Omron A3C Series Programming manual

CSM_A3C_DS_E_2_1
1
A3C
Pushbutton Switch (Lighted/Non-Lighted) (Cylindrical 12-dia.)
Pushbutton Switch Series with
Cylindrical 20-mm ×12-dia. Body
• High-intensity uniform surface lighting.
• Round body enables easy hole making.
• Miniature size with excellent feeling of operation.
RoHS Compliant
Refer to Safety Precautions for All Pushbutton Switches and
Safety Precautions on page 12.
List of Models
Appearance Model
Rectangular
Models A3CJ
Square
Models A3CA
Round
Models A3CT
■Specifications: Refer to page 8. ■Dimensions: Refer to page 10. ■Accessories: Refer to page 7.
■Precautions for correct use and safety precautions: Refer to page 12.

A3C
2
Model Number Legend .............................................When placing your order, specify the individual component part model numbers of
the Pushbutton, Lamp (lighted models only), and Switch, as listed in the ordering
tables below.
For information on combinations, refer to Ordering Information on page 3.
(1) (2) (3) (4) (5) (6)
A3C J - 9 0 A 1 - 24E R
(1) Shape of
Pushbutton
Sym-
bol
Shape
JRectan-
gular
A Square
T Round
(6) Color of
Pushbutton
For LED
Lamp
For
Incandescent
Lamp
For Non-
lighted
Models
Sym-
bol
Color
R
Red
Y
Yellow
G
Green
W
White
Sym-
bol
Color
R
Red
Y
Yellow
G
Green
A
Blue
W
White
Sym-
bol
Color
R
Red
Y
Yellow
G
Green
W
White
A
Blue
B
Black
(3) Switch Specifications
Standard Load
Microload
• Standard Load
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
• Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Minimum applicable load
1 mA at 5 VDC
Momentary-action: Self-resetting
Alternate-action: Self-holding
Sym-
bol
Operation
AMomentary
1a1b
B Alternate
Sym-
bol
Operation
EMomentary
1a1b
F Alternate
(4) Lighted/Non-
lighted
• Colored-illumina-
tion models are
also available.
Refer to page 4.
"Colored-illumi-
nation" models
operate in the
way shown be-
low:
Sym-
bol
Type
0
Non-lighted
1
Illumination
only
(5) Lighting
Method
LED Lamp-lighted
Models
Incandescent
Lamp-lighted
Models
Non-lighted
Models
No symbol
Sym-
bol
Operating
voltage
05E
5 VDC
12E
12 VDC
24E
24 VDC
Sym-
bol
Operating
voltage
06
5 VAC/VDC
14
12 VAC/VDC
28
24 VAC/VDC
White Color
The built-in LED
is colored.
Unlit Lit
(2) Terminal Type
Sym-
bol
Type
0 Solder terminal

A3C
3
Ordering Information
Ordering as a Set ................................ The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp (lighted models only), and Switch.
Lighted Pushbutton Switches (SPST-NO+SPST-NC Solder Terminals)
Note: 1. Enter the desired color symbol for the Pushbutton in the @at the end of the model number.
2. There are also alternate-operation models that can be used for microloads. Refer to the Switch table on page 6.
* Black ("B") Pushbuttons are only available for non-lighted models.
Operation Standard load Microload
Momentary operation (Self-resetting) Alternate operation (Self-holding) Momentary operation (Self-resetting)
Pushbutton
color symbol
(Color)
Shape Lighting Set Set Set
Rectangular
(A3CJ)
LED lamp
A3CJ-90A1-05E@A3CJ-90B1-05E@A3CJ-90E1-05E@R: red
Y: yellow
G: green
W: white
A3CJ-90A1-12E@A3CJ-90B1-12E@A3CJ-90E1-12E@
A3CJ-90A1-24E@A3CJ-90B1-24E@A3CJ-90E1-24E@
Incandescent
lamp
A3CJ-90A1-06@
--- ---
R: red
Y: yellow
G: green
W: white
A: blue
B: black *
A3CJ-90A1-14@
A3CJ-90A1-28@A3CJ-90B1-28@
Non-lighted A3CJ-90A0-@A3CJ-90B0-@A3CJ-90E0-@
Square
(A3CA)
LED lamp
A3CA-90A1-05E@A3CA-90B1-05E@A3CA-90E1-05E@R: red
Y: yellow
G: green
W: white
A3CA-90A1-12E@A3CA-90B1-12E@A3CA-90E1-12E@
A3CA-90A1-24E@A3CA-90B1-24E@A3CA-90E1-24E@
Incandescent
lamp
A3CA-90A1-06@
--- ---
R: red
Y: yellow
G: green
W: white
A: blue
B: black *
A3CA-90A1-14@
A3CA-90A1-28@A3CA-90B1-28@
Non-lighted A3CA-90A0-@A3CA-90B0-@A3CA-90E0-@
Round
(A3CT)
LED lamp
A3CT-90A1-05E@A3CT-90B1-05E@A3CT-90E1-05E@R: red
Y: yellow
G: green
W: white
A3CT-90A1-12E@A3CT-90B1-12E@A3CT-90E1-12E@
A3CT-90A1-24E@A3CT-90B1-24E@A3CT-90E1-24E@
Incandescent
lamp
A3CT-90A1-06@
--- ---
R: red
Y: yellow
G: green
W: white
A: blue
B: black *
A3CT-90A1-14@
A3CT-90A1-28@A3CT-90B1-28@
Non-lighted A3CT-90A0-@A3CT-90B0-@A3CT-90E0-@
Rectangular
Models
A3CJ
Square
Models
A3CA
Round
Models
A3CT
Individual models: Refer to pages 5 to 6.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■
Specifications: Refer to page 8.
■
Dimensions: Refer to page 10.
■Accessories: Refer to page 7.

A3C
4
Ordering Information
Illumination-only and Colored-illumination LED Models
"Illumination only" describes LED models for which the screen color is the same whether the LED is lit or not.
Example: Red LED
"Colored illumination" describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp
when the LED is lit.
Example: Red LED
Ordering: With colored-illumination models, order the Pushbutton, Lamp, and Switch as shown in the following table.
Illuminated color Pushbutton Lamp (LED) Switch
Red IP40
A3C@-500W
Enter one of the following sym-
bols in @.
J: Rectangular
A: Square
T: Round
A16-@DR
Enter one of the
following symbols in @.
5: 5 VDC
12: 12 VDC
24: 24 VDC
Refer to page 6. Make the se-
lection according to the
shape of the Pushbutton.
Yellow A16-@DY
Green A16-@DG
Cap (red)
Legend plate (milky white)
Reflective plunger
LED lamp (red) - - - Lamp
Pushbutton
Not lit
Red
Lit
Red
White cap (semi-transparent)
Legend plate (milky white)
Reflective plunger
LED lamp (red) - - - Lamp
Pushbutton
Not lit
White
Lit
Red

A3C
5
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Ordering: Specify a model number from the following page.
LED Lamp
Operation Unit
Lamps
LED Lamp Incandescent Lamp
Switch
Non-lighted Models
Operation Unit
Switch
Ordering set combinations: Refer to page 3. ■
Specifications: Refer to page 8.
■
Dimensions: Refer to page 10.
■Accessories: Refer to page 7.

A3C
6
Ordering Information
Ordering Individually................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbuttons
LED Lamp
Note: The red, yellow, and white Pushbuttons listed above can be used with
either LED lamp-lighted models or incandescent lamp-lighted models.
Incandescent Lamp
Non-lighted Models
Note: Models other than black can also be used with incandescent lamps.
Lamps
LED Lamp
Switches
Shape
Button color
Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500GY A3CA-500GY A3CT-500GY
White A3CJ-500W A3CA-500W A3CT-500W
Shape
Button color
Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500G A3CA-500G A3CT-500G
White A3CJ-500W A3CA-500W A3CT-500W
Blue A3CJ-500A A3CA-500A A3CT-500A
Shape
Button color
Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500G A3CA-500G A3CT-500G
White A3CJ-500W A3CA-500W A3CT-500W
Blue A3CJ-500A A3CA-500A A3CT-500A
Black A3CJ-501B A3CA-501B A3CT-501B
Color
Rated voltage Red Yellow Green White
5 VDC A16-5DR A16-5DY A16-5DG A16-5DW
12 VDC A16-12DR A16-12DY A16-12DG A16-12DW
24 VDC A16-24DR A16-24DY A16-24DG A16-24DW
Sealing Degree of protection: IP40
Shape
Rectangular Square Round
Contact type Switch action Terminal
Standard load
SPST-NO+
SPST NC
Momentary Solder A3CJ-7011 A3CA-7011 A3CT-7011
Alternate A3CJ-7021 A3CA-7021 A3CT-7021
Microload Momentary Solder A3CJ-7111 A3CA-7111 A3CT-7111
Alternate A3CJ-7121 A3CA-7121 A3CT-7121
Incandescent Lamp
Rated voltage Model
6 VAC/DC A16-5
14 VAC/DC A16-12
28 VAC/DC A16-24
Ordering set combinations: Refer to page 3. ■
Specifications: Refer to page 8.
■
Dimensions: Refer to page 10.
■Accessories: Refer to page 7.

A3C
7
Ordering Information
Accessories, Replacements, and Tools
Accessories
Tools
Replacements
Name Appearance Classification Model Remarks
Socket
Wire-wrap terminal A3C-4101
Cannot be used with Insulation Cover.
PCB terminal A3C-4102
Solder terminal A3C-4103
Insulation Cover --- A3C-3002 Cannot be used with Socket.
Switch Guard
For rectangular models A3CJ-5050
Cannot be used with Dust Cover.
For square, round models A3CA-5050
Dust Cover For rectangular models A3CJ-5060 Cannot be used with Switch Guard.
Can be used with Dust Cover attached.
Name Appearance Classification Model Remarks
Tightening Tool --- A3C-3004 The tightening torque is 0.20 to 0.39 N·m.
Extractor --- A3PJ-5080 ---
Name Appearance Classification Model Remarks
Legend Plate
For rectangular models A3CJ-5201
One Legend Plate (milk-white) is supplied per
standard Switch.
For square models A3CA-5201
For round models A3CT-5201
■Specifications: Refer to page 8. ■Dimensions: Refer to page 10.

A3C
8
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load: 0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load: 0.5 A at 250 VAC
Microload: 0.1 A at 250 VAC
Ratings
Note: The above ratings are for testing under the following conditions:
1) Load: Resistive load
2) Mounting conditions: No vibrations or shock
3) Temperature: 20°C ±2°C
4) Operation frequency: 20 operations/minute
* The minimum permissible load is 1 mA, 5 VDC.
LED Lamp
Incandescent Lamp
Characteristics
*1. With alternate-operation models, one operation cycle consists of set and
reset operations.
*2. The figure given above for the dielectric strength between lamp terminals is
for when there is no LED lamp or incandescent lamp mounted.
*3. No malfunction for more than 1s.
Operating Characteristics
* Alternate operation models only.
Contact Form
Model Item AC resistive load DC resistive load
Standard load 0.5 A at 250 VAC
1 A at 125 VAC 1 A at 30 VDC
Microload *0.1 A at 125 VAC 0.1 A at 30 VDC
Rated voltage Rated current Operating
voltage
Internal limiting
resistance
5 VDC 30 mA 5 VDC ± 5% 33 Ω
12 VDC 15 mA 12 VDC ± 5% 270 Ω
24 VDC 10 mA 24 VDC ± 5% 1,600 Ω
Rated voltage Rated current Operating voltage
6 VAC/DC 60 mA 5 VAC/DC
14 VAC/DC 40 mA 12 VAC/DC
28 VAC/DC 24 mA 24 VAC/DC
Operat-
ing fre-
quency
Mechanical
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max. *1
Electrical 20 operations/minute max.
Contact
Resis-
tance
Standard load 50mΩmax.
Microload 100mΩmax.
Insulation resistance 100 MΩmin. (at 500 VDC)
Dielectric
strength
Between terminals
of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between terminals
of different polarity
2,000 VAC, 50/60 Hz for 1 min
Between each
terminal and ground
2,000 VAC, 50/60 Hz for 1 min
Between lamp
terminals 1,000 VAC, 50/60 Hz for 1 min *2
Vibration
resis-
tance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *3
Shock
resis-
tance
Destruction 500 m/s2
Malfunction 150 m/s2*3
Durability
Mechanical
Momentary-operation models: 1,000,000 operations min.
Alternate-operation models: 100,000 operations min. *1
Electrical 100,000 operations min.
Weight Approx. 5 g <The weight indicated here applies
to the lighted models (SPST-NO+SPST-NC).>
Ambient operating temperature
−
10
°C
to +55
°C
(with no icing or condensation)
Ambient operating humidity
35% to 85%RH
Ambient storage temperature
−
25
°C
to +65
°C
(with no icing or condensation)
Degree of protection IP40
Electric shock protection class
Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC60947-5-1)
Operating force OF max. 2.45 N {250 gf}
Releasing force RF min. 0.29 N {30 gf}
Total travel TT Approx. 3.5 mm
Lock travel alternate LTA min. *0.5 mm
Pretravel PT max. 2.5 mm
Contact name Contact form
SPDT
NONO
NCNC

A3C
9
Nomenclature
Model Structure
Display Unit Structure
Type Specifications
(1)
Shape of Pushbutton
Rectangular
Square Round
(A3CJ) (A3CA) (A3CT) ------
(2)
LED lamp-lighted Models:
Red, Yellow, Green, White
Incandescent lamp-lighted Models:
Red, Yellow, Green, White, Blue
Non-lighted Models:
Red, Yellow, Green, White, Blue, Black
------
(3)
LED Lamp
Incandescent Lamp
(4)
Standard load
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Minimum applicable load: 1 mA at 5 VDC
Note: The A3CJ model is shown here as a re
p
resentative exam
p
le.
Pushbutton
Switch
Lamp
(2) Color of Pushbutton
(1) Shape of Pushbutton
(4) Switch Specifications
(3) Type of Lamp
Color cap
Legend Plate
Reflective
plunger

A3C
10
Dimensions (Unit: mm)
Terminal Connections
Panel Cutout (Top View)
•If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
Rectangular Models/A3CJ Square Models/A3CA Round Models/A3CT
Terminal
SPST-NO + SPST-NC Lighted and non-lighted models
Solder terminal
Accessories used Rectangular/A3CJ Square/A3CA, Round/A3CT
Switch only
Note: Recommended panel thickness: 1.0 to 3.2 mm. Note: Recommended panel thickness: 1.0 to 3.2 mm.
With Switch Guard
With Dust Cover ----------
0.6
M12 ×1
20
1
6
9.5
9.5
26.5
15.7
11.8
18
14
0.6
M12 ×1
20
9.5
9.5
6
26.5
11.8
11.8
14
14
0.6
M12 ×1
20
9.5
9.5
6
26.5
11.8 dia.14 dia.
0.6
t0.4
6.5
1.6 Lamp terminal
t0.3 NO
NO
NC
L+
L- NC
2
0.8
0.8
Terminal hole
Terminal Arrangement
(BOTTOM VIEW)
19 min. 7.5±0.1 2 dia. (Lock hole)
5.5±0.1
15 min.
12 dia.+0.2
0
12 dia.+0.2
0
15 min.
22.5 min. 7.5±0.1 2 dia.
5.5±0.1
19 min.
12 dia.
+0.2
0 19 min.
19 min.
12 dia.
+0.2
0
23.5 min. 7.5±0.1 2 dia.
5.5±0.1
19.5 min.
12 dia.+0.2
0

A3C
11
Dimensions (Unit: mm)
Accessory Mounting Dimensions
Dimensions with Socket Mounted
(The diagrams below show the external dimensions for rectangular models as representative models.)
Switch Guard
Wire-wrap Terminal/A3C-4101 PCB Terminal/A3C-4102 Solder Terminal/A3C-4103
Dust Cover
A3CJ-5060
Legend Plate
Note: 1. The thickness is 0.8 mm.
2. Since the Legend Plate is made of
polycarbonate, use alcohol-based paints
such as melanin, phthalic acid, or acrylic
paint when marking the legend.
Insulation Cover
A3C-3002
13.9 dia.
16.7
33.6 15.8
1
3.55
3.55
1
7
3.55
13.9 dia.
16.7
33.6 3.5
0.3
1.60.6
1
Six, 0.8 dia.
9.7
±
0.1
5.1
±
0.1 7.4
±
0.1
PCB Cutout
(BOTTOM VIEW)
16.7
33.6 5
3.2
3.2
0.3
7
1.6 13.9 dia.
4.7
2 0.5
0.8
Terminal Hole Dimensions
Guard (transparent)
Holder (black)
13.5 18
1
24.5
18
9
21.5
Torsion spring
Rectangular
A3CJ-5050
Guard (transparent)
Holder (black)
13.5 18
24.5
18
9
18
Torsion spring
Square/Round
A3CA-5050
Cover B (transparent)
Cover A (black)
13.8 18
24.5
1
22.5
18.5
9.6
10.1
10.1
10.1
10.1 dia.
0.8
14
Rectangular Square Round
13.9 dia.
18
33.6

A3C
12
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches.
Do not apply a voltage higher than the maximum
rated operating voltage between the lamp terminals,
as there is a risk that the incandescent lamp or LED
lamp will be damaged, and the Pushbutton will be
ejected.
When replacing the incandescent lamp, first turn OFF
the power supply, and then wait 10 minutes before
performing replacement, as the lamp is still hot
immediately after the power is turned OFF, so there
is a risk of burns.
Mounting
•To prevent electric shock or a fire, always make sure that the power
is turned OFF before mounting, removing, or wiring the Switch, or
performing maintenance.
•
Do not tighten the mounting ring excessively using pliers or a similar
tool. Excessive tightening may damage the mounting ring.
(Tightening torque: 0.20 to 0.39 N
·
m {20 gf to 40 gf})
Wiring
•When wiring, use wires of a size appropriate for the applied voltage
and carry current. Perform soldering correctly under the conditions
given below. Using the Switch with the wires soldered incorrectly
may cause the terminals to become abnormally hot and cause a
fire.
1. Soldering iron tip temperature: 350°C max. within 3 seconds.
2. Dip soldering: At 350°C within 3 seconds.
Wait for one minute after soldering before exerting any external
force on the solder.
•Use a non-corrosive rosin liquid for the flux.
•Perform wiring so that the wire sheaths do not come into contact
with the Switch. If this is unavoidable, use wires that can withstand
temperatures of 100°C min.
•After wiring to the Switch has been completed, ensure an
appropriate insulation distance.
Operating Environment
•Do not use in locations that are subject to dust, oil, or metal filings
as these may penetrate the interior of the Switch and cause
malfunction.
Using Microloads
•Using a standard load switch for opening and closing a microload
circuit may cause wear on the contacts. Use the switch within the
operating range. (Refer to the diagram below.) Even when using
microload models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may cause
the contact surface to become rough, and so decrease life
expectancy. Therefore, insert a contact protection circuit where
necessary. The minimum applicable load is the N-level reference
value. This value indicates the malfunction reference level for the
reliability level of 60% (λ60) (conforming to JIS C5003). The
equation, λ60 = 0.5 x 10−6/times indicates that the estimated
malfunction rate is less than 1/2,000,000 with a reliability level of
60%.
LED
•Resistance to limit the LED current is provided internally and so an
external resistance is not required.
CAUTION
Precautions for Correct Use
Rated voltage Internal limiting resistance
5 VDC 33 Ω
12 VDC 270 Ω
24 VDC 1,600 Ω
Microload
area
Standard
load area
Invalid
area
0.1 1 10 100 1,000
100mA 150mA
1mA
5
12
24
30
0.15mA 26mA 100mA
Current (mA)
0
Voltage (V)

A3C
13
Application
Mounting and Replacing the Pushbutton
(1) Mounting Direction for the Pushbutton/Display and Lamp
Lighted Pushbutton Switch
•Insert the Lamp (incandescent lamp or LED lamp) into the
Pushbutton so that the lamp guide fits into the wider gap between
the projections on the Pushbutton.
Indicator
•With Indicators, the Lamp is inserted facing the opposite direction
(i.e., at 180°) to that for Lighted Pushbutton Switches.
Note: Push the projections on the Lamp into the grooves on the Pushbutton/
Display.
The Lamp for Lighted Pushbutton Switches moves, but the Lamp for
Indicators is fixed.
(2) Mounting Direction for the Pushbutton/Display and Switch
•Insert the Pushbutton/Display into the Switch so that the lamp guide
is aligned with the non-projecting part of the Switch.
•Apply a pressure between 9.8 and 24.5 N.
Note: 1. The mounting direction for Indicators is 180°to that for Lighted
Pushbutton Switches. Be sure to insert the Legend Plate and other
parts with the correct orientation.
2. If the terminals of the Lamp become bent, it may be impossible to fit
them into the lamp terminal holes. Ensure that the terminals are
straight when they are inserted.
3. Take particular care about the mounting direction with the round
models (A3CT).
(3) Removing the Pushbutton/Display
Hold the recessed portions on the cap of the Pushbutton and pull.
Note: Do not use tools such as pliers to remove the Pushbutton as this may
damage the cap.
Panel Mounting
•Insert the Switch from the front of the panel. Mount the mounting
nut from the terminal end of the Switch and tighten it.
•There are projections on the terminal end of the Switch which may,
depending on the orientation, block the nut. In this case, turn the nut
until it is possible to mount it. Tighten the nut to a torque between
0.20 and 0.39 N·m.
•If soldering is used, mount the mounting nut first. Lead wires and
mounds of solder may make it impossible to mount the nut after
soldering.
Socket Mounting
•After securing the Switch to the panel using the mounting nut, insert
the Socket into the Switch.
•Align the positioning holes of the Socket with the projections of the
Switch before inserting the Socket.
Mounting the Insulation Cover
•After securing the Switch to the panel using the mounting nut, pass
the lead wires through the holes in the Insulation Cover and then
perform wiring. Hold the Insulation Cover so that the cylindrical hole
is facing the Switch, and insert the lead wires from the end with the
barriers.
•After wiring is completed, mount the Insulation Cover by pushing it
into the Switch.
Projections
LED/lamp guide
LED/lamp guide
Groove of the Display
Projection of the LED/lamp
LED/lamp guide
Projection
of the Switch
Recess
Mounting nut
Panel
Panel
Projection
of the Switch
Positioning
hole of the Socket
Insulation Cover attached to Switch
Switch terminal

A3C
14
Mounting the Dust Cover
1. The Dust Cover separates into 2 parts: the cap and the mounting
frame.
2. Insert the Switch into the mounting frame. (Align the lock
projection with the recess on the mounting frame.)
3. Insert the Switch in the state described in step 2 into the panel.
(Align the lock protrusion on the mounting frame with the hole in
the panel.)
4. Mount the mounting nut from the back of the panel and tighten it.
5. Insert the cap into the mounting frame. Ensure that the entire
perimeter of the cap is properly inserted into the mounting frame
by pressing down on the cap from different directions.
Mounting the Switch Guard
1. Insert the Switch into the Switch Guard.
2. Insert the Switch into the panel in the state described in step 1.
3. Mount the mounting nut from the back of the panel and tighten it.
Cap (transparent) Mounting frame Mounting nut
Panel
Lock protrusions
Switch
Mounting nut
Panel
Holder (black)
Guard (transparent)
•Application examplesprovided in thisdocument are for reference only. In actual applications, confirm equipment functionsand safety before using the product.
• Consult your OMRON representative before using the product under conditionswhich are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systemsor equipment that may have aserious
influence on livesand property if used improperly. Make sure that the ratingsand performance characteristicsof the product provide amargin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTSCOMPANY Contact: www.omron.com/ecb Cat. No. A030-E1-05
0812(0207)(O)
Note: Do not use thisdocument to operate the Unit.
This manual suits for next models
47
Table of contents
Other Omron Switch manuals

Omron
Omron A22LK Series User manual

Omron
Omron D4BL - User manual

Omron
Omron Sti D40A User manual

Omron
Omron D4SL-N N Series User manual

Omron
Omron TL4019 Series User manual

Omron
Omron SS Series User manual

Omron
Omron D4A-N - User manual

Omron
Omron D4BL - User manual

Omron
Omron D5C Series User manual

Omron
Omron 61F-GP-N User manual