4
Using the Timer
1. Set Timer switch to on (I).
2. Turn the Timer Adjustment Knob to the desired length of time you wish to jog. Choose from 0 to 60 seconds.
3. If the Power Switch is set to FOOT, air blow and vibrations begin when the foot switch is stepped on once.
Jogging and air blow will stop when the set time has passed.
4. If the Foot Switch is stepped on continuously, only the air blow will stop when the set time has passed. Then
when the Foot Switch is released jogging will also stop. Adjust depending on paper conditions.
TROUBLESHOOTING
TROUBLE POSSIBLE CAUSE REMEDY
Paper is not jogged
completely
Paper is a non-standard size Jog it while loosening it by hand.
Paper has static electricity Add some space between the sheets by
hand.
Too much paper in paper tray Reduce the volume of paper jogged at one
time.
Air blow is weak Air adjustment knob is set to
low volume
Turn knob to the right to increase air ow.
Paper or paper scrap is lodged
in air inlet or outlet
Clear air inlet and/or outlet.
If air ow problem is not xed following these suggestions, blower
maintenance may be required. Call for service.
No air is discharged Air adjustment knob is set to
OFF
Turn knob to the right to increase air ow.
Fuse 2 is blown Replace Fuse 2
If the fuse is blown again after replacement, the cause may be within the
machine. Call for service.
Paper tray will not vibrate Jogger adjustment knob is set
to OFF
Turn knob to the right to increase vibrations
Fuse 1 is blown Replace Fuse 1
If the fuse is blown again after replacement, the cause may be within the
machine. Call for service.
Clean the air outlet vents in the paper tray to remove paper scraps or dust.
Clean the air inlet lter (located on the left side of the machine) on a regular basis.
DAILY MAINTENANCE
© 2009 Neopost USA Inc. All rights reserved