manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Niigata seiki
  6. •
  7. Measuring Instrument
  8. •
  9. Niigata seiki GVC KDE Series User manual

Niigata seiki GVC KDE Series User manual

   
 PP

        

  PP
Object to be measured is positioned between these surfaces.
Measures external dimensions. Move Slide to open and close.
Measures the height of steps.
Measures internal dimensions. Move Slide to open and close.
Position surfaces inside object to be measured.
Locks the Vernier Slide position.
Indicates measured value in 1mm graduations.
Bar for measuring depth. Bar moves in and out with Vernier Slide.
Depth is measured between these two surfaces.
Position thumb on knob for precise control of vernier slide.
Scale for measuring with a resolution of 0.05mm.
Refer to following page for usage instructions.
①Measuring Surfaces for outside measurements …②Outside Jaws …………………………………………③Measuring surfaces for step measurements………④Inside Jaws……………………………………………⑤Measuring surfaces for internal measurements …⑥Lock Screw……………………………………………⑦Main Scale ……………………………………………⑧Depth Bar ……………………………………………⑨Measuring surfaces for depth measurements ……⑩Thumb Knob …………………………………………⑪Vernier Slide (Vernier Scale)………………………Thank you for purchasing the Vernier Calipers (Kaidan Scale).
This product is a precision measurement tool with a main scale and a vernier scale to indicate the measured value.
●For safe and proper use of this product, please read this instruction manual before use and follow the procedures described.
 Please keep manual where it is accessible to user for future reference.
●Keep this manual with the instrument if transferred or leased to a third party.
●For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.
■PART IDENTIFICATION AND FUNCTION
SAFETY PRECAUTIONS Please Observe
Always follow the proper operating procedures in order to prevent
harm to yourself or others, and to prevent damage to property.
Read the manual and follow the instructions.
・Use of product other than as described in the manual
may cause accident.
Use only for measuring.
・Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
・Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
・Do not scratch instrument, for example by writing ID
number.
Indicates risk of personal injury or property damage if not followed.
WARNING
Use In Proper Environment
・Please do not use instrument in rain or locations with
excessive humidity. Do not use at extreme high or low
temperatures. Keep out of direct sunlight.
Jaw Tips Are Sharp – Handle With Care.
・Careless handling may cause injury.
Do not move the Vernier Slide when the Lock Screw
is tightened.
・Excessive force applied to Slide may cause damage or
affect accuracy.
Do not disassemble or modify.
・Do not remove the vernier slide, Please do not attempt
to disassemble or modify as it may cause damage or
poor accuracy.
①Measuring surfaces for
 outside measurements
②Outside Jaws
③
Measuring
 
surfaces for step
 
measurements
⑤Measuring surfaces for internal measurements
⑥Lock Screw
⑩Thumb Knob
⑪Vernier Slide (Vernier Scale)
⑦Main Scale ⑧Depth Bar
⑨Measuring surfaces for
 depth measurements
④Inside Jaws
VERNIER CALIPERS (Kaidan Scale)
PRECISION MEASURING TOOLS
GVC-**KDE
Model No.
User Manual
Denotes a prohibition -
You MUST NOT do
Denotes a requirement -
You MUST do
CALIBRATION
●In order to maintain instrument accuracy, it is recommended that
accuracy is confirmed through calibration on a periodic basis.
Wear of measuring surfaces from repeated use may affect accuracy and periodic
accuracy checks should be performed.
We provide calibration services.
Please contact agent in country of
purchase to make arrangements.
※Model GVC-15KDE shown.
 

        

 PP
 

        

 PP
 

        

 PP
 


        

 PP
PREPARATION FOR USE
Before using the caliper, follow the steps below:
●Loosen the lock screw.
Moving the vernier slide with the lock screw tightened may cause excessive force to the slide which will damage the caliper and affect
accuracy.
●Wipe off any dirt, or oil from measuring surfaces and slide.
Contamination of surfaces may cause measurement error.
●Allow the caliper and object to be measured time to reach the same temperature.
A temperature difference between the object to be measured and the caliper may cause measurement error. Allow enough time for the
temperatures to equilibrate.
●Performing an accuracy check.
①Jaw Alignment
 In closed position, make sure the measuring surfaces on the outside jaws
align properly and there is no gap (no light should leak past.)
②Confirm “0”points on scale (see diagram at right)
 With jaws closed as in step ①above, make sure the reading is zero and
the vernier scale graduations align at the “0”and “39”positions as shown.
③Depth Confirmation
Position caliper on a flat surface for depth measurement. Reading should
be “0”as in step ②above, with the verier graduations aligned at the “0”
and “39”positions.
READING THE SCALE
The measured value is determined by reading the main scale,
and then adding the Vernier Scale reading as determined by
the position where the vernier and main scale graduations align.
PREVENTING ERRORS
In order to prevent measurement error, please note the following.
AFTER USE CARE, STORAGE NOTES
●Material : Stainless Steel
GVC-15KDE
150mm
140g
GVC-20KDE
200mm
0.05mm
200g
GVC-30KDE
300mm
380g
±0.05mm ±0.08mm
SPECIFICATIONS
●Wipe slide, measuring surfaces, and exterior with a dry
cloth treated with anti-corrosive oil. When not in use,
apply anti-corrosive treatment or keep in anti-corrosive
bag.
●When not in use, keep jaws slightly open and lock
screw slightly loose to prevent over tightening due to
thermal expansion which may affect accuracy.
●Store in supplied case in a cool, dry location. Keep
away from direct sunlight or wet locations and protect
from use by unauthorized personnel.
●EXAMPLE 1
Measured value = Main Scale Reading + Vernier Scale Reading
77
0.00+77.00
Reading
77
0.30+77.30
Reading
77
0.35+77.35
Reading
Measured Value: 77.00mm
●EXAMPLE 2 Measured Value: 77.30mm
●EXAMPLE 3 Measured Value: 77.35mm
POSITIONING CALIPER ON OBJECT
Scale should be read from
directly above the calipers.
Due to step in height of vernier
scale relative to main scale, if
viewing direction is not directly
above the reading may have
parallax error.
<Flat surfaces>When measuring features
with flat surfaces, make sure
the measuring surface of the
jaws are parallel to the
surfaces to be measured.
<Cylindrical surfaces>When measuring cylindrical
features, make sure the caliper
jaws are perpendicular to the
cylinder axis as shown.
VIEWING THE SCALE
Proper alignment
Workpiece
Jaw
Main Scale
(1㎜)
Vernier Scale
(0.05㎜)Main Scale
(1㎜)
Vernier Scale
(0.05㎜)Main Scale
(1㎜)
Vernier Scale
(0.05㎜)I442-K 2205
Model No.
Measuring Range
Resolution
Maximum
permissible error
Weight

This manual suits for next models

3

Other Niigata seiki Measuring Instrument manuals

Niigata seiki EOM133 Series User manual

Niigata seiki

Niigata seiki EOM133 Series User manual

Niigata seiki DI-1058 User manual

Niigata seiki

Niigata seiki DI-1058 User manual

Niigata seiki D IP67S Series User manual

Niigata seiki

Niigata seiki D IP67S Series User manual

Niigata seiki GDCS-150ST User manual

Niigata seiki

Niigata seiki GDCS-150ST User manual

Niigata seiki GDCS-150F User manual

Niigata seiki

Niigata seiki GDCS-150F User manual

Niigata seiki TVC-15S User manual

Niigata seiki

Niigata seiki TVC-15S User manual

Niigata seiki WDI-10KD User manual

Niigata seiki

Niigata seiki WDI-10KD User manual

Niigata seiki MCD3385-0608HTN User manual

Niigata seiki

Niigata seiki MCD3385-0608HTN User manual

Niigata seiki WCDI-6D User manual

Niigata seiki

Niigata seiki WCDI-6D User manual

Niigata seiki EOM133 Series User manual

Niigata seiki

Niigata seiki EOM133 Series User manual

Niigata seiki QEM394 Series User manual

Niigata seiki

Niigata seiki QEM394 Series User manual

Niigata seiki VH-30D User manual

Niigata seiki

Niigata seiki VH-30D User manual

Niigata seiki CJU BKD Series User manual

Niigata seiki

Niigata seiki CJU BKD Series User manual

Niigata seiki WCDI-6 User manual

Niigata seiki

Niigata seiki WCDI-6 User manual

Niigata seiki DUP-360AN User manual

Niigata seiki

Niigata seiki DUP-360AN User manual

Niigata seiki DHG-35M User manual

Niigata seiki

Niigata seiki DHG-35M User manual

Niigata seiki LEVELNIC DL-S3 DL-BW User manual

Niigata seiki

Niigata seiki LEVELNIC DL-S3 DL-BW User manual

Niigata seiki DT Series User manual

Niigata seiki

Niigata seiki DT Series User manual

Niigata seiki LEVELNIC DL-S3L User manual

Niigata seiki

Niigata seiki LEVELNIC DL-S3L User manual

Niigata seiki GDCS-150NP User manual

Niigata seiki

Niigata seiki GDCS-150NP User manual

Niigata seiki TVC-15S User manual

Niigata seiki

Niigata seiki TVC-15S User manual

Niigata seiki DHG-35M User manual

Niigata seiki

Niigata seiki DHG-35M User manual

Niigata seiki S Series User manual

Niigata seiki

Niigata seiki S Series User manual

Niigata seiki LEVELNIC User manual

Niigata seiki

Niigata seiki LEVELNIC User manual

Popular Measuring Instrument manuals by other brands

Agilent Technologies DSOX4USBSQ USB 2.0 Electrical testing notes

Agilent Technologies

Agilent Technologies DSOX4USBSQ USB 2.0 Electrical testing notes

Brunton MM10602 user guide

Brunton

Brunton MM10602 user guide

Elcometer 205 operating instructions

Elcometer

Elcometer 205 operating instructions

Shot-Scope PRO LX user guide

Shot-Scope

Shot-Scope PRO LX user guide

Geotech ETL WLM+T Installation and operation manual

Geotech

Geotech ETL WLM+T Installation and operation manual

Bristol 621 user manual

Bristol

Bristol 621 user manual

Siko IK360L Translation of the original installation instructions

Siko

Siko IK360L Translation of the original installation instructions

Endress+Hauser Levelflex M FMP40 technical information

Endress+Hauser

Endress+Hauser Levelflex M FMP40 technical information

Koso BB642W20 instructions

Koso

Koso BB642W20 instructions

Nikon NPL-632 instruction manual

Nikon

Nikon NPL-632 instruction manual

Interacoustics AD629 Instructions for use

Interacoustics

Interacoustics AD629 Instructions for use

SENSIT Technologies ULTRA-TRAC APL quick start guide

SENSIT Technologies

SENSIT Technologies ULTRA-TRAC APL quick start guide

Vision & Control TOB42/11.0-145-V-WN Instructions for use

Vision & Control

Vision & Control TOB42/11.0-145-V-WN Instructions for use

Sealey TA304 instructions

Sealey

Sealey TA304 instructions

YOKOGAWA 73201 user manual

YOKOGAWA

YOKOGAWA 73201 user manual

Kentix AlarmManager-BASIC user manual

Kentix

Kentix AlarmManager-BASIC user manual

Rohde & Schwarz RT-ZP03 user manual

Rohde & Schwarz

Rohde & Schwarz RT-ZP03 user manual

ION F-SP 12 quick start guide

ION

ION F-SP 12 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.