EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PASCO
  6. •
  7. Measuring Instrument
  8. •
  9. PASCO SF-9568A User manual

PASCO SF-9568A User manual

Other PASCO Measuring Instrument manuals

PASCO PS-3230 User manual

PASCO

PASCO PS-3230 User manual

PASCO SF-9069 User manual

PASCO

PASCO SF-9069 User manual

PASCO PS-3229 User manual

PASCO

PASCO PS-3229 User manual

PASCO OS-7053 User manual

PASCO

PASCO OS-7053 User manual

PASCO SP-9285 User manual

PASCO

PASCO SP-9285 User manual

PASCO PS-3321 User manual

PASCO

PASCO PS-3321 User manual

PASCO OS-9171 User manual

PASCO

PASCO OS-9171 User manual

PASCO OS-8458 User manual

PASCO

PASCO OS-8458 User manual

PASCO PS-2600 Use and care manual

PASCO

PASCO PS-2600 Use and care manual

PASCO PS-3320 User manual

PASCO

PASCO PS-3320 User manual

PASCO PS-2136A User manual

PASCO

PASCO PS-2136A User manual

PASCO Pasport PS-2152 User manual

PASCO

PASCO Pasport PS-2152 User manual

PASCO PS-3521 User manual

PASCO

PASCO PS-3521 User manual

PASCO PS-3238 User manual

PASCO

PASCO PS-3238 User manual

PASCO SF-9500A User manual

PASCO

PASCO SF-9500A User manual

PASCO PS-3215 Use and care manual

PASCO

PASCO PS-3215 Use and care manual

PASCO TD-8564 User manual

PASCO

PASCO TD-8564 User manual

PASCO Wireless Smart Gate User manual

PASCO

PASCO Wireless Smart Gate User manual

PASCO PS-3234 User manual

PASCO

PASCO PS-3234 User manual

PASCO PASPORT PS-2174 User manual

PASCO

PASCO PASPORT PS-2174 User manual

PASCO ES-9077 User manual

PASCO

PASCO ES-9077 User manual

PASCO OS-8458B User manual

PASCO

PASCO OS-8458B User manual

PASCO OS-8527A User manual

PASCO

PASCO OS-8527A User manual

PASCO PASPort PS-2128 User manual

PASCO

PASCO PASPort PS-2128 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Instruction Sheet
for the PASCO
Model SF-9568A
012-08015A
8/01
Introduction
The PASCO Model SF-9568A Student Voltmeter is a
rugged yet sensitive instrument, designed specifically for
student experiments. It has three ranges and is switch
selectable by input jack to measure AC and DC values.
Operation
To zero the meter:
Place the meter in the position (vertical or horizontal)
in which it will be used. Disconnect the meter. Use a
small, standard blade screwdriver to turn the Zero Adjust
Screw (located on the case, below the meter) until the
meter needle is aligned with the zero on the scale.
➤NOTE: If the meter is mechanically zeroed
in one position, and then the position is changed,
it may need to be zeroed again.
To measure voltage:
①Set the selection switch for AC or DC current. (The
AC setting will provide RMS (root mean square)
readings for alternating current circuits.)
Student Voltmeter
②Determine the range – For both AC and DC mea-
surements, voltage may be measured in one of
three ranges: 3, 15 and 30 Volts. The range is se-
lected by plugging test leads (not included) into the
appropriate input jack.
➤NOTE: To protect the meter, always choose a
range that is higher than the highest voltage you
might expect in the circuit.
③Attach leads to the circuit points between which
you wish to measure the voltage.
For AC measurements –
Plug one lead of the circuit into the black input jack
and the other into the red input jack of the appropri-
ate range.
For DC measurements –
Connect the leads in such a way that positive cur-
rent flows into the black (0) connector on the Volt-
meter .
➃Now you can read the voltage on the meter. A full
swing of the needle corresponds to the value in the
chosen range selection (i.e., On the 3 V range, a
reading of 20 on the upper scale indicates a voltage
of 2.0 volts.).
3
CE
30
15
0
V
SF-9568A
0
10
30
20
Voltmeter
Circuit
Direction of
positive
current flow
0
3 V
15 V
30 V
Zero Adjust
Screw
better
teach science
ways to
Phone (916) 786-3800 • FAX (916) 786-8905 • email: techsupp@PASCO.com
10101 Foothills Blvd. • P.O. Box 619011 • Roseville, CA 95678-9011 USA
®
012-08015A
2
Limited Warranty
PASCO scientific warrants this product to be free from
defects in materials and workmanship for a period of
one year from the date of shipment to the customer.
PASCO will repair or replace, at its option, any part of
the product which is deemed to be defective in mate-
rial or workmanship. This warranty does not cover
damage to the product caused by abuse or improper
use. Determination of whether a product failure is the
result of a manufacturing defect or improper use by the
customer shall be made solely by PASCO scientific.
Responsibility for the return of equipment for warranty
repair belongs to the customer. Equipment must be
properly packed to prevent damage and shipped
postage or freight prepaid. (Damage caused by
improper packing of the equipment for return shipment
will not be covered by the warranty.) Shipping costs
for returning the equipment, after repair, will be paid
by PASCO scientific.
To Reach PASCO
For technical support, call us at 1-800-772-8700
(toll-free within the U.S.) or (916) 786-3800.
fax: (916) 786-3292
e-mail: [email protected]
web: www.pasco.com
Specifications
Ranges (DC and AC): 0 to 3 V, 15 V and 30 V
Accuracy: ± 2% of full scale
Scale length: 6.2 cm
Sensitivity: 10kΩ/V
Frequency Response (AC): 20 Hz to 50 KHz, ± 3db
Impedance: 0-3 V 30 kΩ/V
0-15 V 150 kΩ/V
Schematic SF-9568A