Chapter 1 Table of contents
Chapter 1 Table of contents
Cover 1
Chapter 1 Table of contents 3
Chapter 2 Declaration of conformity 7
Chapter 3 Ex certification 9
Chapter 4 Specifications 13
Chapter 5 General specifications 15
5.1 Translation 15
5.2 Copyright 15
5.3 General descriptive names 15
5.4 Ex protection 16
5.5 Safety instructions 16
5.5.1 Use of the hazard warnings 17
5.5.2 General safety instructions 17
5.5.3 Safety and preventative measures for handling GSM/GPRS modems 17
5.5.3.1 Safety and precautionary measures for the GSM/GPRS modem installation 18
5.5.3.2 Safety measures for installing the antenna 18
5.6 Overview 19
5.6.1 Block diagram 20
5.7 Intended use 20
5.8 General product information 21
5.9 Device labelling 21
5.10 Installation of spare and wear parts 22
5.11 Storage of the product 22
5.12 Warranty 22
5.13 Disclaimer 23
5.14 Obligation of the operator 23
5.15 Personnel requirements 24
Chapter 6 Functional principle 25
6.1 Functionality of the internal data memory 26
6.2 Procedure in case of connection aborts 27
6.3 Setup mode 27
Rev. 05 3

6.4 Automatic selection of the GSM network 31
Chapter 7 Storage, delivery and transport 33
7.1 Inspection of incoming deliveries 33
7.2 Scope of supply 33
7.3 Storage 33
7.4 Transport 33
7.5 Return 34
Chapter 8 Installation 35
8.1 Dimensions 35
8.2 Installing the myDatalogEx 36
8.2.1 Suspended installation 37
8.3 Electrical installation 38
8.3.1 Connecting the sensor 38
8.3.1.1 Connection examples 40
8.3.1.2 Use of the clamping tubes 41
8.3.2 Connecting the GSM antenna 41
8.3.2.1 Optimum antenna positioning for assembly in a shaft 42
8.3.2.1.1 Typical influences on the signal quality 42
8.3.2.1.2 Possibilities for improving the signal quality 42
8.3.2.1.3 Procedure for determining the optimum position of the antenna 42
8.3.3 Technical details about universal input 43
8.3.3.1 0/4...20mA mode 44
8.3.4 Technical details regarding the sensor supply 44
Chapter 9 Initial Start-Up 47
9.1 User information 47
9.2 Applicable documents 47
9.3 General principles 47
9.4 Placing the system into operation 47
9.4.1 Using the mobile connection (2G/3G) and the myDatanet server 47
9.5 Testing communication with the device 49
9.5.1 Testing communication between the myDatalogEx and the myDatanet server (mobile
connection) 49
Chapter 10 User interfaces 51
4Rev. 05

Chapter 1 Table of contents
10.1 User interface on the myDatalogEx 51
10.1.1 Operating elements 51
10.1.1.1 Reed switch 51
10.1.1.2 Display 52
10.2 User interface on the myDatanet server 54
10.2.1 Site configuration 54
10.2.1.1 Setup data 54
10.2.2 Device configuration 54
10.2.2.1 Comments 54
10.2.2.2 Measurement instrument 55
10.2.2.3 GPRS 56
Chapter 11 myDatanet server 57
11.1 Overview 57
11.1.1 Explanation of the symbols 57
11.2 "Customer" area 58
11.3 "Site" area at customer level 60
11.3.1 Reports 61
11.3.2 Map view 61
11.4 Recommended procedure 61
11.4.1 Creating the site 61
Chapter 12 API 65
12.1 Frontend API 65
12.2 rapidM2M PlaygroundrapidM2M Playground 65
12.2.1 Overview 66
Chapter 13 Maintenance 67
13.1 General maintenance 67
Chapter 14 Removal/disposal 69
Chapter 15 Troubleshooting and repair 71
15.1 General problems 71
15.2 Log entries and error codes 72
15.2.1 Modem error 74
15.3 Evaluating the device log 75
15.3.1 Evaluating the device log on the myDatanet server 75
Rev. 05 5

Chapter 2 Declaration of conformity
Chapter 2 Declaration of conformity
Rev. 05 7


Chapter 3 Ex certification
Chapter 3 Ex certification
Rev. 05 9

10 Rev. 05

Chapter 3 Ex certification
Rev. 05 11

12 Rev. 05

Chapter 4 Specifications
Chapter 4 Specifications
Voltage supply Battery: 2 x Li-SOCl2 cells with a total of 25,74Ah
Enclosure Material: Noryl GTX 973 / PC (enclosure/cover)
Weight: 730g
Protection class: IP67
Dimensions (WHD): 106 x 169 x 61mm (with protective armour)
Ex certification
II 2G Ex ib IIB T3 Gb
Operating temperature -20...+50°C
Air humidity 15...90%rH non-condensing
Storage and transport
temperature
-20...+70°C
Display 1,5" OLED display with a resolution of 128 x 128 pixels and the ability to display
262.144 different colours
Operation Reed switch for activating the display and triggering setup mode
Antenna connector FME-M
Universal inputs 1 x analogue
Modes:
l0...20mA: Resolution 1µA , max. 25,6mA , load 4Ω
l4...20mA: Resolution 1µA , max. 25,6mA , load 4Ω
Additional information is provided in "Technical details about universal input" on
page 43.
Sensor supply 1 x switchable and adjustable sensor supply (0...22V )
lUo: 25,6V
lIo: 82mA
lPo: 0,523W
lCo: 0,31µF
lLo: 1000µH
Additional information is provided in "Technical details regarding the sensor
supply" on page 44.
Data memory Internal flash memory for up to 66.856 measurement cycles
Data type f32 (32Bit floating point)
Data transmission Bluetooth Low Energy:
Range: 20m (depending on the environmental conditions)
Transmission rate: 120 data records/sec.
2G/3G modem (Europe):
2G GPRS 900MHz / 1800MHz
UMTS B1, B8
Rev. 05 13

SIM Integrated SIM chip
Monthly data volume Approx. tbd at 5min. measurement interval and 12h transmission interval
Device operating time Up to 24 months battery life at 5min. measurement interval, 1sec. heat up and
12h transmission interval
14 Rev. 05

Chapter 5 General specifications
Chapter 5 General specifications
The information in this manual has been compiled with great care and to the best of our knowledge. The
manufacturer, however, assumes no liability for any incorrect specifications that may be provided in this
manual. The manufacturer is not responsible for direct, indirect, accidental or consequential damages which
arise from errors or omissions in this manual even if advised of the possibility of such damages. In the interest
of continuous product development, the manufacturer reserves the right to make improvements to this
manual and the products described in it at any time and without prior notification or obligation.
Note: The specifications in this manual are valid as of the versions listed on the front page. Revised versions
of this manual, as well as software and driver updates are available in the service area of the myDatanet
server.
5.1 Translation
For deliveries to countries in the European Economic Area, the manual must be translated into the language
of the respective country. If there are any discrepancies in the translated text, the original manual (German)
must be referenced or the manufacturer contacted for clarification.
5.2 Copyright
The copying and distribution of this document as well as the utilisation and communication of its contents to
others without express authorisation is prohibited. Contraventions are liable to compensation. All rights
reserved.
5.3 General descriptive names
The use of general descriptive names, trade names, trademarks and the like in this manual does not entitle
the reader to assume they may be used freely by everyone. They are often protected registered trademarks
even if not marked as such.
Rev. 05 15

5.4 Ex protection
The battery-powered, stationary myDatalogEx is designed for use in areas with a zone1 explosive
atmosphere.
The following conditions must be observed:
lOnly the manufacturer is permitted to open the enclosure to carry out maintenance work, which must
also be completed strictly outside the Ex area.
lThe manufacturer's original spare parts must be used without exception.
lThe batteries may only be replaced with certified products of identical design.
lPossible danger of electrostatic discharge build-up - clean the device with a moist or electrostatically
dissipative cloth.
lA mounting distance of min. 50mm must be maintained on all sides to prevent any soiling.
lThe device must be protected from UV radiation.
II 2G Ex ib IIB T3 Gb
Important note: The Ex approval is only valid if the corresponding marking is provided on the type
plate of the measurement instruments .
Important note: The certificates of conformity and any relevant test certificates from the respective
authorities must be carefully observed during installation and commissioning.
1myDatalogEx 2Sensor approved for the Ex zone
5.5 Safety instructions
For the connection, commissioning and operation of the myDatalogEx , the following information and higher
legal regulations of the country (e.g. ÖVE), such as valid EX regulations as well as the applicable safety and
accident prevention regulations for the respective application case must be observed.
Read this manual completely before unpacking, setting up or operating this device. Observe all hazard,
danger and warning information. Non-observance can lead to serious injuries to the operator and/or damage
to the device.
Ensure that the safety equipment of this measurement instrument is not impaired. Install and use the
measurement system only in the manner and method described in this manual.
16 Rev. 05

Chapter 5 General specifications
Important note: The manufacturer's products that are designed for outdoor use include extensive
protection against moisture and dust penetration.
5.5.1 Use of the hazard warnings
DANGER:
Indicates a potential or threatening hazardous situation that will result in death or serious
injuries if not avoided.
WARNING:
Indicates a potential or threatening hazardous situation that can result in death or serious
injuries if not avoided.
CAUTION:
Indicates a potential hazardous situation that can result in minor or moderate injuries or
damage to this instrument.
Important note: Indicates a situation that can result in damages to this instrument if it is not avoided.
Information that must be particularly emphasised.
Note: Indicates a situation that does not result in any injury to persons.
Note: Information that supplements the specifications in the main text.
5.5.2 General safety instructions
WARNING:
Never use this device in areas where the use of wireless equipment is prohibited. The
device must not be used in hospitals and/or in the vicinity of medical equipment, such as
heart pacemakers or hearing aids, as their functionality could be compromised by the
GSM/GPRS modem contained in the device.
5.5.3 Safety and preventative measures for handling GSM/GPRS modems
The following safety and preventative measures must be observed during all phases of installation, operation,
maintenance or repair of a GSM/GPRS modem. The manufacturer is not liable if the customer disregards
these preventative measures.
CAUTION:
The GSM/GPRS modem connection must not be used in hazardous environments.
No guarantee of any kind, whether implicit or explicit, is given by the manufacturer and its suppliers for the use
with high risk activities.
In addition to the following safety considerations, all directives of the country in which the device is installed
must be complied with.
Important note: No liability shall be assumed at any time and under no circumstances for
connections via a GSM/GPRS modem for which wireless signals and networks are utilized. The
GSM/GPRS modem must be switched on and operated in an area where sufficient signal strength is
present.
Rev. 05 17

5.5.3.1 Safety and precautionary measures for the GSM/GPRS modem installation
lThis device must only be installed by a trained technician who applies the recognised installation
practices for a wireless frequency transmitter including the correct grounding of external antennas.
lThe device must not be operated in hospitals and/or in the vicinity of medical equipment such as heart
pacemakers or hearing aids.
lThe device must not be subjected to strong vibrations or impacts.
lThe GSM/GPRS modem can cause interferences if it is located in the vicinity of television sets, radios
or computers.
lDo not open the GSM/GPRS modem. Any modification to the device is prohibited and will result in the
operating licence being revoked.
lThe use of GSM services (SMS messages/data communication/GPRS, etc.) may incur additional
costs. The user alone is responsible for any resulting damages and costs.
lDo not install the device in any other way to the one described in the operating instructions. Improper
use will invalidate the warranty.
5.5.3.2 Safety measures for installing the antenna
lOnly use antennas that are recommended or supplied by the manufacturer.
lThe antenna must be installed at a distance of at least 20cm from individuals.
lThe antenna must not protrude beyond the lightning protected area of buildings and must be protected
against lightning strikes!
18 Rev. 05

Chapter 5 General specifications
5.6 Overview
Front of the myDatalogEx
(view without protective armour)
Bottom of the myDatalogEx
(view without protective armour)
1Display 3Antenna connector
2Sensor connector
Rev. 05 19

5.6.1 Block diagram
Block diagram of the myDatalogEx
5.7 Intended use
The measurement instrument is used to capture analogue signals. The device is battery-operated. The
measured and recorded data is stored on a non-volatile memory medium. This stored data is sent via the
mobile network to a central server for further processing. The device is equipped with an integrated SIM chip
for this purpose. The maximum permissible limit values specified in chapter "Specifications" on page 13 must
be observed. The manufacturer shall not be liable for any operational cases that deviate from these limit
values and have not been approved by the manufacturer in writing.
Note: This device is exclusively intended to be used for the purposes as described before. Any other
use or use beyond what is specified or a modification of the device shall be deemed to be not for the
intended purpose and is not permitted without the express written consent of the manufacturer. The
manufacturer shall not be held liable for any damages that may result from such unauthorised use or
modification. The operator alone bears the associated risk.
Note: The manufacturer is not liable for data loss of any kind.
Note: The integrated SIM chip provides a mobile communications connection to a variety of
international service providers. In order to be able to utilise all functions of the device, you must
ensure that the device is located in the service area of one of these service providers. You can find a
list of all supported countries and associated service providers under
www.microtronics.com/footprint. A Managed Service contract with Microtronics Engineering GmbH
is required for use of the mobile data transmission (see www.microtronics.com/managedservice).
This includes the provisioning of the mobile communications connection via the network of the service
provider included in the above-mentioned list.
20 Rev. 05
Table of contents
Other Microtronics Data Logger manuals

Microtronics
Microtronics myDatasensMINI H2S 1000 User manual

Microtronics
Microtronics myDatalogNANOamr User manual

Microtronics
Microtronics myDatalog4 User manual

Microtronics
Microtronics myDatalogEASYplus User manual

Microtronics
Microtronics myDatalogMUC xG/4G User manual

Microtronics
Microtronics myDatalogMUC User manual

Microtronics
Microtronics myDatalog2Ex User manual

Microtronics
Microtronics myDatalogNANO Ex User manual

Microtronics
Microtronics myDatalogGauge 3G User manual

Microtronics
Microtronics myDatalogEASY V3 User manual