Installation Requirements
NOTE: It is most important that this salamander is installed correctly and that operation is correct before use. Installation
shall comply with local gas, health and safety requirements.
Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best
performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National /
Local codes covering gas and fire safety.
Australia / New Zealand: - AS/NZS5601 - Gas Installations.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 - 1 & 2 Installation Flueing & Ventilation.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install equipment to the relevant codes
and manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only to be adjusted by a
qualified service person. They are not to be adjusted by the installation person.
Unpacking
Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel
panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located on front bottom corner of right hand side panel.
Check the following parts have been supplied with appliance:
Location
1. Installation must allow for sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion products.
3. This appliance must be mounted onto a non-combustible wall or tailored stand, using rear wall bracket and spacing screws
provided.
4. Combustible walls must not protrude past front of appliance.
5. This appliance must not be mounted on a combustible surface or metal surface, as radiated heat will cause these surfaces to
become extremely hot.
6. Caution should be taken as intense heat is emitted at bottom front of appliance.
7. Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be adjusted by an authorised service
agent. They are not to be adjusted by the installation person.
8. The unit should be mounted under an extraction hood in compliance with all local regulations.
If the unit is not mounted under an extraction hood, the installer must ensure that all regulations are met and that
there is an unobstructed minimum distance of 750mm from top surface of unit to ceiling, which must be of non-
combustible material.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to appliance flue outlet.
1 x Salamander Rack. 1 x Wall Mounting Bracket, including;
1 x Trough Tray. - 2 x 25mm Black Plastic Spacers.
1 x Gas Regulator. - 2 x 3/8” Bolts / Nuts.
1 x Alternate Gas Conversion Kit.
Combustion Air Requirements:
Natural Gas 9 m3/hr
LP Gas / Butane 9 m3/hr
Town Gas 9 m3/hr