Parker SNPT4-B-4M Series User manual

Wireless Sensors
SNPT4-XXX-B-4MX-XXX
Operating Instructions
ID: 2ACDM-SNG4
IC: 11983A-SNG4

Operating Instructions for Wireless Sensors SNPT4-XXX-B-4MX-XXX
Outside the EU:
Parker Hannifin Corporatio
Quick Coupling Division
8145 Lewis Road
Minneapolis, MN 55427 USA
In the EU:
Parker Hannifin Manufacturing Germany GmbH & Co. K
High Pressure Connectors Europe
Am Metallwerk 9, 33659 Bielefeld
Version Date Revision
1.3 English 07/2023 Second edition
The information in this document may not be reproduced and distribu-
ted in whole or in part without the express permission of Parker Hannifin
Corporation.
All registered logos and trademarks mentioned and used in this docu-
ment, including those protected by third parties, are subject without
restrictions to the provisions of applicable trademark law as well as the
rights of ownership by the registered owner.
© Copyright 2023, Parker Hannifin Corporation.All rights eserved.

Table of contents
About these operating instructions..................................1
1. Description of the device.............................................3
2. Safety information ........................................................4
2.1 Intended use ...........................................................5
2.2 Technical personnel ................................................6
3. Construction and operation.........................................7
3.1 Operation ................................................................8
3.2 LED status (sensor not connected) .........................8
3.3 LED status (sensor connected) ...............................9
3.4 Broadcast Mode .....................................................9
3.5 Connected Mode ..................................................10
4. Changing the battery..................................................10
Page

5. Switching the sensor on.............................................11
6. Switchingthesensoro ............................................11
7. Connecting the sensor to the
Voice of the Machine
Mobile App ..................................................................12
8. Troubleshooting ..........................................................13
9. Maintenance and cleaning.........................................14
10. Technical data .............................................................15
10.1 Dimensional drawings ...........................................18
10.2 Directives ..............................................................24
FCC Disclaimer.................................................................25

V1.3/07/23
About these operating instructions
1
ENGLISH
About these operating instructions
Carefully read the associated instructions prior to each
step and follow the specified o der.
Read section “Safety information” on page 4
especially carefully and follow the instructions.
About these operating instructions

V1.3/07/23
About these operating instructions
2
ENGLISH
Danger signs and symbols used
NOTE
The symbol identifies a danger that can cause
property damage.
►Follow the instructions to avoid dangers!
This symbol identifies a danger p esent when
handling the SensoNODE Blue diagnostic sensor.
►Follow the instructions to avoid the dangers!
You can find a c oss-reference to other sections,
documents or sources here.
■Lists are found here.
►Handling instructions are found here.
1Handling steps are found here.
Responses are found here.
About these operating instructions

V1.3/07/23
1. Description of the device
3
ENGLISH
1. Description of the device
The SensoNODE Blue diagnostic sensor, called sensor in the
following, is used to measure pressures and temperatures. The
sensor is approved for the pressures and temperatures listed in
the technical data ( “Technical Data” on page 23).
Scope of delivery and accessories
Check the delivery of accessories for completeness.. If
something is missing, contact your sales representative.
■SensoNODE Blue Sensor
■SensoNODE Blue Sensor Operating Instructions
Description of the device

V1.3/07/23
2. Safety information
4
ENGLISH
2. Safety information
Before you work with the sensor , read and heed the information
in these operating instructions. Failure to follow the instructions
provided, especially the safety information, can pose a danger to
humans, the environment, and other equipment.
The sensor represents the state of the art in terms of accuracy,
operating principle as well as safe and reliable operation.
Comply with existing national regulations for
accident prevention and safety at the workplace
when working!
Note the IP protection rating when using the sensor
in what areas ( “Technical Data” on page 23)!
Allow only trained technical personnel to install
the sensor!
Comply with the specified tightening to ques!
Do not apply any force to the sensor!
Never use a damaged or defective sensor!
Safety information

V1.3/07/23
2. Safety information
5
ENGLISH
2.1 Intended use
The sensor has been designed for measurement of
pressure and temperature in the approved ranges
( “Technical Data” on page 23) .
The sensor is intended solely for use with the Voice of
the Machine mobile app.
Any other application beyond the above use of the sensor is
prohibited, can result in accidents or destruction of the sensor
and immediately voids any and all warranty claims against the
manufacturer.
Misuse
The sensor does not comply with Directive 2014/34/
EU and for this reason may not be used in potentially
explosive atmospheres.
Safety information

V1.3/07/23
2. Safety information
6
ENGLISH
2.2 Technical personnel
These operating instructions are intended for trained technical
personnel who are familiar with the applicable regulations and
standards in the field of application. The technical personnel
entrusted with commissioning and operating the device must
have suitable qualifications. The qualifications can be acquired
in the form of training or appropriate instruction.
The technical personnel must be familiar with the content of
these operating instructions, which must be accessible at all
times.
Safety information

V1.3/07/23
3. Construction and operation
7
ENGLISH
Construction and operation
3. Construction and operation
a. Cover
b. Antenna
c. Sensor
d. Battery cover screws
e. LED
f. POWER button
b
f
d
a
e
c

V1.3/07/23
3. Construction and operation
8
ENGLISH
3.1 Operation
The installation of the sensor into an existing plant system will
measure and provide the current pressure value. The measured
data is sent to a mobile device via Bluetooth with the Voice of
the Machine mobile app ( “Connecting the sensor to the
Voice of the Machine mobile app” on page 12). The LED
indicates the current task being carried out by the sensor.
3.2 LED status (sensor not connected)
Red Green Blue: Startup sequence. After several
repetitions, the battery will drain and need to be replaced
( “Changing the battery” on page 10).
Blue flashing: Sensor looking for a connection
Construction and operation
3.1 Operation
The installation of the sensor into an existing plant system will
measure and provide the current pressure value. The measured
data is sent to a mobile device via Bluetooth with the Voice of
the Machine mobile app ( “Connecting the sensor to the
Voice of the Machine mobile app” on page 12). The LED
indicates the current task being carried out by the sensor.
3.2 LED status (sensor not connected to app)
Red Green Blue: Startup sequence. This will
change to just blue flashing
Note: if this keeps repeating after startup, the battery is low and
needs to be replaced ( “Changing the battery” on page 10).
Blue flashing: Sensor looking for a connection
Gen2 generation sensors will continue the blue flashing while in
unconnected state.
Gen4 newest generation of SensoNODE, after approximately
1 minute the LED will change from the flashing blue LED to
now mimic the Connected Mode LED status to provide a visual
indication of the sensor measurement value (see page 9).

V1.3/07/23
3. Construction and operation
9
ENGLISH
Construction and operation
3.3 LED Status (Connected Mode)**
Green (single brief flash) - Sensor measurement -
Sensor reading between 0% and 25% of span.
Yellow (single brief flash) - Sensor measurement -
Sensor reading between 25% and 50% of span.
Orange (single brief flash) - Sensor measurement -
Sensor reading between 50% and 75% of span.
Red (single brief flash) - Sensor measurement - Sensor
reading between 75% and 100% of span.
3.4 Broadcast Mode
■The sensor is always available.
■The sensor will be displayed on several devices.

V1.3/07/23
4. Changing the battery
10
ENGLISH
3.5 Connected Mode
■The sensor will be displayed on only one
connected device.
■Bidirectional communication with the connected
device will allow the adjustment of settings and
recording of measurements.
4. Changing the battery
1 Remove the screws from the battery cover (d).
2 Remove the cover (a).
3 Remove the old battery.
4 Insert new battery (CR123A or
Parker QX-008-121).
5 Replace the cover (a).
6 Tighten the screws in the battery cover (d).
The battery has been replaced.
Changing the battery

V1.3/07/23
5. Switching the sensor on
11
ENGLISH
Switching the sensor on
5. Switching the sensor on
1 Press the POWER button.
Sensor starts automatically when a battery is
inserted.
6. Switching the sensor off
1 Press and hold the POWER button for 3 seconds.
The LED lights up red for 3 seconds .
The LED flashes orange.
The LED flashes red.
The sensor is switched off

V1.3/07/23
7. Connecting the sensor to the Voice of the Machine Mobile App
12
ENGLISH
7. Connecting the sensor to the
Voice of the
Machine
Mobile App
The Voice of the Machine mobile app can be downloaded to
your mobile device from the App Store or Google™ play.
1 Download the Voice of the Machine
mobile app to the mobile device.
2 Switch on Bluetooth on the mobile device.
3 Open the Voice of the Machine mobile app.
4 Tap the “OK” button.
5 Allow access.
6 Tap the “+” button.
7 Tap the desired sensor.
8 Tap the “Add” button.
The sensor and the Voice of the Machine mobile
app are connected.
Connecting the sensor to the Voice of the Machine Mobile App

V1.3/07/23
8. Troubleshooting
13
ENGLISH
Troubleshooting
8. Troubleshooting
NOTE
Risk of material damage from unprofessionally
performed repair.
►Open the sensor only to replace the battery!
►Never attempt to make repairs yourself!
►In the event of a defect, return the sensor to
the manufacturer!

V1.3/07/23
9. Maintenance and cleaning
14
ENGLISH
9. Maintenance and cleaning
Maintenance
The sensor is maintenance-free and cannot be repaired by the
user. In the event of a defect, the sensor must be returned to
the manufacturer for repair.
Cleaning
Use a dry or lightly moistened, lint-free cloth to clean the outer
surfaces of the sensor.
NOTE
Risk of material damage from aggressive and
chemically etching substances.
►Never use abrasive or volatile cleaners!
►Do not use sharp objects or
aggressive cleaners!
Maintenance and cleaning

V1.3/07/23
10. Technical Data
15
ENGLISH
Technical Data
11. Technical Data
Property SNPT2-1-B-4MP
SNPT2-10-B-4MP
Material Polycarbonate Polycarbonate
Material of media
contacting parts
17-4 Stainless steel
and nitrile rubber
17-4 Stainless steel
and nitrile rubber
Pressure range -14.5 ...+14.5 psi 0...150 psi
Max. gauge pressure 29 psi 225psi
Burst pressure 3x full scale 4x full scale
Accuracy (at 25°C) ± 1.5% of full scale ± 1.5% of full scale
Response time 1s 1s
Storage temperature -20...+70°C -20...+70°C
Media temperature -40...+85°C -40...+85°C
Max. Number of
measuring cycles > 1million > 1million
Battery CR123A CR123A
Protection class IP65 (EN60529) IP65 (EN60529)
10. Technical Data
SNPT4-1-B-4MP SNPT4-10-B-4MP

V1.3/07/23
10. Technical Data
16
ENGLISH
Technical Data
Property SNPT2-100-
B-4MO
SNPT2-250-
B-4MO
Material Polycarbonate Polycarbonate
Material of media
contacting parts
17-4 Stainless steel
and nitrile rubber
17-4 Stainless steel
and nitrile rubber
Pressure range 0...1500 psi 0...3625 psi
Max. gauge pressure 2250 psi 5440 psi
Burst pressure 3x full scale 4x full scale
Accuracy (at 25°C) ± 1.5% of full scale ± 1.5% of full scale
Response time 1s 1s
Storage temperature -20...+70°C -20...+70°C
Media temperature -40...+85°C -40...+85°C
Max. Number of
measuring cycles > 1million > 1million
SNPT4-100-
B-4MO
SNPT4-250-
B-4MO
This manual suits for next models