Minimum clearance to combustible construction
from replace and vent surfaces:
f
21
3
/
1
/
inches
-
Maximum input is 26,000 BTU/hr for both natural
-
high altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft. Maximum output for natural gas
pressure is 4.5 inches water column for natural gas and 11
incheswatercolumnforpropane.Maximuminletgaspressure
is 7 inches water column for natural gas and 13 inches water
is3.5incheswatercolumnfornaturalgasand10incheswater
column for propane.
sitting room installations and is suitable for mobile home
installation. The natural gas model can only be installed in
a mobile home that is permanently positioned on its site and
fueled with natural gas.
FIGURE 1
-
to conform with local
codes. Installation practices vary from region to region and it
for example: in Massachusetts State:
gas log.
• A carbon monoxide detector is required in all rooms containing
• The appliance off valve must be a “T” handle gas cock.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed
commonwealth of Massachusetts.
In absence of local codes, install to the current CAN/CGA
-B149 Installation Code in Canada or to the National Fuel
Gas Code, ANSI Z223.1, and NFPA54 in the United States.
Suitableformobilehomeinstallationifinstalledinaccordance
with the current standard CAN/CSAZ240MH Series, for gas
equippedmobilehomes,inCanadaorANSIZ223.1andNFPA
54 in the United States.
-
nectedfromthegassupplypipingsystemduringanypressure
testing of that system at test pressures in excess of 1/2 psig
piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig (3.5 kPa).
the full width and depth.
The optional heat circulating blower is supplied with a cord. If
installed, the junction box must be electrically connected and
grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 CANADIAN ELEC-
TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.