manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Moldex
  6. •
  7. Respiratory Product
  8. •
  9. Moldex 3000 NR Series User manual

Moldex 3000 NR Series User manual

This manual suits for next models

1

Other Moldex Respiratory Product manuals

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 7000 Series Operator's manual

Moldex

Moldex 7000 Series Operator's manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 0073-1 User manual

Moldex

Moldex 0073-1 User manual

Moldex 9001 Operator's manual

Moldex

Moldex 9001 Operator's manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Classic+ FFP Series Instruction Manual

Moldex

Moldex Classic+ FFP Series Instruction Manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 2380 User manual

Moldex

Moldex 2380 User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Bitrex Fit Test Kit User manual

Moldex

Moldex Bitrex Fit Test Kit User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Air Series User manual

Moldex

Moldex Air Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Smart Pocket FFP1 NR D Instruction manual

Moldex

Moldex Smart Pocket FFP1 NR D Instruction manual

Popular Respiratory Product manuals by other brands

Dräger PSS Series Instructions for use

Dräger

Dräger PSS Series Instructions for use

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

Dräger saver PP Series Instructions for use

Dräger

Dräger saver PP Series Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.moldex.com
Datasheet
FFP masks
Protection against Dust, Mist & Fumes
EU - 01 - 2010 / 01
CERTIFICATION
The Moldex Series 3000 FFP-masks meet the requirements of EN149:2001 +
A1:2009 and are CE-marked in accordance with the requirements of European Di-
rective 89/686/EEC. The BGIA Germany is responsible for both type examination
(Article 10) and monitoring of production (Article 11).
The products are manufactured in an ISO 9001:2000 certified plant.
MATERIALS
Filter Layer, Inner Shell, DuraMesh®: Polypropylene,
Ethylene-vinyl acetate (EVA)
Cusion Seal: TPE
Head Strap: Polyester, Natural Rubber
Ventex®-valve: Natural Rubber
WEIGHT
3505: 42 g
AREAS OF USE
(WEL = Workplace Exposure Limit)
Series 3000 NR (3505)
CHARACTERISTICS
ActivForm®
Automatically fits to the face.
No manual adjustments by the user are necessary.
DuraMesh®
Masks have a strong and durable structure.
Ventex®-valve
Starts to open even at low exhalation pressure and
significantly reduces moisture and heat inside the mask.
Low breathing resistance
Pleated filter technology reduces inhalation resistance by up
to 50% whilst maintaining filtration performance.
Full face seal
3D face seal – like a rubber half mask – improves fit
and provides optimum wearing comfort.
Adjustable Clip
Easy on & off; Adjustable strap for optimal fit and
wearer comfort.
100% PVC-FREE
All Moldex products and packaging are
completely free from PVC.
NR (non reusable) = Single use.
Comfortable and durable throughout the whole shift
FFP3 NR
3505 with Ventex®-valve
Level WEL Hazard type
Examples
FFP3 20 x FINE TOXIC DUSTS, FUMES, WATER AND OIL BASED
MISTS/AEROSOLS
As FFP2 but at higher concentrations, plus: Ceramic Fibres,
Chromates, Chromium, Cobalt, Nickel, Micro Organisms,
radioactive and biochemical active Aerosols
www.moldex.com
TESTING ACCORDING TO EN 149:2001 + A1:2009
Total inward leakage
Ten test subjects perform a variety of exercises. During the exercises the amount
of test aerosol that penetrates the filter, face seal and valve are sampled. The
total inward leakage of 8 out of 10 test subjects shall not exceed the following
levels:
The filter penetration after loading the filter with 120 mg paraffin oil according
to DIN EN 149:2001 + A1:2009 shall not exceed the following levels:
Flammability
4 respirators are passed through a 800°C (+/- 50°C) flame with a speed of 6 cm/s.
After passing through the flame the respirator has to self-extinguish.
Breathing Resistance
Thebreathingresistanceproducedbythefilteroftherespiratoristestedatanairflowof
30 l/min and 95 l/min.
INSTRUCTIONS FOR USE
· The user has to be trained and instructed in wearing the mask.
· FFP masks do not protect against gases and vapours.
· The oxygen concentration of the ambient atmosphere should be at 19,5 % Volume.
· These respirators may not be used if the concentration type, and properties of
contaminants in the ambient atmosphere are unknown or at dangerous levels.
· Respirators should be disposed if damaged, if the breathing resistance
becomes high due to clogging.
· Never tamper with, alter or modify the respirator.
INSTRUCTIONS FOR FITTING
EU - 01 - 2010 / 02
Datasheet
FFP masks
Protection against Dust, Mist & Fumes
Category max. breathing resistance
30 l / min 95 l / min
FFP3 1,0 mbar 3,0 mbar
1.
2. Fasten the two pieces buckles
at the back of the neck.
3. Place respirator on chin and
lift upper strap to place on
back of neck.
4. Ensure respirator fits secure
and comfortable. To fasten
respirator pull strap at either
side of the buckle.
5. Unbuckle to take off. During
work breaks open the buckles
and let the mask hang around
the neck.
Category FFP3
max. total inward leakage 2 %
Category FFP3
max. Filter penetration 1 %
INFO
For help on selection and training please
contact us. We offer a wide range of training
packages and support material.
MOLDEX-METRIC AG & Co. KG
Tübinger Straße 50
72141 Walddorfhäslach
Germany
Tel.: +49 (0) 71 27/81 01-02
Fax: +49 (0) 71 27/81 01-48
[email protected]