manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Moldex
  6. •
  7. Respiratory Product
  8. •
  9. Moldex 9000 Series User manual

Moldex 9000 Series User manual

EASY TO WEAR
At less than 13 ounces, the 9000 Series respirator is
ultra-lightweight. Workers will appreciate the comfort and
longer wearability and employers will benefit from increased
user acceptance.
ON & OFF MADE EASY
A convenient ratchet fastening strap system and the
stand-away head harness make donning and doffing the
9000 mask quick and easy. The strap tabs are securely
molded directly to the flange for rugged use.
A FRAMELESS MASK WITH A VIEW
The 9000 has an extra-wide viewing lens, with an exclusive
over-molded flange design. This eliminates the traditional
clamping frame found on most other face pieces.
COMPLETELY METAL-FREE
The 9000 is completely metal-free, making it ideal for mines,
refineries and other work environments where metal may be
hazardous.
MAINTENANCE HAS NEVER BEEN EASIER
Advanced design eliminates unnecessary parts. Our
over-molded flange and harness tabs, plus integrated
exhalation assembly, make cleaning and maintaining the
9000 Series respirator a breeze.
FEATURES
• High-tech, streamlined design for exceptional worker
acceptance.
• Exclusive over-molded lens offers greater field of vision.
• Lighter weight for superior all-day comfort.
• Fewer parts means less cost and easy maintenance.
• Stand-away head harness for easy donning and doffing.
• Lens stays away from flat surface when laid down to
avoid scratching.
• Tear away lens protector included.
• Lens meets ANSI Z87+ for high impact requirements.
• 100% PVC-Free for a greener alternative.
9000SERIES
REUSABLE RESPIRATORS
9000-807 REV B 1/19
®
PART # / DESCRIPTION SIZE DISPLAY CASE
9001 Full Facepiece S 1 per Box 2 Boxes
9002 Full Facepiece M 1 per Box 2 Boxes
9003 Full Facepiece L 1 per Box 2 Boxes
9000SERIES
REUSABLE RESPIRATORS
MOLDEX-METRIC, INC.
10111 Jefferson Blvd.
Culver City, CA 90232
TEL: +1 (800) 421-0668 or
+1 (310) 837-6500
FAX: +1 (310) 837-9563
E-mail: [email protected]
www.moldex.com
CANADIAN CUSTOMER SERVICE
Tel: +1 (800) 421-0668, Ext. 550
Fax: +1 (310) 837-9563
USE AGAINST:
1. Contaminants specified on NIOSH approval label, matrix, cartridges or filters and
in accordance with all limitations and applicable safety and health regulations,
including OSHA.
2. Contaminants with good warning properties, i.e., smell, taste or irritation.
DO NOT USE AGAINST:
1. Concentrations of contaminants which are unknown, or are immediately dangerous
to life or health.
2. Concentrations of contaminants which exceed the maximum use concentration or
10X the OSHA Permissible Exposure Limit, (PEL), when qualitatively fit tested, or 50X
the PEL when quantitatively fit tested, or according to applicable government
regulations.
3. Gases or vapors with poor warning properties or those which generate high heats of
reaction, or paint sprays containing isocyanates.
4. Sandblasting.
5. Oil-based mists with N filters.
RESTRICTIONS:
01. This respirator does not supply oxygen and must not be used in atmospheres
containing less than 19.5% oxygen.
02. Do not remain in contaminated area if any physical distress occurs, for example
breathing difficulty, dizziness or nausea.
03. Leave contaminated area and replace respirator and/or cartridge or filter if it is
damaged, distorted, a proper fit cannot be obtained, you taste, smell or become
irritated by contaminants, or breathing becomes difficult.
04. Do not alter, modify, or abuse this respirator.
05. Store respirator in sealed bag in a clean, dry, non-contaminated area.
06. Dispose of facepiece, and/or cartridges and disks/filters according to your
employer’s policy and applicable regulations.
07. N, R or P filters are required for particulates.
08. Where oil mists are present, either alone or in combination with solid particulates,
do not use the R or P filters for longer than one eight-hour work shift. Dispose no
later than eight hours after first use. Do not exceed 10x PEL or a total of 200 mg
loading per respirator, whichever is lower. It is the user’s responsibility to know the
PEL and concentration of the contaminant, the maximum work rate of the
employee, and any other work site-specific information to calculate the loading of
the filter. Where oil mists are present do not use N filters.
09. Dispose of all cartridges, N, R, P filters no later than thirty days after a) first use,
and/or b) removing from sealed bag.
10. Use cartridges, filters, and facepieces before the “use by” expiration date printed on
box or bag.
LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER
This limited warranty is made in lieu of the warranties of merchantability, fitness for
particular purposes and all other warranties, express or implied. There are no other
warranties which extend beyond the description on the face hereof. The physical
standards and specifications of Moldex will be met by products sold. Exclusive
Remedies: damages for the breach of this limited warranty are limited to the replace-
ment of such quantity of Moldex, products proved to be defectively manufactured.
Except as provided above, Moldex shall not be liable or responsible for any loss,
damage, or liability, direct, indirect, incidental, special, or consequential, arising out of
sale, use, or misuse, or the inability to use products by the user.
MOLDEX TECHNICAL ASSISTANCE
For more information call +1 (800) 421-0668 or +1 (310) 837-6500, ext. 512/550 or
E-mail: [email protected], [email protected] or visit www.moldex.com.
DISTRIBUTED BY:
IMPORTANT NOTICE TO USERS
You are responsible to understand and follow all warnings, restrictions and
other information contained in the instruction manual before you enter a
contaminated work area. Failure to do so may result in sickness or death.
WARNING TO USER
1. Follow all instructions and warnings on the use of this respirator and wear
during all times of exposure. Failure to do so will reduce respirator
effectiveness, wearer protection, and may result in sickness or death.
2. For proper use, ask your supervisor or call +1 (800) 421-0668 or
+1 (310) 837-6500, ext. 512/550.
3. The user must first be trained by the employer in proper respirator use, in
accordance with applicable safety and health standards, for the
contaminant and exposure level in the assigned work area. A written
Respiratory Training Program must be in place and followed by each user
before first use. It must meet all requirements of all applicable standards,
including OSHA 29 CFR 1910.134, and in Canada CSA Z 94.4, e.g.
training, fit testing, medical evaluation, and applicable OSHA substance
specific standards.
4. The vapors, gases, dusts, mists, fumes, and other contaminants which
can be dangerous to your health include those which you cannot see,
taste, or smell.
5. Check with your supervisor for the appropriate cartridges and/or filters for
the contaminants in your work area.
6. A qualitative or quantitative fit test must be performed before a respirator
is assigned. Refer to current OSHA 29 CFR 1910.134 (f).
7. This respirator facepiece, when combined with any nuisance level organic
vapor and/or acid gas/particulate filter disk, may not be used for organic
vapor or acid gas contaminants exceeding their respective OSHA
Permissible Exposure Limit (PEL) or other government Occupational
Exposure Limits (OEL), whichever is lower. Nuisance level refers to
concentrations not exceeding the PEL or OEL, whichever is lower.
I
S
O
9
0
0
1
:
2
0
1
5
R
E
G
I
S
T
E
R
E
D
®

Other manuals for 9000 Series

2

This manual suits for next models

3

Other Moldex Respiratory Product manuals

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Bitrex Fit Test Kit User manual

Moldex

Moldex Bitrex Fit Test Kit User manual

Moldex Air Series User manual

Moldex

Moldex Air Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Classic+ FFP Series Instruction Manual

Moldex

Moldex Classic+ FFP Series Instruction Manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 0073-1 User manual

Moldex

Moldex 0073-1 User manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 2380 User manual

Moldex

Moldex 2380 User manual

Moldex 7000 Series Operator's manual

Moldex

Moldex 7000 Series Operator's manual

Moldex 9001 Operator's manual

Moldex

Moldex 9001 Operator's manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex Smart Pocket FFP1 NR D Instruction manual

Moldex

Moldex Smart Pocket FFP1 NR D Instruction manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 3000 NR Series User manual

Moldex

Moldex 3000 NR Series User manual

Popular Respiratory Product manuals by other brands

Dräger X-plore 5500 Instructions for use

Dräger

Dräger X-plore 5500 Instructions for use

Dräger X-plore 1700 Instructions for use

Dräger

Dräger X-plore 1700 Instructions for use

NEWMED Levita instructions

NEWMED

NEWMED Levita instructions

Samsung Healthy Living CND-501S instruction manual

Samsung

Samsung Healthy Living CND-501S instruction manual

PHILIPS Respironics Sami The Seal manual

PHILIPS Respironics

PHILIPS Respironics Sami The Seal manual

Rossmax NA100 instruction manual

Rossmax

Rossmax NA100 instruction manual

3M Calibration Kit 529-04-48 instructions

3M

3M Calibration Kit 529-04-48 instructions

CleanSpace CS302 User instructions

CleanSpace

CleanSpace CS302 User instructions

RELAXUS AromaPro 517202 user manual

RELAXUS

RELAXUS AromaPro 517202 user manual

ELMASLAR CN01 user manual

ELMASLAR

ELMASLAR CN01 user manual

e-breathe Multimask Pro instruction manual

e-breathe

e-breathe Multimask Pro instruction manual

Citizen CNC701 manual

Citizen

Citizen CNC701 manual

Kimberly-Clark Jackson R60 AIRMAX ELITE User instructions

Kimberly-Clark

Kimberly-Clark Jackson R60 AIRMAX ELITE User instructions

Honeywell NORTH 7600 Series Operating and maintenance instruction manual

Honeywell

Honeywell NORTH 7600 Series Operating and maintenance instruction manual

BMC 3B Siesta user manual

BMC

BMC 3B Siesta user manual

Air Liquide Respireo Primo F user guide

Air Liquide

Air Liquide Respireo Primo F user guide

Airport 705-425 instruction manual

Airport

Airport 705-425 instruction manual

PowerTraveller DEFENDER user guide

PowerTraveller

PowerTraveller DEFENDER user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.