General
DECOR SERIES RADIATOR
Installation Guide
Connections: 4 - 1/2" B.S.P. (British Standard Pipe) 2 per side
Maximum positive operating pressure: Standard design: 72 psi
Maximum positive operating pressure: High-pressure design: 116 psi
Maximum operating temperature: 230° F
rectangular steel tubes, 2-3/4"x7/16"x16 ga.
rectangular steel tubes, 2-3/4"x7/16"x14 ga.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
A variety of matching valves and other accessories are available and recommended from MYSON. For
specific applications see our detailed installation and technicals manuals and price book which are
available on our web site.
It is assumed that the installer has the appropriate technical knowledge related to building codes,
standard trade practices, and proper use of the tools of the trade.
Myson radiators should only be used with recirculation pump closed loop hydronic heating systems such as 2 pipe
reverse return, 2 pipe direct return, 1 pipe monoflo or homerun piping systems. Series loop piping is not
recommended. Myson radiators are not for use in gravity or steam systems. Position your radiator away from your
circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could
draw air into the system. The suggested location for your Myson radiator, where possible, is below a window
where it can minimize downdrafts from glazed areas. Mounting the radiator a minimum of 4 inches off the floor
willaprovideaforaadequateaconvection.aa(33/16"aminimumafora2Habaseboard)
Myson radiators are supplied with drain plugs, vent plugs, and mounting brackets.
Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and
property damage NOT covered under the Myson Warranty.
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.
Step 3 Shut off and drain the system while the water is still hot.
Step 4 Refill the system.
Step 5 Reheat, vent, and balance the system.
Step 6 Once the Décor Radiator is filled with water the system should be left filled.
Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking
radiators internally.
SYSTEM START-UP
MAINTENANCE & CLEANING
1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your
Myson radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty.
DESIGN AND LAYOUT CONSIDERATIONS:
NOTE! For optimum performance connect the supply to the top and the return to the bottom of the opposite side. Bottom
supply and return will result in a 5% reduced heat output. (See online manual for detailed piping diagrams.)
VALVE ROUGH-IN: When using Myson radiator valves to install your radiator add the following distance from
the end of the radiator to the center of your Supply/Return pipe for each valve.
For 2TRV1/2AN and LKD16AN valves add 1-3/4" --- For 2TRV1/2IN and FF16LAC/FF16WAC valves add 1-5/8"
MOUNTING: Myson horizontal radiators 3H to 11H are supplied with welded mounting lugs located 6-15/16" in
from each end. Myson vertical radiators V11 are supplied with welded mounting lugs located 4-1/4" in from
each end (top and bottom). Pedestal style radiators H34 are supplied with adjustable height stands. Myson
baseboard style radiators 2H are supplied with the appropriate number of brackets for each length. (See
Mounting Detail Supplement for more information)
For more detailed bracket installation dimensions and mounting positions please consult the
detailed installation manual available at MysonComfort.com and/or the assembly instructions
included with the mounting brackets.
SAFETY PRECAUTIONS
Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The
temperature of a radiator is dependent on the temperature of the system water, as set by the system installer
or user. Installers and users should take all necessary steps to minimize the risks of burns. If the risk is
significant, consideration should be given to installing low surface temperature radiators, or to placing guards in
front of the radiators.
For the correct installation of radiators it is essential that the mounting of the radiator to the wall is carried out
in such a way that it is suitable for intended use AND predictable misuse.
VENT LOCATION: The radiator vent should be located on the return side of the radiator at the top tapping.
DECOR
10
10
10
MAR 2016
Horizontal & Vertical design, H & V models
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Side Connections:
All Dimensions are nominal
H34 Pedestal
6-7/8"
1-7/8"
H11
1"
H22
1-7/8"
3-11/16"
2-11/16"
8-7/16"
5-5/8"
11-1/4"
16-15/16"
22-5/8"
31-1/8"
Overall Heights Overall Lengths
2-11/16"
V11
78-3/4"
V11
1"
3/16"
3/16"
2-11/16"
13/16" Typical
Overall Length
76-3/4"
5-5/8" 1/2" BSP 489 351
2H11
Height
Model 1600F1400F1800F
3H11 8-7/16" 1/2" BSP 618 443
627
791
8H11
11H11
6H22
8H22
11H22
2H34
4H11
6H11
11-1/4" 1/2" BSP
16-15/16" 1/2" BSP
22-5/8" 1/2" BSP
31-1/8" 1/2" BSP
16-15/16" 1/2" BSP
22-5/8" 1/2" BSP
31-1/8" 1/2" BSP
ADJUSTABLE
PEDESTAL 1/2" BSP
985 769 552
1,466 1,143 821
1,778 1,387 996
2,106 1,663 1,197
2,740 2,137 1,535
3,848 3,001 2,155
2,026 1,580 1,135
1,818
2,532
3,246
Btuh/FT at Listed AWT and EAT of 700 F.
W
4" Minimum
X
1-3/4"
3-3/8"
V11
H11/H22
H34
Measurement X:
chosen distance
between the wall or
window surface and
the back of the
convector.
6-9/16"
6-7/8" X
3-1/2"
3-3/16"
Min
1-7/16"
3-1/8"
2H11BB
558
1700F
705
877
1,305
1,582
1,885
2,439
3,425
1,803
2,889
420
1500F
531
661
982
1,191
1,442
1,836
2,578
1,357
2,175
282
1300F
357
444
660
800
976
1,234
1,732
912
1,461
213
1200F
271
336
498
605
755
933
1,309
689
1,104
5.25
Weight
(lbs/ft)
7.62
9.75
13.34
17.57
22.54
24.82
32.94
42.38
16.08
.09
Wtr Content
gals/ft
.13
.18
.26
.36
.49
.54
.72
.99
.26
5V11
6V11
8V11
10V11
78-3/4" 1/2" BSP
1/2" BSP
1/2" BSP
1/2" BSP
4,009 3,127 2,245
4,018 3,134 2,250
4,018 3,134 2,250
2,247
3,130
4,013
3,568
3,576
3,576
3,572
2,686
2,692
2,692
2,689
1,804
1,808
1,808
1,806
1,363
1,366
1,366
1,365
49.52
49.52
49.52
49.52
1.12
1.12
1.12
1.12
4H34 1/2" BSP 2,593 1,862
2,959 2,228 1,497 1,132 31.20 .54
**100 **120 **140 **160 **180 **200 **220 **240
23-5/8" 31-1/2" 35-7/16"35-7/16" 47-1/4" 55-1/8" 63" 70-7/8" 78-3/4" 86-5/8" 94-1/2"
Model Length **060 **080
Nominal Length
**090 **300
118-1/8"
39-3/8"
(cm)
(in)
3,324
5V11 6V11 8V11 10V11
14-1/8" 16-15/16" 22-5/8" 28-1/4"
VERTICAL
MODELS
ADJUSTABLE
PEDESTAL
78-3/4"
78-3/4"
78-3/4"
Connections
2 per side
DECOR SERIES Specification Data
X
Mounting
Bracket
3
Dimension (in) Dimension (in)
XWW
Type H11 Type H22
15/16 47/831/16
33/8111/16 51/437/16
KOM (BH)
Short Side*
KOM (BH)
Long Side*
* From wall to radiator

This manual suits for next models

15

Other Myson Heater manuals

Myson 7-4 User manual

Myson

Myson 7-4 User manual

Myson HEK User manual

Myson

Myson HEK User manual

Myson FINESSE User manual

Myson

Myson FINESSE User manual

Myson iV080 User manual

Myson

Myson iV080 User manual

Myson FINESSE User manual

Myson

Myson FINESSE User manual

Myson Kickspace 500 User manual

Myson

Myson Kickspace 500 User manual

Myson WHISPA III 5000 User manual

Myson

Myson WHISPA III 5000 User manual

Myson WHISPA III 9000 WM User manual

Myson

Myson WHISPA III 9000 WM User manual

Myson Kickspace 500 Operating and maintenance manual

Myson

Myson Kickspace 500 Operating and maintenance manual

Myson HI-LINE RC 7-4 User manual

Myson

Myson HI-LINE RC 7-4 User manual

Myson Kickspace 500E ECO Installation instructions

Myson

Myson Kickspace 500E ECO Installation instructions

Myson Finesse EC Quick guide

Myson

Myson Finesse EC Quick guide

Myson KICKSPACE 500 DUO Installation instructions

Myson

Myson KICKSPACE 500 DUO Installation instructions

Myson SLIM-LINE RC User manual

Myson

Myson SLIM-LINE RC User manual

Myson TS4 User manual

Myson

Myson TS4 User manual

Myson Kickspace 500E User manual

Myson

Myson Kickspace 500E User manual

Myson 40G User manual

Myson

Myson 40G User manual

Myson Rio User manual

Myson

Myson Rio User manual

Myson SELECT Quick start guide

Myson

Myson SELECT Quick start guide

Myson RIO Series User manual

Myson

Myson RIO Series User manual

Myson 2-Pipe User manual

Myson

Myson 2-Pipe User manual

Myson Kickspace 500E ECO Installation instructions

Myson

Myson Kickspace 500E ECO Installation instructions

Myson FINESSE User manual

Myson

Myson FINESSE User manual

Myson Kickspace 500 Installation instructions

Myson

Myson Kickspace 500 Installation instructions

Popular Heater manuals by other brands

Logik L15CFS10 instruction manual

Logik

Logik L15CFS10 instruction manual

Empire SR-10T-2 Installation instructions and owner's manual

Empire

Empire SR-10T-2 Installation instructions and owner's manual

Malmbergs OR02-7 instruction manual

Malmbergs

Malmbergs OR02-7 instruction manual

Beurer UB 90 Instructions for use

Beurer

Beurer UB 90 Instructions for use

Trotec TDS 10 M Original instructions

Trotec

Trotec TDS 10 M Original instructions

Prem-I-Air EH1434 manual

Prem-I-Air

Prem-I-Air EH1434 manual

Radiant HL2-DS-30-65 installation manual

Radiant

Radiant HL2-DS-30-65 installation manual

TVS Kiro 5 Mounting instruction

TVS

TVS Kiro 5 Mounting instruction

DS Produkte EL17009-00100 instructions

DS Produkte

DS Produkte EL17009-00100 instructions

Argo Wally operating instructions

Argo

Argo Wally operating instructions

Solight IR01 quick start guide

Solight

Solight IR01 quick start guide

Costway EP25150US-SL user manual

Costway

Costway EP25150US-SL user manual

GSi 2000 Series installation instructions

GSi

GSi 2000 Series installation instructions

uniwatt UHCB user guide

uniwatt

uniwatt UHCB user guide

Soleus Air MS-12 user manual

Soleus Air

Soleus Air MS-12 user manual

AKO AKO-TOLVA-5M2 instructions

AKO

AKO AKO-TOLVA-5M2 instructions

Proheat X45 plus Owner's handbook

Proheat

Proheat X45 plus Owner's handbook

Imetec S0101 operating instructions

Imetec

Imetec S0101 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.