PARADOX.COM
Wireless Outdoor/Indoor
Dual Band
Window and Sliding Door
Dual Detector with
Anti-Masking and
Pet Immunity
NVR35M-EI01
General Description NVR35M
Thank you for choosing the NVR35M Wireless for your professional
protection needs. The NVR35M wireless Dual Band version will provide you
the most advanced window and sliding doors protection either in Pet
Immune or Sharp mode. If you have any comments please write to us at
Paradox.com/products/feedback.
Installing the NVR35M
1. Remove the front cover - open the Captive screw.
2. Remove the Main Unit: open the two snap-lock mechanisms on each
side of the back cover attaching the Main Unit to the back cover as
displayed below. Then remove the Main Unit.
3. Pull the wires from the control panel through the knockout holes and
mount the back cover onto the window frame or wall using screws..
4. Attach the Main Unit to the back cover - ensure the locks snap closed.
5. Insert two AA batteries.
6. Set the following Detector settings according to requirements.
Figure 6 – Detector Settings
The following table displays the Dip Switch settings.
Table 1: DIP Switch Functionality
* For USA and Canada: 433MHz frequency is set by the manufacturer and
cannot be modified.
7. Replace the front cover and close the Captive screw.
Warning: Do not obscure the detector's field of view.
Testing the NVR35M
Perform a Walk-Test to test successful installation: Walk slowly across the
far end of the detection range and ensure detection.
Walk test mode lasts 5 minutes after the tamper screw is closed.
Figure 1 – Removing the Front Cover Figure 2 – Main Unit
Figure 3 – Removing the Main Unit
Figure 4 – Mounting the Back Cover
Front cover
Captive screw
Mounting
screw 1
Mounting
Tamper
screw 2
Tamper
knockout
hole
Knockout
holes
Figure 5 – Attaching the Main Unit
Dip Switch
Number Function Mode Description
1LED
ON: LED on (default)
OFF: LED off
2PET Immunity/
SHARP Mode
ON: PET Immunity mode (default)
OFF: SHARP mode
3* RF
ON: 433.92 MHz * (default)
OFF: 868.35 MHz- applicable for EU
versions only
123
DIP
Switches
Default Sensitivity level: 2
LED flashes green 1-3 times
according to the selected level.
Sensitivity Trimmer
NVR35M
Installation Manual V1.0
All manuals and user guides at all-guides.com
all-guides.com
PARADOX.COM
Beam Pattern
PET Mode
SHARP Mode
Top View
LED Display
Technical Specifications
Notification
Changes or modifications to this equipment not expressly approved by the
party responsible for compliance - Paradox Security Systems (Bahamas)
Ltd., could void the user’s authority to operate the equipment.
Warranty
The Limited Warranty Statement found on the website www.paradox.com/
terms.
Your use of the Paradox product signifies your acceptance of these terms
and conditions.
Patents
The following US patents may apply 5,886,632 and 6,215,399. Other
Canadian and international patents may apply.
Printed in Canada 05/2015.
Feature LED Status Indicator
Tamper open Green: ON for 0.3 seconds every 30
seconds
PIR sensitivity level setting Green: Flashes 1-3 times according to
the selected level
Alarm detection Red: ON for 2 seconds
Booting/Tamper close Green/Red alternating flashes for 30
seconds
Anti-mask detection Orange: Flashes ON/OFF 3 times every
60 seconds
Model Number NVR35M
Infrared sensor type 2 dual elements
Detection range • PET Immunity mode: 7.5m x 2m
(25 x 7 ft)
• Sharp mode: 10 x 2m (33 x 7 ft)
Super Pet Immunity Pet size approximately 50cm
Anti- mask Active IR detection for blocking 30cm and
sprayed liquid
Input voltage 3VDC=2 x1.5VDC AA Alkaline batteries
Current consumption 40μA in Standby
30mA in Alarm/RF Transmitting
Battery life 3 years of typical use
Low battery voltage
Signal
2.5V
Compatibility RTX3 and Magellan systems
Outdoor protection IP54
Operation temperature -35°c: +50°c
Relative humidity 95% non-condensing
RF Frequency Dual Band: 433.92 MHz /868.35 MHz
IMPORTANT: For US and Canada, only 433.92
MHz is used
Dimensions 12.3 x 6.1 x 4.3 cm (4.8 x 2.4 x 1.7 in.)
Certifications CE, EN50131-2-2 Grade 2, Class IV
Weight 100g / 0.2 lb
All manuals and user guides at all-guides.com

Other Paradox Security Sensor manuals

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox NV780MX User manual

Paradox

Paradox NV780MX User manual

Paradox NV780 User manual

Paradox

Paradox NV780 User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox NV35MX User manual

Paradox

Paradox NV35MX User manual

Paradox DCT6 User manual

Paradox

Paradox DCT6 User manual

Paradox NV37MX User manual

Paradox

Paradox NV37MX User manual

Paradox ESPRIT728 Operating instructions

Paradox

Paradox ESPRIT728 Operating instructions

Paradox ENVY NVX80 User manual

Paradox

Paradox ENVY NVX80 User manual

Paradox Digigard DG75 User manual

Paradox

Paradox Digigard DG75 User manual

Paradox EB-N94 User manual

Paradox

Paradox EB-N94 User manual

Paradox Paradome DG467 User manual

Paradox

Paradox Paradome DG467 User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox Magellan PMD75 User manual

Paradox

Paradox Magellan PMD75 User manual

Paradox SR230 User manual

Paradox

Paradox SR230 User manual

Paradox SR230 User manual

Paradox

Paradox SR230 User manual

Paradox NV500 User manual

Paradox

Paradox NV500 User manual

Paradox NV75MR User manual

Paradox

Paradox NV75MR User manual

Paradox Omnia OMN-PMD1 User manual

Paradox

Paradox Omnia OMN-PMD1 User manual

Paradox PMD85 User manual

Paradox

Paradox PMD85 User manual

Paradox NV75MW User manual

Paradox

Paradox NV75MW User manual

Paradox NV37MR User manual

Paradox

Paradox NV37MR User manual

Popular Security Sensor manuals by other brands

Honeywell FlexGuard FG-1625F installation instructions

Honeywell

Honeywell FlexGuard FG-1625F installation instructions

Syrinix PIPEMINDER T Technical manual

Syrinix

Syrinix PIPEMINDER T Technical manual

Leuze LCS Series manual

Leuze

Leuze LCS Series manual

B.E.G. Luxomat BL4 operating manual

B.E.G.

B.E.G. Luxomat BL4 operating manual

Electro Detectors EDA-D5000 installation instructions

Electro Detectors

Electro Detectors EDA-D5000 installation instructions

Bacharach H-10PA manual

Bacharach

Bacharach H-10PA manual

Bosch D-tect 120 Professional Original instructions

Bosch

Bosch D-tect 120 Professional Original instructions

Inficon E-Check Translation of the original operating instructions

Inficon

Inficon E-Check Translation of the original operating instructions

Dragon Wholesaling DFD30 Operation instructions

Dragon Wholesaling

Dragon Wholesaling DFD30 Operation instructions

STEINEL PROFESSIONAL IR Quattro KNX operating instructions

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IR Quattro KNX operating instructions

DELTA DORE DMF Tyxal+ quick start guide

DELTA DORE

DELTA DORE DMF Tyxal+ quick start guide

Niko Swiss Garde 360 Presence DALI Secondary... installation instructions

Niko

Niko Swiss Garde 360 Presence DALI Secondary... installation instructions

Xylem wtw CN 800 DIN operating manual

Xylem

Xylem wtw CN 800 DIN operating manual

GROUNDTECH Evo user manual

GROUNDTECH

GROUNDTECH Evo user manual

Draminski MD2 manual

Draminski

Draminski MD2 manual

THORLABS PDAPC2 user guide

THORLABS

THORLABS PDAPC2 user guide

Inficon Ecotec E3000 Original operating instructions

Inficon

Inficon Ecotec E3000 Original operating instructions

MKS Ophir FPD-IG-25 quick reference

MKS

MKS Ophir FPD-IG-25 quick reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.