1 50
4 digits 8 digits
1 sec 60 secs
11V DC 14V DC
170 mA
1 A
12V DC
-20 °C (-4 °F) +55 °C (+131 °F)
IPX7
K38 1 1/2in 3 in 1/2in
K50 2 in 4 in 5/8in
K75 3 in 5 1/2in 5/8in
Voltage
Switchable current
Specications
Operating temperature
Electrical
Environment
Dimensions
Min Max
Width Height Depth
Current
Outdoor Use
Features
Number of Codes
Code length
Door open time
Silent operation
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Exit button input
Door Contact input
Alarm/bell output voltage
Waterproof
Backlight
Cable length
Min Max
Min Max
Yes
Yes
Yes
Yes
No
3 yards
Yes
1 - Can I use a fail open release (e.g. Maglock)?
QThe lock wires from a compact keypad provide 12V DC to the electric lock. By default, the compact is set to operate with a fail
Qlocked release - providing 12V on the lock wires when a valid entry is made. To use a fail open release, the lock wire setting
Qneeds to be changed (Program option 1)
2 - Can I put a relay across the lock wire output?
QYes - All compact systems have been designed to drive relays.
3 - Integration with an entry phone system.
QThe output from the entry phone system is used to simulate an exit button for the Paxton equipment. No voltage should be
Qapplied to the exit input wires (Blue / Mauve) of a compact unit. Most phone systems will provide a powered pair to release the
Qdoor lock; this voltage must be used to drive an independent relay. The relay contacts must be 'normally open going closed' to
Qmimic a 'push to make' exit button. Only a voltage free output pair can be connected directly to the exit input wires.
4 - What are the keypad code types used for?
QNormal - Releases the door for the time period set in Option 5 ( 7 secs default)
QToggle - Releases the lock until the code is entered for a second time.
QDuress - Releases the lock (as in Normal) but also energizes the bell output for 30 seconds.
QDelete - Used to remove a specic code that has already been entered in Multiple mode.
5 - Connecting a compact with another control unit.
QThis cannot be done. Paxton Compact systems have the control electronics built in and no direct data output is provided.
QThe Switch2 and Net2 system use a dierent type of data input.
QNote: The compact system will control the door unit on its own.
6- Read in and read out on one door.
QYou cannot wire two compact systems in parallel to a common lock as this may result in damage to your system. They will both
Qpower the door lock independently and will not oer single point control. We recommend using one Switch2 controller with two
Qcompatible keypads or readers.
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
Vandal resistance Low