5300/5500 DOOR CLOSER MODELS
TOP JAMB INSTALLATION - PUSH SIDE - PIVOT STOP (PS) ARM APPLICATIONS
INSTRUCTION: 539356
REV.0 10-01-19
MACHINE SCREWS:
USE #7 OR 13/64" [5.1] DRILL AND 1/4-20 TAP
WOOD DOOR/FRAME SCREWS:
USE 5/32" [4] DRILL
SEX NUTS:
USE 3/8" [9.5] DRILL (CLOSER TO DOOR) PDQ Manufacturing
2230 Embassy Dr.
Lancaster, PA 17603
833-273-7832
833-2 PDQTECH
www.pdqlocks.com
C
L
HINGE
OR
PIVOT
1 3/4" [44.5]
1 7/8" [47.6]
12" [304.8]
3/4" [19.1]
1/2" [12.7]
A
BOTTOM OF FRAME FACE
Opening Dim. A Dim. B
85° 10-3/8" [263.5] 15-7/8" [403.2]
90° 9-3/4" [247.7] 15-1/4" [387.4]
95° 9-3/16" [233.4] 14-11/16" [373.1]
100° 8-11/16" [220.7] 14-3/16" [360.4]
105° 8-5/16" [211.1] 13-13/16" [350.8]
110° 7-15/16" [201.6] 13-7/16" [341.3]
NOTES:
1. DO NOT SCALE DRAWING. LEFT HAND DOOR SHOWN.
2. DIMENSIONS ARE GIVEN IN INCHES [MM].
3. FOR DOORS WITH REVEAL OF 4 INCHES. CONSULT FACTORY FOR OTHER REVEAL DEPTHS.
4. MINIMUM CEILING CLEARANCE FROM BOTTOM OF FRAME FACE FOR CLOSER : 2-11/16".
5. SEX NUTS REQUIRED FOR UNREINFORCED OR COMPOSITE FIRE DOORS.
6. DOOR AND FRAME MUST BE REINFORCED PER ANSI/SDI A250.8 REQUIREMENTS - MINIMUM THICKNESS
RECOMMENDED FOR REINFORCEMENTS IN HOLLOW-METAL DOORS AND FRAMES: 0.067" UNLESS OTHERWISE NOTED.
7. HOLLOW-METAL DOORS REQUIRE CHANNEL OR BOX-TYPE REINFORCEMENT WHEN SEX NUT MOUNT IS SPECIFIED.
B
DOOR WIDTH APPROX.
SIZE INTERIOR EXTERIOR 360° TURNS
BF 5 LBF ON 36" -- -8 (CCW)
1 32" [812.8] 28" [711.2] -6 (CCW)
2 36" [914.4] 32" [812.8] -4 (CCW)
3 42" [1066.8] 36" [914.4] 0 (PRESET)
4 48" [1219.2] 42" [1066.8] +5 (CW)
5 54" [1371.6] 48" [1219.2] +9 (CW)
6 58" [1473.2] 54" [1371.6] +12 (CW)
ADJUST SPRING POWER:
1. Use 4 mm hex key provided to adjust to size on chart.
Clockwise (CW) turns increase spring power (+).
Counter-clockwise (CCW) turns decrease spring power (-).
5300/5500 Series closers can be adjusted to meet
ADA Barrier Free (BF) applications. Compliance with ADA/BF
requirements may result with door not fully closing and latching.
Check with local AHJ. Closer size may vary due to site conditions.
LH RH
1. Confirm this sheet is correct for your product and application.
2. Read the complete instruction sheet before starting installation.
3. Incorrectly installed or adjusted door closers can cause
personal injury or property damage.
4. To ensure safe operation, door closers should be examined and
serviced regularly.
INSTALL CLOSER AND ARM:
1. Attach closer body to frame
face. Sweep and latch
valves point toward
hinge.
2. Attach foot to door.
SLOWER
FASTER
INCREASE
DECREASE
SWEEP SPEED
DELAYED
ACTION
BACKCHECK
CONTROL ADJUSTMENTS:
CRITICAL: For closer longevity, BACKCHECK
must be adjusted to significantly slow opening
of door before arm bottoms on stop.
Closing time of 3-7 seconds is typical.
More time may be needed for ADA/BF access.
Clockwise (CW) = SLOWER.
Counter-clockwise (CCW) = FASTER.
DO NOT REMOVE VALVES
1. Use hex key provided.
2. Adjust SWEEP (closing max.°- 10°).
3. Adjust LATCH (closing 10°- 0°).
4. Adjust BACKCHECK resistance (opening 70°- max.°).
DO NOT COMPLETELY CLOSE VALVE
5. Adjust (optional) DELAYED ACTION (closing max.°- 70°);
Provides additional hesitation for access (ADA/BF) through
door.
LATCH SPEED
CLOSING CYCLE
Y
A
L
E
D
E
E
W
S
P
H
C
T
A
L
MAX.°
K
C
A
B
C
E
H
C
K
N
E
P
O
I
N
G
OPENING CYCLE
MAX.°
PREPARE DOOR AND FRAME:
1. Determine proper opening angle.
2. Determine door hand (LH or RH).
3. Using template (see reverse
side), mark holes on door & frame.
3. Secure main arm to closer spindle 90° to door/frame.
4. Connect adjustment arm with foot assembly:
Rotate main arm until adjustment arm is 90° to door & frame.
Tighten arm screw or bolt .
CW
CCW
(-) (+)
SPRING
POWER/SIZE
ADJUSTING NUT
HEX
KEY
INSTALL COVER:
1. Slip cover over closer until flush with door face.
2. Wide Cover - Orient cover so cutout is at bottom of closer
body. Secure to closer with screw on each end.
Narrow Cover - Cover will snap into slots on closer
body. Install dust cap over top closer pinion.
NOTE: Sweep, latch, backcheck,
and optional delayed action valves
are all accessible after cover installation.
FULL COVER
SLIM
COVER
DUST
CAP
TOOLS REQUIRED:
1. Power drill
2. 10mm box/combo wrench
3. Phillips screw driver
4. #7 or 13/64" drill bit and
1/4-20 tap (metal screws)
5. Tap handle
6. 5/32" drill bit (wood screws)
7. 3/8" drill bit (sex nuts)
8. Center punch
NOTES:
1. See reverse side of this sheet to machine door & frame.
2. Dimensions based on 4-1/2" x 4-1/2" full mortise butt hinges
with 5/8" stop and 1/8" door gap.
3. Confirm door & frame are properly reinforced.
4. Sex nuts required for un-reinforced or composite fire doors.
5. Do not install closer on the exterior (weather) side of building.
1
2
3
4
5
6
7
8
PDQ Manufacturing
2230 Embassy Dr.
Lancaster, PA 17603
833-273-7832
833-2 PDQTECH
www.pdqlocks.com
5300/5500 DOOR CLOSER MODELS
TOP JAMB INSTALLATION - PUSH SIDE - PIVOT STOP (PS) ARM APPLICATIONS
INSTRUCTION: 539356
REV.0 10-01-19
CLOSER
BODY
FOOT
SWEEP & LATCH
VALVES
SPINDLE
ADJUSTMENT
ARM
FOOT
6
PRELOAD
TO 90°
ARM SCREW
OR BOLT
MAIN ARM
90°
CLOSER !

This manual suits for next models

1

Other PDQ Door Opening System manuals

PDQ 6300 User manual

PDQ

PDQ 6300 User manual

PDQ 3100 User manual

PDQ

PDQ 3100 User manual

PDQ 3100 User manual

PDQ

PDQ 3100 User manual

PDQ 3100 User manual

PDQ

PDQ 3100 User manual

PDQ 7101 User manual

PDQ

PDQ 7101 User manual

PDQ 3100 User manual

PDQ

PDQ 3100 User manual

PDQ 7101 User manual

PDQ

PDQ 7101 User manual

PDQ 5100 User manual

PDQ

PDQ 5100 User manual

PDQ 6EWS STS User manual

PDQ

PDQ 6EWS STS User manual

PDQ 5100 User manual

PDQ

PDQ 5100 User manual

PDQ 6300 User manual

PDQ

PDQ 6300 User manual

PDQ 6300M/MF User manual

PDQ

PDQ 6300M/MF User manual

PDQ DOOR CLOSER User manual

PDQ

PDQ DOOR CLOSER User manual

PDQ 5300 User manual

PDQ

PDQ 5300 User manual

PDQ 5300 User manual

PDQ

PDQ 5300 User manual

Popular Door Opening System manuals by other brands

Record C 127 SU S user manual

Record

Record C 127 SU S user manual

D+H ZA 35-HS instructions

D+H

D+H ZA 35-HS instructions

ECO Schulte ETS 42 Operator's manual

ECO Schulte

ECO Schulte ETS 42 Operator's manual

Assa Abloy Corbin Russwin PED4800 Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin PED4800 Series installation instructions

Dorma ED400 Installer manual

Dorma

Dorma ED400 Installer manual

ECO Schulte FSA ECO SR-EFR Assembly instruction

ECO Schulte

ECO Schulte FSA ECO SR-EFR Assembly instruction

ECO Schulte ECO SR-EF Assembly instruction

ECO Schulte

ECO Schulte ECO SR-EF Assembly instruction

Dormakaba ED100 Service manual

Dormakaba

Dormakaba ED100 Service manual

Assa Abloy RD3 user manual

Assa Abloy

Assa Abloy RD3 user manual

LCN 4020 Series installation instructions

LCN

LCN 4020 Series installation instructions

Dorma 8600 TDE manual

Dorma

Dorma 8600 TDE manual

Dormakaba ES 200 EASY PLUS operating manual

Dormakaba

Dormakaba ES 200 EASY PLUS operating manual

Optex Pro-Swing Premier Mk2 Specification manual

Optex

Optex Pro-Swing Premier Mk2 Specification manual

CAME F1000 installation manual

CAME

CAME F1000 installation manual

LCN 4412 HSA Installation instructions and operators manual

LCN

LCN 4412 HSA Installation instructions and operators manual

Fireco Freedor SmartSound Fitting and Operating Guide

Fireco

Fireco Freedor SmartSound Fitting and Operating Guide

SECO-LARM Enforcer SD-C141S installation manual

SECO-LARM

SECO-LARM Enforcer SD-C141S installation manual

Assa Abloy Norton 6000 Series Programming instructions

Assa Abloy

Assa Abloy Norton 6000 Series Programming instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.