6300 Series Full Feature Low Energy Operator
Models 6312, 6352 (Pull Side)
Installation Instructions
Pour la version francaise voir www.nortondoorcontrols.com.
READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
6352 Pull Side Double Egress Up to 130° opening (Right Hand Shown)
Double Egress
Pull Arm Pkg
(6350-1L (LH);
6350-1R (RH)
This product can expose you to lead which is known to the state of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65warnings.ca.gov.
WARNING
Tools Needed Supplied Fasteners
6312 Pull Side Up to 180° opening
1/4-20
#7
#2 and #3
10" or 12"
3/16"
1/2"
3/4"
Deep
Well
#16 12-24
Punch
3/16" 3/32"
Cover (6300COV)
End Cap Kit
(6300END)
Power Supply
(6300CM2)
Standard Pull Arm Pkg
(6310-1)
End Cap Kit
(6300END)
Backplate
Closer Body
(6300LAP)
Track
(7100-1T)
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21
2
6312/6352 Series (Pull Side) Power Operator
Technical Data
Input power: 120VAC, 60Hz 3.0A
Power supply: 24 V DC, max. 6.5 Amp. ; 1.3A Available for Acc.
Door width: 36 - 48" (91-122 cm)
Door weight: 90-250 lb. (41-113 kg)
Push min angle: 110° with reveal of 6-3/4" max
Push max angle: 130° with reveal of 1/8" min
Pull max angle: 180°
Hold open time: 5-30 seconds (A.D.A. 5 seconds min.)
Indenite for Hold Open Input or Endcap 3
Position Switch
Notes:
• Permanent wiring is to be employed as required
by local codes.
• Activation devices: push plates, access control,
mats, touchless wall switches, etc.
• Maximum wire size is:
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
14AWG at all other terminals
WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors. FOR INDOOR USE ONLY
Product Safety Warnings
Certifications and Standards
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Install only on a properly operating and balanced door.
A door that is operating improperly could cause severe
injury. Have qualied service personnel make repairs to any
hardware before installing the operator.
3. Remove, or make inoperative, all locks (unless mechanically
and/or electrically interlocked to the power unit) that are
connected to the door before installing the operator.
4. Do not connect the door operator to the source power
until instructed to do so.
5. Never let children operate or play with door controls. Keep
remote control (when provided) away from children.
• ETL Certied: Operator conforms to ANSI/UL standard 325 for automatic closing doors and UL10C Positive Pressure
Fire Test for Door Assemblies.
• ANSI A156.19: These products are designed to conform to this specication “for power assist and low energy power
operated doors.” These products are designed to exceed all the requirements for “Low Energy Power Operated Door”.
• Americans with Disabilities Act (A.D.A.): These door operators can be installed and adjusted to conform with A.D.A.
regulations.
• ANSI A117.1: These door controls permit door assemblies to conform to the requirements of this specication “for
buildings and facilities - providing accessibility and usability for physically handicap people”.
6. Personnel should keep away from a moving door in
motion.
7. Test door’s safety features at least once a month. After
adjusting either force or limit of travel, retest door
operator’s safety features. Failure to adjust operator
properly may cause severe injury or death.
8. KEEP DOOR PROPERLY OPERATING. See Door
Manufacturer’s Owner’s Manual. An improperly
operating door could cause severe injury or death.
Have a trained door systems technician make repairs.
9. SAVE THESE INSTRUCTIONS.
Contents
Certications and Standards...............................................................................2
Technical Data ............................................................................................2
Product Safety Warnings ..................................................................................2
Before You Begin ..........................................................................................3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Template..................................................................................................8
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21 3
6312/6352 Series (Pull Side) Power Operator
Before You Begin
• Thickness recommended for reinforcements in
hollow metal doors and frames is charted.
• This template information based upon use of 5"
maximum width butt hinges.
• Maximum frame reveal is 1/8" for 6312 units and
1/8" up to 2-3/4" maximum for 6352 units.
• Before beginning the installation, verify that the
door frame is properly reinforced and is well
anchored in the wall.
• Concealed electrical conduit and concealed switch
or sensor wires should be pulled to the frame
before proceeding.
Fasteners for Frame:
• 1/4-20 Machine screws for hollow metal and
aluminum.
• No. 14 x 2-3/4" (70mm) long sheet metal screws
for wood.
1/8"
(3)
Door
Frame
Hollow Metal Door Frame Reinforcing
Frame Material Reinforcing
Recommended Min. Required
12 Ga.
.1046
(2.66)
12 Ga.
.1046
(2.66)
18 Ga.
.0478
(1.21)
14 Ga.
.0747
(1.90)
10 Ga.
.1343
(3.41)
12 Ga.
.1046
(2.66)
16 Ga.
.0598
(1.52)
10 Ga.
.1343
(3.41)
12 Ga.
.1046
(2.66)
18 Ga.
.0478
(1.21)
8 Ga.
.1644
(4.18)
10 Ga.
.1343
(3.41)
Installation
A. Mount backplate.
1. Determine right hand or left hand installation. (Figure 1)
2. Measure and mark rst mounting hole according to template.
(Figure 2)
3. Attach backplate to frame with screw.
Do not fully tighten screw at this time.
For Metal Frames:
Use #7 drill and 1/4-20 tap for 1/4-20 machine screws.
For Wood Frames:
Use 3/16" drill and supplied screws for self drilling, self tapping
screws.
4. Ensure backplate is level and aligned with door frame. (Figure 3)
5. Using backplate as guide, mark and drill second hole. (Figure 3)
6. Insert second screw and tighten both screws.
7. Using backplate as a guide, drill and tap remaining eight (8)
holes in frame. (Figure 3)
8. Secure with eight (8) screws and tighten.
Template
Figure 1
Figure 2
Figure 3
Pull Side
Push Side
Left Hand
PULL
Right Hand
PULL
Remaining 8 Holes
2nd
Hole
Remaining 8 Holes
2nd
Hole
Right Hand Shown
Right Hand Shown
Left Hand Shown
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21
4
6312/6352 Series (Pull Side) Power Operator
B. Mount track.
1. Measure and mark track mounting holes
using template. (Figure 4)
2. Drill holes.
a. For reinforced doors, drill and tap
holes with #16 drill and12-24 tap.
b. For wood doors or self-drilling screws,
use 3/32" drill.
c. For sleeve nuts and bolts, see
illustration. (Figure 5)
3. Attach track using two (2) supplied
fasteners for application.
4. Snap track cover into place.
NOTE:
• Slider assembly and end caps must be
in track before screws can attach track
to door. (Figure 6)
• Slider must slide freely in track.
Template
Figure 4
End Cap
Slider Assembly
End Cap
Figure 5
Figure 6
19-1/8"
Center to Center
9-3/4"
Door Edge
to Hole Center
7/16"
Top of Door to
Mounting Holes
OR
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21 5
6312/6352 Series (Pull Side) Power Operator
D. Install closer body assembly.
1. Using four (4) screws, install closer body
to backplate. (Figure 8)
NOTE:
• Screws must be tightened in a
cross pattern until all four (4)
screws are tight. (Figure 8)
• Closer body is in proper
orientation for PULL SIDE
application when tube is AWAY
from backplate. (Figure 8)
2. Using three (3) supplied cable
management clips, secure cables along
closer body. (Figure 9)
1
4
2
3
Figure 7
Figure 8
Tube AWAY
from backplate
Hinge
Right Hand Shown
1. Install two (2) screws on each end of
backplate leaving about 3/16" gap between
head of screw and backplate. (Figure 7)
2. Slide end caps behind screw heads and
tighten screws. (Figure 7)
NOTE: End cap with 3-position switch
is always located on conduit side of
backplate.
NOTE: To retrofit closer assembly to an
existing operator, screws and fan inside of end
cap must be removed.
Switch End Cap
End Cap Screws
Conduit Hole
Figure 9
C. Install end caps.
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21
6
6312/6352 Series (Pull Side) Power Operator
F. Install arm.
1. Using an adjustable wrench, rotate
top pinion 45 degrees toward door
hinge. You will feel resistance from
spring. (Figure 12)
2. While holding pinion at 45 degrees,
slide arm on bottom pinion at
orientation shown. (Figure 12)
3. Using hex wrench, secure arm to
pinion with screw and nut.
(Figure 13)
4. Open door approximately 30
degrees and attach arm to slider in
track. Use hex wrench to tighten
slider bolt counter clockwise until
slide is tight in arm. (Figure 13)
5. Close door.
Figure 10
Figure 11
Track Slider Bolt
Figure 12
1. Insert two (2) screws. Leave 3/16" gap between
head of screw and backplate. (Figure 10)
2. Slide power supply key holes over screws
allowing narrow slots of key holes to rest on
screws. (Figure 10)
NOTE: Narrow slots of key holes are
always at top and control board is always at
bottom for proper installation. (Figure 10)
3. Tighten screws.
4. Plug motor and ribbon cables from closer
body into power supply. (Figure 11)
NOTE:
• Use slot in power supply to feed
connectors to board. (Figure 11)
• Use provided zip ties to manage
any excess cable between closer
and power supply so that cover
can be attached without damaging
cables. (Figure 11)
5. Connect switch to power supply.
(Figure 11)
E. Install power supply assembly. Key Hole
3/16" Gap
Cable Slot
Motor Cable
Connection
Ribbon Cable
Connection
Control Board
3 Position Switch
Cable Connection
Figure 13
Zip Tie
Norton is a brand associated with ASSA ABLOY Accessories and Door Controls Group, Inc., an ASSA ABLOY Group company.
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited. 80-9363-0008-020 Rev 4 08/21
Norton Technical Product Support:
Monroe, NC 28112 USA
Phone: 800.438.1951 ext: 6030
TechSupport.Norton@assaabloy.com
nortondoorcontrols.com
G. Adjust closing force.
NOTE: The amount of effort to manually open or
close a door is called closing force.
1. Using 1/2" socket wrench with 3/4" deep well
socket, turn nut in end of closer body tube to
desired force. (Figure 14)
NOTE: Window in closer tube shows spring.
(Figure 15)
NOTE: If additional closing force is only required
in latching region, see Latch Boost and Lock
Release features in separate programming
manual 80-9363-0015-020.
NOTE: Attach cover after initial programming has
been done. See separate programming manual
80-9363-0015-020.
1. Align cut-outs in cover to pinion shafts.
(Figure 16)
2. Slide cover onto unit using end caps as guides.
3. Snap cover securely to back plate.
4. Attach a Norton label plate to each end cap
by snapping into place by hand with gentle
pressure. (Figure 16)
H. Attach cover and end cap label plates.
WARNING: Make sure no wiring is loose
or can be caught by cover when it is
snapped into place.
Spring Window
Figure 14
Figure 15
Figure 16
You’ve now installed the 6312 or 6352 PULL SIDE Low Energy Operator.
Continue with separate Programming Manual 80-9363-0015-020 to set up and adjust operator.
6312 and 6352 Series Template
Pull Side Application ONLY
Right Hand Door Shown
Copyright © 2019, 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0008-020 Rev 4 08/21

Other manuals for Norton 6300 Series

6

This manual suits for next models

2

Other Assa Abloy Door Opening System manuals

Assa Abloy Norton 7700ST User manual

Assa Abloy

Assa Abloy Norton 7700ST User manual

Assa Abloy NORTON RIXSON 6332 User manual

Assa Abloy

Assa Abloy NORTON RIXSON 6332 User manual

Assa Abloy Corbin Russwin PED4600 A Series User manual

Assa Abloy

Assa Abloy Corbin Russwin PED4600 A Series User manual

Assa Abloy Norton 9500 Series User manual

Assa Abloy

Assa Abloy Norton 9500 Series User manual

Assa Abloy MAB 609 + AC593 Instruction Manual

Assa Abloy

Assa Abloy MAB 609 + AC593 Instruction Manual

Assa Abloy Rockwood OH200 Series User manual

Assa Abloy

Assa Abloy Rockwood OH200 Series User manual

Assa Abloy Norton 7200 Series Quick guide

Assa Abloy

Assa Abloy Norton 7200 Series Quick guide

Assa Abloy Sargent Electroguard-59 80 Series Assembly instructions

Assa Abloy

Assa Abloy Sargent Electroguard-59 80 Series Assembly instructions

Assa Abloy Corbin Russwin PED5800 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin PED5800 Series User manual

Assa Abloy G-FMS User manual

Assa Abloy

Assa Abloy G-FMS User manual

Assa Abloy Corbin Russwin ED4000 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin ED4000 Series User manual

Assa Abloy SW100 User manual

Assa Abloy

Assa Abloy SW100 User manual

Assa Abloy Adams Rite EX76 Operating instructions

Assa Abloy

Assa Abloy Adams Rite EX76 Operating instructions

Assa Abloy Corbin Russwin DC3200 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin DC3200 Series User manual

Assa Abloy Sargent FIREGUARD 2408 Series User manual

Assa Abloy

Assa Abloy Sargent FIREGUARD 2408 Series User manual

Assa Abloy Norton PR1601BF User manual

Assa Abloy

Assa Abloy Norton PR1601BF User manual

Assa Abloy Lockwood 724 Series User manual

Assa Abloy

Assa Abloy Lockwood 724 Series User manual

Assa Abloy 1370 User manual

Assa Abloy

Assa Abloy 1370 User manual

Assa Abloy Norton 7500 Series User manual

Assa Abloy

Assa Abloy Norton 7500 Series User manual

Assa Abloy Corbin Russwin DC8200 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin DC8200 Series User manual

Assa Abloy SARGENT 1130 Series User manual

Assa Abloy

Assa Abloy SARGENT 1130 Series User manual

Assa Abloy 78PRA-8L User manual

Assa Abloy

Assa Abloy 78PRA-8L User manual

Assa Abloy DC3210 User manual

Assa Abloy

Assa Abloy DC3210 User manual

Assa Abloy Norton 6300 Series Quick guide

Assa Abloy

Assa Abloy Norton 6300 Series Quick guide

Popular Door Opening System manuals by other brands

Yakima AWNING BRACKET KIT Quick start quide

Yakima

Yakima AWNING BRACKET KIT Quick start quide

RYTEC Sure-Seal manual

RYTEC

RYTEC Sure-Seal manual

Sesamo SwinGo Installation instruction

Sesamo

Sesamo SwinGo Installation instruction

cinetto PS60 Easy Assembly instructions

cinetto

cinetto PS60 Easy Assembly instructions

Dormakaba TSG-H manual

Dormakaba

Dormakaba TSG-H manual

Slycma RHEA 160 2P Installation and Servicing Manual

Slycma

Slycma RHEA 160 2P Installation and Servicing Manual

SERVETTO MOTION-VS Series Technical Info

SERVETTO

SERVETTO MOTION-VS Series Technical Info

Nabco 243681-05 installation instructions

Nabco

Nabco 243681-05 installation instructions

STAMONY ST-CSF-100 user manual

STAMONY

STAMONY ST-CSF-100 user manual

RollSeal RS-500M Installation and operation manual

RollSeal

RollSeal RS-500M Installation and operation manual

raumplus 800 AIR-B Series Assembly & installation

raumplus

raumplus 800 AIR-B Series Assembly & installation

Automatismos Pujol SC 600 II Series manual

Automatismos Pujol

Automatismos Pujol SC 600 II Series manual

fadini APROLI 380 LB instruction manual

fadini

fadini APROLI 380 LB instruction manual

SECO-LARM Enforcer SD-C141S Catalogue

SECO-LARM

SECO-LARM Enforcer SD-C141S Catalogue

Global Fire Equipment GFE-DHA V2 manual

Global Fire Equipment

Global Fire Equipment GFE-DHA V2 manual

Dormakaba Muto Premium XL150 installation instructions

Dormakaba

Dormakaba Muto Premium XL150 installation instructions

Lamp FD30-F installation manual

Lamp

Lamp FD30-F installation manual

JCM Technologies M8 user manual

JCM Technologies

JCM Technologies M8 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.