PNSPO!
Model
NQ3- MQ000B
NQ3- TQ000B
NQ5- SQ000B
NQ5- SQ001B
NQ5- MQ000B
NQ5- MQ001B
NQ HMI SERIES
INSTRUCTION SHEET
Thank you for purchasing this OMRON product. Please read
this instruction sheet and thoroughly familiarize yourself with
the functions and characteristics of the product before use.
Please retain this sheet for future reference.
For more information on specifications and usage, please refer
to NQ-Series HMI Operation Manual.
OMRON Corporation
© 2009 OMRON Europe BV All rights reserved 1111868-7A
General Precautions
The user must operate the product according to the performance
specifications described in the operation manual.
Before using the product under conditions which are not described in
the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical
equipment, amusement machines, safety equipment, petrochemical
plants, and other systems, machines, and equipment that may have a
serious influence on lives and property if used improperly, consult your
OMRON representative.
Make sure that the ratings and performance characteristics of the
product are sufficient for the systems, machines, and equipment, and
be sure to provide the systems, machines, and equipment with double
safety mechanisms.
•The NQ-series HMI (referred to as “HMI”) is a general purpose
product. It is a system component and is used in conjunction with
other items of industrial equipment such as PLC’s. Loop
Controllers, Adjustable Speed Drives, etc.
•A detailed system analysis and job safety analysis should be
performed by the system designer or system integrator before
including the HMI unit in any new or existing system. Consult your
OMRON representative for options availability and for application
specific system integration information if required.
•The product may be used to control an adjustable speed drive
connected to high voltage sources and rotating machinery that is
inherently dangerous if not operated safely. Interlock all energy
sources, hazardous locations, and guards in order to restrict the
exposure of personnel to hazards. The adjustable speed drive may
start the motor without warning. Signs on the equipment
installation must be posted to this effect. A familiarity with auto-
restart settings is a requirement when controlling adjustable speed
drives. Failure of external or ancillary components may cause
intermittent system operation, i.e., the system may start the motor
without warning or may not stop on command. Improperly
designed or improperly installed system interlocks and per
missives may render a motor unable to start or stop on command.
■Safety Precautions
Definition of Precautionary Information
WARNING Indicates a potentially hazardous situation
which. If not avoided, could result in death or
serious injury.
Caution Indicates a potentially hazardous situation,
which, if not avoided, may result in minor or
moderate injury, or property damage.
■Warnings and Cautions
WARNING Do not attempt to take any HMI apart or touch
any internal parts while the power is being
supplied. Doing so may result in electric
shock.
WARNING Do not touch any of the terminals or terminal
blocks while the power is being supplied.
Doing so may result in electric shock.
WARNING Do not attempt to disassemble, repair, or
modify any HMI. Any attempt to do so may
result in malfunction, fire, or electric shock.
WARNING Provide safety measures in external circuits,
i.e., not in the HMI, in order to ensure safety
in the system if an abnormality occurs due to
malfunction of the HMI or another external
factor affecting the HMI operation. Not doing
so may result in serious accidents.
•Emergency stop circuits, interlock circuits, limit circuits, and simila
r
safety measures must be provided in external control circuits.
WARNING Never short-circuit the positive and negative
terminals of the batteries, charge the batteries,
disassemble them, deform them by applying
pressure, or throw them into a fire. The
batteries may explode, combust or leak liquid.
WARNING Fail-safe measures must be taken by the
customer to ensure safety in the event of
incorrect, missing, or abnormal signals caused
by broken signal lines, momentary power
interruptions, or other causes. Not doing so
may result in serious accidents.
WARNING The HMI will turn OFF when its self-diagnosis
function detects any error. As a
countermeasure for such errors, external
safety measures must be provided to ensure
safety in the system.
Caution Pay careful attention to the polarities (+/-)
when wiring the DC power supply. A wrong
connection may cause malfunction of the
system.
Caution Confirm safety at the destination HMI before
transferring a program or settings to another
HMI. Doing this without confirming safety may
result in injury.
Caution Tighten the screws on the terminal block of
the Power Supply connector to the torque
specified in the operation manual. The loose
screws may result in burning or malfunction.
■Operating Environment Precautions
Caution Do not operate the HMI in the following
locations. Doing so may result in malfunction,
electric shock or burning:
•Locations subject to direct sunlight
•Locations subject to temperatures or humidity outside the range
specified in the specifications
•Locations subject to condensation as the result of severe
changes in temperature
•Locations subject to corrosive or flammable gases
•Locations subject to dust (especially iron dust) or salts
•Locations subject to exposure to water, oil, or chemicals
•Locations subject to shock or vibration
Caution Take appropriate and sufficient
countermeasures when installing systems in
the following locations. Doing so may result
in malfunction:
•Locations subject to static electricity or other forms of noise
•Locations subject to strong electromagnetic fields
•Locations subject to possible exposure to radioactivity
•Locations close to power supplies
Caution The operating environment of the HMI System
can have a large effect on the longevity and
reliability of the system. Improper operating
environments can lead to malfunction, failure, and
other unforeseeable problems with the HMI
System. Make sure that the operating
environment is within the specified conditions at
installation and remains within the specified
conditions during the life of the system.
■Application Precautions
WARNING Failure to abide by the following
precautions could lead to serious or
possibly fatal injury. Always read these
precautions.
•Always connect to a ground of 100 Ωor less when installing the HMI.
Not doing so may result in electric shock. Always connect to a
ground of 100 Ωor less when short-circuiting the functional ground
and line ground terminals of the Power Supply Unit, in particular.
•Always turn OFF the power supply to the HMI before attempting any
of the following. Not turning OFF the power supply may result in
malfunction or electric shock.
•Mounting or dismounting Power Supply units and Control Units
•Assembling option boards on HMI
•Replace the battery
•Setting switches
•Connecting or wiring the cables
•Connecting or disconnecting the connectors
•Check the user program for proper execution before actually running
it on the HMI. Not checking the program may result in an unexpected
operation.
Caution Failure to abide by the following precautions could
lead to faulty operation of the HMI or the system, or
could damage the HMI. Always read these
precautions.
•Install external breakers and take other safety measures against short-
circuiting in external wiring. Not observing this may result in burning.
•Be sure that all the terminal screws and cable connector screws are
tightened to the torque specified in the relevant manuals. Incorrect
tightening torque may result in malfunction.
•Mount the HMI only after checking the connectors and terminal blocks
completely.
•Before touching the HMI, be sure to first touch a grounded metallic
object in order to discharge any static built-up. Not doing so may result
in malfunction or damage.
•Be sure that the terminal blocks, connectors, and other items with
locking devices are properly locked into place. Improper locking may
result in malfunction.
•Wire correctly according to the specified procedures.
•Always use the power supply voltage specified in the operation
manuals. An Incorrect voltage may result in malfunction or burning.
•Do not connect an AC power supply to the HMI power terminals, an
incorrect power supply may result in burning.
•Take appropriate measures to ensure that the specified power with the
rated voltage and frequency is supplied. Be particularly careful in
places where the power supply is unstable. An incorrect power supply
may result in malfunction.
•Use crimp terminals for wiring. Do not connect bare stranded wires
directly to terminals. Connection of bare stranded wires may result in
burning.
•Disconnect the functional ground terminal when performing withstand
voltage tests. Not disconnecting the functional ground terminal may
result in burning.
•Wire correctly and double-check all the wiring or the setting switches
before turning ON the power supply. Incorrect wiring may result in
burning.
•Check that the switches and settings are properly set before starting
operation.
•Resume operation only after transferring to the new HMI the contents
of the all settings, programs, parameters, and data required for
resuming operation. Not doing so may result in an unexpected
operation.
•Do not pull on the cables or bend the cables beyond their natural limit.
Doing either of these may break the cables.
•Do not place objects on top of the cables. Doing so may break the
cables.
•Use the dedicated connecting cables specified in operation manuals to
connect the HMI. Using commercially available RS-232C computer
cables may cause failures in external devices or the HMI.
•When replacing parts, be sure to confirm that the rating of a new part is
correct. Not doing so may result in malfunction or burning.
•When transporting or storing the product, cover the PCBs with
electrically conductive materials to prevent LSls and ICs from being
damaged by static electricity, and also keep the product within the
specified storage temperature range.
•Do not touch the mounted parts or the rear surface of PCBs because
PCBs have sharp edges such as electrical leads.
•Make sure that parameters are set correctly. Incorrect parameter
settings may result in unexpected operations. Make sure that
equipment will not be adversely affected by the parameter settings
before starting or stopping the HMI.
•Do not press the touch screen and switches with a sharp pointer or
pencil, doing so may result in malfunction or damage.
•Do not press the touch screen and switches with a force greater than
30N, doing so may result in malfunction or damage.
•Always following the specified procedure when removing the USB-
stick. Removing the USB-stick while it is being accessed may render
the USB-stick unusable.
•Please make sure to have a backup of the data already present on
the USB-stick before connecting it with HMI. Not doing so may result
in lost of data.
•Do not let metal particles enter the HMI when preparing the panel.
•Do not use benzene, paint thinner, or other volatile solvents and do
not use chemically treated cloths.
•Carefully unpack the equipment and check for parts that were
damaged from shipping, missing parts, or concealed damage. If any
discrepancies are discovered, it should be noted with the carrier
prior to accepting the shipment, if possible. File a claim with the
carrier if necessary and immediately notify your OMRON
representative.
•Do not install or energize equipment that has been damaged.
Damaged equipment may fail during operation resulting in further
equipment damage or personal injury.
■Handling, Storage and Disposal
•Use proper lifting techniques when moving the HMI; including
properly sizing up the load, and getting assistance if required.
•Store in a well-ventilated covered location and preferably in the
original packaging if the HMI will not be used upon receipt.
•Store in a cool, clean, and dry location. Avoid storage locations with
extreme temperatures, rapid temperature changes, high humidity,
moisture, dust, corrosive gases, or metal particles.
•Do not store the HMI in places that are exposed to outside weather
conditions (i.e., wind, rain, snow, etc.).
•Never dispose electrical components via incineration. Contact your
state environmental agency for details on disposal of electrical
components and packaging in your area.
■Compliance with EC Directives
•This product is EMC compliant when assembled in a complete PLC
system of the specified PLC Series. Refer to the NQ-series HMI
Operation manual for grounding, cable selection, and any other
conditions for EMC compliance.
•This is a class A product. It may cause radio interference in
residential areas, in which case the user may be required to take
adequate measures to reduce interference.
■Unit Assembly Precautions
•Install the Unit properly as specified in the hardware manual.
Improper installation of the Unit may result in malfunction.
■Reference Manuals
Please be sure to read the related user manuals to use the HMI
safely and properly. Be sure you are using the most current version
of the manual.
Name Cat No.
NQ-series HMI Operation Manual V07-EN-01
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of products in the
customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Please know and observe all prohibitions of use applicable to the
products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE
RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also product catalogs for Warranty and Limitations of Liability.
24V 0V
1. Parts and Functions
This page shows the front and back panels of the NQ3 and NQ5
terminals, and explains the parts and functions.
■Front Panel
NQ3 / NQ5 terminals.
Image shows NQ3 terminal. NQ5 has the same view and has one
more Function Key (F6).
■Back Panel
NQ3
NQ5
2. External Dimensions
NQ (Landscape)
Dimensions in mm
Dimension table
Height Width Depth
NQ3 128mm 102mm 44.7mm
NQ5 195mm 142mm 50.2mm
NQ5 (Portrait)
For NQ5 Portrait models the terminal is rotated by 90 degrees. The
cable connections are located on the LEFT side for Portrait models
(viewed from front of terminal).
3. Connector and Pin Layout
■NQ3 / NQ5 - COM1
RS-232 / RS-422 / RS-485: (DSUB9, Female)
Pin
number Signal name
1 TX+ Transmit + RS-422
2 TXD Transmit RS-232
3 RXD Receive RS-232
4 RX+ Receive + RS-422
5 GND Signal Ground
6 NC Not connected
7 NC Not connected
8 TX- Transmit - RS-422
9 RX- Receive - RS-422
Shell Shield
Note: To use the two wire method (RS-485) short the TX+ and RX+
signals and short the TX- and RX- signals.
For network termination add a resistor of 120 OHM between pin 4
and pin 9 on the Dsub9 connector.
■NQ5 - COM2
RS-232: (DSUB9, Female)
Pin
number Signal name
1 NC Not connected
2 TXD Transmit RS-232
3 RXD Receive RS-232
4 NC Not connected
5 GND Signal Ground
6 NC Not connected
7 NC Not connected
8 NC Not connected
9 NC Not connected
Shell Shield
■NQ3 / NQ5 - Power Cable Connection
The terminals for connecting the 24V-DC power
supply are located on the green 3-pin connector.
Connect the 3-pin connector as follows.
The back side of the HMI is also marked accordingly.
■NQ3 / NQ5 - USB HOST
USB series “A” Receptacles: (A, Female)
Pin
number Signal name
1 VBUS +5V
2 D- DATA -
3 D+ DATA +
4 GND Signal Ground
Shell Shield
■NQ3 / NQ5 - USB Device (Slave)
USB series “B” Receptacles: (B, Female)
Pin
number Signal name
1 VBUS +5V
2 D- DATA -
3 D+ DATA +
4 GND Circuit Ground
Shell Shield
4. LED status
LED Back
Light Action Status/Solution
OFF OFF
Press the touch
screen. The back
light does not come
on.
Failure in the power
supply. Check the power
supply and connections.
OFF ON
Check the LED bit
s36. The LED bit
s36 is turned off.
The LED status bit s36 is
turned off. Turn the LED
status bit s36 on.
ON OFF
Press the touch
screen. The back
light comes on.
The terminal in screen
saver mode.
ON ON
- The terminal is working
correctly.
ON
(flashing
slowly)
ON
- The terminal is working
correctly and is down/up-
loading
ON
(flashing
fast)
ON
Check
communication
connections.
The terminal is working
correctly and is in com-
munication error mode.
5. Contents of box
Qty Description
1 Instruction Sheet
1 NQ-series HMI
4 Mounting Clamp
1 Power connector
6. Battery Replacement
The battery service life is approximately 5 years at 25°C. The service
life will be shortened if the battery is used at higher temperatures.
Replace the battery periodically, according to the operating
environment. For details, refer to the NQ-series HMI Operation
Manual.
7. Installation in a Control Panel
The NQ terminals are normally mounted in a panel. Read the
following instructions on how to mount the system.
•Create an opening in the panel.
Panel thickness: 6.0 mm max.
Dimension table
Height
cut-out Width
cut-out
NQ3 119 (0/+0.5)mm 93 (0/+0.5)mm
NQ5 184 (0/+0.5)mm 131 (0/+0.5)mm
•Ensure that the gasket is properly mounted.
•Secure the NQ, with the provided mounting clamps
to the panel.
To maintain water and dust resistant performance, the
tightening torque must be between 0.5 and 0.6Nm.
PNSPO!
OMRON EUROPE BV
Wegalaan 67-69, NL- 2132 JD Hoofddorp
The Netherlands
Tel: (31) 23-5681300 / Fax: (31) 23-5681388
Note: Specification subject to change without notice.
Printed in India.
Height
Width
Height
Power Input Com1 Com2 USB Host USB Slave
Terminals
Power Input Com1 USB slave USB Host
Terminals
Function Keys
Touch area
Width

This manual suits for next models

6

Other Omron Controllers manuals

Omron CK3M-CPU 1 Series User guide

Omron

Omron CK3M-CPU 1 Series User guide

Omron SYSMAC PLC Basic Quick start guide

Omron

Omron SYSMAC PLC Basic Quick start guide

Omron NJ501-4500 User manual

Omron

Omron NJ501-4500 User manual

Omron SGE Series User manual

Omron

Omron SGE Series User manual

Omron NJ501-1300 User manual

Omron

Omron NJ501-1300 User manual

Omron NX Series User manual

Omron

Omron NX Series User manual

Omron CVM1D User manual

Omron

Omron CVM1D User manual

Omron SYSMAC C200HS User manual

Omron

Omron SYSMAC C200HS User manual

Omron G9SP-N20S Installation manual

Omron

Omron G9SP-N20S Installation manual

Omron SYSMAC C200H-FZ001 User manual

Omron

Omron SYSMAC C200H-FZ001 User manual

Omron Z500 Series User guide

Omron

Omron Z500 Series User guide

Omron E5AK-T User manual

Omron

Omron E5AK-T User manual

Omron V700 series User manual

Omron

Omron V700 series User manual

Omron NB-series User manual

Omron

Omron NB-series User manual

Omron E5AN User manual

Omron

Omron E5AN User manual

Omron CJ1W-CORT21 User manual

Omron

Omron CJ1W-CORT21 User manual

Omron E5CD User manual

Omron

Omron E5CD User manual

Omron G3ZA User manual

Omron

Omron G3ZA User manual

Omron ES100 User manual

Omron

Omron ES100 User manual

Omron G3ZA User manual

Omron

Omron G3ZA User manual

Omron SYSMAC CV500 User manual

Omron

Omron SYSMAC CV500 User manual

Omron R88A-MCW151 Series User manual

Omron

Omron R88A-MCW151 Series User manual

Omron CJ1M-CPU series Parts list manual

Omron

Omron CJ1M-CPU series Parts list manual

Omron ZS-MDC User manual

Omron

Omron ZS-MDC User manual

Popular Controllers manuals by other brands

Evco EVRS225 manual

Evco

Evco EVRS225 manual

Panasonic AFPX-C30R user manual

Panasonic

Panasonic AFPX-C30R user manual

WELBA WTS-300 Installation and operating instructions

WELBA

WELBA WTS-300 Installation and operating instructions

NeuroDigital Avatar VR quick start guide

NeuroDigital

NeuroDigital Avatar VR quick start guide

RKC INSTRUMENT CB100 Series instruction manual

RKC INSTRUMENT

RKC INSTRUMENT CB100 Series instruction manual

Renesas R-IN32M3 Series user manual

Renesas

Renesas R-IN32M3 Series user manual

Penta KB Power SIMG Installation and operating instructions

Penta KB Power

Penta KB Power SIMG Installation and operating instructions

Morningstar TriStar Professional TS-60M Installation, operation and maintenance manual

Morningstar

Morningstar TriStar Professional TS-60M Installation, operation and maintenance manual

Preferred JC-23D2 Installation & operation instructions

Preferred

Preferred JC-23D2 Installation & operation instructions

Precision Digital Corporation ConsoliDator+ instruction manual

Precision Digital Corporation

Precision Digital Corporation ConsoliDator+ instruction manual

Rosenberg RE Series Operating	 instruction

Rosenberg

Rosenberg RE Series Operating instruction

Chamberlain 811LM manual

Chamberlain

Chamberlain 811LM manual

Energy Technology OCEM AUGIER DIAM4200 Series Installation & maintenance

Energy Technology

Energy Technology OCEM AUGIER DIAM4200 Series Installation & maintenance

Johnson Controls G670 Installation sheet

Johnson Controls

Johnson Controls G670 Installation sheet

Signet 8860 user manual

Signet

Signet 8860 user manual

ADTRAN NetVanta 5305 quick start guide

ADTRAN

ADTRAN NetVanta 5305 quick start guide

BGS technic 8603 instruction manual

BGS technic

BGS technic 8603 instruction manual

HomeMatic HmIPW-DRBL4 Installation instructions and operating manual

HomeMatic

HomeMatic HmIPW-DRBL4 Installation instructions and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.