Optex VX-402R User manual

Safety-Related Precautions
Denotes a situation involving the risk of serious injury or damage to property if
the warning is ignored.
Caution
This icon denotes a situation involving the risk of serious injury or even death, if the
warning given is ignored.
Warning
This icon indicates actions to be avoided. Details of the actions to be avoided are written beside or near icon.
This icon indicates instructions that should be strictly followed.
Never use this product for any application except purpose for detecting
moving target such as a human or a car. In addition, never use for any
activation for a shutter or other. It may cause hazards.
Clean and inspect the device periodically for safe operation.
If any defect is detected, ask your local supplier to repair the device.
To avoid the risk of damaging the product, never touch the main body of the
product with wet hands. (Also, if the product is wet after rain do not touch it)
Never attempt to connect the terminals to units which reguire higher power
supply or current draw than its rating. It increases the risk of fire or damage
to the product.
Never attempt to disassemble or modify the product, which increases the risk
of fire or damage of the product.
Avoid applying water in directly from brackets, houses, or otherwise splash-
ing water directly onto the product. It increases the risk of damaging the
product.
Warning
Caution
·Before installation,make sure to read this instruction manual carefully for safe and effective product operation.
·After reading this installation manual, make sure to keep it in a convenient place for future use.
If the sensor is installed with some angle
to the ground, operational reliability of
the sensor may be decreased.
1.INSTALLATION HINTS
Avoid pointing the sensor towards moving
objects (i.e. swaying trees, bushes,
flags,etc.).
If moving objects are unavoidable, please
refer to TROUBLE SHOOTING reference
for proper installation.
1.Perpendicular Installation
Select a place for installing the VX-402R while keeping the following points in mind.
2. Installation height
0.8m-1.2m
VX-402R is designed to protect any light
disturbances.
However , too much light such as; strong
sunlight directed or reflected exactly into the
sensor’s field of view may cause unstable
operation. It is recommended to avid installing
in such a place.
The detection area has directionality.
Mount the detector so that it must be
passed in order to gain entry.
3.Detection Area Setup
Parallel
Install the sensor perpendicular to the
ground to making upper detection area
parallel to the ground.
Installation height is
0.8m-1.2m (2.7ft-4ft)
·Low Current Draw
·Battery Saving Circuit
·Operates on Wide Range of Power
·Back box for a wireless transmitter
·Limited Detection Range Function
·Size Judging Function
·Bright Light Disturbance Immunity
10uA (In Standby).
The alarm circuit will not be activated untill there is a 5 or 120 seconds period of inactivity in the pattern area.
3-9V Alkaline Battery or Lithium Battery.
Backbox can conceal a wireless transmitter circuitboad (W63mm x H140mm x D31mm).
The detection range of the VX-402R can be limited to avoid detecting unwanted objects. By limiting the
detection range, false alarms due to unwanted movement ( i.e. cars, persons or animals outside the
protected area ) can be reduced.
VX-402R is designed to discriminate between large and small animals. By utilizing this ability, false alarms
due to small animals can be reduced.
VX-402R is equipped with Double Conductive Shielding (Patent Listed). This shielding greatly reduces the
chance of false alarms due to car headlights, sunlight and other ambient light sources.
VX-402R
BATTERY OPERATED
FEATURES
VX-402R
MULTI STABILIZED OUTDOOR DETECTOR
BATTERY OPERATED
No.59-1048-1 0209-18
2 YEAR WARRANTY

2.DESCRIPTION AND OPERATION
M4 x 30
Lens Holder
Lens
Cover
Area Masking Plate
Pole Mount Bracket
Mounting Screw
T4 x 20
Terminals
Pyro Electric Sensor
(Do not touch)
Lock Screw
Cover
LED Indicator
DIP Switch (See 6-2.)
Detection Length
Adjustment Switch
Sensitivity Select Switch
(See 6-1.)
Battery
(Not included)
Transmitter
(Not included)

3.INSTALLATION
3-1.Before the Installation
3-2.Wall Mount
·Install the unit perpendicular to the ground.
·Installation height must be between 0.8m and 1.2m (2.7 ft and 4 ft).
·Secure a space 110mm (4.4") or more to the upper part of plate for opening and closing of the cover.
·Make sure that the rubber packing is seated correctly in its goove when you connect the detector with its back box.
(1)Install the back box on the wall with the
mounting screws provided (two places).
(3) Fasten with screws
(2) Pass the wiring through the wiring port
of the detector. After connecting the wires
to the terminals (See 4. Wiring), insert the
water protection sponge so that it blocks
the wiring port as shown in the figure.
Mount the detector on the back box.
(4) Adjust the DIP switch (See 6 Switch set up),
detectio area and sensitivity (See 5 Setting &
Adjustment). Secure the cover with the lock
screw.
Mounting Screw
Fasten the U-brackets on the polw with
the M4 x 30 screws provided. Mount in
accoundance with the wall mounting
procedure.
3-3.Pole Mount
An installation pole with an outside
diameter of 43-48mm (1.66"-)
must be used.
4.WIRING
Mount the mounting brackets on the back
box with tap screws (two places).
ALARM:[N.C./COM./N.O.]
POWER INPUT•F:3-9VDC
TAMPER:[N.C./COM./N.O.]
•{ •|
SPARE
(1)Loosen the lock screw and remove the
cover.
(2)Remove the screws fastening the back
box.
(3)Remove the back box.
When using VX-402R and transmitter together, the buttery life will be shortened depending on
the transmitter type (Current Draw). Only the expected battery life of VX-402R is shown in the
following chart. Battery life will change according to the temperature.
Approx. 3 years / 9V Alkaline Battery(560mAh),Interval 1 0sec
Approx. years / 9V Alkaline Battery(560mAh),Interval 5sec
Approx. 8 years / 3V Lithium Battery(1300mAh),Interval 1 0sec
Approx. 5 years / 3V Lithium Battery(1300mAh),Interval 5sec
Battery Life
(VX-40 R only)
IMPORTANT!

Press and slide the detection length adjustment switch to the desired position.
Detection Length
Adjustment Switch
*The maximum detection length may vary
as above due to environmental thermal
conditions.
Detection Length setting chart
Standard
1 .0 10.0 - 15.0
(40.0) (33.3 - 50.0)
8.0 6.0 - 10.0
( 6.7) ( 0.0 - 33.3)
5.0 4.0 - 5.5
(16.7) (13.3 - 18.3)
.0 1.5 - .5
(6.7) (5.0 - 8.3)
C
D
*
MAX DETECTION LENGTH
A
B
POSITION
5-3.Area Masking
1.Remove the lens holder
from the cover as
shown above.
5-2.Area Angle Adjustment
Active detection fingers.
45degree adjustable
45degree Adjustable
Top view
Area angle is 90degree with
7 fingers by 15degree per
notch.
(If you want to reduce the number
of fingers, fasten the lens with
the area masking plate provided.)
Hold the pyro electric
unit and turn it to the
desired direction
(15degree steps).
45•‹
90•‹
45•‹
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)(12)(13)
Lens and area correspon-
dence as seen from the inside
3.Put the lens back in by
aligning the 4 projections on
the cover to the 4 cut outs
on the lens.
(The lens has vertical
orientation. Be sure the lens is
correctly orientated when
mounting.)
2.Separate the lens from
the cover. Apply the
provided area masking
plate to the inside of the lens
on the zone to be eliminated.
4.Mount the lens holder. make
sure the lens holder is held
by left and right prongs on
the cover.
(Make sure the tabs [2] on the left
and right are engaged.)
(4) Projection
(2)
(1) (3) Projection
POSITION A (0-12m)
POSITION B (0-8m)
0 5 10 12 m
POSITION C (0-5m)
POSITION D (0-2m)
0 5 10 12 m
0 5 10 12 m
0 5 10 12 m
1m
1m
1m
1m
Instration Height=1m (3.3ft)
5-1.Detection Length Adjustment
5.SETTING & ADJUSTMENTS
Length of Lower Detecion Area decides detection length
The upper detection area stays parallel to the ground at all time. The lower detection area moves as shown above depending on the switch
position. Detection length is therefore limited by the length of lower detection area, since both upper and lower detection area have to be
blocked at the same time to activate the sensor.
Detection Length
NO
Detection
Only upper detection
area is blocked
Detection Length
Both upper and lower
detection area are
blocked!
Detection!
Detection Length
Only lower detection
area is blocked
NO
Detection
·This product detects temperature differences between the moving object and the background temperature in the detection
area. If the object does not move, the detector can not detect it.
·This product has directional characteristic it is difficult to detect the target that is approaching the detector.
·If there is a traffic near the dettection area, please adjust detectiion 1.5m to 2.0m (5ft to 7ft) away from movements.
IMPORTANT!
As shown above 5-2, there are always 7 active detection fingers. If the area masking plate is not applied, the active fingers
are varied by area adjustment as explained at left.
Please check which fingers are active before applying area masking plate.
IMPORTANT!
m(ft.)

6-2.DIP Switch Adjustment
1.Walk Test
6. Switch Setup
7.OPERATION TEST
1.Turn walk test switch on.
2.Check and adjust the detection area.
6-1.Sensitivity Adjustment
Sensitivity Select Switch
(L,M,H)
When greater sensitivity is desired, select
"H". When the installation site is poor (bad
conditions) select "L".
VX-402R has a multi-level detection pattern (from side view). A
heat source beyond the detection area may cause the detector to
issue a false alarm by reflecting off the ground. Examples of
reflective ground is water (puddle), wet road, smooth surface
concrete and asphalt road.
1) Please adjust the detection length to
position B. The detection length will be
around 8m (27ft) which is rather shorter
than ideal length but can remove the
chance of false detection.
IMPORTANT!
When the car or person goes near the detection area (a), please adjust the detection area 1.5m to 2m
(5ft to 7ft) shorter than movement area (b) and confirm by walk test. This is because, the actual
detection area may change from 1.5m to 2m (5ft to 7ft) due to the environmental thermal conditions.
The detection area might increase when there is a
big temperature difference between the moving
object and the background.
If the detection length adjusted to position A[12m (40ft)],
there is a possibility to detect the car, depending on the
environmental thermal conditions.
Approx.8m(27ft)
b
Approx.12m(40ft)
position B
a
In such case,
Confirm by walk test. Detects at area a and
no detection at area b.
2)
1)
2)
Example
(a)
(b)
Reflection rate is not 100% of course on the ground, however, if the heat source is strong and / or
reflection rate is high, detection distance will be longer than required and may detect unwanted
objects beyond. Select the detection ground position, according to the ground condition of the
installation site.
Approx.8m(27ft)
position B
Approx.13m(43ft)
Approx.12m(40ft)
position A
·ON (Walk Test Mode)
1)LED will light when detector is tripped.
2)Alarm will be generated instantly on detection.
·OFF (Battery Saving Mode)
1)LED is off.
1)Walk Test
2)Battery Saving Timer
3)Pulse Count
:Alarm output activations are limited by a timer selection -5 or 120
seconds. Even if there are continuous alarm events, the alarm output
operates only once in the timer period which can be between 5 and
120 seconds.
:Selectable pluse count 2 or 4.
120s 5s
OFF ON
42
2.Battery Saving Timer
3.Pulse Count

9.SPECIFICATION
8.TROUBLE SHOTING
This unit is designed to detect movement of an intruder
and activate an alarm control panel.
Being only a part of a complete system, we cannot
accept responsibility for any damages or other
consequences resulting from an intrusion.
This Product conforms to the EMC Directive.89/336 EEC.
Note: Specifications and design are subject to change without prior notice.
NOTE
OPTEX CO., LTD. (ISO 9001 Certified by LRQA)
4-7-5 Nionohama Otsu 520-0801 Japan
TEL(077)524-6047 FAX(077)522-9022
URL http://www.optex.co.jp/e/sec/index.html
OPTEX INCORPORATED
1845W 205th Street Torrance,CA 90501-1510 U.S.A.
TEL(310)533-1500 FAX(310)533-5910
URL http://www.optexamerica.com
OPTEX (EUROPE) LTD. (ISO 9002 Certified by NQA)
Unit 9, Four Seasons Crescent, Sutton, Surrey. SM3 9QR. UK
TEL: (02082)542222 FAX: (02086)410017
URL http://www.optexeurope.com
PROBLEM PROBABLE CAUSE REMEDY
Incorrect pow er supply voltage. Set supply voltage for a range of 3 to 9 battery.
Faulty w iring to detector. Transmitter is not connected to
VX-40 R. Rew ire alarm correcty.
Wireless transmission dose not reach the receiver. Check transmitter.
Battery is dead. Change batteries.
Walk Test Sw itch is OFF. Battery saving circuit .
LED blinks continuously Incorrect pow er supply voltage. Set supply voltage for a range of 3 to 9 battery.
Detector is not installed perpendicularly to the ground. Reinstall the detector perpendicularly to the ground.
Low er detection area is unnecessarily long. Confirm and reset the detection area.
Low er detection area receives reflected sunlight or car
light, etc.
Remove the reflector or reset the detection area or mask
the area exposed to reflected light.
Low er detection area is exposed to direct sunlight or car
light. Reset the area so it may not receive direct light.
There is any heat source (stove or heater, etc.) in the
area that may cause temperature change. Reset the area or remove the heat source.
There is any moving object (laundry on clothesline, plants,
etc.) in the area. Reset the area or remove moving objects.
Detection area is not set appropriately. Reset the area appropriately.
Sensitivity is set for L(ow ). Reset sensitivity for M(edium) or H(igh).
No detection
occasionally
Make alarms even
though no moving object
is in the area
No alarm event even
though someone is
w alking in detection
area.
Pitch 83.5mm(3.28•h)68.5mm(2.7•h)
198mm(7.8•”)
80mm(3.15”) 108(4.25•”)
mm(inch)
[Dimensions]
MODEL VX-40 R
Detection Method Passive Infrared
Coverage 1 m(40ft)90°wide
Detection Zone 14zones
Mountiong Height 0.8-1. m( .7-4ft)
Sensitivity .0°C at 0.6m/s (3.6°F at .0ft./s)
Detectable Speed 0.3-1.5m/s(1-5ft/s)
Power Input 3-9VDC Alkaline or Lithium Battery
Operating Voltage .5V - 10VDC
Max. 3mA(In Walktest,LED on)
10uA(In Standby)
Alarm Period Approx .5sec
Alarm Output Form C-Solid State Switch: 10VDC,0.01A
Battery Saving Timer Approx. 1 0sec or 5sec
Tamper Switch Form C opens when cover removed
Pulse Count Approx 0sec or4
Warm-up Period Approx. min
Disable during normal operation
Enable during walk test
Weatherproof IP54
Operating Tamperature - 0 - +50°C (-4 - +1 °F)
Environment Humidity 95% Max
RF Interference No Alarm 30V/m
Mountiong Wall,Pole
Weight 480g(16.9oz)
Accessories Pole mount kit, Screw kit, Area Masking Plate
LED Indicator
Current Draw
Table of contents
Other Optex Security Sensor manuals

Optex
Optex FTN-R User manual

Optex
Optex sensor User manual

Optex
Optex OA-4500S User manual

Optex
Optex OVS-50TNR User manual

Optex
Optex FlipX Series User manual

Optex
Optex BX SHIELD Series User manual

Optex
Optex HX-40RAM User manual

Optex
Optex OML-ST User manual

Optex
Optex QX Infinity Series User manual

Optex
Optex URX-P01WH Operation and maintenance manual

Optex
Optex AX-70TN User manual

Optex
Optex WX Shield Series User manual

Optex
Optex HX-40 User manual

Optex
Optex PROWAVE AIR-SLIDE 2 User manual

Optex
Optex LX-402 User manual

Optex
Optex REACTION TWO User manual

Optex
Optex VX Shield Series User manual

Optex
Optex OVS-01GT User manual

Optex
Optex Boundary Gard BX-80N Manual

Optex
Optex AX-70TN User manual