Omron D4N Series User manual

G-219D4N
D4N
Miniature Safety Limit Switch
D4N
Safety Limit Switches
compatible to the Popular
D4D, Providing a Full
Lineup Conforming to In-
ternational Standards
• Lineup includes three contact models
with 2NC/1NO and 3NC in addition to
the 1NC/1NO, and 2NC contact mod-
els. Models with MBB contacts are
available too.
• M12-connector models are available,
saving on labor and simplifying mainte-
nance.
• Standardized gold-clad contacts pro-
vide high contact reliability.
Can be used with both standard loads
and microloads.
• Free of lead, cadmium, and hexavalent
chrome, reducing the burden on the
environment.
• Conforms to EN115 and EN81-1.
• Lineup includes both slow-action and
snap-action models with Zb contacts.
Be sure to read the Safety Precautions on
page G-237.
Note: Contact your sales representative for details on models with safety standard certification.
Model Number Structure
Model Number Legend
1. Conduit/Connector size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact-/-slow-action)
F: 2NC/1NO (MBB contact-/-slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top plunger
32: Top roller plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
1 2 3
D4N-@@@@
F502-EN2-04.book Seite 219 Dienstag, 26. Juli 2005 5:48 17

G-220 Safety Sensors / Components
Ordering Information
List of Models
Switches with Two Contacts
Actuator Conduit size Built-in switch mechanism
1NC/1NO (Snap-
action) 2NC
(Snap-action) 1NC/1NO (Slow-
action) 2NC
(Slow-action)
Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening Model
Roller lever (resin
lever, resin roller) 1-conduit Pg13.5 D4N-1120 D4N-1220 D4N-1A20 D4N-1B20
G1/2 D4N-2120 D4N-2220 D4N-2A20 D4N-2B20
1/2-14NPT D4N-3120 D4N-3220 D4N-3A20 D4N-3B20
M20 D4N-4120 D4N-4220 D4N-4A20 D4N-4B20
M12 connector D4N-9120 D4N-9220 D4N-9A20 D4N-9B20
2-conduit Pg13.5 D4N-5120 D4N-5220 D4N-5A20 D4N-5B20
G1/2 D4N-6120 D4N-6220 D4N-6A20 D4N-6B20
M20 D4N-8120 D4N-8220 D4N-8A20 D4N-8B20
Roller lever(metal
lever, resin roller) 1-conduit Pg13.5 D4N-1122 D4N-1222 D4N-1A22 D4N-1B22
G1/2 D4N-2122 D4N-2222 D4N-2A22 D4N-2B22
1/2-14NPT D4N-3122 D4N-3222 D4N-3A22 D4N-3B22
M20 D4N-4122 D4N-4222 D4N-4A22 D4N-4B22
M12 connector D4N-9122 D4N-9222 D4N-9A22 D4N-9B22
2-conduit Pg13.5 D4N-5122 D4N-5222 D4N-5A22 D4N-5B22
G1/2 D4N-6122 D4N-6222 D4N-6A22 D4N-6B22
M20 D4N-8122 D4N-8222 D4N-8A22 D4N-8B22
Roller lever(metal
lever, metal roller) 1-conduit Pg13.5 D4N-1125 D4N-1225 D4N-1A25 D4N-1B25
G1/2 D4N-2125 D4N-2225 D4N-2A25 D4N-2B25
1/2-14NPT D4N-3125 D4N-3225 D4N-3A25 D4N-3B25
M20 D4N-4125 D4N-4225 D4N-4A25 D4N-4B25
M12 connector D4N-9125 D4N-9225 D4N-9A25 D4N-9B25
Roller lever(metal
lever, bearing roll-
er)
1-conduit Pg13.5 D4N-1126 D4N-1226 D4N-1A26 D4N-1B26
G1/2 D4N-2126 D4N-2226 D4N-2A26 D4N-2B26
1/2-14NPT D4N-3126 D4N-3226 D4N-3A26 D4N-3B26
M20 D4N-4126 D4N-4226 D4N-4A26 D4N-4B26
M12 connector D4N-9126 D4N-9226 D4N-9A26 D4N-9B26
Plunger 1-conduit Pg13.5 D4N-1131 D4N-1231 D4N-1A31 D4N-1B31
G1/2 D4N-2131 D4N-2231 D4N-2A31 D4N-2B31
1/2-14NPT D4N-3131 D4N-3231 D4N-3A31 D4N-3B31
M20 D4N-4131 D4N-4231 D4N-4A31 D4N-4B31
M12 connector D4N-9131 D4N-9231 D4N-9A31 D4N-9B31
2-conduit Pg13.5 D4N-5131 D4N-5231 D4N-5A31 D4N-5B31
G1/2 D4N-6131 D4N-6231 D4N-6A31 D4N-6B31
M20 D4N-8131 D4N-8231 D4N-8A31 D4N-8B31
Roller plunger 1-conduit Pg13.5 D4N-1132 D4N-1232 D4N-1A32 D4N-1B32
G1/2 D4N-2132 D4N-2232 D4N-2A32 D4N-2B32
1/2-14NPT D4N-3132 D4N-3232 D4N-3A32 D4N-3B32
M20 D4N-4132 D4N-4232 D4N-4A32 D4N-4B32
M12 connector D4N-9132 D4N-9232 D4N-9A32 D4N-9B32
2-conduit Pg13.5 D4N-5132 D4N-5232 D4N-5A32 D4N-5B32
G1/2 D4N-6132 D4N-6232 D4N-6A32 D4N-6B32
M20 D4N-8132 D4N-8232 D4N-8A32 D4N-8B32
One-way roller
arm lever (hori-
zontal)
1-conduit Pg13.5 D4N-1162 D4N-1262 D4N-1A62 D4N-1B62
G1/2 D4N-2162 D4N-2262 D4N-2A62 D4N-2B62
1/2-14NPT D4N-3162 D4N-3262 D4N-3A62 D4N-3B62
M20 D4N-4162 D4N-4262 D4N-4A62 D4N-4B62
M12 connector D4N-9162 D4N-9262 D4N-9A62 D4N-9B62
2-conduit Pg13.5 D4N-5162 D4N-5262 D4N-5A62 D4N-5B62
G1/2 D4N-6162 D4N-6262 D4N-6A62 D4N-6B62
M20 D4N-8162 D4N-8262 D4N-8A62 D4N-8B62
Prefered types
F502-EN2-04.book Seite 220 Dienstag, 26. Juli 2005 5:48 17

G-221D4N
D4N
Note: It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
Switches with Three Contacts and MBB Contacts
One-way roller
arm lever (verti-
cal)
1-conduit Pg13.5 D4N-1172 D4N-1272 D4N-1A72 D4N-1B72
G1/2 D4N-2172 D4N-2272 D4N-2A72 D4N-2B72
1/2-14NPT D4N-3172 D4N-3272 D4N-3A72 D4N-3B72
M20 D4N-4172 D4N-4272 D4N-4A72 D4N-4B72
M12 connector D4N-9172 D4N-9272 D4N-9A72 D4N-9B72
2-conduit Pg13.5 D4N-5172 D4N-5272 D4N-5A72 D4N-5B72
G1/2 D4N-6172 D4N-6272 D4N-6A72 D4N-6B72
M20 D4N-8172 D4N-8272 D4N-8A72 D4N-8B72
Adjustable roller
lever, form lock
(metal lever, resin
roller)
1-conduit Pg13.5 D4N-112G D4N-122G D4N-1A2G D4N-1B2G
G1/2 D4N-212G D4N-222G D4N-2A2G D4N-2B2G
1/2-14NPT D4N-312G D4N-322G D4N-3A2G D4N-3B2G
M20 D4N-412G D4N-422G D4N-4A2G D4N-4B2G
M12 connector D4N-912G D4N-922G D4N-9A2G D4N-9B2G
2-conduit G1/2 D4N-612G D4N-622G D4N-6A2G D4N-6B2G
M20 D4N-812G D4N-822G D4N-8A2G D4N-8B2G
Adjustable roller
lever, form lock
(metal lever, rub-
ber roller)
1-conduit Pg13.5 D4N-112H D4N-122H D4N-1A2H D4N-1B2H
G1/2 D4N-212H D4N-222H D4N-2A2H D4N-2B2H
1/2-14NPT D4N-312H D4N-322H D4N-3A2H D4N-3B2H
M20 D4N-412H D4N-422H D4N-4A2H D4N-4B2H
M12 connector D4N-912H D4N-922H D4N-9A2H D4N-9B2H
2-conduit G1/2 D4N-612H D4N-622H D4N-6A2H D4N-6B2H
M20 D4N-812H D4N-822H D4N-8A2H D4N-8B2H
Actuator Conduit size Built-in switch mechanism
2NC/1NO (Snap-
action) 3NC
(Snap-action) 1NC/1NO MBB
(Slow-action) 2NC/1NO MBB
(Slow-action)
Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening Model
Roller lever (resin
lever, resin roller) 1-conduit Pg13.5 D4N-1C20 D4N-1D20 D4N-1E20 D4N-1F20
G1/2 D4N-2C20 D4N-2D20 D4N-2E20 D4N-2F20
1/2-14NPT D4N-3C20 D4N-3D20 D4N-3E20 D4N-3F20
M20 D4N-4C20 D4N-4D20 D4N-4E20 D4N-4F20
M12 connector --- --- D4N-9E20 ---
2-conduit Pg13.5 D4N-5C20 D4N-5D20 D4N-5E20 D4N-5F20
G1/2 D4N-6C20 D4N-6D20 D4N-6E20 D4N-6F20
M20 D4N-8C20 D4N-8D20 D4N-8E20 D4N-8F20
Rollerlever(metal
lever, resin roller) 1-conduit Pg13.5 D4N-1C22 D4N-1D22 D4N-1E22 D4N-1F22
G1/2 D4N-2C22 D4N-2D22 D4N-2E22 D4N-2F22
1/2-14NPT D4N-3C22 D4N-3D22 D4N-3E22 D4N-3F22
M20 D4N-4C22 D4N-4D22 D4N-4E22 D4N-4F22
M12 connector --- --- D4N-9E22 ---
2-conduit Pg13.5 D4N-5C22 D4N-5D22 D4N-5E22 D4N-5F22
G1/2 D4N-6C22 D4N-6D22 D4N-6E22 D4N-6F22
M20 D4N-8C22 D4N-8D22 D4N-8E22 D4N-8F22
Rollerlever(metal
lever, metal roller) 1-conduit Pg13.5 D4N-1C25 D4N-1D25 D4N-1E25 D4N-1F25
G1/2 D4N-2C25 D4N-2D25 D4N-2E25 D4N-2F25
1/2-14NPT D4N-3C25 D4N-3D25 D4N-3E25 D4N-3F25
M20 D4N-4C25 D4N-4D25 D4N-4E25 D4N-4F25
M12 connector --- --- D4N-9E25 ---
Prefered types
Actuator Conduit size Built-in switch mechanism
1NC/1NO (Snap-
action) 2NC
(Snap-action) 1NC/1NO (Slow-
action) 2NC
(Slow-action)
Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening Model
Prefered types
F502-EN2-04.book Seite 221 Dienstag, 26. Juli 2005 5:48 17

G-222 Safety Sensors / Components
Note: It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
Roller lever(metal
lever, bearing roll-
er)
1-conduit Pg13.5 D4N-1C26 D4N-1D26 D4N-1E26 D4N-1F26
G1/2 D4N-2C26 D4N-2D26 D4N-2E26 D4N-2F26
1/2-14NPT D4N-3C26 D4N-3D26 D4N-3E26 D4N-3F26
M20 D4N-4C26 D4N-4D26 D4N-4E26 D4N-4F26
M12 connector --- --- D4N-9E26 ---
Plunger 1-conduit Pg13.5 D4N-1C31 D4N-1D31 D4N-1E31 D4N-1F31
G1/2 D4N-2C31 D4N-2D31 D4N-2E31 D4N-2F31
1/2-14NPT D4N-3C31 D4N-3D31 D4N-3E31 D4N-3F31
M20 D4N-4C31 D4N-4D31 D4N-4E31 D4N-4F31
M12 connector --- --- D4N-9E31 ---
2-conduit Pg13.5 D4N-5C31 D4N-5D31 D4N-5E31 D4N-5F31
G1/2 D4N-6C31 D4N-6D31 D4N-6E31 D4N-6F31
M20 D4N-8C31 D4N-8D31 D4N-8E31 D4N-8F31
Roller plunger 1-conduit Pg13.5 D4N-1C32 D4N-1D32 D4N-1E32 D4N-1F32
G1/2 D4N-2C32 D4N-2D32 D4N-2E32 D4N-2F32
1/2-14NPT D4N-3C32 D4N-3D32 D4N-3E32 D4N-3F32
M20 D4N-4C32 D4N-4D32 D4N-4E32 D4N-4F32
M12 connector --- --- D4N-9E32 ---
2-conduit Pg13.5 D4N-5C32 D4N-5D32 D4N-5E32 D4N-5F32
G1/2 D4N-6C32 D4N-6D32 D4N-6E32 D4N-6F32
M20 D4N-8C32 D4N-8D32 D4N-8E32 D4N-8F32
One-way roller
arm lever (hori-
zontal)
1-conduit Pg13.5 D4N-1C62 D4N-1D62 D4N-1E62 D4N-1F62
G1/2 D4N-2C62 D4N-2D62 D4N-2E62 D4N-2F62
1/2-14NPT D4N-3C62 D4N-3D62 D4N-3E62 D4N-3F62
M20 D4N-4C62 D4N-4D62 D4N-4E62 D4N-4F62
M12 connector --- --- D4N-9E62 ----
2-conduit Pg13.5 D4N-5C62 D4N-5D62 D4N-5E62 D4N-5F62
G1/2 D4N-6C62 D4N-6D62 D4N-6E62 D4N-6F62
M20 D4N-8C62 D4N-8D62 D4N-8E62 D4N-8F62
One-way roller
arm lever (verti-
cal)
1-conduit Pg13.5 D4N-1C72 D4N-1D72 D4N-1E72 D4N-1F72
G1/2 D4N-2C72 D4N-2D72 D4N-2E72 D4N-2F72
1/2-14NPT D4N-3C72 D4N-3D72 D4N-3E72 D4N-3F72
M20 D4N-4C72 D4N-4D72 D4N-4E72 D4N-4F72
M12 connector --- --- D4N-9E72 ---
2-conduit Pg13.5 D4N-5C72 D4N-5D72 D4N-5E72 D4N-5F72
G1/2 D4N-6C72 D4N-6D72 D4N-6E72 D4N-6F72
M20 D4N-8C72 D4N-8D72 D4N-8E72 D4N-8F72
Adjustable roller
lever, form lock
(metal lever, resin
roller)
1-conduit Pg13.5 D4N-1C2G D4N-1D2G D4N-1E2G D4N-1F2G
G1/2 D4N-2C2G D4N-2D2G D4N-2E2G D4N-2F2G
1/2-14NPT D4N-3C2G D4N-3D2G D4N-3E2G D4N-3F2G
M20 D4N-4C2G D4N-4D2G D4N-4E2G D4N-4F2G
M12 connector --- --- D4N-9E2G ---
2-conduit G1/2 D4N-6C2G D4N-6D2G D4N-6E2G D4N-6F2G
M20 D4N-8C2G D4N-8D2G D4N-8E2G D4N-8F2G
Adjustable roller
lever, form lock
(metal lever, rub-
ber roller)
1-conduit Pg13.5 D4N-1C2H D4N-1D2H D4N-1E2H D4N-1F2H
G1/2 D4N-2C2H D4N-2D2H D4N-2E2H D4N-2F2H
1/2-14NPT D4N-3C2H D4N-3D2H D4N-3E2H D4N-3F2H
M20 D4N-4C2H D4N-4D2H D4N-4E2H D4N-4F2H
M12 connector --- --- D4N-9E2H ---
2-conduit G1/2 D4N-6C2H D4N-6D2H D4N-6E2H D4N-6F2H
M20 D4N-8C2H D4N-8D2H D4N-8E2H D4N-8F2H
Actuator Conduit size Built-in switch mechanism
2NC/1NO (Snap-
action) 3NC
(Snap-action) 1NC/1NO MBB
(Slow-action) 2NC/1NO MBB
(Slow-action)
Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening Model
Prefered types
F502-EN2-04.book Seite 222 Dienstag, 26. Juli 2005 5:48 17

G-223D4N
D4N
General-purpose Switches with Two Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Actuator Conduit size Built-in switch mechanism
1NC/1NO (Snap-
action) 2NC
(Snap-action) 1NC/1NO (Slow-
action) 2NC
(Slow-action)
Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening Model
Fork lever lock
(right operation) 1-conduit G1/2 --- --- --- --- --- D4N-2ARE --- D4N-2BRE
1/2-14NPT D4N-3ARE D4N-3BRE
M20 D4N-4ARE D4N-4BRE
2-conduit G1/2 --- --- --- D4N-6ARE --- D4N-6BRE
M20 D4N-8ARE D4N-8BRE
Fork lever lock
(left operation) 1-conduit G1/2 --- --- --- D4N-2ALE --- D4N-2BLE
1/2-14NPT D4N-3ALE D4N-3BLE
M20 D4N-4ALE D4N-4BLE
2-conduit G1/2 --- --- --- D4N-6ALE --- D4N-6BLE
M20 D4N-8ALE D4N-8BLE
Cat whisker 1-conduit G1/2 --- D4N-2180 --- D4N-2280 --- --- --- D4N-2B80
1/2-14NPT D4N-3180 D4N-3280 D4N-3B80
M20 D4N-4180 D4N-4280 D4N-4B80
2-conduit G1/2 --- D4N-6180 --- D4N-6280 --- --- D4N-6B80
M20 D4N-8180 D4N-8280 D4N-8B80
Plastic rod 1-conduit G1/2 --- D4N-2187 --- D4N-2287 --- --- D4N-2B87
1/2-14NPT D4N-3187 D4N-3287 D4N-3B87
M20 D4N-4187 D4N-4287 D4N-4B87
2-conduit G1/2 --- D4N-6187 --- D4N-6287 --- --- D4N-6B87
M20 D4N-8187 D4N-8287 D4N-8B87
Prefered types
WARNING
@
Do not use general purpose switch models for applications that
require form lock for safety reasons
F502-EN2-04.book Seite 223 Dienstag, 26. Juli 2005 5:48 17

G-224 Safety Sensors / Components
General-purpose Switches with Three Contacts and MBB Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Specifications
Standards and EC Directives
•Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088 (slow-action models only)
GS-ET-15
Approved Standards
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
CCC (China Compulsory Certification) Mark
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Actuator Conduit size Built-in switch mechanism
Direct
opening 2NC/1NO
(Slow-action) Direct
opening 3NC
(Slow-action) Direct
opening 1NC/1NO
MBB
(Slow-action)
Direct
opening 2NC/1NO
MBB
(Slow-action)
Fork lever lock
(right operation) 1-conduit G1/2 --- D4N-2CRE --- D4N-2DRE --- D4N-2ERE --- D4N-2FRE
1/2-14NPT D4N-3CRE D4N-3DRE D4N-3ERE D4N-3FRE
M20 D4N-4CRE D4N-4DRE D4N-4ERE D4N-4FRE
2-conduit G1/2 --- D4N-6CRE --- D4N-6DRE --- D4N-6ERE --- D4N-6FRE
M20 D4N-8CRE D4N-8DRE D4N-8ERE D4N-8FRE
Fork lever lock
(left operation) 1-conduit G1/2 --- D4N-2CLE --- D4N-2DLE --- D4N-2ELE --- D4N-2FLE
1/2-14NPT D4N-3CLE D4N-3DLE D4N-3ELE D4N-3FLE
M20 D4N-4CLE D4N-4DLE D4N-4ELE D4N-4FLE
2-conduit G1/2 --- D4N-6CLE --- D4N-6DLE --- D4N-6ELE --- D4N-6FLE
M20 D4N-8CLE D4N-8DLE D4N-8ELE D4N-8FLE
Cat whisker 1-conduit G1/2 --- --- --- D4N-2D80 --- --- --- ---
1/2-14NPT D4N-3D80
M20 D4N-4D80
2-conduit G1/2 --- --- D4N-6D80 --- ---
M20 D4N-8D80
Plastic rod 1-conduit G1/2 --- --- D4N-2D87 --- ---
1/2-14NPT D4N-3D87
M20 D4N-4D87
2-conduit G1/2 --- --- D4N-6D87 --- ---
M20 D4N-8D87
Agency Standard File No.
TÜV Product
Service EN60947-5-1 (approved
direct opening) B03 11 39656
061
UL (See note.) UL508, CSA C22.2 No.14 E76675
Agency Standard File No.
CQC GB14048.5 Under applica-
tion
Item Utilization
category AC-15 DC-13
Rated operating current (Ie)3 A 0.27 A
Rated operating voltage (Ue)240 V 250 V
Rated
voltage Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
Rated
voltage Carry current Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A
WARNING
@
Do not use general purpose switch models for applications that
require form lock for safety reasons
F502-EN2-04.book Seite 224 Dienstag, 26. Juli 2005 5:48 17

G-225D4N
D4N
Characteristics
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4N in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise,
premature wear, Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. If the ambient temperature is greater than 35°C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
7. The mechanical durability of fork lever lock models is 10,000,000 operations min.
Degree of protection (See note 3.) IP67 (EN60947-5-1)
Durability
(See note 4.) Mechanical 15,000,000 operations min. (See note 7.)
Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Operating speed 1 mm/s to 0.5 m/s (D4-1120)
Operating frequency 30 operations/minute max.
Contact resistance 25 mΩmax.
Minimum applicable load (See note 6.) Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)300 V
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) Level 3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity: 2.5 kV
Between terminals of different polarities: 4 kV
Between other terminals and uncharged metallic parts : 6 kV
Insulation resistance 100 MΩmin.
Contact gap Snap-action: 2 x 0.5 mm min
Slow-action: 2 x 2 mm min
Vibration resistance Malfunction 10 to 55 Hz, 0.75-mm single amplitude
Shock resistance Destruction 1,000 m/s2min.
Malfunction 300 m/s2min.
Conditional short-circuit current 100 A (EN60947-5-1)
Rated open thermal current (Ith)10 A (EN60947-5-1)
Ambient temperature Operating: −30°C to 70°C with no icing
Ambient humidity Operating: 95% max.
Weight Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-5120)
F502-EN2-04.book Seite 225 Dienstag, 26. Juli 2005 5:48 17

G-226 Safety Sensors / Components
Structure, Names, and Functions
Structure
Direct Opening Mechanism
1NC/1NO Contact (Slow-action)
2NC Contact (Slow-action)
Pg13.5
G1/2
1/2-14NPT
M20
M12 connector
Note: M12 connector types are not available for
Switches with three contacts.
Head
The direction of the switch head can be varied to any of
the four directions. (Roller plunger models can be
mounted in either of two directions at a 90˚ angle.)
Conduit Opening
A wide variety of conduits is available.
Built-in Switch
The built-in switch has a direct opening mechanism
that forcibly separates the NC contact even when
there is contact deposit.
Safety-oriented Lever Setting
(Form-lock construction)
Grooves which engage the lever are cut in the lever and
rotary shaft to prevent the lever from slipping against the
rotary shaft.
There are resin-lever and metal-lever types.
Cover
The cover, with a hinge on its lower part, can
be opened by removing the screw of the
cover, which ensures ease of maintenance
and wiring.
Size 1-conduit 2-conduit
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
---
Contact spring
Return spring
Fixed contact (NC)
Fixed contact (NO)
Plunger
Movable contact
Conforms to EN60947-5-1 Direct Opening Operation
(Only the NC contact side has a direct opening
mechanism.)
When metal deposition occurs, the contacts are
separated from each other by the plunger being
pushed in.
Contact spring
Fixed contact (NC)
Plunger
Movable contact
Return spring
Conforms to EN60947-5-1 Direct Opening Operation
(Both NC contacts have a direct opening
mechanism.)
F502-EN2-04.book Seite 226 Dienstag, 26. Juli 2005 5:48 17

G-227D4N
D4N
Contact Form
Note: 1. Terminals are numbered according to EN50013 and the contact forms are according to IEC947-5-1.
2. MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally
open contact (NO) closes.
Model Contact Contact form Operating pattern Remarks
D4N-@1@1NC/1NO (Snap-ac-
tion)
D4N-@2@2NC (Snap-action)
D4N-@A@1NC/1NO (Slow-ac-
tion)
D4N-@B@2NC (Slow-action)
D4N-@C@2NC/1NO (Slow-ac-
tion)
D4N-@D@3NC (Slow-action)
D4N-@E@1NC/1NO MBB
(Slow-action)
D4N-@F@2NC/1NO MBB
(Slow-action)
14
32
13
31
Zb
ON
Stroke
13-14
31-32
Only NC contacts 31-32 have an
approved direct opening
mechanism.
The terminals 13-14 and 31-32
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have an approved
direct opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have an
approved direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have an approved
direct opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
21-22
33-34
11-12
Only NC contacts 11-12 and
21-22 have an approved
direct opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
11
21
12
22
31 32
Zb
ON
Stroke
11-12
21-22
31-32
Only NC contacts 11-12, 21-22,
and 31-32 have an approved di-
rect opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have an
approved direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
11-12
21-22
33-34
Only NC contacts 11-12 and
21-22 have an approved direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
F502-EN2-04.book Seite 227 Dienstag, 26. Juli 2005 5:48 17

G-228 Safety Sensors / Components
Dimensions
Switches
Note: All units are in millimeters unless otherwise indicated.
1-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to page G-231 for details on M12 connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: 1. Variation occurs in the simultaneity of contact opening/closing oper-
ations of 2NC, 2NC/1NO, and 3NC contacts. Check contact opera-
tion.
2. Only for snap-action models.
3. Reference value.
4. Only for slow-action models. For safe use, always make sure
that the minimum values or greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Note: 1. These PT values are possible when the NC contacts are open
(OFF).
2. These PT values are possible when the NO contacts are closed
(ON).
3. Only for MBB models.
4. Reference values for MBB models only.
5. Reference values.
6. For safe use, always make sure that the minimum values or
greater are provided.
Roller Lever (Resin Lever, Resin Roller)
D4N-1@20 D4N-2@20
D4N-3@20 D4N-4@20
D4N-9@20 (See note 2.) 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
47±1
40±1
(27)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Resin lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Roller Lever (Metal Lever, Resin Roller)
D4N-1@22 D4N-2@22
D4N-3@22 D4N-4@22
D4N-9@22 (See note 2.)17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
45±1
39.5±1
(31)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Metal lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Roller Lever (Metal Lever, Metal Roller)
D4N-1@25 D4N-2@25
D4N-3@25 D4N-4@25
D4N-9@25 (See note 2.) 17.5 dia. ×7
sintered stainless
steel roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
45±1
39.5±1
(31)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Metal lever 20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
Roller Lever (Metal Lever, Bearing Roller)
D4N-1@26 D4N-2@26
D4N-3@26 D4N-4@26
D4N-9@26 (See note 2.) 17 dia. ×6
Bearing roller
Two, 4+0.15 dia. holes
Depth: 5
0
Metal lever 20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap 30
27.5
11±0.2
43.6±1
39±1
(31.5)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Model D4N-@120
D4N-@220
D4N-@B20
D4N-@D20
D4N-@122
D4N-@222
D4N-@B22
D4N-@D22
D4N-@125
D4N-@225
D4N-@B25
D4N-@D25
D4N-@126
D4N-@226
D4N-@B26
D4N-@D26
OF max. 5.0 N
RF min. 0.5 N
PT 18°to 27°
OT min. 40°
MD max.
(See note 2.) 14°
OP ---
TT
(See note 3.) (80°)
DOT min.
(See note 4.) 50°
DOF min.
(See note 4.) 20 N
!
Model D4N-@A20
D4N-@C20
D4N-@E20
D4N-@F20
D4N-@A22
D4N-@C22
D4N-@E22
D4N-@F22
D4N-@A25
D4N-@C25
D4N-@E25
D4N-@F25
D4N-@A26
D4N-@C26
D4N-@E26
D4N-@F26
OF max. 5.0 N
RF min. 0.5 N
PT
(See note 1.) 18°to 27°
PT (2nd)
(See note 2.) (44°)
PT (See note 3.) 27.5°to 36.5°
PT (2nd)
(See note 4.) (18°)
OT min. 40°
OP ---
TT (See note 5.) (80°)
DOT min. (See note 6.) 50°
DOF min. (See note 6.) 20 N
!
F502-EN2-04.book Seite 228 Dienstag, 26. Juli 2005 5:48 17

G-229D4N
D4N
1-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to page G-231 for details on M12 connectors.
Plunger
D4N-1@31 D4N-2@31
D4N-3@31 D4N-4@31
D4N-9@31 (See note 2.)
Two, 3±0.05 dia.
holes
6-dia. resin
plunger
Two, 4
+0.15
dia. holes
Depth: 5
0
30
(31.5)
21.5
25
±0.1
11
±0.2
22
±0.2
31 max.
55 47
±0.2
2.5
9
±0.2
OP
20
±0.1
22
±0.1
14.2
12 dia.
2.15±0.05R
mounting holes
Conduit cap
Roller Plunger
D4N-1@32 D4N-2@32
D4N-3@32 D4N-4@32
D4N-9@32 (See note 2.)
9.5 dia. ×5
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
25.2
11
±0.2
22
±0.2
31 max.
55 47
±0.2
2.5
9
±0.2
OP
20
±0.1
22
±0.1
14.2
(31.5)
21.5
20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
Two, 4
+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-1@62 D4N-2@62
D4N-3@62 D4N-4@62
D4N-9@62 (See note 2.)
Operating direction
12 dia. ×5
resin roller
30
14.8
23.3
13.5
19.5±0.2
11±0.2
11±0.2
20R 10.2
22±0.2
31 max.
47±0.2
2.5
9±0.2
OP
20±0.1
22±0.1
14.2
55
(31.5)
21.5
2.15±0.05R
mounting holes
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-1@72 D4N-2@72
D4N-3@72 D4N-4@72
D4N-9@72 (See note 2.)
Operating
direction
12 dia. ×5
resin roller
30
OP
14.7
R19
19.5
±0.2
11
±0.2
11
±0.2
12
10.2
22
±0.2
31 max.
47
±0.2
2.5
9
±0.2
20
±0.1
22
±0.1
14.2
(31.5)
55
21.5
2.15±0.05R
mounting holes
Conduit cap
F502-EN2-04.book Seite 229 Dienstag, 26. Juli 2005 5:48 17

G-230 Safety Sensors / Components
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. Only for snap-action models.
3. Reference value.
4. On ly for sl ow-a ct ion m od els. For s afe us e, always
make sure that the minimum values or greater are
provided.
Slow-action (1NC/1NO) (2NC/1NO)
Note: 1. These PT values are possible when the NC contacts are
open (OFF).
2. These PT values are possible when the NO contacts are
closed (ON).
3. Only for MBB models.
4. Reference values for MBB models.
5. Only for MBB models.
6. Reference value.
7. For safe use, always make sure that the minimum
values or greater are provided.
Model D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-@132
D4N-@232
D4N-@B32
D4N-@D32
D4N-@162
D4N-@262
D4N-@B62
D4N-@D62
D4N-@172
D4N-@272
D4N-@B72
D4N-@D72
OF max. 6.5 N 6.5 N 5.0 N 5.0 N
RF min. 1.5 N 1.5 N 0.8 N 0.8 N
PT max. 2 mm 2 mm 4 mm 4 mm
OT min. 4 mm 4 mm 5 mm 5 mm
MD max.
(See note 2.) 1 mm 1 mm 1.5 mm 1.5 mm
OP 18.2
±0.5 mm 28.6
±0.8 mm 37 ±0.8 mm 27 ±0.8 mm
TT
(See note 3.) (6 mm) (6 mm) (9 mm) (9 mm)
DOT min.
(See note 4.) 3.2 mm 3.2 mm 5.8 mm 4.8 mm
DOF min.
(See note 4.) 20 N 20 N 20 N 20 N
!
Model D4N-@A31
D4N-@C31
D4N-@E31
D4N-@F31
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
D4N-@A62
D4N-@C62
D4N-@E62
D4N-@F62
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
OF max. 6.5 N 6.5 N 5.0 N 5.0 N
RF min. 1.5 N 1.5 N 0.8 N 0.8 N
PT max.
(See note 1.) 2 mm 2 mm 4 mm 4 mm
PT (2nd)
(See note 2.) (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm)
PT max.
(See note 3.) 2.8 mm 2.8 mm 4 mm 4 mm
PT (2nd)
(See note 4.) (1 mm) (1 mm) (1.5 mm) (1.5 mm)
OT min. 4 mm 4 mm 5 mm 5 mm
OP 18.2
±0.5 mm 28.6
±0.8 mm 37 ±0.8 mm 27 ±0.8 mm
OP
(See note 5.) 17.4
±0.5 mm 28 ±0.8 mm 36 ±0.8 mm 26.1
±0.8 mm
TT
(See note 6.) (6 mm) (6 mm) (9 mm) (9 mm)
DOT min.
(See note 7.) 3.2 mm 3.2 mm 5.8 mm 4.8 mm
DOF min.
(See note 7.) 20 N 20 N 20 N 20 N
!
F502-EN2-04.book Seite 230 Dienstag, 26. Juli 2005 5:48 17

G-231D4N
D4N
1-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to following diagrams for details on M12 connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. The operating characteristics of these Switches were mea-
sured with the roller lever set at 32 mm.
3. Only for snap-action models.
4. Reference value.
5. Only for slow-action models. For safe use, always make
sure that the minimum values or greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Note: 1. The operating characteristics of these Switches were mea-
sured with the roller lever set at 32 mm.
2. This PT value is possible when the NC contacts are open
(OFF).
3. This PT value is possible when the NO contacts are closed
(ON).
4. Only for MBB models.
5. Reference value for MBB models only.
6. Reference value.
7. For safe use, always make sure that the minimum
values or greater are provided.
1-conduit M12 Connector
D4N-9@@@
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-1@2G D4N-2@2G
D4N-3@2G D4N-4@2G
D4N-9@2G (See note 2.) 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
30
27.5
11±0.2
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
20 to 66R
18
20±0.1
22±0.1
14.2
45±1
39.5±1
(31)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-1@2H D4N-2@2H
D4N-3@2H D4N-4@2H
D4N-9@2H (See note 2.)
50 dia. ×8
rubber roller
Bearing
Stainless steel
lever
Two, 4
+0.15
dia. holes
Depth: 5
0
20.5×20.5
30
27.5
11
±0.2
21.5
22
±0.2
31 max.
55 47
±0.2
2.5
9
±0.2
18
20
±0.1
22
±0.1
14.2
48.2
±1
41.3
±1
(29.2)
32 to 66R
2.15±0.05R
mounting holes
Conduit cap
Model D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
(See note 2.)
OF max. 4.5 N
RF min. 0.4 N
PT 18°to 27°
OT min. 40°
MD max. (See note 3.) 14°
OP ---
TT (See note 4.) (80°)
DOT min. (See note 5.) 50°
DOF min. (See note 5.) 20 N
Model D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
(See note 1.)
OF max. 4.5 N
RF min. 0.4 N
PT (See note 2.) 18°to 27°
PT (2nd) (See note 3.) (44°)
PT (See note 4.) 27.5°to 36.5°
PT (2nd) (See note 5.) (18°)
OT min. 40°
OP ---
TT (See note 6.) (80°)
DOT min. 50°
DOF min. (See note 7.) 20 N
(14)
M12 ×1
14.2
30
!
!
F502-EN2-04.book Seite 231 Dienstag, 26. Juli 2005 5:48 17

G-232 Safety Sensors / Components
1-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Use the dog within 35 mm of the tip of the actuator and keep the total travel to 70 mm or less.
Slow-action (1NC/1NO) (2NC/1NO) (2NC) (3NC)
Note: Variation occurs in the simultaneity of contact opening/closing operations
of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
20.5 ×20.5
Two, 4
+0.15
dia. holes
Depth: 5
0
Fork Lever Lock
(Right Operation)
D4N-1@RE D4N-2@RE
D4N-3@RE D4N-4@RE
2.15±0.05R
mounting
holes
30
27.5
11±
0.2
47 max.
39.3±
1
(27.2)
21.5
22±
0.2
31 max.
55 47±
0.2
2.5
9±
0.2
26R
90°
18
20±
0.1
22±
0.1
14.2
Two, 17.5 dia.
× 8 rubber
rollers
Conduit cap
Two, 4
+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Left Operation)
D4N-1@LE D4N-2@LE
D4N-3@LE D4N-4@LE
2.15±0.05R
mounting holes
Two, 17.5 dia. ×
8 rubber rollers
30
27.5
11±
0.2
39.3±
1
(27.2)
21.5
22±
0.2
31 max.
55
47±
0.2
2.5
9±
0.2
R26 90°
18
20±
0.1
22±
0.1
14.2
47 max.
20.5 ×20.5
Conduit cap
Two, 4
+0.15
dia. holes
Depth: 5
0
Cat Whisker
D4N-1@80 D4N-2@80
D4N-3@80 D4N-4@80
1.2-dia.
stainless
steel wire
(See note
2.)
2.15±0.05R
mounting holes
30
(31.5)
11±0.2
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
(50.1)
PT
143.1
20±0.1
22±0.1
14.2
20.5 ×20.5
Sealing cap
16.6 dia.
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Plastic Rod
D4N-1@87 D4N-2@87
D4N-3@87 D4N-4@87
2.15±0.05R
mounting holes
30
(31.5)
11
±0.2
22
±0.2
31 max.
55
115
38
42
12
±0.2
47
±0.2
2.5
PT
20
±0.1
22
±0.1
14.2
21.5
9
±0.2
Resin rod
(See note 2.)
20.5 ×
20.5
Sealing cap 16.6 dia.
Conduit cap
Model D4N-@@RE D4N-@@LE
Force necessary to reverse the
direction of the lever: max. 6.4 N 6.4 N
Movement until the lever revers-
es 55 ±10°55 ±10°
Movement until switch operation
(NC) 6.5°
(MBB: 10°)6.5°
(MBB: 10°)
Movement until switch operation
(NO) 18.5°
(MBB: 5°)18.5°
(MBB: 5°)
Model D4N-@@80 D4N-@@87
OF max. 1.5 N 1.5 N
PT max. 15°15°
F502-EN2-04.book Seite 232 Dienstag, 26. Juli 2005 5:48 17

G-233D4N
D4N
2-conduit Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: 1. Variation occurs in the simultaneity of contact opening/closing oper-
ations of 2NC, 2NC/1NO, and 3NC contacts. Check contact opera-
tion.
2. Only for snap-action models.
3. Reference value.
4. Only for slow-action models. For safe use, always make sure
that the minimum values or greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Note: 1. This PT value is possible when the NC contacts are open (OFF).
2. This PT value is possible when the NO contacts are closed (ON).
3. Only for MBB models.
4. Reference value for MBB models.
5. Only for MBB models.
6. Reference value.
7. For safe use, always make sure that the minimum values or
greater are provided.
Roller Lever (Resin Lever, Resin Roller)
D4N-5@20
D4N-6@20
D4N-8@20
17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
27.5
20.5
20.5 ×20.5
11±0.2
47±1
40±1
(27)
21.5
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
5.4
9±0.2
26R
18
20±0.1
40±0.1
42
±0.1
22±0.1
14.2
Resin lever
2.15±0.05R
mounting
holes
Conduit cap
Roller Lever (Metal Lever, Resin Roller)
D4N-5@22
D4N-6@22
D4N-8@22 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
26R
45±1
39.5±1
(31)
39±0.2
Metal lever 20.5 ×20.5
2.15±0.05R
mounting
holes
Conduit cap
Plunger
D4N-5@31
D4N-6@31
D4N-8@31 Two, 3±0.05
dia. holes
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
20.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
OP
20±0.1
40±0.1
42±0.1
22±0.1
14.2
(31.5)
21.5
11±0.2
25±0.1
12 dia.
39±0.2
6-dia. resin plunger
2.15±0.05R
mounting
holes
Conduit cap
Roller Plunger
D4N-5@32
D4N-6@32
D4N-8@32 9.5 dia. ×5
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
20.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
OP 25.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
11±0.2
(31.5)
21.5
39±0.2
20.5 ×20.5
2.15±0.05R
mounting
holes
Conduit cap
Model D4N-@120
D4N-@220
D4N-@B20
D4N-@D20
D4N-@122
D4N-@222
D4N-@B22
D4N-@D22
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-@132
D4N-@232
D4N-@B32
D4N-@D32
OF max. 5 N 5 N 6.5 N 6.5 N
RF min. 0.5 N 0.5 N 1.5 N 1.5 N
PT 18°to 27°18°to 27°2 mm 2 mm
OT min. 40°40°4 mm 4 mm
MD max.
(See note 2.) 14°14°1 mm 1 mm
OP --- --- 18 ±0.5 mm 28.2 ±0.8 mm
TT
(See note 3.) (80°)(80°) (6 mm) (6 mm)
DOT min.
(See note 4.) 50°50°3.2 mm 3.2 mm
DOF min.
(See note 4.) 20 N 20 N 20 N 20 N
Model D4N-@A20
D4N-@C20
D4N-@E20
D4N-@F20
D4N-@A22
D4N-@C22
D4N-@E22
D4N-@F22
D4N-@A31
D4N-@C31
D4N-@E31
D4N-@F31
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
OF max. 5 N 5 N 6.5 N 6.5 N
RF min. 0.5 N 0.5 N 1.5 N 1.5 N
PT
(See note 1.) 18°to 27°18°to 27°2 mm 2 mm
PT (2nd)
(See note 2.) (44°)(44°) (2.9 mm) (2.9 mm)
PT
(See note 3.) 27.5°to 36.5°27.5°to 36.5°2.8 mm 2.8 mm
PT (2nd)
(See note 4.) (18°)(18°) (1 mm) (1 mm)
OT min. 40°40°4 mm 4 mm
OP --- --- 18 ±0.5 mm 28.2 ±0.8 mm
OP
(See note 5.) --- --- 17.4 ±0.5 mm 28 ±0.8 mm
TT
(See note 6.) (80°)(80°) (6 mm) (6 mm)
DOT min.
(See note 7.) 50°50°3.2 mm 3.2 mm
DOF min.
(See note 7.) 20 N 20 N 20 N 20 N
!
!
F502-EN2-04.book Seite 233 Dienstag, 26. Juli 2005 5:48 17

G-234 Safety Sensors / Components
2-conduit Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: 1. Variation occurs in the simultaneity of contact opening/closing operations of
2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
2. The operating characteristics of these Switches were measured with the roller
lever set at 30 mm.
3. The operating characteristics of these Switches were measured with the roller
lever set at 31 mm.
4. Only for snap-action models.
5. Reference value.
6. Only for slow-action models. For safe use, always make sure that the
minimum values or greater are provided.
Slow-action (1NC/1NO) (2NC/1NO)
Note: 1. The operating characteristics of these Switches were measured with the roller
lever set at 30 mm.
2. The operating characteristics of these Switches were measured with the roller
lever set at 31 mm.
3. This PT value is possible when the NC contacts are open (OFF).
4. This PT value is possible when the NO contacts are closed (ON).
5. Only for MBB models.
6. Reference value for MBB models only.
7. Only for MBB models.
8. Reference value.
9. For safe use, always make sure that the minimum values or greater are
provided.
Two, 4
+0.15
dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-5@62
D4N-6@62
D4N-8@62
12 dia. x 5
resin roller
2.15±0.05R
mounting holes
30
Cap
20.5
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
11±0.2
10.2
(31.5)
14.8
Operating direction
23.3
13.5
11±0.2
19.5±0.2
20R
OP
21.5
39±0.2
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-5@72
D4N-6@72
D4N-8@72
Operating
direction
12 dia. ×5
resin roller
30
Cap
20.5
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
OP
14.7
19R
19.5±0.2
11±0.2 12 11±0.2
10.2
(31.5)
21.5
39±0.2
2.15±0.05R
mounting
holes
Conduit cap
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-6@2G
D4N-8@2G
17.5 dia. ×6.8
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
45±1
39.5±1
(31)
39±0.2
20 to 66RResin lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-6@2H
D4N-8@2H
50 dia. ×8
rubber roller
Bearing
Stainless
steel lever
Two, 4+0.15 dia. holes
Depth: 5
0
20.5 ×20.5
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
48.2±1
41.3±1
(29.2)
39±0.2
32 to 66R
2.15±0.05R
mounting holes
Conduit cap
Model D4N-@162
D4N-@262
D4N-@B62
D4N-@D62
D4N-@172
D4N-@272
D4N-@B72
D4N-@D72
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
(See note 2.)
D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
(See note 3.)
OF max. 5.0 N 5.0 N 4.5 N 4.5 N
RF min. 0.8 N 0.8 N 0.4 N 0.4 N
PT max. 4 mm 4 mm 18°to 27°18°to 27°
OT min. 5 mm 5 mm 40°40°
MD max.
(See note 4.) 1.5 mm 1.5 mm 14°14°
OP 37 ±0.8 mm 27 ±0.8 mm --- ---
TT
(See note 5.) (9 mm) (9 mm) (70°)(70°)
DOT min.
(See note 6.) 5.8 mm 4.8 mm 50°50°
DOF min.
(See note 6.) 20 N 20 N 20 N 20 N
Model D4N-@A62
D4N-@C62
D4N-@E62
D4N-@F62
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
(See note 1.)
D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
(See note 2.)
OF max. 5.0 N 5.0 N 4.5 N 4.5 N
RF min. 0.8 N 0.8 N 0.4 N 0.4 N
PT max.
(See note 3.) 4 mm 4 mm 18°to 27°18°to 27°
PT (2nd)
(See note 4.) (5.2 mm) (4.3 mm) (44°)(44°)
PT max.
(See note 5.) 4 mm 4 mm 27.5°to 36.5°27.5°to 36.5°
PT (2nd)
(See note 6.) (1.5 mm) (1.5 mm) (18°)(18°)
OT min. 5 mm 5 mm 40°40°
OP 37 ±0.8 mm 27 ±0.8 mm --- ---
OP
(See note 7.) 36 ±0.8 mm 26.1 ±0.8 mm --- ---
TT
(See note 8.) (9 mm) (9 mm) (70°)(70°)
DOT min.
(See note 9.) 5.8 mm 4.8 mm 50°50°
DOF min.
(See note 9.) 20 N 20 N 20 N 20 N
!
!
F502-EN2-04.book Seite 234 Dienstag, 26. Juli 2005 5:48 17

G-235D4N
D4N
2-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Use the dog within 35 mm of the tip of the actuator and keep the total travel to 70 mm or less.
3. The usable range of the moving part is 1/3 or less of the entire spring length from the end of the spring.
Slow-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: Variation occurs in the simultaneity of contact opening/closing operations
of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
Snap-action (1NC/1NO), Slow-action (2NC) (3NC)
Two, 4+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Right Operation)
D4N-5@RE D4N-6@RE
D4N-7@RE D4N-8@RE
2.15±0.05R
mounting holes
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
39.3±1
(27.2)
26R
90°
47 max.
39±0.2
Two, 17.5 dia. ×
8 rubber rollers
Conduit cap
20.5 ×20.5
Two, 4+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Left Operation)
D4N-5@LE D4N-6@LE
D4N-7@LE D4N-8@LE
2.15±0.05R
mounting holes
Cap
Two, 17.5 dia. ×
8 rubber rollers
20.5 ×20.5
30
27.5
20.5
11
±0.2
21.5
14.2
39.3
±1
(27.2)
42
±0.2
(3)
56 max.
47
25 dia.
2.5
5.4
9
±0.2
18
20
±0.1
40
±0.1
42
±0.1
22
±0.1
90°
26R
47 max.
39
±0.2
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Cat Whisker
D4N-5@80 D4N-6@80
D4N-7@80 D4N-8@80 1.2-dia.
stainless
steel wire
(See note
2.)
2.15±0.05R
mounting holes
30
Cap
20.5
11±0.2
16.6 dia.
42±0.2 (3)
56 max.
47
25 dia.
2.5
20.5 ×20.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
(50.1)
PT
143.1 21.5
(31.5)
39±0.2
Sealing cap
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Plastic Rod
D4N-5@87 D4N-6@87
D4N-7@87 D4N-8@87
2.15±0.05R
mounting
holes
30
Cap
20.5
11±0.2
16.6 dia.
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
12±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
115
38
42
PT
(31.5)
21.5
39±0.2
Resin rod
(See note 2.)
Sealing cap
Conduit cap
Model D4N-@@RE D4N-@@LE
Force necessary to reverse the
direction of the lever: max. 6.4 N 6.4 N
Movement until the lever revers-
es 55 ±10°55 ±10°
Movement until switch operation
(NC) (6.5°)(6.5°)
(MBB: 10°)
Movement until switch operation
(NO) (18.5°) (18.5°)
(MBB: 5°)
Model D4N-@@80 D4N-@@87
OF max. 1.5 N 1.5 N
PT max. 15°15°
F502-EN2-04.book Seite 235 Dienstag, 26. Juli 2005 5:48 17

G-236 Safety Sensors / Components
Levers
Refer to the following for the angles and positions of the watchdogs (source: EN50047.)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Roller Lever
(D4N-@@20)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
(D4N-@@2G) (Reference Values)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
(D4N-@@2H) (Reference Values)
40±2
15±3
40+1
0
55
50
30°
20 min.
Dog
10 min.
Dog
5 min.
40±2
45
29±7
5±2
30°
30°
55+1
0
35+1
0
65R 20R
90
40 min.
Dog
15 min.
10 min.
42±2
110
75
30±7
11±3
30°
70+1
0
55+1
0
65R 31R
45 min.
25 min.
10 min.
Sealed Plunger
(D4N-@@31)
Roller Plunger
(D4N-@@32)
12.5
0
−2.5
18±0.5
Dog
15 min. 21 min.
Dog
Operating position
25+1
0
35
28±1
10±1.5
2.5
30°
12.5
0
−2.5
Dog
20 min.
10 min.
Operating position
25 min. 31 min.
One-way Roller Arm Lever
(Horizontal)
(D4N-@@62)
One-way Roller Arm Lever
(Vertical) (Reference Values)
(D4N-@@72)
30 max.
Dog
20 min.
31+1
0
10±2
40
5 min.
10 min.
30°
12.5
0
−2.5
30°
20 min.
31
41±2
22+1
0
5 min.
10 min.
12.5
0
−2.5
Dog
Fork Lever Lock
(Right Operation)
(D4N-@@RE)
Fork Lever Lock
(Left Operation)
(D4N-@@LE)
60
36
55°to 60°
5 to 9R
Dog setting range
40
28
60
36
55°to 60°
5 to 9R
Dog setting rang
e
40
28
Mounting
surface
Mounting
surface
F502-EN2-04.book Seite 236 Dienstag, 26. Juli 2005 5:48 17

G-237D4N
D4N
Safety Precautions
Refer to OMRON SAFETY COMPONENTS SERIES (Y106) for
common precautions for Switches and Safety Limit Switches.
Do not use metal connectors or metal conduits with this Switch.
Doing so may occasionally result in electric shock.
Precautions for Safe Use
•Do not drop the
Switch
. Doing so may result in the
Switch
not
performing to its full capacity.
•Do not attempt to disassemble or modify the
Switch
. Doing so may
cause the
Switch
to malfunction.
•Do not use the
Switch
where explosive gas, flammable gas, or any
other hazardous gas may be present.
•
Do not use the Switch submerged in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil or water entering the Switch interior. (The IP67 degree of
protection specification for the Switch refers to water penetration
while the Switch is submersed in water for a specified period of
time.)
•Protect the head from foreign material. Subjecting the head to
foreign material may result in premature wear or damage to the
Switch. Although the switch body is protected from penetration by
dust or water, the head is not protected from penetration by minute
particles or water.
•Turn the power OFF before wiring. Doing so may result in electric
shock.
•Install the cover after wiring. Not doing so may result in electric
shock.
•Connect a fuse to the Switch in series to protect the Switch from
short-circuit damage. Use a fuse with a breaking current 1.5 to 2
times larger than the rated current. To conform to EN ratings, use
an IEC60269-compliant 10-A fuse type gI or gG.
•Do not switch circuits for two or more standard loads (250 VAC,
3 A) at the same time. Doing so may adversely affect insulation
performance.
•The durability of the Switch is greatly affected by operating
conditions. Evaluate the Switch under actual working conditions
before permanent installation and use within a number of switching
operations that will not adversely affect the Switch’s performance.
•Be sure to indicate in the machine manufacturer’s instruction
manual that the user must not attempt to repair or maintain the
Switch and must contact the machine manufacturer for any repairs
or maintenance.
•Check the Switches before use and inspect regularly, replacing
them when necessary. If a Switch is kept pressed for an extended
period of time, the components may deteriorate quickly, and the
Switch may not release.
Precautions for Correct Use
Environment
•The Switch is intended for indoor use only.
•Do not use the Switch outdoors. Doing so may cause the Switch to
malfunction.
•Do not use the Switch where hazardous gases (e.g., H2S, SO2,
NH3, HNO3, CI2) are present or in locations subject to high
temperature and humidity. Doing so may result in damage to the
Switch caused by contact failure or corrosion.
•Do not use the Switch under any of the following conditions.
•Locations subject to extreme temperature changes.
•Locations where high humidity or condensation may occur.
•Locations subject to excessive vibration.
•Locations where metal dust, processing waste, oil, or chemicals
may penetrate through the protective door.
•Locations subject to detergents, thinner, or other solvents.
Mounting Method
Mounting Screw Tightening Torque
Tighten each of the screws to the specified torque. Loose screws
may result in malfunction of the Switch within a short time.
Switch Mounting
•Mount the Switch using M4 screws and washers and tighten the
screws to the specified torque.
•For safety, use screws that cannot be easily removed, or use an
equivalent measure to ensure that the Switch is secure.
•Secure the Switch with two M4 bolts and washers. Provide studs
with a diameter of 4−0.05/−0.15 and a height of 4.8 mm max. at two
places, inserting into the holes at the bottom of the Switch as
shown below so that the Switch is firmly fixed at four points.
Switch Mounting Holes One-conduit Type
Two-conduit Type
•Make sure that the dog contacts the actuator at a right angle.
Applying a load to the switch actuator (roller) on a slant may result
in deformation or damage of the actuator or rotary shaft.
CAUTION
1 Terminal screw 0.6 to 0.8 N·m
2 Cover clamping screw 0.5 to 0.7 N·m
3 Head clamping screw 0.5 to 0.6 N·m
4 Lever clamping screw 1.6 to 1.8 N·m
5 Body clamping screw 0.5 to 0.7 N·m
6 Conduit mounting connection,
M12 adaptor 1.8 to 2.2 N·m (except 1/2-
14NPT)
1.4 to 1.8 N·m (1/2-14NPT)
7 Cap screw 1.3 to 1.7 N·m
7
6
3
4
5
1
2
2.5±0.1
22±0.1
47±0.1
20±0.1
22±0.1
Two, M4
−0.15
4
−0.05
dia.
Height: 4.8 max.
42±0.1
39±0.1
20±0.1
22±0.1
40±0.1
42±0.1
2.5±0.1
5.35±0.1
Two, M4
−0.15
4−0.05 dia.
Hei
g
ht: 4.8 max.
F502-EN2-04.book Seite 237 Dienstag, 26. Juli 2005 5:48 17

G-238 Safety Sensors / Components
Wiring
•When connecting to the terminals via insulating tube and M3.5
crimp terminals, arrange the crimp terminals as shown below so
that they do not rise up onto the case or the cover. Applicable lead
wire size: AWG20 to AWG18 (0.5 to 0.75 mm2).
Use lead wires of an appropriate length, as shown below. Not doing
so may result in excess length causing the cover to rise and not fit
properly.
One-conduit Type (3 Poles)
Two-conduit Type (3 Poles)
•Do not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
•Use crimp terminals not more than 0.5 mm in thickness. Otherwise,
they will interfere with other components inside the case. The crimp
terminals shown below are not more than 0.5 mm thick.
J.S.T is a Japanese manufacturer.
Contact Arrangement
•The following diagrams show the contact arrangements used for
screw terminal types and connector types.
Screw Terminal Type
Connector Type
•Applicable socket: XS2F (OMRON).
•Refer to the G010 Connector Catalog for details on socket pin num-
bers and lead wire colors.
Socket Tightening (Connector Type)
•Turn the socket connector screws by hand and tighten until no
space remains between the socket and the plug.
•Make sure that the socket connector is tightened securely. Other-
wise, the rated degree of protection (IP67) may not be maintained
and vibration may loosen the socket connector.
Conduit Opening
•Connect a recommended connector to the opening of the conduit
and tighten the connector to the specified torque. The case may be
damaged if an excessive tightening torque is applied.
•When using 1/2-14NPT, wind sealing tape around the joint between
the connector and conduit opening so that the enclosure will con-
form to IP67.
•Use a cable with a suitable diameter for the connector.
•Attach and tighten a conduit cap to the unused conduit opening
when wiring. Tighten the conduit cap to the specified torque. The
conduit cap is provided with the Switch (2-conduit types).
Changing the Lever
The lever mounting screws can be used to set the lever position to
any position in a 360°angle at 7.5°increments. Grooves are incised
on the lever and rotary shaft that engage to prevent the lever from
slipping against the rotary shaft. The screws on adjustable roller
lever models can also loosened to change the length of the lever.
Remove the screws from the front of the lever before mounting the
lever in reverse (front/back), and set the level so that operation will be
completed before exceeding a range of 180°on the horizontal.
Manufacture Type Wire size
J.S.T. FV0.5-3.7 (F type)
V0.5-3.7 (straight type)
AWG20 (0.5 mm2)
Dog
Dog
2221
3433
1211
A
A
C
E
B
DF
C
E
B
D
F28 mm
Tolerance ±2 mm
33 mm
42 mm
2221
3433
1211
A
C
E
B
D
F
ACE
BDF
28 mm
Tolerance ±2 mm
Left hand
42 mm
ACE
BDF
28 mm
Tolerance ±2 mm
Right hand
42 mm
L
l F
B
D
dz
Correct Incorrect
Terminal screw
Crimp terminal
t: 0.5 mm
dz dia.: 3.7 mm
D dia.: 2.9 mm
B: 6.6 mm
L: 19 mm
F: 7.7 mm
I: 8.0 mm
14
32
13
31
D4N-@D@@ (3NC)
11
21
12
22
31 32
D4N-@B@@ (2NC)
D4N-@2@@ (2NC (SNAP))
11
31
12
32
D4N-@C@@ (2NC/1NO)
D4N-@F@@ (2NC/1NO (MBB))
D4N-@A@@ (1NC/1NO)
D4N-@E@@ (1NC/1NO (MBB))
33 34
11
21
12
22
11
33
12
34
D4N-@1@@ (1NC/1NO (SNAP))
14 (4)
32 (2)
(3) 13
(1) 31
1
3
2 4
Pin No. (Terminal No.)
D4N-9B@@ (2NC)
D4N-92@@ (2NC (SNAP))
D4N-9A@@ (1NC/1NO)
D4N-9E@@ (1NC/1NO (MBB))
(1) 11
(3) 31
12 (2)
32 (4)
(1) 11
(3) 33
12 (2)
34 (4)
D4N-91@@ (1NC/1NO (SNAP))
F502-EN2-04.book Seite 238 Dienstag, 26. Juli 2005 5:48 17
Other manuals for D4N Series
2
This manual suits for next models
169
Table of contents
Other Omron Switch manuals

Omron
Omron D4CC-1001 User manual

Omron
Omron G3M User manual

Omron
Omron D4JL-1NFA-C5 User manual

Omron
Omron D5B - User manual

Omron
Omron WLM - User manual

Omron
Omron D4N-R - User manual

Omron
Omron H5F - User manual

Omron
Omron D4D-R Series User manual

Omron
Omron D40A-G9SX-NS - User manual

Omron
Omron D4B-N - User manual