NCR OPTIC 5 User manual

Installation Instructions
NCR OPTIC 5 for Encore 500s Non ECIM (6001-0011-
8801)
NCR Eng Kit Part Number: 497-0518324

The product described in this document is a licensed product of NCR Corporation.
NCR is a registered trademark of NCR Corporation. NCR RealPOS is a trademark of NCR Corporation in
the United States and/or other countries. Other product names mentioned in this publication may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks
or registered trademarks of HDMI Licensing LLC in the United States and other countries.
Where creation of derivative works, modifications or copies of this NCR copyrighted documentation is
permitted under the terms and conditions of an agreement you have with NCR, NCR's copyright notice
must be included.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components,
software, and firmware become available. NCR, therefore, reserves the right to change specifications
without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the
world. In some instances, photographs are of equipment prototypes. Therefore, before using this
document, consult with your NCR representative or NCR office for information that is applicable and
current.
To maintain the quality of our publications, we need your comments on the accuracy, clarity,
organization, and value of this book. Please use the link below to send your comments.
EMail: FD230036@ncr.com
Copyright © 2017-2018
By NCR Corporation
Atlanta, GA U.S.A.
All Rights Reserved

iii
Revision Record
Issue Date Remarks
AJan 2017 First Issue
BApril 2018 Update to revised part numbers

iv

i
Preface
Audience
This book is written for end users (System Administrator and Maintenance Technician),
NCR Field Engineering, and VAR/OEM Hardware and System Integrators
Notice:This document is NCR proprietary information and is not to be disclosed or
reproduced without consent.

ii
Safety and Compliance Information
This section introduces the hazards and safety precautions associated with installing,
inspecting, maintaining or servicing the Encore 500s Non-ECIM. Before proceeding,
check the relevant hazard and safety information. Fire, explosion or electrical shock
could occur and cause death or serious injury if these safe service procedures are not
followed.
All work must be carried out in accordance with NFPA (National Fire Protection
Association) 30, 30A, and 70, and any local authority.
Preliminary Precautions
You are working in a potentially dangerous environment of flammable fuels, vapor, and
high voltage. Only trained or authorized individuals knowledgeable in the related
procedures should install, inspect, maintain or service this equipment.
Emergency Total Electrical Shut-Off
Locate the forecourt emergency fuel shut-off valves and electrical isolation breakers.
Understand how to use these, should they be required. Locate the switch or circuit
breakers that shut-off all power to all fueling equipment and dispensing devices.
Total Electrical Shut-Off Before Access
Any procedure requiring access to electrical components or the electronics of a
pump/dispenser requires total electrical shut-off of that unit. Understand the function
and location of this switch or circuit breaker before inspecting, installing, maintaining,
or servicing the Encore 500s Non-ECIM.
Evacuation, Barricading, and Shut-Off
Any procedures requiring accessing a pump/dispenser head requires the following three
actions:
• An evacuation of all unauthorized persons and vehicles
• Using safety tape or cones as barricades to the effected units
• A total electrical shut-off of the affected unit(s)
Safety Equipment
Throughout the Disassembly and Installation procedures of the OPT Retrofit Kit
involves working with and around hazardous materials and apparatuses. Use of proper
safety equipment such as ANSI (American National Safety Institute) Personal Protective
Equipment such as safety glasses, insulated gloves, and protective footwear.

iii
Read the Manual
Read, understand and follow this manual and any other labels or related materials
supplied with the equipment. If you do not understand a procedure, call NCR. It is
imperative to your safety and the safety of others to understand the procedures before
beginning work.
Follow the Regulations
Regulations in OSHA (Occupational Safety and Health Administration), national, state
and local codes, including customer requirements must be followed. Failure to install,
inspect, maintain or service this equipment in accordance with these codes, regulations
and standards may lead to legal citations with penalties and may affect the safe use and
operation of the equipment.

iv
Safety Symbols and Terminology
Signal Words
Warning: Alerts you to a hazard or unsafe practice that could result in death or
serious injury.
Caution: Designates a hazard or unsafe practice which may result in minor injury,
property or equipment damage.
Note: To emphasize points or remind installer of something, or to indicate the
possibility of minor problems in the outcome of what installer is doing.

v
Out of Box Failure (OBF)
If you experience an out of box failure (OBF) during installation or staging related to a
missing, wrong or defective unit or item, simply provide NCR with a detailed
description of the issue and the item will be replaced free of charge. For assistance with
this process send an email to CustomerSat.Retail@ncr.com with the following details:
• NCR Sales Order # (Sales Order # are located on the box)
• Date of Product Installation
• Product Model #
• Unit Serial #
• NCR part # of defective/missing/wrong component
• Description of Failure (please be specific. For example: “display will not power on”)
• Customer/Requestor’s contact name, phone number and/or e-mail address
• Address to ship replacement part(s)
Transport the product n its original packaging to prevent impact damages.
If you do not have access to a computer, you may leave a voice message at: 1-800-528-
8658 (USA), or (International) +1-770-623-7400. When leaving a message, please provide a
phone number and/or an email address so NCR can contact you if additional details are
needed.
Note: Used equipment that experiences a failure does not qualify as an OBF and should
go through the NCR warranty process.

vi
Warranty
Warranty terms vary by region and country.
All parts of this product that are subject to normal wear and tear are not included in the
warranty. In general, damages due to the following are not covered by the warranty.
• Improper or insufficient maintenance
• Improper use or unauthorized modifications of the product.
• Inadequate location or surroundings.
For detailed warranty arrangements please consult your contract documents.

vii
Returning Defective Hardware for Service
Use the following procedure to report/return defective hardware.
Call the NCR Customer Care Center at 1-800-262-7782 and have the following information
available when you place the call.
• Class/Model number of the defective equipment
• Serial Number of the defective equipment
• Equipment location in the store
• Description of the problem, including any system error codes, error condition, or
guidance to the area of failure.
The NCR Agent will provide you with a work order number, which serves as your
Return Material Authorization (RMA). Please provide the RMA on the outside of the
shipping box.
Note: A work order must be opened for each device that is shipped for repair.

viii

ix
Table of Contents
Installation Components 1
Additional Required Kits 1
Encore Upgrade Kit Contents 1
Tools Required 3
Recommended Materials 5
Deinstallation Instructions For Encore
Before Uninstalling Begins 7
Remove Reused Exterior Door Components 7
Open the dispenser 10
Uninstall the printer 12
Uninstall the PPU 14
Remove the Magnetic Boot Switch 15
Uninstall the Comm Speaker (if present). 16
Uninstall the Totalizers (If present) 18
Remove all cable harnesses from the non modular door 20
Uninstall the Weather Shield 21
Uninstall the Non Modular Door 22
Installation Instructions for Encore
Mount the Modular Door 25
Prepare the Modular Door 30
Prepare the Nozzle Boot 30
Install the nozzle blanks and decals. 31
Install the Nozzle Boot 35
Install the PPU Bracket 36
Transfer the Magnetic Boot Switch or Switches 37
Install the OPTIC5 Modular Plate (497-0514266) 38
Transfer Components 40

x
Install the Grade Selection Assembly 43
Power Supply Assembly (497-0513438) Installation 47
Prepare the power supply brackets 47
Installing the power supply 47
Install the Comm Cable to the Dispenser Cub 50
Wiring in the Power Supply to the Pump Power Distributor
for the First (Side A)PSU 51
Wiring in the Power Supply to the Pump Power Distributor
for Second Installed (B Side) PSU 57
Install the power and data connections to the Optic 12 58
Closing the Dispenser 65

Installation Components 1
Installation Components
Additional Required Kits
Additional
Required Ret-
rofit Kit
UL Listing Information Amount required
Dispenser Cub UL Listed by Report Retrofit Kit Part Number
6009-0008-8801 (InvencoLink Converter)
One per dispenser. to be
Installed on Side A PSU
Bracket.
Encore Upgrade Kit Contents
Before starting the installation, inspect the installation kit and confirm that all parts are
accounted for as below (In order of use).

2 Installation Components
Part Number QTY Description
497-0513238 2 Replacement Modular Door
497-0513278 2 Top Hinge Pin
006-8625157 50 1/4" Hex Screw Bolt (4 spares)
497-0513806 8 Nozzle Boot Bracket
006-8625160 16 Thread Forming Screw
497-0512953 8 Lower Blanking Plug
497-0512580 6 Aluminum Blank
006-8625190 16 Phillips Screw
006-8625159 16 Machine Screw
497-0512920 8 Top Boot Aluminum Blank
497-0512581 2 Full Blanking Label
497-0512882 4 Single Blanking Label
006-8625344 8 Nozzle Boot Switch Screw
497-0514266 2 Encore OPTIC5 Retrofit Kit Modular Plate
006-8625156 16 Attaching Washer
006-8625189 10 Modular Panel Screw
497-0513438 2 PSU Assembly
006-8617730 4 PSU Nuts
497-0513385 2 Encore ACPower Adapter Cable
497-0513679 2 Encore 500/500s Comm Adapter Cable
497-0514570 2 Encore AC Adapter Y Cable
497-0513383 2 Cat-5e Data Cable(6ft, red)
497-0513384 2 Cat-5e Network Cable (6ft, yellow)
497-0517179 2 OPTIC5 Hatch Cover
497-0513215 2 Grounding Cable for OPTIC5 Hatch Cover

Tools Required 3
Tools Required
The following tools are required to mount the OPTIC 5 Door Upgrade onto a GVR
Encore fuel dispenser:
• Safety Glasses
• GCBO Key
• GVR 751 Key
• Medium Flathead Screwdriver
• #6 (or small) and medium Phillips Screwdriver
• Socket Wrench and Assorted Hex Sockets or Nut Drivers
• 1/4" and 7/16" (Could vary by pump)s
• Wire Stripper and Cutter
• Needle-Nosed Pliers
• UL Listed Crimp-on Fork Connectors/Terminals
• Small Wire/Zip-tie Clippers
Warning: Do NOT use power tools if working on a fuel station forecourt. Any spark
could cause an explosion.

4

Recommended Materials 5
Recommended Materials
The following tools are not provided in the kit:
• Cable Restraints or Zip Ties
• Cloth Rags
• All-Purpose Lubricant
• Adhesive Remover
• Rust Penetrator Oil

6
Other manuals for OPTIC 5
5
This manual suits for next models
2
Table of contents
Other NCR Touch Terminal manuals

NCR
NCR Verifone UX100 Manual

NCR
NCR 7460 User manual

NCR
NCR Ordermang 9900 Installation manual

NCR
NCR RealPOS 2x20 Manual

NCR
NCR RealPOS 80c User manual

NCR
NCR RealPOS 70 User manual

NCR
NCR P1235 User manual

NCR
NCR P1535 User manual

NCR
NCR PAX S500 User manual

NCR
NCR RealPOS 70XRT 7403 Operating instructions