Peak Reading with Auto Reset
When Torque is applied, the NorTronic® will track the torque input until it has exceeded the Active From
setting (See page 19) and then enters into peak mode for both Torque & Angle.
The angle display is shown as “0°” until the torque is above the Active From setting for the tool. If the Snug
Torque is set, the angle display is shown as “0°” until the torque reaches the Snug Torque value (see page
13) and then displays the angle value in peak mode.
When a peak torque or angle has been applied after which the torque has dropped below the Active From
setting, both the torque & angle readings continuously flash for the duration of the Hold Time (see page 21).
The displays are then reset to the current torque input.
If the Save button (which now becomes latching) has been pressed prior to the Peak being
detected, the Torque & Angle readings are saved to the Data Store on the NorTronic®.
If a Target is in use, press the UP button to delete the last reading that has been saved via
the Delete Last Result? confirmation screen.
Delete
Last Result ?
Y / N
Tool Target
Having already set a Tool Target (see page 13 for more details), the NorTronic® beeps as the applied torque
approaches the Torque Target (starting slow and getting faster) until a continuous tone is heard when the
Target has been reached. This stops after the Torque has been released.
The Torque & Angle digits will be shown as:
White = below Active From setting or no Target set
Yellow = above Active From setting, but below Target Lower Limit
Green = above Target Lower Limit and below Target Upper Limit
Red = above Target Upper Limit
The tool Vibrates when the Torque Target or Angle Target has been reached (if enabled in SETUP –
Vibrate, see page 20 for more information).
TIP: If an angle only target has been set, the beeper sounds as the user approaches the angle
target, quickening in frequency until a continuous tone when the angle target has been
reached.