CORRECTIVE ACTIONERROR CONDITION
Measured value is
wrong
Check if origin point is set properly.
Re-set.
Check if measuring surfaces are
dirty. Clean with lens cloth.
LCD displays: “ERR 0” Sensor reading error. Please re-set
origin point.
Nothing is
displayed on LCD
Display is not stable
Display is not clear
Remove and reinsert battery to
cycle power.
Replace the new battery.
Make sure the battery cover
terminals are not damaged.
Gauge head does not
retract
When stored at low temperature, or
not used for a while, the internal
grease may become stiff. Allow
sufficient time for grease to warm up.
Wearing dust-free gloves, use hand
to push in.
【POWER ON】
Press either [MODE]or [SET]button to turn on instrument --
screen will display “CAL”. Press the [SET]button again to
recall the Preset Value and display the measurement screen.
【AUTO DISPLAY OFF】
After approx. 4 hours of inactivity, the display will turn off.
Press [MODE]or [SET]button to turn it on.
【POWER OFF】
Press the [SET]button and hold for 1 sec. to turn off power.
※When inputting preset values, pressing the [SET]button for
more than one sec. does not turn off power.
※Use ring gauge appropriate for instrument measuring range.
The Origin point will be reinitialized after power off or battery
replacement. Please reset origin using ring gauge before
measurement.
1.Prepare instrument and ring gauge by cleaning
measurement head and ring gauge inner diameter with
appropriate cleaner.
2.Turn on instrument power and enter the ring gauge size as
a preset.
( Refer to -③Preset Function)
3.Insert the measurement head into the ring gauge and turn
the ratchet stop until the measuring surfaces make contact
with the inside of the ring gauge. Continue turning until
ratchet stop “clicks” 1~3 times.
4.Press the [SET]button to recall the preset value. The origin
point is now set and instrument is ready for use.
23
ORIGIN-POINT SETTING SETTINGS and MODES
TROUBLESHOOTING
POWER
A long press of [MODE]button selects the display mode. [MODE], [SET]buttons change the settings.
①
【Measurement Screen】【Measurement Screen】
【Display OFF】
②
③
※Press the [MODE]button to move
cursor, press the [SET]button change
the value.
④
⑤
【Display OFF】
●
LCD displays: “ERR 6”
Oscillation circuit error.Please
remove and reinsert battery to
cycle power.
●
LCD displays: “ERR 8” Memory error.Please remove and
reinsert battery to cycle power.
●
LCD displays: “ERR 9” Please contact distributor or place
of purchase for service.
●
●
●
●
●
●
●
●
●
●
●
Example)
Above Tolerance Limit
『 』Mark displays
Below Tolerance Limit
『 』Mark displays
POWER ON
Press either [MODE]or [SET]button to turn on power and display “CAL” on
the screen. Press [SET]button again for measurement screen.
MODE SWITCHING
From the measurement screen, press the [MODE]button and hold for more
than one second to switch to: Reference, Preset, MIN MAX, and Tolerance
screens. Release [MODE]button at desired screen to change the settings or
use that mode.
①Preset Recall Feature
When [SET]button is pressed upon power up,
or in the measurement screen, the Preset Value
set in ③below is used.
②Reference Function
Different Preset Values (origin) for REFI, REFII,
and REFIII can be selected using the [MODE]
button. This feature is useful when multiple
measurement criteria are required. While in this
mode, the [SET]button will function to HOLD
the display.
③Preset Function
The Preset Value is displayed in measurement
mode by pressing the [SET]button. Use the
[MODE] button to move the underscore cursor,
and the [SET]button to change the value. When
complete, a long press on the [MODE]button
will fix the value and return to the measurement
screen.
④MIN MAX Mode
This screen displays the Minimum Reading,
Maximum Reading, and Maximum Displacement
during measurement.
A short press of the [MODE]button switches
from “MIN” (minimum reading,) “MAX”
(maximum reading,) and “MIN MAX” (maximum
displacement) on the display and their
corresponding value.
Press the [SET]button to reset the stored
values.
⑤Tolerance Mode
Allows easy verification that a measurement is
within preset tolerance range.
With the measurement range set to
20.005mm ~ 20.000mm
1
2
SETTINGS IN EACH MODE
3
3
SETTINGS and MODES
“Click, Click”