VFD-4000 I 03
Table of Contents
Perfect Solution,
Perfect W ter P ress ure
Safety Instructions
System design, installation, commissioning and maintenance must be carried out only by personnel who
have the necessary training and experience. They must carefully read this safety information and the
instructions in this Guide and follow all information regarding transport, storage, installation and use of the
VFD-4000 series, including the specified environmental limitations.
Do not perform any flash test or voltage withstand test on the VFD-4000 series
Any electrical measurements required should be carried out with the VFD-4000 series disconnected
Electric shock hazard! Disconnect and ISOLATE the VFD-4000 series before attempting any work on
it. High voltages are present at the terminals and within the drive for up to 10 minutes after
disconnection of the electrical supply. Always ensure by using a suitable multimeter that no voltage is
present on any drive power terminals prior to commencing any work.
Where supply to the drive is through a plug and socket connector, do not disconnect until 10 minutes
have elapsed after turning off the supply.
Ensure correct earthing connections and cable selection as per defined by local legistation or codes.
They drive may have a leakage current of greater than 3.5mA; furthermore the earth cable must be sufficient to carry
the maximum supply fault current which normally will be limited by the fuses or MCB. Suitably rated fuses or MCB
should be fitted in the main supply to the drivem according to any local legistration.
The level of integrity offered by the VFD-4000 series control input functions – for example stop/
start, forward and maximum speed is not sufficient for use in safety-critical applications without
independent channels of protection. All applications where malfunction could cause injury or loss of
life must be subject to a risk assessment and further protection provided where needed.
The driven motor can start at power up if the enable input signal is present.
The STOP function does not remove potentially lethal high voltages. ISOLATE the drive and wait 10 minutes before starting
any work on it. Never carry out any work on the Drive, Motor or Motor cable whilst the input power is still applied.
Do not activate the automatic ault reset function on any systems whereby this may cause a potentially dangerous situation.
When mounting the drive, ensure that sufficient cooling is provided.
Do not carry out drilling operations with the drive in place, dust and swaf from drilling may lead to damage.
The entry of conductive or flammable foreign bodies should be prevented. Flammable material should not
be placed close to the drive. Relative humidity must be less than 95% (non-condensing).
Ensure that the supply voltage, frequency and single phase input correspond to the rating of the VFD-4000 as delivered.
Never connect the mains power supply to the Output terminals U, V, W.
Do not install any type of automatic switchgear between the drive and the motor
Danger : Indicates a risk of electric shock, which, if
not avoided, could result in damage to the
equipment and possible injury or death.
Danger: Indicates a risk of electric shock, which,
if not avoided, could result in damage to the
equipment and possible injury or death.
Please read the important safety information below, and all warning and caution information elsewhere.
03
1. Safety Instructions
04
2. Specification
05
3. Basic
- Nameplate Information
- Model Name
06
4. Size and Frame
07
5. Wire Specification
08
6. Power Connection
09
7. Terminals
10
8. Keypad Description
11
9. Display
12-13
10. Operation Method / Parallel Operation
14-19
11. VFD-4000 Setting
20-22
12. Alarm Logs
VFD-4000
VFD-4000 series is intended for professional incorporation into complete equipment or systems as part of a
fixed installation. If installed incorrectly, it may present a safety hazard. The VFD-4000 series uses high
voltages and currents, carries a high level of stored electrical energy, and is used to control mechanical
plant that may cause injury. Close attention is required to system design and electrical installation to avoid
hazards in either normal operation or in the event of equipment malfunction.
Only qualified electricians are allowed to install and maintain this product.
The VFD-4000 series can be programmed to operate the driven motor at speeds above or below the speed
achieved when connecting the motor directly to the mains supply. Obtain confirmation from the
manufactures of the motor and driven machine about suitability for operation over the intended speed range
prior to machine start up.