GlassTrek delivers effective coverage of plate, tempered, and laminated glass
without the need for special sensitivity adjustments. GlassTrek can be used in
most protected areas, including rooms with blinds, curtains, or multiple
windows, as long as careful coverage tests are conducted using TestTrek.
Breakage in panes of glass 40.6cm x 61cm (16in x 24in) or larger will be
detected, for every standard thickness of plate (0.3cm x 0.6cm or 1/8in-1/4in).
The GlassTrek detector should not be connected to 24 hour protection
zones. Installation is not recommended in protected areas that contain
any of the following: windows with closed wooden interior shutters,
windows with insulated, lined, or sound-muffling drapes, and rooms
with ceilings higher than 4.5m (15ft). If ceiling-mounted, it should not
be mounted in rooms smaller than 3m x 3m (10ft x 10ft) where loud
noise is common or rooms where machinery noise is present.
Installation Location
Look for installation locations on the ceiling or walls adjacent or opposite to
the protected glass and ensure that the installation will respect the detection
angle as shown in figure 1. Make sure that the microphone side of the
detector has a direct and unobstructed view of the protected glass and that
the detector is positioned so that the protected glass lies within the optimal
detection angle. Avoid proximity to noisy objects such as bells, fans,
compressors and loud machinery.
Installing GlassTrek (see figure 3)
1. Remove the cover by pressing the opening pin (A) on the side of the
detector.
2. Remove the PCB and run the wires through one of the openings on the
side (C) or back (D) of the case.
3. Mount the detector in its location by drilling screws into the screw holes
(B).
4. Connect the PCB terminals (see figure 2).
5. Replace the PCB and close the cover.
6. Test the GlassTrek (see “Test Mode” under “Utilities”).
Powering Up
After the initial power up sequence, the GlassTrek unit remains in test mode
for approximately 1 minute.
Display Mode
Red LED:
1. Intermittent flashing takes place upon recognition of high level attack
signals. (Can be tested by clapping or knocking close to the detector.)
2. 5-second illumination if a glass break is detected when alarm memory
latch is "off" (J1 ON).
3. Continuous illumination upon detection of a glass break when alarm
memory latch is "on" (J1 OFF).
4. 3-minute continuous flashing indicates unit is in "test" mode.
Green LED:
Will flash intermittently when spectrum analysis is in progress, indicating
attack analysis has been successfully confirmed and part of the frequency
spectrum is valid.
Detector Settings
Utilities
DG457 Digiplex Mode or Stand-Alone Mode
457 Stand-Alone Mode only
DG457 / 457
V1.0
Instructions
Printed in Canada 7/2007 paradox.com 457-EI00
Step Details
1
Operational
Mode
Jumper J3 ON = Combus mode; go to step 2
J3 OFF = Relay mode; go to step 3 (default)
2†
Enter detector programming mode.
Press and hold [0] + [INSTALLER CODE]+ [4003] (EVO) + S.N.
(located on PCB)
3
Sensitivity
Setting
Regular sensitivity
If the environment has damping materials such as drapes,
carpets, furniture. Install at 1.2m to 9m (4ft to 30ft) from the
protected glass.
Low sensitivity
If the environment produces echoes, as when the walls and
ceilings are concrete or metal. Install at 1.2m to 4.5m (4ft to
15ft) from the protected glass.
Section [001]†:[1] OFF = Regular Sensitivity (default)
[1] ON = Low Sensitivity
Jumper J2 OFF = Regular Sensitivity (default)
J2 ON = Low Sensitivity
4
Alarm
Memory
When an alarm occurs, the alarm relay remains latched for 5
seconds. The alarm memory feature can also latch the red LED
upon detection.
Alarm memory disabled:
The red LED illuminates for 5 seconds.
Alarm memory enabled:
The red LED remains on (latched) until you set jumper J1 on
and remove it again, or you disable Alarm Memory in section
[001], or you disconnect and restore power to the detector.
Section [001]†:[3] OFF = Alarm memory disabled (default)
[3] ON = Alarm memory enabled
Jumper J1 OFF = Alarm memory enabled
J1 ON = Alarm memory disabled (default)
5
Tamper
Recognition
Select tamper recognition settings
Section [001]†:[5] OFF = Tamper recognition disabled (default)
[5] ON =Tamper recognition enabled
†= DG457 only
Test Mode
To test the GlassTrek detector you must enter test mode and
use a TestTrek unit (459).
1. With the TestTrek unit (V2.0 or higher) within 2.5m (8ft) of the
GlassTrek, hold the test button down. A series of beeps is
produced which signals the GlassTrek to enter test mode.
You can also enter 123 in section [002], or remove and
replace Jumper J1.
2. The red and green LEDs illuminate for 5 seconds, followed
by an intermittent flashing of the red LED to indicate it is in
test mode. GlassTrek will exit test mode after approximately
3 minutes.
3. Place the TestTrek unit near the protected window and then
press the red “push” button on the TestTrek unit. A beep is
produced.
Red + Green LED = Test OK
The GlassTrek has detected the signal and generated an
alarm.
Green LED only = Test Failed
Perform another test by carefully striking the protected
surface with a cushioned tool. If both LEDs still do not
illuminate, increase the sensitivity of the GlassTrek detector,
or re-position the GlassTrek detector, or the room may be too
large to support the GlassTrek detector.
Voltage
Meter†
Used for trouble-shooting, the voltage meter indicates the
GlassTrek’s input voltage.
Enter section [900]. The 3-digit number that appears on the
screen represents input voltage x 10 (e.g. [133] = 13.3V).
† = DG457 only
Technical Specifications.
Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the website
www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions.
© 2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of
the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.
GlassTrek, Digiplex, Digiplex EVO, Magellan and Spectra SP are trademarks or registered trademarks of Paradox Security
Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Figure 1: Detection Angle
Figure 2: Connections
Figure 3: Exploded View
Voltage 9 - 16Vdc
Current DG457 (35mA) 457(25mA)
Coverage High: 9m (30ft) / Low: 4.5m (15ft)
Size 9cm (3.5in) x 6.6cm (2.6in) x 2.5cm (1in)
Weight 100g (4oz)
Alarm output 150mA, 28VDC, Form A (N.C.) / via combus
Anti-tamper output 150mA, 28VDC, Form A (N.C.) / via combus
Operating temp. -20°C to 50°C (4°F to 122°F)
Processing 1. Attack rise time
2. Attack sound pressure level
3. 7-band audio spectrum analysis
4. Envelope duration
5. Infra-sound
Microprocessor type 12/8-bits
Compatibility All Digiplex series (DGP/DGPNE) and all EVO
series control panels.
Testing tool TestTrek (DG459)
Certification (i.e. CE, UL) For updated information, visit www.paradox.com
A- Top View
B- Optimal Detection
Angle View
C- Side View
D- Optimal Detection
Angle View
B
A
D
C
Power Input
(9-16Vdc)
Combus*
(J3 ON)
Alarm relay
(N.O.
Optional*)
Anti-tamper
Jumpers
J1
J2
J3
* = DG457 only
J1
J2
J3
B
A
A- Opening pin
B- Screw hole
C- Side wire entry
D- Rear wire entry
E- PCB clip
B
C
D
E
PCB
Front Cover

Other manuals for DG457

2

This manual suits for next models

1

Other Paradox Security Sensor manuals

Paradox NV37M User manual

Paradox

Paradox NV37M User manual

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox NV780MX User manual

Paradox

Paradox NV780MX User manual

Paradox NV37MX User manual

Paradox

Paradox NV37MX User manual

Paradox NVR35M User manual

Paradox

Paradox NVR35M User manual

Paradox Digigard DG75 User manual

Paradox

Paradox Digigard DG75 User manual

Paradox DG85W User manual

Paradox

Paradox DG85W User manual

Paradox NV500 User manual

Paradox

Paradox NV500 User manual

Paradox SR230 User manual

Paradox

Paradox SR230 User manual

Paradox Magellan PMD75 User manual

Paradox

Paradox Magellan PMD75 User manual

Paradox Paradome DG467 User manual

Paradox

Paradox Paradome DG467 User manual

Paradox PMD85 User manual

Paradox

Paradox PMD85 User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox ENVY NVX80 User manual

Paradox

Paradox ENVY NVX80 User manual

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox Magellan PMD75 User manual

Paradox

Paradox Magellan PMD75 User manual

Paradox NV35MX User manual

Paradox

Paradox NV35MX User manual

Paradox NV5 User manual

Paradox

Paradox NV5 User manual

Paradox NV35M User manual

Paradox

Paradox NV35M User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox TM50 Touch User manual

Paradox

Paradox TM50 Touch User manual

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Popular Security Sensor manuals by other brands

Siemens DB110 Installation

Siemens

Siemens DB110 Installation

Abexo P41 Assembly and use instructions

Abexo

Abexo P41 Assembly and use instructions

RLE Technologies SD Series quick start guide

RLE Technologies

RLE Technologies SD Series quick start guide

Johnson Controls F62AA Installation Sheets Manual

Johnson Controls

Johnson Controls F62AA Installation Sheets Manual

SGB DLR-P CV Series Documentation

SGB

SGB DLR-P CV Series Documentation

Theben theRonda P360-110 DALI UP WH manual

Theben

Theben theRonda P360-110 DALI UP WH manual

S+S Regeltechnik KINASGARD DBWF Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik KINASGARD DBWF Operating Instructions, Mounting & Installation

YASKAWA MOTOMAN DX100 instructions

YASKAWA

YASKAWA MOTOMAN DX100 instructions

V-GREAT VG-6611S Installation and operation manual

V-GREAT

V-GREAT VG-6611S Installation and operation manual

Texecom Impaq SC-W installation manual

Texecom

Texecom Impaq SC-W installation manual

Halma apollo REACH Commissioning Guide

Halma

Halma apollo REACH Commissioning Guide

GEZE GC 363 R operating instructions

GEZE

GEZE GC 363 R operating instructions

F&F DRL-60-12 manual

F&F

F&F DRL-60-12 manual

König Electronic SEC-CA10 manual

König Electronic

König Electronic SEC-CA10 manual

jablotron JA-158P quick start guide

jablotron

jablotron JA-158P quick start guide

EMS FireCell FCX-170-001 installation guide

EMS

EMS FireCell FCX-170-001 installation guide

Niko 350-41659 manual

Niko

Niko 350-41659 manual

Philips EasyAir SNS212 MC Design-in guide

Philips

Philips EasyAir SNS212 MC Design-in guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.