manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OHAUS
  6. •
  7. Scale
  8. •
  9. OHAUS Valor 2000 User manual

OHAUS Valor 2000 User manual

Other OHAUS Scale manuals

OHAUS valor 5000 series User manual

OHAUS

OHAUS valor 5000 series User manual

OHAUS CS Series User manual

OHAUS

OHAUS CS Series User manual

OHAUS Ranger 3000 Series User manual

OHAUS

OHAUS Ranger 3000 Series User manual

OHAUS MB90/MB120 User manual

OHAUS

OHAUS MB90/MB120 User manual

OHAUS Valor V71P1502T User manual

OHAUS

OHAUS Valor V71P1502T User manual

OHAUS VN Series User manual

OHAUS

OHAUS VN Series User manual

OHAUS TAJ Carat TAJ203 User manual

OHAUS

OHAUS TAJ Carat TAJ203 User manual

OHAUS Adventurer AX224N User manual

OHAUS

OHAUS Adventurer AX224N User manual

OHAUS defender 7000 User manual

OHAUS

OHAUS defender 7000 User manual

OHAUS DEFENDER SERIES User manual

OHAUS

OHAUS DEFENDER SERIES User manual

OHAUS Ranger R21PE1502 User manual

OHAUS

OHAUS Ranger R21PE1502 User manual

OHAUS Catapult 1000 User manual

OHAUS

OHAUS Catapult 1000 User manual

OHAUS TROOPER SCALE User manual

OHAUS

OHAUS TROOPER SCALE User manual

OHAUS ES6R User manual

OHAUS

OHAUS ES6R User manual

OHAUS DCR250 User manual

OHAUS

OHAUS DCR250 User manual

OHAUS PR Series User manual

OHAUS

OHAUS PR Series User manual

OHAUS Ranger User manual

OHAUS

OHAUS Ranger User manual

OHAUS SCOUT II User manual

OHAUS

OHAUS SCOUT II User manual

OHAUS EXPLORER User manual

OHAUS

OHAUS EXPLORER User manual

OHAUS Ranger RP Compact Scales User manual

OHAUS

OHAUS Ranger RP Compact Scales User manual

OHAUS EC Series User manual

OHAUS

OHAUS EC Series User manual

OHAUS Scout pro User manual

OHAUS

OHAUS Scout pro User manual

OHAUS EB3 User manual

OHAUS

OHAUS EB3 User manual

OHAUS valor 5000 series User manual

OHAUS

OHAUS valor 5000 series User manual

Popular Scale manuals by other brands

Omron HN-286 null

Omron

Omron HN-286 null

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Axis B/E Series user manual

Axis

Axis B/E Series user manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

Rice Lake MSI-4260 IS Technical manual

Rice Lake

Rice Lake MSI-4260 IS Technical manual

IKA RCT basic safety control operating instructions

IKA

IKA RCT basic safety control operating instructions

ADE M20011 operating manual

ADE

ADE M20011 operating manual

Duronic KS3000 manual

Duronic

Duronic KS3000 manual

Digi SM-720 Service manual

Digi

Digi SM-720 Service manual

Cardinal CS Series Operation manual

Cardinal

Cardinal CS Series Operation manual

Korona Kastella Instructions for use

Korona

Korona Kastella Instructions for use

A&D FC-50Ki instruction manual

A&D

A&D FC-50Ki instruction manual

BDA CAMARGUE installation guide

BDA

BDA CAMARGUE installation guide

Tanita HD-357 Instructions for use

Tanita

Tanita HD-357 Instructions for use

Leifheit 03173 quick start guide

Leifheit

Leifheit 03173 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Start Guide Valor™2000
Ohaus Corporation www.ohaus.com iValor
™
2000 Quick Start Guide
PREPARATION FOR USE
IMPORTANT: Unscrew the two rear leveling
feet slightly, to allow proper airflow inside the
scale, and relieve any internal pressure. Then
level the scale.
Before cleaning the scale, the rear leveling
feet must be screwed in tightly to avoid entry
of water inside the scale.
AC power may be used when battery power is
not available. Remove the rubber seal in the
back. Connect the AC adapter plug to the
input jack and plug it into a power outlet.
Note: To prevent water ingress during use,
insert rubber Seal into the input jack recess.
SELECTING THE LOCATION
Place on a firm, steady surface.
Avoid locations with excessive air current,
vibrations, heat sources, or rapid temperature
changes.
Level the scale: Adjust leveling feet so bubble
is centered.
SAFETY PRECAUTIONS
For safe and dependable operation of this product, please comply with the following
safety precautions:
•Verify that the input voltage printed on the power Adapter and the plug type matches
the local power supply.
•Make sure that the power cord does not pose an obstacle or tripping hazard.
•Disconnect the product from the power supply when cleaning.
•Do not operate this product in hazardous or unstable environments.
•Do not drop loads on the pan.
•Use only approved accessories and peripherals, as available.
•Operate the product only under ambient conditions specified in the Instruction Manual.
•Service should be performed by authorized personnel only.
Level
Bubble
Seal
Leveling
Feet
Valor™2000 Quick Start Guide
Valor
™
2000 Quick Start Guide ii Ohaus Corporation www.ohaus.com
CONTROLS
Front Display
Rear Display
Button
Primary Function
(Short Press)
ON/ >O/T<
Turns scale ON.
If scale is On: Sets zero.
Performs a tare operation.
UNITS
Changes the weighing Unit.
Secondary Function
(Long Press)
Off
Turns scale off.
Menu
Enter the User menu.
Menu Function
(Short Press)
Yes
Accepts the current setting
on the display.
No
Advances to the next menu
or menu item.
Rejects the current setting on
the display and advances to
the next available setting.
Quick Start Guide Valor™2000
Ohaus Corporation www.ohaus.com iii Valor
™
2000 Quick Start Guide
OPERATION
Turning Scale On/Off
Press ON. The scale performs a display test, displays the model/software
version, and then enters the active weighing mode.
To turn the scale off, press and hold Off until OFF is displayed.
Zero Operation
Press 0/T to zero the weight display. The scale must be stable to accept
zero operation.
Manual Tare
Place a container on the weighing pan and press 0/T.
The display shows a net value of “0”.
To clear the Tare value, press 0/T with the pan empty.
Changing Units of Measure
Press UNITS to display the next available measuring unit.
Choose from kg, g, lb, and oz.
Only measuring units enabled in the Unit Menu will be displayed.
(See back page.)
Verify the scale: place a known mass on it and check if the reading is accurate.
If not, calibrate, using the Calibration Guide.
Valor™2000 Quick Start Guide
Valor
™
2000 Quick Start Guide iv Ohaus Corporation www.ohaus.com
MENU NAVIGATION
Press and hold Menu until MENU is displayed, then release it.
Press Yes to enter the displayed menu or press No to advance to the next menu.
When viewing the menu setting, press Yes to accept the setting, or press No to change it, then
press Yes to accept the setting and move to the next menu.
When End is displayed, press Yes to exit the menu.
MENU STRUCTURE
Programmable features of the Valor 2000 scales are contained in menus which are accessed
through the Display Panel’s control switches. See the Instruction Manual for more details.
*When LFT is ON, the Calibration, Resolution, Unit, and AZT menus are inaccessible.
*80252980*
P/N 80252980