Instruction Manual
RSD-CFA-CN and RSD-FC-CN.3km
Subject to reasonable modifications due to technical advances Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group·Tel.: Germany (6 21) 776-11 11·USA (3 30) 4 2535 55·Sin
apore 7 79 90 91·Internet http://www.pepperl-fuchs.com
Part. No.: 97762, 15.07.1999
Instruction Manual
RSD-CFA-CN and RSD-FC-CN.3km
Subject to reasonable modifications due to technical advances Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group·Tel.: Germany (6 21) 776-11 11·USA (3 30) 4 2535 55·Sin
apore 7 79 90 91·Internet http://www.pepperl-fuchs.com
Part. No.: 97762, 15.07.1999
Installation
The RSD-CFA-CN and the RSD-FC-CN.3km must not be exposed to the environ-
ment.Providea separateenclosurewithaprotectionfactorofatleast IP54.These
modules must be installed in such a wa
that protection factor IP20 is
uaranteed.
Repair
These modules are not field-repairable. An
attempt to open these modules will
void the warrant
and IS certification. If repair is necessar
, return these modules
to the factor
.
ESD
Protect the s
stem a
ainst electrostatic char
e. Post a si
n near these modules:
„Attention! Avoid electrostatic char
e“.
Ambient Temperature
The ambient temperature of these modules
-20 °C...+70 °C
has to be conside-
red, especiall
when the modules are mounted in a cabinet where the internal
temperature is increased b
the power dissipation of the modules itself.
European Union Directive Compliance
If this product has the CE mark it is approved for installation within the European
Union and EEA re
ions. It has been desi
ned and tested to meet the followin
di-
rectives:
EMC Directive
This product is tested to meet Council Directive 89/336/EEC Electroma
netic
Compatibilit
EMC
and the followin
standards, in whole or part, documented in
a technical construction file:
- EN 50081-2; EMC-Generic Emission Standard, Part 2 - Industrial Enviroment.
- EN 50082-2; EMC-Generic Immunit
Standard, Part 2 - Industrial Enviroment.
This product is intended for use in an industrial enviroment.
Low Voltage Directive
This product is tested to meet Council Directive 73/23/EEC Low Volta
e, b
app-
l
in
the safet
re
uirements of EN 61131-2 Pro
rammable Controllers, Part 2 -
E
uipment Re
uirements and Tests.
For specific informations re
uired b
EN 61131-2, see the appropriate sections in
this publication.
This e
uipment is classified as open e
uipment and must be mounted in an enclo-
sure durin
operation to provide safet
protection.
The Copper/Fiber-Adapter RSD-CFA-CN works in con
unction with the Fiber-
Coupler RSD-FC-CN.3km.
Mounting
The RSD-CFA-CN and the RSD-FC-CN.3km do not need a separate Terminal
Base. The Copper/Fiber-Adapter provides the couplin
to the ControlNet coaxca-
ble, the Fiber-Coupler realizeses the connection to the fiber optic cable. Both de-
vices are connected via a plu
, which is located at the ri
ht hand side of the RSD-
CFA-CN and the left hand side of the RSD-FC-CN.3km. Before both devices are
mounted the cover plu
on both units must be removed. Onl
remove the cover
plu
when mountin
. The mountin
and the connection of the devices is shown
infi
ure 1.
Fi
ure 1
A maximum of 2 RSD-FC-CN.3km are allowed to be connected to one