• Anzeigen und Bedienelemente
H1-H2: Schaltzustand / Senderfehler-Anzeige - gelb
H3-H4: Empndlichkeit / Empfängerfehler-Anzeige - grün
H5-H6: Sensor-Fehler - rot
H7: Alarmanzeige - rot
H8: Betriebsanzeige - grün
P1-P2: Empndlichkeitseinsteller für Manuell-Betrieb
S1-S3: DIP-Schalter Kanal 1
S4-S6: DIP-Schalter Kanal 2
S7: Test / Reset-Taster
• Display content and operating elements
H1-H2: Switching indicator / Transmitter error - yellow
H3-H4: Sensitivity display / Receiver error - green
H5-H6: Sensor Error display - red
H7: Alarm display - red
H8: Power On display - green
P1-P2: Manual Gain control
S1-S3: DIP-switch channel 1
S4-S6: DIP-switch channel 2
S7: Test / Reset-Taster
• Inbetriebnahme
Vor Inbetriebnahme DIP-Schalter S1 - S3 (S4 - S6) am Gerät passend einstellen.
Sensoren aufeinander ausrichten. Nach Anlegen der Betriebsspannung und
automatischem Reset, stellt sich in der Betriebsart Automatik die Sendeleistung
selbstständig ein. Bei fehlerfreiem Betrieb leuchtet H3 (H4) auf (Automatik aktiv).
Gleichzeitig leuchtet in Hellschaltung H1 (H2). In der Betriebsart Manuell muss der
Anwender die Sendeleistung mit P1 (P2) auf die erforderliche Höhe bringen, sodass
bei Sichtverbindung H3 (H4) leuchtet. In Hellschaltung leuchtet auch hier gleichzeitig
H1 (H2) (siehe Tabelle: Schaltlogik).
• - Alarm - mit Alarmausgang
Der Alarmzustand tritt ein, wenn die Sendeleistung im Manuell-Betrieb nicht ausreichend
ist, oder im Automatik-Betrieb der Prozessor nicht mehr nachregeln kann. Ursache
ist z. B. eine Verschlechterung der Sicht, eine zu große Distanz oder Dejustage der
Sensoren. Nach Beseitigung des Fehlers erlischt die Anzeige.
• Testeingang
Legt man an den Testeingang 24 V DC an, so schaltet der Sender ab. Damit kann die
Funktion der Lichtschranke überprüft werden.
• - Test -
Durch kurzes Drücken von S7 - Funktion Test - wird erst die Streckenqualität von
Kanal 1 durch Blinken von H3 (1x - schlecht bis 10x - sehr gut) angezeigt. Ist keine
Sichtverbindung vorhanden, blinkt lediglich H5. Danach folgt das Ergebnis von Kanal
2 mit H4. Ist hier keine Sichtverbindung vorhanden, blinkt lediglich H6.
• - Reset -
Nach Anlegen der Betriebsspannung oder langes Drücken von S7, führt das Gerät
einen Reset durch. Der Reset beinhaltet einen Lampentest. Alle Anzeigen erlischen
und leuchten danach kurz auf. Zusätzlich ndet im Automatik-Betrieb eine automatische
Neuregelung der Sendeleistung vom Maximalwert auf den Sollwert statt.
• - Sensor Error - mit Errorausgang
Mit der Sensor Error-Funktion überwacht das Gerät den elektrischen Zustand der
Sensoren auf Kurzschluss und Unterbrechung. Tritt ein Fehler auf, so meldet dies
das Gerät durch die Anzeigeelemente. Schnelles Blinken bedeutet Kurzschluss und
langsames Blinken bedeutet Unterbrechung (siehe Tabelle Logik Sensor Error).
• Operating procedure
Before operating procedure you have to choose the DIP switch setting S1 - S3 (S4-S6)
for your application. Sensor heads adjusts one on top of the other. After switch on the
power supply and automatic reset, the transmit power will be turned to the optimum
(automatic mode). When there is no error LED H3 (H4) lights (automatic active) and
H1(H2) lights (in light switching mode). In the Manual mode you have to adjust the
transmit power with P1 (P2) until H3 (H4) signals sufcient power. In light switching
mode H1 (H2) lights too (See also table: Switching logic).
• - Alarm - with Alarm output
Alarm is active, when the transmit power is not sufcient in the Manual mode or the
automatic adjustment is interrupted. The cause can be e.g. deterioration of the beam,
too large distance or misadjustment of sensor heads. Is the cause removed, the alarm
is no longer active.
• Test input
With a voltage about 24 V DC at the test input, the transmitter beam switches off. With
this feature you can test the system.
• - Test -
Short-time pressing of button S7 results ashes between 1 and 10 times of H3 to signal
the received power of channel 1. They are proportional to the received signal. If there
is no received signal, only H5 ashes up. After that the same procedure starts with
channel 2. Here H4 signals the quality and if there is no signal, only H6 ashes up.
• - Reset -
After connecting the device with power supply or pressing of button S7 for longer time,
a Reset will done. This means a test of all displays. All LEDs lights down and up for
a short time. Additionally in Automatic mode a new adjustment of the transmit power
starts from maximum to the nominal value.
• - Sensor Error - with error output
This function controls the electrical state of the sensor heads. If there is an error
(short-circuit or too high resistance resp. disconnection) H5 (H6) lights up. Additionally
H1 (H2) (= transmitter error) or / and H3 (H4) (= receiver error) ashes slowly (= high
resistance) or fast (= short-circuit). See for this table Logic Sensor Error.
• Logik Sensor Error / Logic Sensor Error • Maßzeichnungen / Dimensions in mm
Technische Daten (bei 20 °C Ub= 24 V DC) ISM-2000(S) Technical data (at 20 °C (68 °F), Vs= 24 V DC)
Betriebsspannung 24 V DC / ± 20% / 3,6 W Supply power
Messverfahren moduliertes IR-Licht modulated IR-light Operating basis
Maximale Reichweite (Einweg) Maximum range (Through beam)
Sender Empfänger / Receiver IRL-... Empfänger / Receiver IRH-..., IR-... Transmitter
ITL-..., IT-... 8 m (26 ft) 20 m (66 ft) ITL-..., IT-...
ITH-..., IT-...HP 10 m (33 ft) 30 m (99 ft) ITH-..., IT-...HP
ITA-... 20 m (66 ft) 55 m (182 ft) ITA-...
Sendefrequenz 3,9 kHz Transmit frequency
Multiplexgeschwindigkeit 8 ms Multiplex speed
Sendeleistung manuell / automatisch manual / automatic Transmit power
Schaltfunktion bzw. Schaltverhalten hell / dunkel light / dark Switching behavior
Grundleistung high / low System power manual mode
Schaltverzögerung / Impulsbreite — Switching delay / impulse period
Schaltausgang (kurzschlussfest) Schließer (Halbleiter-Relais) NO (Semiconductor-Relay) Switching output (short-circuit proof)
Schaltwerte maximal 100 mA / 60 V AC (DC) Maximum values
Reaktionszeit 24 ms Reaction time
Alarm-/Errorausgang (kurzschlussfest) pnp: 100 mA / 24 V DC Alarm / Error output (short-circuit proof)
Analogausgang — Analog output
Testeingang Active HIGH (L= 0 ... 5 V DC, H= 15 ... 30 V DC) Test input
Gehäusewerkstoff NORYL RAL 7035 (grau / grey) Housing material
Schutzart IP 20 Protection class
Anschluss-Querschnitt 0,14 ... 2,5 mm² Terminal size
Maximale Kabellänge (Sensor-/Signalanschlüsse) 30 m Maximum cable length (sensor and signal connections)
Betriebstemperatur -25 °C ... +50 °C (-13 °F ... +122 °F) Operating temperature
Gehäuseabmessungen siehe Maßzeichnung see dimensions Housing measurements
Prüfungen Approvals