CAUTIONS
2
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
This product has been developed / produced for industrial use.
Make sure that the power supply is off while wiring or adding the units.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
Do not use during the initial transient time (0.5 sec.) after the power
supply is switched on.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Be sure to use the optional quick-connection cable for amplifier
connection. Furthermore, extension up to 100m (50m: 5 to 8 units are
connected in cascade, 20m: 9 to 16 units are connected in cascade) is
possible with 0.3mm2or more, cable. However, in order to reduce noise,
make the wiring as short as possible.
Take care that when the cable is extended, the residual voltage rises.
Do not shorten or lengthen the sensor head cable.
This sensor is suitable for indoor use only.
Do not use the sensor at places having intense vibrations, as this can
cause malfunction.
Take care that the sensor does not come in direct contact with water, oil,
grease, organic solvents, such as, thinner etc., or strong acid, and alkaline.
Make sure that the sensing end is not covered with metal dust, scrap or
spatter. It will result in malfunction.
Take care that stress by forcible bending or pulling is not applied directly
to the sensor head cable joint.
SPECIFICATIONS
1
Cable (Note 4)
Connector attached oil resistant high frequency coaxial cable, 3m long
[Spatter resistant cable for GH-F8SE (Outer shield: Fluorine resin)]
Enclosure:
SUS303
Sensing part:
PVC
Enclosure:
SUS303
Sensing part:
ABS
Enclosure:
SUS303
Sensing part:
PAR
Enclosure:
SUS303
Sensing part:
ABS
Enclosure:
SUS303
Sensing part:
Fluorine resin
Material
Temp. characteristic
(Note 3)
Within r5%Within r7% Within r4%
-10 to +60, Storage: -20 to +70Ambient temperature
IP50 (IEC)
IP67 (IEC), IP67g (JEM)Protection
0.04mm or less
0.07mm or less
0.05mm or lessHysteresis (Note 2)
Iron 1010t1mm
Stable sensing range
(Note 1)
0 to 0.8mm0 to 0.6mm 0 to 2.0mm0 to 1.0mm
Max. operation distance
(Note 1)
1.8mm1.2mm 4.0mm2.4mm
GH-3SE GH-F8SEGH-2SE GH-8SEGH-5SE
Spatter-resistant type
Cylindrical type
GA-311Applicable amplifier
Model No.
Item
Type
Iron 55t1mmStandard sensing object
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
15g approx.
35g
approx.
40g
approx.
55g
approx.
Weight
٨Sensor head
Notes: 1)
2)
3)
4)
The stable sensing range represents the sensing range for which the sensor
can satisfy all the given specifications with the standard sensing object.
The maximum operation distance represents the maximum distance for
which the sensor can detect at +20constant ambient temperature.
Usage within the stable sensing range is recommended for accurate
sensing applications.
Value is given for the stable sensing range.
The value represents the variation in the operation distance, that has been
set within the stable sensing range at +20, for an ambient temperature
drift from 0 to +55. (The value is for sensor head on its own.)
The length of the sensor head cable cannot be changed.
Notes: 1)
2)
3)
50mA, if five, or more, amplifiers are connected in cascade.
The value represents the variation in the operation distance, that has been
set within the stable sensing range at +20, for an ambient temperature
drift from 0 to +55. (The value is for amplifier on its own.)
The cable for amplifier connection is not supplied as an accessory. Make
sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1m), CN-73-C2 (cable length 2m)
CN-73-C5 (cable length 5m)
Sub-cable (1-core) : CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m)
CN-71-C5 (cable length 5m)
25mA or lessCurrent consumption
12 to 24V DCr10 %ޓRipple P-P10 % or lessSupply voltage
Type
Item GA-311
Output
NPN open-collector transistor
࡮Maximum sink current: 100mA
࡮Applied voltage: 30V DC or less (between output and 0V)
࡮Residual voltage: 1V or less [at 100mA (Note 1) sink current]
18-turn potensiometerSensitivity adjuster
Orange LED (lights up when the output is ON)Operation indicator
Max. response frequency
3.3kHz
Normally open / closed Selectable with the operation mode switchOutput operation
Incorporated
Short-circuit protection
Red LED (lights up when the sensor head is disconnected or mis-contacted)
Disconnection alarm indicator
Ambient temperature
-10 to +60(if 4 to 7 units are connected in cascade: -10 to +50,
if 8 to 16 units are connected in cascade: -10 to +45) (No dew con-
densation or icing allowed), Storage: -20 to +70
Temp. characteristic
(Note 2)
Within r5%
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate
Material
15g approx.Weight
٨Amplifier
MOUNTING
3
Be sure to use a sensor head and amplifier as a set.
Disconnection method
Ԙ
Pressing the projection on the sensor
head connector, pull out the connector.
Connection method
Ԙ
ԙ
Insert the the sensor head connector into
the connector inlet till a click is felt.
Fit the cover on the connector.
٨Connection of sensor head
Ԙ
Sensor head
connector part
Cover
ԙ
Projection
Take care that if the connector is pulled out without pressing the projection, the pro-
jection may break. Do not use a sensor head connector whose projection has bro-
ken. Furthermore, do not pull by holding the cable, as this can cause a cable-break.
Note:
Ԙ
ԙ
Fit the rear part of the mounting section of the
amplifier on a 35mm width DIN rail.
Press down the rear part of the mounting section
of the unit on the 35mm width DIN rail and fit the
front part of the mounting section to the DIN rail.
How to mount the amplifier
Take care that if the front part is lifted without pushing the amplifier forward, the
hook on the rear portion of the mounting section is likely to break.
Note:
How to remove the amplifier
Ԙ
ԙ
Push the amplifier forward.
Lift up the front part of the amplifier to remove it.
٨Mounting of amplifier
Ԙ
35mm width DIN rail
ԙ
Ԙ
ԙ
Do not tighten it with excessive strength.Note:
٨Mounting of sensor head
࡮The tightening torque
for mounting should be
as given right.
Furthermore, be sure
to use a set screw with
a cup-point end.
0.17N㨯m
4 or more
0.78N㨯m
GH-3SE
5 or more
0.59N㨯m
GH-5SE
5 or more
GH-8SE
GH-F8SE
Model No. Amm
Tightening torque
3 or more
0.17N㨯mGH-2SE
Set screw (M3)
(Cup-point end)
A
Mounting with a set screw
Influence of surrounding metal
࡮The surrounding metal
will affect the sensing
performance. Keep the
minimum distance
specified in the table
right.
4GH-3SE
5GH-5SE
9
GH-8SE
GH-F8SE
Model No. Bmm
3GH-2SE
B
Background metal
٨
٨
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products
which meet laws and standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or country.
WARNING
Thank you very much for purchasing Panasonic products. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.
INSTRUCTION MANUAL
Amplifier-separated Type Inductive Proximity Sensor
Amplifier GA-311 Sensor head GH-غSE
MJE-GA311 No.0034-54V
Ramco National
www.PanasonicSensors.com
1-800-280-6933
CONNECTION
4
Make sure that the power supply is off while connecting / disconnecting the
quick-connection cable.
Connection method
Disconnection method
Note: Take care that if the connector is pulled out without pressing the
projection, the projection may break. Do not use a quick-connection cable whose
projection has broken.
Furthermore, do not pull by holding the cable, as this can cause a cable-break.
ԘPressing the projection at the top of the
quick-connection cable connector, pull out
the connector.
Projection
Ԙ
ԙ
Holding the connector of the quick-connec-
tion cable, align its projection with the
groove at the top portion of the amplifier
connector.
Insert the connector till a click is felt.
Groove
Projection
Quick-connection cable
٨
࡮
Sensing range
The sensing range is specified for the standard sensing object. With a
non-ferrous metal, the sensing range is obtained by multiplying with the
correction coefficient specified below.
Note: The sensing range also changes if the sensing object is plated.
Correction coefficient
Aluminum
Brass
Stainless steel
(SUS304)
Model No.
1111
0.68 approx.
0.51 approx.
0.53 approx.
0.69 approx.
0.39 approx.
0.41 approx.
0.64 approx.
0.32 approx.
0.37 approx.
0.55 approx.
0.33 approx.
0.35 approx.
GH-8SE
GH-F8SE
GH-2SE GH-3SE GH-5SE
Metal
Iron
٨
࡮
Mutual interference
When two or more sensors are installed in parallel or face to face, keep the
minimum separation distance specified below to avoid mutual interference.
15
20
26
D (mm)
10
20GH-3SE
25GH-5SE
40
GH-8SE
GH-F8SE
Model No. C (mm)
15GH-2SE
Face to face mounting
C
Parallel mounting
D
٨
٨
٨
٨
٨
٨
٨
Make sure that the power is off while cascading / removing the amplifiers.
Be sure to check the allowable ambient temperature, as it depends on
the number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure
to mount them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching
condition, fitting them between the optional end plates (MS-DIN-E)
mounted at the two ends.
When connecting in cascade, mount the amplifiers close to each other,
fitting them between the optional end plates (MS-DIN-E) mounted at the
two ends.
When connecting more than two amplifiers in cascade, use the sub ca-
ble (CN-71-Cغ) as the quick-connection cable for the second amplifier
onwards.
This product does not incorporate the communication function. When
this product used by cascading along with other than this product,
mount at the either side of the cascaded products.
CASCADING UNITS
5
Refer to the ' MOUNTING' for mounting / dismantling the amplifiers.
3
Cascading method
Ԙ
ԙ
Ԛ
ԛ
Mount the amplifiers, one by
one, on the 35mm width DIN
and set them close to each
other without any gap between
them.
Connect the quick-connection
cables to the amplifiers.
Mount the end plate (MS-DIN-E)
(optional) at both ends to hold
the units between their flat sides.
Tighten the screws to fix the
end plates (MS-DIN-E)
Dismantling
Ԙ
ԙ
Pressing the projection at the top
of the quick connection cable
connector, pull out the connector.
Remove the amplifiers.
Main cable
(CN-73-Cغ) (optional)
Sub-cable
(CN-71-Cغ)
(optional)
End plate
(MS-DIN-E) (optional)
End plate
(MS-DIN-E)
(optional)
PART DESCRIPTION
7
Operation indicator (Orange)
Disconnection alarm indicator (Red) Operation mode switch
Sensitivity adjuster
I/O DIAGRAMS
6
Note: The quick-connection cable does not have +V (Blown) and 0V (Blue). The
supply voltage is supplied through the main cable connector.
Symbols... D
ZD
Tr
: Reverse supply polarity protection diode
: Surge absorption zener diode
: NPN output transistor
Sensor head side connector
Power supply side connector
٨Terminal arrangement diagram
Ԙ㧗V
ԚOutput
ԙ0V
ԘNot used
ԙSignal wire
ԛNot used
ԚShielded wire
D
100mA max.
1
2
3
1
4
2
3
ZD
Tr
Connector pin No. for power supply side
Connector pin No. for the sensor head side
Load
(Brown) +V (Note)
(Black) Output
+12 to 24V DC
r10%

(Blue) 0V (Note)
User's circuitInternal circuit
Color code of quick-connection cable
Not used
Signal wire
Shielded wire
Not used
Sensor circuit
SENSITIVITY ADJUSTMENT
8
Step Sensing condition Adjustment
ԘSet the operation mode switch to
NORM. (Initial setting)
࡮
Turn the sensitivity adjuster fully coun-
terclockwise. (Minimum sensitivity)
Sensitivity adjuster
Approach
along sens-
ing axis
Approach
perpendicu-
lar to sens-
ing axis
ԚSelect the operation mode as per your application.
(NORM.: Normally open, INV.: Normally closed)
ԙ
Sensing object
Sensor
head
Movement
direction
Sensing object
Sensor
head
Movement
direction
࡮
࡮
Place the sensing object within the
stable sensing range.
Turn the sensitivity adjuster clockwise
and set it at the point where the op-
eration indicator (orange) lights up.
࡮
࡮
Place the sensing object within the
stable sensing range.
Turn the sensitivity adjuster clockwise,
and set it at the optimum sensing point
which is a little beyond the point where
the operation indicator (orange) lights up.
Note: Use a flathead screwdriver (please arrange separately) to turn the adjuster
slowly. Turning with excessive strength will cause damage to the adjuster.
DIMENSIONS (Unit: mm)
9
٨GH-غSE / Sensor head
A
BC
Cable 3m long
15
15
15
B
12
Ǿ3.8GH-3SE
Ǿ5.4GH-5SE
GH-8SE Ǿ8.0
15
Ǿ2.5
Ǿ2.5
Ǿ2.5
C
Ǿ1.6
Ǿ2.65GH-F8SE Ǿ8.0
Model No. A
Ǿ2.8GH-2SE
٨GA-311 / Amplifier 1.9 0.4
21.95
33.5
53.72.5
4.65
15.55
10
6.3
64.5(16) (7)
36.5 14.5
30.5
3 3.95
10.5
Sensor head
connector
Connector cover
Quick-connection
connector
Note:
The side view is with the sensor head connector and the quick-connection cable.
http://panasonic.net/id/pidsx/global
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2012
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
Ramco National
www.PanasonicSensors.com
1-800-280-6933

This manual suits for next models

5

Other Panasonic Accessories manuals

Panasonic MA3J745E User manual

Panasonic

Panasonic MA3J745E User manual

Panasonic Light Emitting Diodes LNG0A8CYBZ User manual

Panasonic

Panasonic Light Emitting Diodes LNG0A8CYBZ User manual

Panasonic EX-F70 SERIES User manual

Panasonic

Panasonic EX-F70 SERIES User manual

Panasonic MALS180XG User manual

Panasonic

Panasonic MALS180XG User manual

Panasonic HL-G1 Series User manual

Panasonic

Panasonic HL-G1 Series User manual

Panasonic MAS3795EG User manual

Panasonic

Panasonic MAS3795EG User manual

Panasonic WJ-PB85L32 User manual

Panasonic

Panasonic WJ-PB85L32 User manual

Panasonic LS-H F-A Series User manual

Panasonic

Panasonic LS-H F-A Series User manual

Panasonic MA26111 User manual

Panasonic

Panasonic MA26111 User manual

Panasonic MA2DF31 User manual

Panasonic

Panasonic MA2DF31 User manual

Panasonic CY-100 Series User manual

Panasonic

Panasonic CY-100 Series User manual

Panasonic MA2YD17 User manual

Panasonic

Panasonic MA2YD17 User manual

Panasonic MA3S1370G User manual

Panasonic

Panasonic MA3S1370G User manual

Panasonic Touch Pen Installation and operating instructions

Panasonic

Panasonic Touch Pen Installation and operating instructions

Panasonic HL-C203F User manual

Panasonic

Panasonic HL-C203F User manual

Panasonic CF-VNP Series User manual

Panasonic

Panasonic CF-VNP Series User manual

Panasonic MA3X787 (MA787) User manual

Panasonic

Panasonic MA3X787 (MA787) User manual

Panasonic MA2SE010G User manual

Panasonic

Panasonic MA2SE010G User manual

Panasonic EQ-500 Series User manual

Panasonic

Panasonic EQ-500 Series User manual

Panasonic MA271110G User manual

Panasonic

Panasonic MA271110G User manual

Panasonic Light Emitting Diodes LNJ0F1C5FRA1 User manual

Panasonic

Panasonic Light Emitting Diodes LNJ0F1C5FRA1 User manual

Panasonic CX-400 Series User manual

Panasonic

Panasonic CX-400 Series User manual

Panasonic HL-C211F User manual

Panasonic

Panasonic HL-C211F User manual

Panasonic SU-7 Series User manual

Panasonic

Panasonic SU-7 Series User manual

Popular Accessories manuals by other brands

PASCO PASPort PS-2120 quick start guide

PASCO

PASCO PASPort PS-2120 quick start guide

POLTI SANI SYSTEM manual

POLTI

POLTI SANI SYSTEM manual

SICK LMS4000 operating instructions

SICK

SICK LMS4000 operating instructions

Beckhoff CX2500-0070 manual

Beckhoff

Beckhoff CX2500-0070 manual

Lippert Components Solera Slide Topper Installation and owner's manual

Lippert Components

Lippert Components Solera Slide Topper Installation and owner's manual

WDT DUFTDOS-AK1 operating instructions

WDT

WDT DUFTDOS-AK1 operating instructions

Foerster CORCOGRAPH Ro 20 P operating instructions

Foerster

Foerster CORCOGRAPH Ro 20 P operating instructions

dymax UVCS user guide

dymax

dymax UVCS user guide

Foscam 305503000664 user manual

Foscam

Foscam 305503000664 user manual

Varec 2500 Installation and operation manual

Varec

Varec 2500 Installation and operation manual

METER TEROS 11 Integrator guide

METER

METER TEROS 11 Integrator guide

E+E Elektronik EE850 user manual

E+E Elektronik

E+E Elektronik EE850 user manual

RDI Prestige K10 Instructions for use

RDI

RDI Prestige K10 Instructions for use

Avery Weigh-Tronix 640XL manual

Avery Weigh-Tronix

Avery Weigh-Tronix 640XL manual

iOptron ZEQ25 Instruction

iOptron

iOptron ZEQ25 Instruction

Medisana 60230 instruction manual

Medisana

Medisana 60230 instruction manual

OpenTag OpenTag3 manual

OpenTag

OpenTag OpenTag3 manual

Minoston MP23W quick guide

Minoston

Minoston MP23W quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.