Nikon Callaway ID Tech User manual

NIKON VISION CO., LTD.
Customer Service Department
3-25, Futaba 1-chome, Shinagawa-ku, Tokyo 142-0043, Japan
Tel: +81-3-3788-7699 Fax: +81-3-3788-7698
Printed in China (197K)/1E
CAUTIONS BEFORE USE
Please observe the following guidelines strictly so you can use the equipment properly
and avoid potentially hazardous problems. Before using this product, read thoroughly the
“SAFETY AND OPERATION PRECAUTIONS” and instructions on correct usage
accompanying the product. Keep this manual within reach for easy reference.
WARNING
This indication alerts you to the fact that any improper use ignoring the contents
described herein can result in potential death or serious injury.
CAUTION
This indication alerts you to the fact that any improper use ignoring the contents
described herein can result in potential injury or material loss.
SAFETY AND OPERATION PRECAUTIONS
Warning
•
Never look directly at the laser beam or directly at the sun when using the Nikon
Callaway id TECH.
• DonotdepressthePOWERbuttonwhilelookingintotheopticsfromtheobjectiveside.
• Donotaimattheeye.
• Donotoperatetheunitwithotheradditionalopticalelements,suchaslensesor
binoculars. Using an optical instrument together with the Nikon Callaway id TECH
increases the danger of damaging the eyes.
• DonotdisassembletheNikonCallawayidTECH.Aproductthathasbeendisassembled
is not guaranteed by the manufacturer.
•
WhentheNikonCallawayidTECH’sbodycoverisdamaged,orifitemitsastrange
sound due to dropping or for some other cause, immediately remove the
battery and stop using.
Cautions
• WhennotusingtheNikonCallawayidTECH,donotpushthePOWERbutton.
• DonotleavetheNikonCallawayidTECHwithinthereachofsmallchildren.
• Rain,water,sandandmudshouldberemovedfromtherangefinderbodysurfaceassoon
as possible, using a soft, clean, dry cloth.
• AlthoughtheNikonCallawayidTECHiswaterproof,itisnotdesignedforuse
underwater.
• DonotswingtheNikonCallawayidTECHbyitsstrap.Itmayhitsomeoneandcause
injury.
• DonotleavetheNikonCallawayidTECHinanunstableplace,asitmayfallandcause
injury, or damage the equipment.
• DonotlookthroughtheNikonCallawayidTECHwhilewalking.Youmaywalkinto
something and get hurt.
• DonotleavetheNikonCallawayidTECHinacaronahotorsunnyday,ornearheat-
generating equipment. This may damage or negatively affect it.
• DonotleavetheNikonCallawayidTECHindirectsunlight.Ultravioletraysand
excessive heat may negatively affect or even damage the unit.
• WhentheNikonCallawayidTECHisexposedtosuddenchangesintemperature,water
condensation may occur on lens surfaces. Do not use the product until the condensation
has evaporated.
• Donotusealcoholforcleaningthemainbody.
• Donotleavethepolyethylenebagusedforpackagingwithinthereachofsmallchildren.
• Becarefulthatsmallchildrendonotinadvertentlyswallowtheeyecup.Ifitdoeshappen,
consult a doctor immediately.
• Ifyouusetherubbereyecupforalongperiodoftime,youmaysufferskininflammation.
If you develop any symptoms, consult a doctor immediately.
• WhencarryingtheNikonCallawayidTECH,storeitinthesoftcase.
• IfyourNikonCallawayidTECHshouldfailtooperatecorrectly,discontinueuse
immediately and consult the Troubleshooting Table. If you are unable to fix the problem,
contact your local dealer for instructions on where to send it for repair.
CARE AND MAINTENANCE
Lenses
• Whenremovingdustonthelenssurface,useasoftoil-freebrush.
• Whenremovingstainsorsmudgeslikefingerprintsfromthelenssurface,wipethelenses
very gently with a soft clean cotton cloth or quality oil-free lens tissue.
Use a small quantity of pure alcohol (not denatured) to wipe stubborn smudges. Do not
use velvet cloth or ordinary tissue, as it may scratch the lens surface. Once the cloth has
been used for cleaning the body, it should not be used again for the lens surface.
Main body
• Cleanthebodysurfacewithasoft,cleanclothandadrycloth.Donotusebenzene,
thinner, or other organic agents because they may cause discolouration or rubber
degeneration.
Storage
• Watercondensationormouldmayoccuronthelenssurfacebecauseofhighhumidity.
Therefore, store the Nikon Callaway id TECH in a cool, dry place.
After use on a rainy day or at night, thoroughly dry it at room temperature, then store in a
cool, dry place.
NOTES ON LITHIUM BATTERY
If handled incorrectly, batteries may rupture and leak, corroding equipment and staining
clothing. Be sure to observe the following:
• Installbatterieswiththe+and–polespositionedcorrectly.
• Batteriesshouldberemovedwhenexhaustedorduringextendedperiodsofnon-use.
• Alwaysusethesamebrandofbattery.
• Ifbatteryfluidcontactseyesorskin,rinsewellwithwater.Ifswallowed,consultadoctor
immediately.
• Donotshort-circuitbatterychamberterminals.
• Donotcarrybatteriestogetherwithkeysorcoinsinapocketorbag.Thismayoverheat
and short-circuit batteries.
• Donotputbatteriesinfireorwater.Neverdisassemblebatteries.
• Donotchargebatteries.
• Donotsubjectstoredbatteriestoextremesintemperature.
• Donotsubjectbatteriestostrongvibrationsorshock.
Key Features
Body .............................................x1
Soft case ......................................x1
Neckstrap .....................................x1
Lithium battery (CR2) ....................x1
Composition
• Lineardistancemeasurementrange:10-500meters/11-550yards/33-999feet
• Anglemeasurementrange:±89°
• Distancemeasurementdisplaystep:
[Internal Display]:
(Linear Distance)
0.5 meter/yard, 1 foot
(measurement distance is less than 100 meters/yards/feet)
1.0 meter/yard, 1 foot
(measurement distance is 100 meters/yards/feet or farther)
(Horizontal Distance/Height)
0.2 meter/yard, 0.5 foot
(measurement distance is less than 100 meters/yards/feet)
1.0 meter/yard, 1 foot
(measurement distance is 100 meters/yards/feet or farther)
(Angle)
0.1°(-10°ー10°)
1.0°( ≦-10°,10° ≦)
[External Display]:
(Linear distance) 0.5 meter/yard, 1 foot
(Horizontal Distance/Height) 0.2 meter/yard, 0.5 foot
(Angle) 0.1°
• Easy-to-aim6xopticalobservationsystem
• Quantifiesthehorizontaldistancetothetargetanditsheightinrelationtothe
rangefinder's level by measuring linear distance and angle.
• Measuretheverticalseparation(heightbetweentwopoints).
• TheresultsaredisplayedonbothaninternalandanexternalLCDpanel.The
external LCD panel shows all results simultaneously.
• MeasureanddisplayinFirstTargetPriority.
• Waterproofdesign(NOTdesignedforunderwaterusage)
• Invisible/EyesafeIECClass1MLaser
• 30-secondresultsdisplay
• Compact,lightweight,ergonomicdesign
• Automaticshut-off(afterapprox.30sec.unattended)
• Defaultto“LastUse”settings
• 20-secondcontinuousmeasuringfunction
The Nikon Callaway id TECH emits invisible, eyesafe, infrared energy pulses
that reflect off the selected target back to its optical receiver. Sophisticated
precision charge circuitry is used to instantaneously calculate distances, by
measuring the time it takes for each pulse to travel from the rangefinder to the
target and back. Laser reflectivity and measurement results may vary according
to climatic and environmental conditions, the colour, surface finish, size, shape
and other characteristics of the target.
The following factors ensure best range and accuracy:
• Nighttimeuse
• Cloudyweather
• Bright-colouredtargets
• Targetswithhighlyreflectivesurfaces
• Targetswithshinyexteriors
• Large-sizetargets
• Shootingtargetsfacingat90degrees
Measurement may result in inaccuracy or failure in the following cases:
• Slenderorsmalltarget
• Targethasdiffusingreflectivesurface
• Targetdoesnotreflectthelaserbeam(glass,amirror,etc.)
• Blacktarget
• Targethasvaringdepths
• Insnow,rainorfog
• Targetmeasuredthroughglass
• Reflectivesurfacemeasuredfromdiagonaldirection
• Movingtarget
• Obstaclemovinginfrontofthetarget
• Whentargetingthesurfaceofwater
Nomenclature
1
Monocularobjectivelens/
Laser emission aperture
2
Laser detector aperture
3
External LCD
4
MODEbutton
5
POWERbutton
6
6x monocular eyepiece
7
Eyecup/diopter adjustment ring
8
Diopter index
9
Strap eyelet
!p
Battery chamber cover
!q
Battery chamber cover “Open/
Close” indication
!w
Product number/explanatory label
!e
Laser warning label
Internal Display
1. 『 』- Targetfocusing/Laser irradiate system
『』-Aim at the target. Position the target
at the center of the reticle.
『 』- Appears while the laser is being used
for a measurement. (Remains present during
single measurement.Blinks during continuous
measurements.)
Warning: Do not look into the objective lenses
when this mark is shown.
2.『』: Distance/measurement status display
Digitally indicates measured distance in meters/yards/feet and angles in
degrees. Also indicates measuring status such as “Measurement in
progress”, “Measurement unsuccessful” or “Unable to measure.”
<Examples of measurement results>
(Distance)
Display of results: ( ≧100m/yards/feet) e.g. 234 meters =『』
Display of results: ( <100m/yards) e.g. 76.5 yards =『』
Display of results: ( <100 feet) e.g. 82 feet =『』
(Angle)
Display of results: ( ≦-10˚ and ≧10˚) e.g. 36˚=『』
e.g. -29˚=『』
Display of results: (-10˚<and <10˚) e.g. 3.5˚=『』
e.g. -7.0˚=『』
『』- Now measuring
『』- Failure to measure or unable to measure distance
3. 『』Display Units
『』Indicates distance being measured in meters.
『』Indicates distance being measured in yards.
[No unit displayed] Indicates distance is measured in feet.
4. 『』- Indicates battery condition. (See "Changing Batteries")
5. 『』Display Modes
(See “Measurement and Display” for operations and display examples.)
Linear distance mode
『 』Calculates linear distance to your target and displays the results.
Horizontal distance mode
『 』 Calculates horizontal distance to your target by measuring
the linear distance and angle, and displays the results.
Height mode
『 』 Measures your target's height from the horizontal level, and
displays the results.
Vertical separation (height between two points) mode
『 』 Uses the linear distance and angle data of two points to
calculate and display the vertical separation (height
between the two points.)
Angle mode
『』 Measures the angle of your target from the horizontal level
and displays the results.
Although the LCD was produced using the most advanced technology, it is
impossible to eliminate dust completely.When using this product, the LCD is
magnified by high magnification of the eyepiece lens and dust may appear as
a defect. It will not, however, affect measurement accuracy.
Operational Summary
Caution—use of controls or adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure
1. Install a battery in the battery chamber. (See Changing
Batteries)
2. Rubber eyepiece cup
Eyeglass wearer: Collapse the eyepiece cups.
Non-eyeglass wearer: Do not collapse the eyepiece cups.
3. Diopter adjustment
Adjust diopter to obtain a clear image in the LCD.
First, rotate the diopter adjustment ring counterclockwise until it comes to a
complete stop. Next, turn on the power to activate the LCD when you look
through the Nikon Callaway id TECH. Rotate the diopter adjustment ring
clockwise until the display comes into focus.
If the diopter is not adjusted to correspond to your eyesight, you may not be
able to clearly focus your subject.
4. Measuring
Note: See separate “Measurement and Display” sheet for external LCD panel.
Note: Depressing and holding down the POWER button causes all symbols to be
displayed in the internal LCD panel. After you remove your finger from the
POWER button, the last-used setting is displayed. (If you briefly press the
POWER button then remove your finger, the LCD panel may display the last-
used setting without displaying all of the symbols. This is not a malfunction
or other problem.)
Before measuring, be sure to confirm settings, such as unit, measurement/display
mode and priority mode.
◎: See the relevant mode section in this manual for setting.
Changing Batteries
Type of battery: 3V CR2 lithium battery
Battery condition indicators
: Battery has enough charge for use.
: Battery charge is getting low.
flashing: Battery charge is low and battery
should be replaced.
disappears: Battery is exhausted and should
be replaced.
flashing in the LCD indicates that the battery should be replaced.
1Open the battery chamber cover
Using the ball of the thumb or a coin in the recessed part of the battery
chamber cover, rotate the cover following the Open/Close arrow indicator. It
may not open easily due to its rubber packing for water resistance.
2Replace the old battery with a new one
Install new battery with the [+] and [-] correctly positioned following the
“Battery installation” indication seal in the battery chamber. (Insert battery
positioning the [+] pole towards the inside of the chamber.) [The Nikon
Callaway id TECH will not operate if the battery is installed incorrectly.]
3Close the battery chamber cover
Align the Open/Close indicator with the white dot and insert the battery
chamber cover. Using the ball of the thumb or a coin, turn the cover in the
opposite direction to the arrow indicator. It may not close easily due to the
rubber packing for water resistance, but continue to turn it all the way until
it stops. Confirm that the cover is securely closed.
Battery life
Continuous operation:
Approx. 10,000 times (at 20°C)
Target focusing, measurement, and automatic power off are included in a
single cycle.This figure may differ according to temperature, and other
factors such as target shape, colour, etc.
* The Nikon Callaway id TECH come with a 3V CR2 lithium battery. However, due to
natural electric discharge, the life of the battery will likely be shorter than that noted
above.
Replace battery if the Nikon Callaway id TECH is ever submerged in water or if water
enters in the battery chamber.
Specifications
Laser Rangefinder
Thank you for purchasing the Nikon Callaway id TECH.
This high-spec laser rangefinder features a new angle measurement function in
addition to the existing linear distance measurement function for enhanced
enjoyment of sports and other outdoor applications. (The Nikon Callaway id
TECH is also able to measure the horizontal distance to a target and its height.)
Please observe the following guidelines strictly so you can use the equipment
properly and avoid potentially hazardous problems. Before using this product,
read thoroughly the “SAFETY PRECAUTIONS” and instructions on correct usage
accompanying the product.
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
Keep this manual within reach for easy reference.
•Specificationsanddesignaresubjecttochangewithoutnotice.
•Noreproductioninanyformofthismanual,inwholeorinpart(exceptforbrief
quotation in critical articles or reviews), may be made without written
authorization from NIKON VISION CO., LTD.
Instruction Manual
Callaway id TECH
POWER
Set FULL/Limited
measurement mode
LCD is illuminated
Set your desired modes
◎
Align the reticle
with the target
POWER
appears
Results are converted to the
mode set and displayed.
MODE
Indication
remains
illuminated for
30 sec.
30 seconds pass without operation *
Power off: LCD indications disappear
Measure again
Fail to measure
Cannot measure
Successfully
measured
For continuous distance
and angle measurement
(up to 20 seconds), keep
button depressed.
※
or
☆
☆【Continuous measurement mode】
Keeping the POWER button depressed allows you to perform
continuous measurement for 20 seconds.
Blinks while performing measurements.
When measuring a pin at a golf course, for example, use Continuous
measurement mode for easy measurement. With no objects between you
and the pin, the smallest number is the distance to your targeted pin.
※See the “Measurement and Display” sheet for details regarding the
operations and results display of the various modes.“
*Power turns off 30 seconds after the last operation.
5. Selecting display unit (Factory default setting is yard.)
Meter [ ] Yard [ ] Feet [ ]
1. Confirm the LCD panel is on.
2. Press and hold the button for approx. two seconds.
3. When display unit has switched, release the button.
4. Repeat steps 2 and 3 until your desired mode is displayed.
5. When you have completed setting, results will be converted and displayed
in the your selected measurement unit.
6. Switching measurement/display modes (Factory default setting is
linear distance measurement mode)
Linear Distance [ ] Horizontal Distance [ ]
Angle [ ]
Height [ ]
Vertical Separation
between 2 points point
[ ]
By pressing the MODE button, modes will change in
the order indicated above.
The angles and heights of two points are displayed
only at the full-mode setting.
1. Confirm the LCD panel is on.
2. Press button within 0.5 seconds.
3. Release button to switch the mode.
4. Repeat steps 2 and 3 until your desire mode is displayed.
5. Switching the mode after measurement converts the results to the new
mode.
6. After the mode is set, measurements are performed in the new mode.
7. Switching Full/Limited modes (default setting is limited mode)
1. Confirm the power is off (LCD is off).
2. Press and hold button, then depress and hold button
within 0.5 second.
3. Continue to press and hold both buttons, (more than 2 seconds),to
confirm the internal display is on.
When these buttons are pressed, all symbols are displayed . When
『』and『 』symbols do not appear, Limited mode is
switched to Full mode.
Note) If buttons are not pressed in the correct order, switching will
not take place.
Note) This mode change can also be confirmed when switching the
measurement/display mode.
4. Release buttons.
8. Distance display
Nikon Callaway id TECH is First Target Priority Distance Display System.
When obtaining different results from a single measuring operation. The Nikon
Callaway id TECH will display the distance to the nearest target on the LCD
panel.
ex.) When measuring a tree standing in front of a house;
"115m" (distance to the tree) will be displayed. This mode has application for
golf.
9. Low battery indication
Flashing indicates that the battery charge is low and battery should
be replaced. (See "Changing Battery")
Optical system
Type Roof-prism monocular
Magnification 6x
Effective diameter of objective lens (mm) ø21mm
Angularfieldofview(real) 6.0°
Eye relief (mm) 18mm
Exit pupil (mm) ø3.5mm
Dioptreadjustment ±4m-1
Others
Operatingtemperature -10°—+50°
Power source CR2 lithium battery x 1, 3V DC,
Auto Power Off (approx. 30 seconds)
Dimensions(DxWxH) 130x45x69mm
Weight Approx.210g(withoutbattery)
Structure Body:Waterproof(maximumdepthof1meter
for up to 10 minutes)*
(Batterychamber:Waterresistant**)
Safety&EMC Class1MLaserproduct(IEC68025-
1:2001)
FCC Part15 subpart B Class B
CE,EMCdirective,c-tick,WEEE
* Waterproof models
The Nikon Callaway id TECH is waterproof, and will suffer no damage to the
optical system if submerged or dropped in water to a maximum depth of 1 meter
for up to 10 minutes.
The Nikon Callaway id TECH offers the following advantages:
• Canbeusedinconditionsofhighhumidity,dustandrainwithoutriskof
damage.
• Nitrogen-filleddesignmakesitresistanttocondensationandmold.
Observe the following when using the Nikon Callaway id TECH.
• Astheunitdoesnothaveaperfectlysealedstructure,itshouldnotbe
operated nor held in running water.
• Anymoistureshouldbewipedoffbeforeadjustingmovableparts(eyepiece,
etc.) of the Nikon Callaway id TECH to prevent damage and for safety reasons.
To keep your Nikon Callaway id TECH in excellent condition, Nikon Vision
recommends regular servicing by an authorized dealer.
** The battery chamber is water resistant, not waterproof. Water may enter the
device if the Nikon Callaway id TECH is submerged in water. If water enters
the battery chamber, wipe out any moisture and allow time for the chamber to
dry.
Troubleshooting/Repair
If problems persist after consulting the Troubleshooting Table,
please contact your local dealer to check/repair the Nikon
Callaway id TECH. Never let anyone than the official
representative of the product manufacturer check or repair the
Nikon Callaway id TECH. Failure to follow this instruction could
result in injury, or damage to the product.
Symptom Check Points
Unit does not turn on —
LCD fails to illuminate
Target range cannot be
obtained
[- - -] (“Cannot
measure”) appears
Closer target cannot be
measured
Target beyond a certain
distance cannot be
measured
Measurement result is
unstable
Incorrect result is
displayed
•DepressPOWERbutton.
•Checkandreplacebatteriesifnecessary.
•Besurethatnothing,suchasyourhandorfinger,is
blocking the laser emission aperture and laser
detector.
•Besurethatthelaseremissionapertureandlaser
detector are clean. Clean them if necessary.
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Replacebattery.
•Besuretoholdtheunitsteadywhiledepressingthe
POWER button.
•Besurethetargetiswithinmeasuringrange(10-
500m/11 - 550 yards/33-999 feet)
•Besurethatnothing,suchasleavesorgrass,is
between the Nikon Callaway id TECH and the target.
•Besurethatnothing,suchasleavesorgrass,is
between the Nikon Callaway id TECH and the target.
•Replacebattery.
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Besuretoholdtheunitsteadywhiledepressingthe
POWER button.
•Besurethatnothing,suchasleavesorgrass,is
between the Nikon Callaway id TECH and the target.
•Replacebattery.
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Besurethatnothing,suchasleavesorgrass,is
between the Nikon Callaway id TECH and the target.
If your Nikon Callaway id TECH should require repair, please contact your local
dealer for details regarding where to send it. Before doing so, you are advised to
consult the Troubleshooting Table below.
Do not use the Nikon Callaway id TECH for purposes beyond the limits of its
stated accuracy.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules and to EU EMC
directive. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheequipmentandreceiver.
•Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two condition0s:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
E
Tree Fence House
Distance to Target 115m 123m 128m
MeasurementSystem
Measurementmode Linear distance : Act
display Horizontal distance : Hor
Height : Hgt
Angle : Ang
Vertical separation (height between two points ): Hgt + Hgt2
Measureddistance/ Distance: 10-500meters/11-550yards/33-999feet
angle range (999 feet: 304.5 meters/333 yards)
Angle:
±89°
Distance- Act 0.5 meter/yard, 1.0 foot ( <100 meters/yards/feet)
Angle
(Linear distance)
1.0 meter/yard, 1.0 foot ( ≧100 meters/yards/feet)
Display Hor 0.2 meter/yard, 0.5 foot
(<100 meters/yards/feet)
Steps
(Horizontal dist.)
1.0 meter/yard, 1.0 foot ( ≧100 meters/yards/feet)
Hgt 0.2 meter/yard, 0.5 foot ( <100 meters/yards/feet)
(Height)
1.0 meter/yard, 1.0 foot ( ≧100 meters/yards/feet)
Ang
(Angle)
0.1°( <10°),1.0°( ≧10 °)
Linear distance
0.5 meter/yard, 1.0 foot
Horizontal dist.
0.2 meter/yard, 0.5 foot
Height 0.2 meter/yard, 0.5 foot
Angle 0.1°
System First Target Priority Distance Display system
Internal External
Laser
Class IECClass1M
Wavelength 870nm
Pulse duration 14 ns
Output 15W
Beam divergence Vertical:5°—8°,Horizontal:25°—36°
Operating humidity 80% RH (without dew condensation)
Laser Rangefinder
8
6
1
3
7
4
2
!e
!w
!q
9
!p
5

Nikon Callaway id TECH / Measurement and Display
External display and contents
After the power is turned on, the internal
and external LEDs are illuminated until
either the POWER or MODE button is
pressed.
If 30 seconds pass without operation, the
power turns off. Approx. one second
before power turns off, this screen is
displayed.
After measurement, all data “linear
distance, horizontal distance, height and
angle” are displayed. Units can be shown
in meters, yards or feet. Angles are
indicated by °(degree).
[ m ] : meter
[ YD ] : yards
[ f t ] : feet
Linear distance Horizontal distance
Height Angle Unit
[While measuring]
When the target is upward When the target is downward
[Measurement unsuccessful or unable to measure]
When the target is upward When the target is downward
With negative values,
the “– (minus)” symbol is not shown.
[Measurement complete]
[Power On]
[Power off notice]
[Results]
1 Point Measurement
When the target is upward When the target is downward
After measuring two points, "Linear
distance to two points"and "Vertical
separation (height) and angle between
two points"are displayed. Units can be
shown in meters, yards or feet. Angles
are indicated by (degree).
Linear distance (1st point)
Linear distance (2nd point)
Vertical separation (height between two points.)
Angle of two points
Unit
Measure the distance between two points
[Measuring 1st point]
(Angle measurements never fail.)
[Results of 1st point]
[Measuring 2nd point]
(Although the point is located
downward, display shows the
upward position.)
(Angle measurements never fail.)
[Display of results for two points]
[Results]
[Failed to measure 1st point]
[Failure to measure 2nd point]
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
Operation/Results Work Button Display Display examples
0 Switch for FULL/Limited Perform this operation MODE
modes when power is off. +(follow by) POWER
Operation is complete (1) Initial screen
When switching to Limited mode
When the symbol (shown on right) does not appear,
Limited mode is switched to Full mode.
After approx. two seconds, proceed to (2).
(2) Measurement standby Last use symbol
1 Power On Initial screen POWER All symbols (while pressing)
Measurement standby When this symbol (shown on right)
does not appear, Limited mode is set.
Measurement standby Last Use mode symbol
2 Selecting and setting (1) Linear distance【3】n/a
Limited mode (2) Horizontal distance
【4】
MODE n/a
(3) Height (from horizontal)【5】MODE n/a
(4) Angle (from horizontal)【6】MODE n/a
(5) Vertical separation (height between two points)【7】
MODE blinks. n/a
Return to 2-(1) Linear distance, then repeat. n/a
The angles and heights
between two points are
displayed only at the FULL
mode setting.
Linear distance, Horizontal
distance and height are
displayed when FULL/Limited
mode is set.
Initial screen (FULL mode)
Operation/Results Work Button Display
Display examples
meter yards feet
Elevation(°) Depression(°)
4 Measurement with horizontal distance mode
4-1 Seeking your target Horizontal distance
(Align the reticle with target.)
4-2 Measurement With the POWER button depressed, continuous measurement POWER
(Laser irradiate symbol is displayed.) is possible for up to 20 seconds. (When done, 4-3 display appear)
4-3 Failure to measure Repeat step 4-1.
4-4 Measurement OK Horizontal distance 201 220 660
Follow by 4-5 or 4-1.
4-5 Data display after
switching modes (1) Height (from horizontal)【5】MODE
45.0 49.2 146
(2) Angle (from horizontal)【6】MODE 13 -13
(3) Vertical separation (height between two points)【7】MODE blinks
(4) Linear distance【3】MODE 206 225 676
(5) Horizontal distance MODE 201 220 660
Return to 4-5-(1), then repeat. MODE
(In Limited mode, return to 4-5-(1), then repeat (1), (4) and (5))
Operation/Results Work Button Display Display examples
meter yards feet
Elevation(°) Depression(°)
3 Measurement with Linear distance mode
3-1 Seeking your target Linear distance
(Align the reticle with target)
3-2 Measurement With the POWER button depressed, continuous measurement POWER
(Laser irradiate symbol is displayed.) is possible for up to 20 seconds. (When done, 3-3 display appears.)
3-3 Failure to measure Repeat step 3-1.
3-4 Measurement OK Linear distance 206225 676
Follow by 3-5 or 3-.1
3-5 Data display after
witching modes (1) Horizontal distance【4】 MODE 201 220 660
(2) Height (from horizontal)【5】MODE 45.0 49.2 146
(3) Angle (from horizontal)【6】MODE 13 -13
(4) Vertical separation (height between 2 points)【7】
MODE blinks
(5) Linear distance MODE 206 225 676
Return to 3-5-(1) and repeat. MODE
(In Limited mode, return to 3-5-(1), then repeat (1),(2) and (5))
【0 • 1 • 2】 Power On/Off and others
See the relevant section in this manual for each mode setting and display.
【3】 Linear distance mode
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode.
The angle and vertical
separation (height between
two points) are displayed
when set at FULL mode.
Limited mode shows linear
distance, horizontal distance
and height.
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
Measuring procedures and internal display
【4】Horizontal distance mode
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode.
The angle and vertical
separation (height between
two points) are displayed
when set at FULL mode.
Limited mode shows linear
distance, horizontal distance
and height.
Operation/Results Work Button Display Display examples
meter yards feet
Elevation(°) Depression(°)
6 Measurement with angle mode setting (only at FULL mode setting)
6-1 Seeking your target Angle (from horizontal)
(Align the reticle with target.)
6-2 Measurement With the POWER button depressed, continuous measurement POWER
(Laser irradiate symbol is displayed.) is possible for up to 20 seconds. (When done 6-3 display appears)
6-3 Failure to measure Repeat step 6-1.
6-4 Measurement OK Angle (from horizontal) 13 -13
Follow by 6-5 or 6-1. 5.2 -5.2
6-5 Data display after
switching modes (1) Vertical separation between two points【7】MODE
blinks
(2) Linear distance【3】MODE 206 225 676
(3) Horizontal distance【4】MODE 201 220 660
(4) Height (from horizontal)【5】MODE 45.0 49.2 146
(5) Angle (from horizontal) MODE 13 -13
Return to 6-5-(1), then repeat.
Operation/Results Work Button Display Display examples
meter yards feet
Elevation(°) Depression(°)
5 Measurement with height mode
5-1 Seeking your target Height (from horizontal)
(Align the reticle with target)
5-2 Measurement With the POWER button depressed, continuous measurement POWER
(Laser irradiate symbol is displayed.) is possible for up to 20 seconds. (When done, 5-3 display appear)
5-3 Failure to measure Repeat step 5-1.
5-4 Measurement OK Linear distance 45.0 49.2 146
Follow by 5-5 or 5-1.
5-5 Data display after
switching modes (1) Angle(from horizontal)【 6】MODE 13 -13
(2) Vertical separation (height between two points)【7】MODE blinks
(3) Linear distance【3】MODE 206 225 676
(4) Horizontal distance【4】MODE 201 220 660
(5) Height (from horizontal) MODE 45.0 49.2 146
Return to 5-5-(1) and repeat. MODE
(In Limited mode, return to 5-5-(3),
then repeat (3), (4) and (5).
【5】Height mode
【6】Angle mode
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode.
See the relevant section.
The angle and vertical
separation (height between
two points) are displayed
when set at FULL mode.
Limited mode shows linear
distance, horizontal distance
and height.
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
【7】Vertical separation (height between two points) mode
Operation/Results Work Button Display Display examples
meter yards feet
Elevation(°) Depression(°)
7 Measurement with Vertical separation (height between two points) mode (only at FULL mode setting)
7-1 Seeking your target Vertical separation (height between two points) blinks
(Align the reticle with target) (1st target)
7-2 Measurement POWER
(Laser irradiate symbol is displayed)
7-3 Failure to measure Follow by 7-1
blinks
Repeat 7-1, 7-2, 7-3 until measurement is complete.
7-4 Measurement OK Height of 1st target (from Horizontal)
blinks
104 114 341
followed by 7-5 or 7-6.
7-5 Data display after (1) Linear distance (1st target)【3】MODE 247 270 810
switching modes (2) Horizontal distance (1st target)【4】MODE 224 245 735
(3) Height (from horizontal) (1st target)【5】MODE 104 114 341
(4) Angle (from horizontal) (1st target)【6】MODE 25
(5) Vertical separation (height between two points) MODE
blinks
0.0 0.0 0.0
7-5-(follow by 6-1 or 6-2)
(6-1) Return to 7-5-(1), then repeat. MODE
(6-2) follow by 7-3 or 7-4 After aiming, POWER
7-6 Aiming (2nd target) Vertical separation (height between two points)
blinks
104 114 341
(Align the reticle with target) (2nd target)
(Result shown is the height of the 1st target)
7-7 Measurement POWER
(Laser irradiate symbol is displayed)
7-8 Failure to measure Follow by 7-6 blinks
Repeat 7-6,7-7 and 7-8 until measurement is complete
7-9 Measurement OK Vertical separation (height between two points) 64.0 70.0 210
After 2 seconds move to7-10
7-10 Vertical separation (height between two points) blinks 64.0 70.0 210
Follow by 7-11 or 7-1
7-11 Date display after (1) Linear distance (2nd target)【3】MODE 228 249 898
switching modes (2) Horizontal distance (2nd target)【4】MODE 224 245 735
(3) Height (from horizontal) (2nd target)【5】MODE 40.0 43.8 131
(4) Angle (from horizontal) (2nd target)【6】MODE 10
(5) Vertical separation (height between two points) MODE
blinks
64.0 70.0 210
Follow by 7-11-(6-1) or 7-11-(6-2)
(6-1) Return to 7-11-(1), then repeat MODE
(6-2) Follow by 7-3 or 7-4 After aiming POWER
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode
See the relevant section.
If the mode is switched, the
2nd target cannot be
measured
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode
See the relevant section.
Switching the measurement
unit changes it for each
mode. The POWER button
can be used to measure in
each mode
See the relevant section.
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
8 Power off Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without operation
Other Nikon Measuring Instrument manuals

Nikon
Nikon Forestry Pro User manual

Nikon
Nikon COOLSHOT LITE User manual

Nikon
Nikon Forestry Pro II User manual

Nikon
Nikon Coolshot 40i User manual

Nikon
Nikon COOLSHOT 20 GII User manual

Nikon
Nikon 50i User manual

Nikon
Nikon Nivo 2.C User manual

Nikon
Nikon Callaway LR550 User manual

Nikon
Nikon Prostaff 1000i User manual

Nikon
Nikon Coolshot 40i User manual

Nikon
Nikon Monarch 7iVR User manual

Nikon
Nikon CoolShot Pro Stabilized User manual

Nikon
Nikon N Series User manual

Nikon
Nikon HQA46480 User manual

Nikon
Nikon Prostaff 7i User manual

Nikon
Nikon XF SERIES User manual

Nikon
Nikon DTM-350 User manual

Nikon
Nikon DTM-502 Series User manual

Nikon
Nikon PROSTAFF 3i User manual

Nikon
Nikon Nivo Series User manual