Before testing the unit, make sure that all bolts are tightened, the test bench is not damaged and
has no cracks. 6.1 A T
• Install the unit must on the mounting face.
• The pulley must align with the belt.
• Release the chain to the required length (by pressing the button Chain release on the control
panel), latch the chain over the chain fixer (1) of the mounting face.
• Fix the unit on the mounting face (by pressing the button Tighten chain on the control panel).
Tightening will stop automatically.
• Release the belt to the required length (by pressing the button Belt release), latch the belt over
an alternator pulley. Tighten the belt (by pressing the button Tighten belt) until tension of the belt
is the same as in the car. Belt tension is set manually. Belt tension stops by pressing the button
Tighten belt one more time.
• Connect the power cable (Fig. 2) B- with multi-functional tightening, called ‘crocodile’, to the body
of the tested unit, which is earth, connected to negative terminal of the battery.
• Press the button Alternator & Starter tester, set required voltage with 12V/24V buttons, according
to the technical characteristics of a tested alternator.
• Connect B+ wire (Fig. 2) to the power terminal of an alternator.
• Connect terminals of a voltage regulator to the corresponding sockets of the test bench.
• Press the button of the corresponding terminal on the control panel, according to the connection
terminal of an alternator.
• Rotate the adjustment knob ROTATION SPEED to the left or to the right, depending on rotation
direction of an alternator. Mostly alternators rotate to the left.
• Faultless alternator starts power generation from 700 to 850 drive rotation.
• If voltage regulator connection terminals are P-D, С, RLO, SIG, СОМ, F(67), set preliminary generation
voltage with the adjustment knob REGULATION GC from 13.5V to 14.5V.
• Reach 3 000 rpm maximum drive rotation.
• Increase the load on an alternator. Rotate the adjustment knob ELECTRICAL LOAD clockwise;
anticlockwise rotation decreases the load.
• If voltage regulator connection terminals are L or D+, generation voltage must not go lower than
13.5V under maximum load, and must not go higher than 14.5V under minimum load.