En-9
● OPERATING INSTRUCTIONS ●
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
Theunitcannotbeoperated. • Isthebreakerturnedon?
• Isthepowersupplyplugconnected?
• IstheONtimerset? Page 6
AllLEDlampsontheindoor
unitareblinking.
• Arethehorizontalvanesinstalledcorrectly?
Page 8
Thehorizontalvanedoesnot
move.
• Arethehorizontalvaneandtheverticalvane
installedcorrectly? Page 8
• Isthefanguarddeformed?
Theunitcannotbeoperatedfor
about3minuteswhenrestarted.
•
This protects the unit according to instruc-
tionsfromthemicroprocessor.Pleasewait.
Mist is discharged from the air
outletoftheindoorunit.
• Thecoolairfromtheunitrapidlycoolsmois-
ture in the air inside the room, and it turns
intomist.
Theswingoperationofthe
HORIZONTALVANEis
suspendedforawhile,then
restarted.
• ThisisfortheswingoperationoftheHORI-
ZONTALVANEtobeperformednormally.
Theairowdirectionchanges
duringoperation.
Thedirectionofthehorizontal
vanecannotbeadjustedwith
theremotecontroller.
• When the unit is operated in COOL or DRY
mode, if the operation continues with air
blowingdownfor0.5to1hour,thedirection
oftheairowisautomaticallysettohorizon-
talpositiontopreventwaterfromcondensing
anddripping.
• Intheheatingoperation,iftheairowtem-
peratureistooloworwhendefrostingisbe-
ingdone,thehorizontalvaneisautomatically
settohorizontalposition.
Theoperationstopsforabout
10 minutes in the heating
operation.
• Outdoorunitisindefrost.
Since this is completed in max. 10 minutes,
pleasewait.(Whentheoutside temperatureis
toolowandhumidityistoohigh,frostisformed.)
Theunitstartsoperationby
itselfwhenthemainpoweris
turnedon,butisn’treceived
signfromtheremotecontrol-
ler.
• Thesemodelsareequippedwithanautore-
startfunction.Whenthemainpoweristurned
offwithoutstoppingtheunitwiththeremote
controller and is turned on again, the unit
startsoperationautomatically in the same
modeastheonesetwiththeremotecontrol-
lerjustbeforetheshutoffofthemainpower.
Referto“Autorestartfunction” Page 7 .
Theindoorunitdiscolorsover
time.
• Althoughplasticturnsyellowduetotheinu-
enceofsomefactorssuchasultravioletlight
and temperature, this has no effect on the
productfunctions.
Outdoor Unit
The fan of the outdoor unit
does not rotate even though
thecompressorisrunning.
Even if the fan starts to rotate,
itstopssoon.
• Whentheoutsidetemperatureislowduring
coolingoperation,thefanoperatesintermit-
tentlytomaintainsufcientcoolingcapacity.
Waterleaksfromtheoutdoor
unit. • During COOL and DRY operations, pipe or
pipeconnectingsectionsarecooledandthis
causeswatertocondense.
• Intheheatingoperation,watercondensed
ontheheatexchangerdripsdown.
• In the heating operation, the defrosting
operationmakesiceformingontheoutdoor
unitmeltanddripdown.
Whitesmokeisdischarged
fromtheoutdoorunit. •
Intheheatingoperation,vapor generatedby
thedefrostingoperationlookslikewhitesmoke.
Remote controller
Thedisplayontheremote
controllerdoesnotappearor
itisdim.Theindoorunitdoes
not respond to the remote
controlsignal.
• Arethebatteriesexhausted? Page 4
• Isthepolarity(+,-)ofthebatteriescorrect?
Page 4
• Areanybuttonsontheremotecontrollerof
otherelectricappliancesbeingpressed?
Symptom Explanation & Check points
Does not cool or heat
Theroomcannotbecooled
orheatedsufciently. • Is the temperature setting appropriate?
Page 5
• Isthefansettingappropriate?Pleasechange
fanspeedtoHighorSuperHigh. Page 6
• Aretheltersclean? Page 8
• Isthefanorheatexchangeroftheindoorunit
clean? Page 8
• Arethereanyobstaclesblockingtheairinlet
oroutletoftheindoororoutdoorunit?
• Isawindowordooropen?
• Itmaytakeacertaintimetoreachthesetting
temperatureor maynot reach that depending
onthesizeoftheroom,theambienttempera-
ture,andthelike.
Theroomcannotbecooled
sufciently.
• When a ventilation fan or a gas cooker is
usedinaroom,thecoolingloadincreases,
resultinginaninsufcientcoolingeffect.
• When the outside temperature is high, the
coolingeffectmaynotbesufcient.
Theroomcannotbeheated
sufciently.
• When the outside temperature is low, the
heatingeffectmaynotbesufcient.
Airdoesnotblowoutsoonin
theheatingoperation.
• Pleasewaitastheunitispreparingtoblow
outwarmair.
Poorcoolingorheating
performance.
• Doyouhaveanarrangementwithyourelec-
triccompanyforDemandResponse?
Airow
The air from the indoor unit
smellsstrange.
• Aretheltersclean? Page 8
• Isthefanorheatexchangeroftheindoorunit
clean? Page 8
• Theunitmaysuckinanodoradheringtothe
wall,carpet,furniture,cloth,etc.andblowit
outwiththeair.
Sound
Crackingsoundisheard. • This soundisgenerated bytheexpansion/
contraction of the front panel, etc. due to
changeintemperature.
“Burbling”soundisheard. • Thissoundisheardwhentheoutsideairis
absorbedfromthedrainhosebyturningon
therangehoodortheventilationfan,making
waterowinginthedrainhosetospoutout.
Thissoundisalsoheardwhentheoutsideair
blowsintothedrainhoseincasetheoutside
windisstrong.
Mechanicalsoundisheard
fromtheindoorunit.
• Thisistheswitchingsoundinturningoff/on
thefanorthecompressor.
Thesoundofwaterowing
isheard. • This is the sound of refrigerant or condensed
waterowingintheunit.
Hissing sound is sometimes
heard.
• Thisisthesoundwhentheowofrefrigerant
insidetheunitischanged.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• Whenwaterleaksordripsfromtheindoorunit.
• Whentheupperoperationindicatorlampblinks.
• Whenthebreakertripsfrequently.
• TheremotecontrolsignalisnotreceivedinaroomwhereanelectronicON/
OFFtypeuorescentlamp(inverter-typeuorescentlamp,etc.)isused.
• OperationoftheairconditionerinterfereswithradioorTVreception.Anampli-
ermayberequiredfortheaffecteddevice.
• Whenanabnormalsoundisheard.
• Whenanyrefrigerantleakageisfound.
JG79Y822H02_en.indd 9 2021/03/25 8:58:17