NV5 Installation Instructions
NV5-EI02 - 09/2019
Please read all installation instructions before installing the unit.
Figure 1: NV5 Back Plate
1. Select detector location using Figure 2 as a guide. The detector must be installed at
2.1m (7.0 ft) or higher.
Figure 2: Beam Pattern
2. Loosen the locking screw (9), located at the bottom of the unit.
3. Separate the front cover from the back plate.
4. Separate the PCB board from the back plate
5. On the back plate drill holes for the wire pass-thru (2) and appropriate knockou t hol es.
For wall mount drill holes (3), (10) and (15).
For corner mount drill holes (5), (7), (12) and (14).
For bracket mount drill hole (4).
6. Secure back plate to surface.
For wall mount, pass wires through hole (2) of the back plate and secure with screws at
(3), (10) and (15).
For a corner mount, pass wires through hole (2) of the back plate and secure with
screws at (5), (7), (12) and (14).
Figure 3: SB100 Bracket Assembly Installation
For bracketed ceiling mount (with SB100), insert ceiling accessory (21) and orient as
per (23). Insert the Bracket Retainer (25).Pass wire from ceiling through(25),through
(17) and through hole (2) of the back plate. Secure bracket to ceiling with screws at
(16). Secure back plate with a screw at (4) onto bracket at (18).
For bracketed wall mount (with SB100), insert wall accessory (22) and orient as per
(24). Pass wire from wall through (25), through (20) and through hole (2) of the back
plate. Secure bracket to wall with screws at (16) Secure back plate with a screw at (4)
onto bracket at (19).
7. Snap the PCB board onto the back plate.
8. Connect wires to terminal board (1) as per Figure 4.
Figure 4: Terminal Board Wiring
Callout Description
16 Bracket mounting holes
17 Wire pass-thru (ceiling)
18 Ceiling mount
19 Wall mount
20 Wire pass-thru (wall)
21 Ceiling Accessory
22 Wall Accessory
23 Ceiling Accessory
Orientation
24 Wall Accessory Orientation
25 Bracket Retainer
ALARM OUTPUT
N.C. COM BLK RED TAMPER
12 Vdc N.C.
Callout Description
1 Terminal board
2 Wire pass-through
3 Wall mount (knockout)
4 Bracket mount (knockout)
5 Corner mount (knockout)
6 Trimpot (sensitivity 1-5)
7 Corner mount (knockout)
8 Tamper switch
9 Locking screw
10 Wall mount (knockout)
11 Sensor
12 Corner mount (knockout)
13 Jumpers (profile/LED)
14 Corner mount (knockout)
15 Wall mount (knockout)
NV5-EI02 - 09/2019
9. Adjust jumpers (13) for profiles (1-4) and LED ON / OFF (of an alarm) using this table:
10. Configure sensitivity via trimpot (6), default setting = 3.
Adjust from 1 (8m / 26.3 ft), 2 (9m / 29.5 ft), 3 (10m / 32.8 ft), 4 (11m / 36.1 ft),
5 (12m /39.4 ft).
Turn the trimpot clockwise to increase sensitivity.
Turn the trimpot counterclockwise to decrease sensitivity.
Warning: The sensitivity trimpot is fragile. Do not over torque.
11. Install front cover onto back plate.
12. Secure front cover to back plate with locking screw (9).
13. Perform power up sequence.
LED and relay will toggle on / off for 4 seconds.
Sensitivity level indication: The LED flashes 1 to 5 times to indicate trimpot position.
Jumper setting indication: The LED flashes 1 to 4 times to indicate jumper setting.
Total power-up sequence = 10 seconds.
Detector is ready for alarm detection. During alarm the LED is ON for 3 seconds (if set).
Recommendations:
Do not install in areas with large temperature fluctuations as caused by direct sunlight, or
heating / cooling equipment.
Do not install where airflow changes can cause objects to move into the detector path.
Do not install where dust or residue can accumulate onto the detector.
Do not install in areas with pets weighing more than 16 kg (35 lbs).
Notes:
The mirror option is pre-installed when ordered (no installation is necessary).
The SB100 bracket assembly is optional and can be installed for a ceiling or wall mount.
The sensor (11) does not require maintenance.
The tamper switch (8) is pressed down when the front cover is attached and closed
Legal:
Patents: One or more of the following US Patents 1,302,541 5,077,549 D680010 and other
patents pending may apply. Canadian and international patents may also apply.
Trademarks: ENVY Series is a trademark of Paradox Security Systems (Bahamas) Ltd. or
its affiliates in Canada, the United States and/or other countries.
Certification: For the latest information on products approvals, visit www.paradox.com.
Warranty: For complete warranty information on this product please refer to the Limited
Warranty Statement found on the website www.paradox.com/terms.
© 2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may
change without prior notice.
Profile #
(LED
Flashes)
Profile
Name
Interference
Level (APSP)
Processing
Type (EDGE)
JUMPER SETTINGS
LED ON LED OFF
1 Normal Normal* Single*
2 Moderate Normal Dual
3 Pet resistant High Single
4 Harsh High Dual
The NV5 features 4 pre-programmed profile settings. The number associated with
the profile (1 to 4) depicts the number of LED flashes when changing jumper
settings.
APSP: Set for the expected interference level of the environment (normal / high).
EDGE: The detector can be set to process for partially crossing the beam
(single) or for fully crossing the beam (dual) for increased detection
performance.
NORMAL: Use for normal environments that have minimal interference.
MODERATE: This profile provides better false alarm rejection.
PET RESISTANT: Set the Pet Resistant profile for pets that weigh up to 16 kg (35 lbs).
HARSH: Use the Harsh profile when the detector is installed in high-risk
environments (potential interference) and to provide greatly increased
false alarm immunity.
* Default Jumper Settings (APSP = Normal, EDGE = Single, LED = ON)
Technical Specifications
Installation height 2.1m – 3.1m (7.0 ft – 11.0 ft)
Current consumption 10.5 mA @ Standby / 11.3 mA @ Alarm
Power input 10 Vdc to 15 Vdc
Coverage 10m (32.8 ft) x 90°, 0.1 to 0.5m (0.3 to 1.6 ft) creep zone
Alarm output Solid State, N.C. 150 mA
Anti-tamper switch N.C. 28 Vdc, 0.15A
Operating temperature -10°C to 50°C (14°F to 122 °F) at 95% max. humidity
Dimensions 9.1 x 5.5 x 4 cm (3.5 x 2.2 x 1.6 in.)
RF Immunity EN 50130-4: 10V/m 80 MHz to 2 GHz
Standards EN 50131-2-2 Security Grade 2 / Environmental Class I
*

Other Paradox Security Sensor manuals

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox NV75M User manual

Paradox

Paradox NV75M User manual

Paradox ENVY NVX80 User manual

Paradox

Paradox ENVY NVX80 User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox PMD85 User manual

Paradox

Paradox PMD85 User manual

Paradox NV37M User manual

Paradox

Paradox NV37M User manual

Paradox EB-N94 User manual

Paradox

Paradox EB-N94 User manual

Paradox WD1 User manual

Paradox

Paradox WD1 User manual

Paradox TM50 Touch User manual

Paradox

Paradox TM50 Touch User manual

Paradox NVR35M User manual

Paradox

Paradox NVR35M User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Paradox Omnia OMN-PMD1 User manual

Paradox

Paradox Omnia OMN-PMD1 User manual

Paradox DG85W User manual

Paradox

Paradox DG85W User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Paradox NVR35M User manual

Paradox

Paradox NVR35M User manual

Paradox SR230 User manual

Paradox

Paradox SR230 User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox MAGELLAN MG-PMD75 User manual

Paradox

Paradox MAGELLAN MG-PMD75 User manual

Paradox NV35MX User manual

Paradox

Paradox NV35MX User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox NV37MR User manual

Paradox

Paradox NV37MR User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox Omnia OMN-PMD1 User manual

Paradox

Paradox Omnia OMN-PMD1 User manual

Popular Security Sensor manuals by other brands

System Sensor B224BI-WH Installation and maintenance instructions

System Sensor

System Sensor B224BI-WH Installation and maintenance instructions

DSC LC-104PIMW installation instructions

DSC

DSC LC-104PIMW installation instructions

PCB Piezotronics W138A51/-0003 Installation and operating manual

PCB Piezotronics

PCB Piezotronics W138A51/-0003 Installation and operating manual

Pentatech FD 01 Operating and safety instructions

Pentatech

Pentatech FD 01 Operating and safety instructions

STEINEL sensIQ S Information

STEINEL

STEINEL sensIQ S Information

Axis FA4090-E installation guide

Axis

Axis FA4090-E installation guide

Tavool TH250 quick start guide

Tavool

Tavool TH250 quick start guide

Wenglor SG4-I operating instructions

Wenglor

Wenglor SG4-I operating instructions

S+S Regeltechnik RHEASGARD KLGF Series Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik RHEASGARD KLGF Series Operating Instructions, Mounting & Installation

Orbit OSLPIR240B manual

Orbit

Orbit OSLPIR240B manual

System Sensor WFDNA Series Installation and maintenance  instruction

System Sensor

System Sensor WFDNA Series Installation and maintenance instruction

ratiotec Soldi 185 user manual

ratiotec

ratiotec Soldi 185 user manual

Philips EasyAir SNS212 MC Design-in guide

Philips

Philips EasyAir SNS212 MC Design-in guide

Sperian Miller Stretcher Picture guide

Sperian

Sperian Miller Stretcher Picture guide

Interlogix DC428 Operation and installation manual

Interlogix

Interlogix DC428 Operation and installation manual

Rittal DK 7030.440 Assembly and operating instructions

Rittal

Rittal DK 7030.440 Assembly and operating instructions

Protector WA-5 operating instructions

Protector

Protector WA-5 operating instructions

Powerfix KH 3236 operating instructions

Powerfix

Powerfix KH 3236 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.