page 51.
Outputs 1 x switchable sensor supply
lUout: 3 VDC (+/-50mV)
lIout max: 290mA (short-circuit-proof)
Additional information is provided in "Technical detailsabout the "switchable sensor
supply (Vout)"" on page 54.
Data memory Internal flash memory for up to 26.360 measurement cycles
Data type f32(32 Bit floating point)
Data transmission By means of GSM/GPRS quad-band modem to the respective myDatanet server
SIM The myDatalogNANO is equipped with an integrated SIM chip.
Monthly data
volume
t.b.d. at two-minute measurement cycle and 120-minute transmission cycle
Rev. 02 11


Chapter 4 General specifications
Chapter 4 General specifications
The information in this manual has been compiled with great care and to the best of our knowledge. The
manufacturer, however, assumes no liability for any incorrect specifications that may be provided in this
manual. The manufacturer is not responsible for direct, indirect, accidental or consequential damages which
arise from errors or omissions in this manual even if advised of the possibility of such damages. In the interest
of continuous product development, the manufacturer reserves the right to make improvements to this
manual and the products described in it at any time and without prior notification or obligation.
Note: The specifications in this manual are valid as of the versions listed on the front page. Revised versions
of this manual, as well as software and driver updates are available in the service area of the myDatanet
server.
4.1 Translation
For deliveries to countries in the European Economic Area, the manual must be translated into the language
of the respective country. If there are any discrepancies in the translated text, the original manual (German)
must be referenced or the manufacturer contacted for clarification.
4.2 Copyright
The copying and distribution of this document as well as the utilisation and communication of its contents to
others without express authorisation is prohibited. Contraventions are liable to compensation. All rights
reserved.
4.3 General descriptive names
The use of general descriptive names, trade names, trademarks and the like in this manual does not entitle
the reader to assume they may be used freely by everyone. They are often protected registered trademarks
even if not marked as such.
4.4 Safety instructions
For the connection, commissioning and operation of the myDatalogNANO , the following information and
higher legal regulations of the country (e.g. ÖVE), such as valid EX regulations as well as the applicable
safety and accident prevention regulations for the respective application case must be observed.
Read this manual completely before unpacking, setting up or operating this device. Observe all hazard,
danger and warning information. Non-observance can lead to serious injuries to the operator and/or damage
to the device.
Ensure that the safety equipment of this measurement instrument is not impaired. Install and use the
measurement system only in the manner and method described in this manual.
Important note: The manufacturer's products that are designed for use outdoors include extensive
protection against penetrating moisture and dust.
Rev. 02 13

4.4.1 Use of the hazard warnings
DANGER:
Indicates a potential or threatening hazardous situation that will result in death or serious
injuries if not avoided.
WARNING:
Indicates a potential or threatening hazardous situation that can result in death or serious
injuries if not avoided.
CAUTION:
Indicates a potential hazardous situation that can result in minor or moderate injuries or
damage to this instrument.
Important note: Indicates a situation that can result in damages to this instrument if it is not avoided.
Information that must be particularly emphasised.
Note: Indicates a situation that does not result in any injury to persons.
Note: Information that supplements the specifications in the main text.
4.4.2 General safety instructions
WARNING:
Ensure that the device is fully deactivated and cannot activate automatically when
sending/returning it as air freight. Information on this is provided in chapter "Storage of
the product" on page 20. If you have any unanswered questions, contact the manufacturer
(see "Contact information" on page 131).
WARNING:
Never use this device in areas where the use of wireless equipment is prohibited. The
device must not be used in hospitals and/or in the vicinity of medical equipment, such as
heart pacemakers or hearing aids, as their functionality could be compromised by the
GSM/GPRS modem contained in the device.
WARNING:
Never use this device in potentially explosive atmospheres and in the vicinity of highly
combustible areas (fuel stations, storage areas for combustible material, chemical plants
and detonation sites) or in the vicinity of flammable gases, vapours or dust.
4.4.3 Safety and preventative measures for handling GSM/GPRS modems
The following safety and preventative measures must be observed during all phases of installation, operation,
maintenance or repair of a GSM/GPRS modem. The manufacturer is not liable if the customer disregards
these preventative measures.
CAUTION:
The GSM/GPRS modem connection must not be used in hazardous environments.
No guarantee of any kind, whether implicit or explicit, is given by the manufacturer and its suppliers for the use
with high risk activities.
14 Rev. 02

Chapter 4 General specifications
In addition to the following safety considerations, all directives of the country in which the device is installed
must be complied with.
Important note: No liability shall be assumed at any time and under no circumstances for
connections via a GSM/GPRS modem for which wireless signals and networks are utilized. The
GSM/GPRS modem must be switched on and operated in an area where sufficient signal strength is
present.
4.4.3.1 Safety and precautionary measures for the installation of the GSM/GPRS modem
lThis device must only be installed by a trained technician who applies the recognised installation
practices for a radio frequency transmitter including the correct grounding of external antennas.
lThe device must not be operated in hospitals and/or in the vicinity of medical equipment such as heart
pacemakers or hearing aids.
lThe device must not be operated in highly flammable areas such as petrol filling stations, fuel storage
sites, chemical factories and explosion sites.
lThe device must not be operated in the vicinity of flammable gases, vapours or dusts.
lThe device must not be subjected to strong vibrations or impacts.
lThe GSM/GPRS modem can cause interferences if it is located in the vicinity of television sets, radios
or computers.
lDo not open the GSM/GPRS modem. Any modification to the equipment is prohibited and will result in
the operating licence being revoked.
lThe use of GSM services (SMS messages/data communication/GPRS, etc.) may incur additional
costs. The user is solely responsible for any resulting damages and costs.
lDo not install the device in any other way to the one described in the operating instructions. Improper
use will invalidate the warranty.
4.4.3.2 Safety measures for installing the antenna
lOnly use antennas that are recommended or supplied by the manufacturer.
lThe antenna must be installed at a distance of at least 20 cm from individuals.
lThe antenna must not be extended outside protected buildings and must be protected against lightning
strikes.
lThe voltage supply must be switched off before replacing the antenna.
Rev. 02 15

4.5 Overview
Overview myDatalogNANO
1Housing cover 3Sensor connector
2Antenna connector
16 Rev. 02

Chapter 4 General specifications
4.5.1 Block diagram
Block diagram of the myDatalogNANO
Rev. 02 17

4.6 Intended use
The portable measurement instrument is used to collect analogue and digital signals. The device can operate
without mains power. The measured and recorded data is stored on a non-volatile memory medium. This
stored data is sent via the mobile network to a central server for further processing. The device is equipped
with an integrated SIM chip for this purpose. The maximum permissible limit values specified in chapter
"Technical data" on page 11 must be observed. The manufacturer shall not be liable for any operational cases
that deviate from these limit values and have not been approved by the manufacturer in writing.
Note: This device is exclusively intended to be used for the purposes as described before. Any other
use or use beyond what is specified or a modification of the device shall be deemed to be not for the
intended purpose and is not permitted without the express written consent of the manufacturer. The
manufacturer shall not be held liable for any damages that may result from such unauthorised use or
modification. The operator alone bears the associated risk.
Note: The manufacturer is not liable for data loss of any kind.
Note: The integrated SIM chip provides a mobile communications connection to a variety of
international service providers. In order to be able to utilise all functions of the device, you must
ensure that the device is located in the service area of one of these service providers. You can find a
list of all supported countries and associated service providers under
www.microtronics.com/footprint. A Managed Service contract with Microtronics Engineering GmbH
is required for use of the mobile data transmission (see www.microtronics.com/managedservice).
This includes the provisioning of the mobile communications connection via the network of the service
provider included in the above-mentioned list.
4.7 General product information
The device is a compact, portable instrument for recording and transferring analogue and digital signals. The
energy is supplied by an integrated, replaceable battery pack. There are 5 universal inputs available, which
can be operated in various analogue and digital modes. A 1 voltage output is also available that can be
configured in such a way that it is connected by the device itself before a measurement (to supply a sensor).
All of the input measurement data is temporarily saved to an internal data memory along with the state of the
output and the internal "Battery" and "GSM level" measurement values and are then wirelessly transferred to
a central location at afreely selected interval. The device is also configured via this connection. The device is
equipped with an integrated SIM chip.
18 Rev. 02

Chapter 4 General specifications
4.8 Device labelling
The specifications in this user manual apply exclusively to the myDatalogNANO device type. The type plates
are located on the right side of the device and contain the following specifications:
lType designation
lItem number
lManufacturer's address
lSpecification of the device range
lSerial number
lEnvironmental conditions during operation
lProtection class
lCountry list profile of the SIM chip
lHardware revision
lCE marking
The correct specification of the type designation and serial number is important for all queries and spare part
orders. Only then can we process requests promptly and properly.
Type plates myDatalogNANO
Note: This symbol indicates the country list profile (see www.microtronics.com/footprint) of the SIM chip
installed in the device.
Note: These operating instructions are part of the device and must be available to the user at all
times. The safety instructions contained therein must be observed.
DANGER:
It is strictly prohibited to disable the safety equipment or modify its mode of operation.
4.9 Installation of spare and wear parts
Be advised that spare and accessory parts that have not been supplied by the manufacturer have also not
been inspected or approved by the manufacturer. The installation and/or use of such products can possibly
have a negative impact on the specified constructional properties of the device. The manufacturer shall not be
liable for any damages that arise from the use of non-original parts and non-original accessory parts.
Rev. 02 19

4.10 Storage of the product
To store the myDatalogNANO , activate the transport lock, by setting the "Operation mode" in the input
screen of the myDatanet server for configuring the device (see "Device-specific settings" on page 91) to
"OFF". Then activate ALOHA transmission mode (see "ALOHA transmission mode" on page 32) via the
solenoid switch so that the amended configuration is transferred to the myDatalogNANO . During this
process, all of the data that has not yet been transferred to the myDatanet server is transferred. The cables
can be removed as soon as the GPRS connection has been deactivated - indicated by the status LED going
out (see "Status LED" on page 64). Store the myDatalogNANO in its original packaging. The battery pack
remains in the device.
The myDatalogNANO is placed in energy-saving mode by activating the transport lock. However, it may still
occur that the battery pack is fully discharged if the device is stored for very long periods. Although the
configuration and the most recently determined data are always retained. The transport lock is deactivated
again by re-initiating ALOHA transmission mode (see "ALOHA transmission mode" on page 32) and the
myDatalogNANO resumes operation according to the configuration.
4.11 Obligation of the operator
WARNING:
In the EEA (European Economic Area), the national implementation of the framework
directive (89/391/EEC) as well as the associated specific directives and from these in
particular, the directive (2009/104/EC) about the minimum safety and health requirements
for use of work equipment by workers at work, each in their respective version are to be
complied with.
The operator must obtain the local operating licence and the associated documents.
In addition, the operator must comply with the local legal requirements for
lthe safety of the personnel (accident prevention measures)
lthe safety of the equipment (protective equipment and maintenance)
lthe product disposal (waste disposal law)
lthe material disposal (waste disposal law)
lthe cleaning (cleaning agents and disposal)
land the environmental protection amendments.
Before commissioning, the operator must ensure that the installation and commissioning – provided these
were performed by the operator himself – are in compliance with the local regulations.
4.12 Personnel requirements
Installation, commissioning and maintenance may only be completed by personnel who meet the following
conditions:
lQualified specialist personnel with the relevant training
lAuthorised by the facility operator
20 Rev. 02
Table of contents
Other Microtronics Data Logger manuals

Microtronics
Microtronics myDatasensMINI H2S 1000 User manual

Microtronics
Microtronics myDatalogEx User manual

Microtronics
Microtronics myDatalogMUC xG/4G User manual

Microtronics
Microtronics myDatalogNANOamr User manual

Microtronics
Microtronics myDatalog2Ex User manual

Microtronics
Microtronics myDatalogGauge 3G User manual

Microtronics
Microtronics myDatalogEASY V3 User manual

Microtronics
Microtronics myDatalogMUC User manual

Microtronics
Microtronics myDatalog4 User manual

Microtronics
Microtronics myDatalogNANO Ex User manual