MITECH TW102D User manual

GARDEN-TOWER
IR
IR COLUMNS
Available in terminal and bi-directional versions
Installation and user manual
MADE IN ITALY

GARDEN-TOWER IR Installation and user manual Page 2 of 24
Index
Introduction
and warnings
Page 3
Components
Page 4
General
installation instructions
Page 6
Mounting
options
Page 6
Installation
solutions
Page 10
•
Wall mounting (GAR WL bracket) …………………………………………………………………………………………… 6
•
Ground mounting (GAR GR base) ………….….…………………………………………………………………………… 7
Receiver
and transmitter motherboards
Page 12
Power
supply
Page 14
Alignment
Page 15-16-
17
Settings
and programming
Page 18
•
Description of signalling leds ……………………………………………………………………………………………….. 18
•
Jumpers and trimmers description ……………………………............................................................. 19
Fixing the column
Page 8
Tamper
height adjustment, inserting the tube and closing the column
Page 9
Technical
specifications and consumption
Page 20
Additional components
Page 5
Notes
Page 21-22-
23
•
Receiver (RX) …………………………………………………………..…………………………………………………………… 12
•
Transmitter (TX) ……………………….………….….…………………………………………………………………………… 13

GARDEN-TOWER IR Installation and user manual Page 3 of 24
Introduction
and warnings
INTRODUCTION
GARDEN and TOWER IR are the perimeter columns
with crossed beams and double lens.
The GARDEN version is camouflaged as a lamp post
that combines aesthetics with functionality
to a reliable security device. Both pre-cabled and
ready for installation they are composed of a
transmitting and a receiving unit. The transmitter
emits a coded sequence of infrared beams which
are detected by all the receivers. The columns are
supplied with optical synchronization because each
beam is recognized by means of differentiated
optical codes (optical synchronization).
GARDEN and TOWER IR are more suitable for
harsher environments and weather situations
(low temperatures, fog, humidity, wind gusts)
thanks to the built-in automatic temperature
control device, the disqualification system and
sturdy aluminum structure.
WARNINGS
•Use shielded cables.
•Observe the minimum distances between the
TX and RX columns (see table on page 20).
•In areas subject to intense fog, for
distances longer than 80 m, it is advisable
to break the barrier path with an extra
column.
•Power the device using the 13.8 Vdc
stabilised voltage only.
•It is mandatory to switch on the
temperature control system for both
internal and external installations (24Vac).
•The installation should be performed by
qualified personnel.
MITECH is not responsible for damages
and / or barrier malfunctions
caused by incorrect installation
and / or improper use.

GARDEN-TOWER IR Installation and user manual Page 4 of 24
Components
Part
Quantity
Description
1 1 Aluminum support bar
2 1 IR polycarbonate tube
3 1 Upper cap
4 1 Lower cap
5 1 Tamper
6 1 Power supply
(optional)
7 1 Ground fixing base (GAR GR)
or wall fixing bracket (GAR WL)
Boards, optical groups
and heating system
Terminal version RX or TX
Motherboard 1 (RX or TX)
Expansion boards From 1 to 4 (RX or TX)
Tamper boards 1 (RX or TX)
Optical groups From 2 to 5 (RX or TX)
Heating resistors From 2 to 5
Bi-directional version
Motherboard 1 couple
(1 RX + 1 TX)
Expansion boards From 1 to 4 couples
(max 4 RX + 4 TX)
Tamper boards 1 couple
(1 RX + 1 TX)
Optical groups From 2 to 5 couples
Heating resistors From 2 to 5 couples
6
5
2
7
1
3
4

GARDEN-TOWER IR Installation and user manual Page 5 of 24
Accessories
IMAGE CODE DESCRIPTION
GAR GR
(standard)
Base for ground fixing
200 x 210 mm
Ø 33 cm
GAR WL
Bracket for wall mounting
(200 x 210 mm)
GARPOW Dual power supply, 1 for column
(if required it is installed up)
GAR LAMP CO or WH
Globe light fixture with lamp holder (E27)
Diameter: 32 cm
Available colours: white (WH) and cognac (CO)
LUMYA
Embedded light fixture (white colour) with
lamp holder
Height: 25 cm - E27
GAR PRCAP Anti-climbing pressure cap
TW CAMCAP Universal camera support

GARDEN-TOWER IR Installation and user manual Page 6 of 24
General
installation instructions
1.
2.
3.
4.
After installing the column, make sure that it is perfectly closed with the watertight
covers supplied.
Make sure that the path between the sensors is free and that there are no obstacles
that could affect the communication between the optical groups of the transmitters and
receivers (i.e. branches, plants, leaves, etc. that could interfere with the beams).
Verify that the optics of the transmitter and receiver units are not exposed to direct
sunlight at dawn and sunset.
Do not use switching power supplies that might cause electrical disturbances .
Mounting
options
Columns may be mounted in two ways:
- w
ith a specific wall mounting bracket (code: GAR WL)
- w
ith a specific ground mounting base (code: GAR GR)
Wall
mounting (GAR WL bracket)
Drill 4 holes of Ø 8 mm in the wall, level with the bracket fixing holes.
Insert M8 steel gussets (not supplied) and fix the bracket.
20 cm
20 cm
20 cm
FRONT VIEW SIDE VIEW
20 cm
TOP VIEW
Hole for cables passage Ø 32

GARDEN-TOWER IR Installation and user manual Page 7 of 24
Ground
mounting (GAR GR base)
FIXING WITH CLAMPS
This fixing method is the most secure.
Make a cement base in which to anchor the
clamps provided.
It is necessary to use a corrugated pipe Ø 20 mm
for passage of cables.
FIXING WITH
GUSSETS
Drill 3 holes of Ø 8 mm in the ground, level
with the base fixing holes.
Insert M8 steel gussets (not supplied) and
fix the base.
20 cm
20 cm
20 cm
FRONT VIEW SIDE VIEW
20 cm
TOP VIEW
Cables insertion hole Ø 32

GARDEN-TOWER IR Installation and user manual Page 8 of 24
Fixing the column
BRACKET
M6X25
M6X20
LOWER CAP
Insert the lower cap into the base guide.
Insert the aluminium bar into the base
guide and into the relevant slot in the lower
cap.
Insert the connecting bracket between the
lower cap and the aluminum bar.
Screw 2 M6x20 screws through the
bracket and the base and 2 M6x25 screws
through the bracket and the bar.

GARDEN-TOWER IR Installation and user manual Page 9 of 24
Tamper height adjustment, inserting the tube and closing
the column
Tamper height adjustment
Adjust the tamper height using the two
jagged edge washers A and B (see image).
Closing the column
Position the top cover and screw it to the
column using the supplied screws provided
with o-ring.
Inserting the tube
Insert the polycarbonate tube from above,
making it slide down into the slot and
inserting it into the lower cap.
A
B

Installation
solutions
GARDEN-TOWER IR Installation and user manual Page 10 of 24
4
SIDES PERIMETER PROTECTION
With bi
-directional columns
4
SIDES PERIMETER PROTECTION
With terminal
columns
3 SIDES PERIMETER
PROTECTION
With terminal and bi
-directional columns
WARNING: ENSURE THAT THE COLUMNS ARE INSTALLED IN A STRAIGHT ROW
For a correct positioning of the columns, refer to the following diagram
(contact the supplier for more information)
TX RX/TX RX/TX RX
YES
TX RX/TX
RX/TX
RX
NO
TX RX/RX
TX/TX
RX
YES

GARDEN-TOWER IR Installation and user manual Page 11 of 24
Example of protection
The columns come
with crossed beams to ensure maximum protection.
For visibility purposes
, the beams in this drawing are linear.
WARNING
Ensure no interference is caused by the presence of photocells for
automatic gates or infrared cameras, as these may blind the barriers.
COLUMNS
IR BEAMS
TRANSMISSION

GARDEN-TOWER IR Installation and user manual Page 12 of 24
Receiver
and transmitter motherboards
Receiver
(RX)
RES. 9 W –100 Ohm
DETECT
ALM
HTR
POWER
MASK
S.LOW
LEDS
ON OFF
24 Vac
ON
OFF
S.LOWAND
3
4
5
6
7/8
9/10
12 Vdc
+
-
N.C.
N.A.
COM
TMP
TMP
AND
MASK
S.LOW
OUT RELE
LD1
LD2
LD3
LD4
LD5
LD6
FBRX TMP
ST
BEAM
MI-TECH
FLAT CABLE
CONNECTOR
HEATING
RESISTOR
ADJUSTABLE
SPEED
MASKING
SENSITIVITY
THERMAL SENSOR
BEAMS
SELECTOR
Barrier with 2 lenses: no jumper
Barrier with 3 lenses: jumper 3 inserted
Barrier with 4 lenses: jumper 3 and 4 inserted
Barrier with 5 lenses: jumper 3, 4 and 5 inserted
HEATING POWER
SUPPLY 24 Vac
LED1 –S.LOW
(LOW SIGNAL)
LED2 –MASK (MASKING)
LED3 –DETECT (DETECTION)
LED4 –ALM (ALARM)
LED5 –HTR (HEATING)
LED6 –POWER (POWER SUPPLY)
AUTOMATIC FOG DISABLING
ON ACTIVE - OFF NOT ACTIVE
ON/OFF LEDS
AND FUNCTION
ON ACTIVE - OFF NOT ACTIVE
(Default configuration: OR)
POWER SUPPLY +12 V
0 V GND
ALARM RELAY
CONTROL
TAMPER OUTPUT
AND INPUT (0 Volt)
MASKING OUTPUT (OC)
LOW SIGNAL OUTPUT (OC)
DISQUALIFICATION
SPEED
MASK

GARDEN-TOWER IR Installation and user manual Page 13 of 24
Transmitter
(TX)
RES. 9 W –100 Ohm
CLOCK
TEST
HTR
POWER
LEDS
ON OFF
24 Vac
12 Vdc
+
-
TMP
TMP
LD1
LD2
LD3
LD4
FBTX TMP
ST
MI-TECH
FLAT CABLE
CONNECTOR
HEATING
RESISTOR
THERMAL SENSOR
BEAMS
SELECTOR
Barrier with 2 lenses: only jumper 2 inserted
Barrier with 3 lenses: only jumper 3 inserted
Barrier with 4 lenses: only jumper 4 inserted
Barrier with 5 lenses: only jumper 5 inserted
HEATING POWER
SUPPLY 24 Vac
LED2 –TEST MODE
LED3 –HTR (HEATING)
LED4 –POWER SUPPLY
ON/OFF LEDS
POWER SUPPLY +12 V
0 V GND
TAMPER OUTPUT
LED1 –CLOCK
(FLASHING LED)
2
3
4
5
6
7/8
9/10
BEAM
ON
OFF
ALIGNMENT
JUMPER

GARDEN-TOWER IR Installation and user manual Page 14 of 24
Power
supply
Example of power supply connection with GAR POW unit.
With a power supply it is possible to feed a pair of barriers
(RX-TX or RX-RX or TX-TX).
WARNINGS
Always use filtered and stabilized 230 Vac voltage.
Then check the cabling before connecting the power supply
RX
MOTHERBOARDS

GARDEN-TOWER IR Installation and user manual Page 15 of 24
Alignment
1.
2.
3.
Barrier power supply (see page 10)
Check that all the red leds (ALM LEDs) on the
expansion and tamper boards of the RX optics
are all off (Image 1)
If one or more leds are not off, gently adjust the
relevant lenses in a horizontal and vertical
direction towards the transmitters until all the
leds are turned off.
If one or more leds are not turned off, go directly
to the instrumental alignment procedure
described on page 16.
NORMAL
NOISE
TEST LED ALM
T.P.
MI-TECH. RX FEBRX
Image 1
WARNINGS:
Before the instrumental alignment verify the following on the receiver motherboard:
•the blinding led must be switched off
•the AND and S.LOW jumpers must be set to OFF
•the MASK and SPEED trimmer regulation must remain in vertical position
Image 2
VERTICAL
ADJUSTMENT
BY 30°
HORIZONTAL
ADJUSTMENT BY 180°

GARDEN-TOWER IR Installation and user manual Page 16 of 24
Instrumental alignment
1.
Connect the multimeter
to the connector
TP of the most central RX expansion
board using the specific red/black cable
supplied.
2.
Move the TEST jumper on the TX
motherboard to ON
3.
Move the TEST jumper on the first TX
expansion board to ON
MULTIMETER
Measurement
in Vcc
Reference value: approx 4V
Cable
supplied
(red/black)
Led TX
Jumper insertion
Flat cable
NOTES:
a) some multimeters might display a voltage that is up to 50% lower than the real value,
therefore check the tester is working correctly
b) the use of some transceivers to communicate during installation could affect the
multimeter readings
TP
Test Point
NORMAL
NOISE
TEST
T.P.
Alignment
setting

GARDEN-TOWER IR Installation and user manual Page 17 of 24
4.
Manually adjust the optics of the first
lower TX expansion board, towards
the centre of the RX receiving
unit (see image), in order to
display the maximum voltage value
of around 4 Volt on the tester (over 4
Volt the voltage values are to be
considered optimal).
It is important in this phase to
ensure all the red leds on the RX
expansion boards are switched off.
In the event of some or all of the
leds being on, adjust the RX optics
vertically and horizontally and
orient again the TX optics until the
leds switch off.
5.
Set the TEST Jumper to the OFF
mode of the first TX expansion
board at the bottom and repeat from
step 3 the alignment of all the
remaining TX expansion boards.
MULTIMETER
Cable supplied
(red/black)
Measurement in
Vcc
Reference value:
approx 4V
6.
Ensure all the TEST jumpers of the TX motherboard and of the TX expansion boards are
set to OFF.
FINAL TEST:
Double lens version: verify that the barrier triggers an alarm signal when both lenses of
each optical group are covered (OR setting).
Single lens version: verify that the barrier triggers an alarm signal when each lens is
covered (OR setting).
7.
Once the FINAL TEST is finished,
for setting the barrier in AND mode,
it is necessary to set the AND programming
jumper to ON, on the RX motherboard.
IMPORTANT: during the alignment phase,
remember that the AND jumper must always
be set to OFF.
ON
OFF
S.LOWAND
3
4
5
6
7/8
9/10
BEAM
MI-TECH
SPEED
AND MODE
TX RX
Insertion jumper

GARDEN-TOWER IR Installation and user manual Page 18 of 24
Settings
and programming
Description
of signalling leds
The RX board has 6 leds for control purposes which can be enabled or disabled by setting the
jumper to ON.
Led S.LOW: Low signal (DISQUALIFICATION)
It switches ON to indicate the presence of intense fog and the activation of the disqualification
function. In this mode the barrier is deactivated and then automatically restored as soon as the
signal is regained.
It is possible to manage this signal directly in the control panel (O.C. output).
For the correct functioning of the disqualification device it is mandatory to have accomplished a
proper alignment.
Led MASK: Blinding signal and mains anomaly
It switches ON and blinks to signal the presence of an electromagnetic interference or a wiring
problem that may affect the correct functioning of the barrier.
Led DETECT: Irregular transmission signal
This led is generally OFF in ordinary operating conditions. The led blinks if one or more
transmitter signals are not detected by the receivers.
It lights permanently if all the transmitters signals are not detected by the receivers.
Verify alignment and possible blinding problems.
Led ALM: Alarm acknowledgement
It switches ON to signal the occurrence of an alarm.
The tripping delay set on trimmer SPEED ranges from 50 ms to 500 ms (turn the trimmer
clockwise to increase the delay).
Led HTR: Heating
The barriers have an automatic heating system with electronic control that
guarantees a minimum internal temperature of 17°C in all environmental conditions.
If the led is ON, the heating system is working correctly.
POWER: Power supply
The POWER led is the only one that is permanently ON in ordinary operating conditions.

GARDEN-TOWER IR Installation and user manual Page 19 of 24
Jumpers
, trimmers and connector T.P. description
Jumper
BEAM
Number
of beams selector, see diagram on page 12.
Jumper
AND
Inserted
in ON enables the AND function. To have an alarm condition, two random optical
groups
must be interrupted. The function can also be programmed remotely via terminal blocks
(output OC
- 0 Volt).
Jumper
S.LOW: Signal low (DISQUALIFICATION)
Inserted
in ON enables the disqualification function (output OC - 0 Volt).
Jumper
LEDS
Inserted
in ON enables the signal LEDS.
Trimmer SPEED
For
adjusting the tripping time from 50 ms to 500 ms (the delay increases by turning the
trimmer
clockwise).
Trimmer MASK
For
adjusting the sensitivity of the blinding function (the sensitivy increases by turning the
trimmer
clockwise).
RX motherboard
Jumper
BEAM
Number of beams selector, see diagram on page 13.
Jumper
TEST
To use for
alignment, see page 16.
Jumper
LEDS
Inserted
in ON enables the signal LEDS.
TX motherboard
RX
expansion board
Jumper
NORMAL
Do
not change the programming.
Jumper
NOISE
Not
used.
Connector T.P.
Connect the special
red/black cable supplied to the connector T.P. during alignment,
see
page 16.
TX
expansion board
Jumper
TEST
To use
during alignment, see page 16.

GARDEN-TOWER IR Installation and user manual Page 20 of 24
Technical
features and consumption
Technical
features
Maximum
range outdoors
100 m
Minimum
range outdoors
15 m ( For distances of less than 15 m please
contact the supplier).
Barrier height
1.0
m - 1.5 m - 2.0 m - 2.5 m –3,0 m
Synchronization
Optical
Total number of beams
50
crossed
Power supply
12Vdc
Disqualification
Automatic
with external signals
Maximum column
consumption
(5 lenses version)
Tx
120 mA + Rx 270 mA
Maximum heaters absorption
60 W
Operating temperature
–
25°C +70°C
Alignment angle
Vertical: 30
° - horizontal: 180°
Detection system
AND
/ OR on Tx and Rx remote AND
Anti
-
masking
Automatic
, can be disabled
Tripping time
Adjustable
, 50 / 500 ms
Alarm
and tamper output
Contact
NC/NA
Led indicators
Power supply
, anti-masking, heating, low signal, alarm, detection
IR signal
Pulsed coded
Standard compliance
EN 50131
-1 and CEI 79-3
ROhs
compliance
2011/65/UE
Protection class
IP
65
Warranty
3 years
COLUMN TX RX TOTAL CONSUMPTION
TW102D GAR102D 120 mA 110 mA 230 mA
TW102-RX GAR102-RX - 110 mA 110 mA
TW102-TX GAR102-TX 120 mA - 120 mA
TW153D GAR153D 120 mA 150 mA 270 mA
TW153D-RX GAR153D-RX - 150 mA 150 mA
TW153D-TX GAR153D-TX 120 mA - 120 mA
TW204D GAR204D 120 mA 230 mA 350 mA
TW204D-RX GAR204D-RX - 230 mA 230 mA
TW204D-TX GAR204D-TX 120 mA - 120 mA
TW254D GAR254D 120 mA 230 mA 350 mA
TW254D-RX GAR254D-RX - 230 mA 230 mA
TW254D-TX GAR254D-TX 120 mA - 120 mA
TW304D GAR304D 120 mA 230 mA 350 mA
TW304D-RX GAR304D-RX - 230 mA 230 mA
TW304D-TX GAR304D-TX 120 mA - 120 mA
TW305D GAR305D 120 mA 270 mA 390 mA
TW305D-RX GAR305D-RX - 270 mA 270 mA
TW305D-TX GAR305D-TX 120 mA - 120 mA
Consumption