1. Marking
VisuNet FLX – System with Enclosure
RemoteMonitorRM-320S-*
PersonalComputerPC-320S-*
EquipmentprotectionlevelGc
ATEXcertificate:PF21CERT6290X
ATEXmarking:1II3GExec[ic]IICT4Gc
EquipmentprotectionlevelDc
ATEXcertificate:PF21CERT6290X
ATEXmarking:1II3DExtc[ic]IIICT85°CDc
VisuNet FLX – System with Enclosure
DirectMonitorDM-320S-*
EquipmentprotectionlevelGc
ATEXcertificate:PF21CERT6290X
ATEXmarking:1II3GExecIICT4Gc
EquipmentprotectionlevelDc
ATEXcertificate:PF21CERT6290X
ATEXmarking:1II3DExtcIIICT85°CDc
The*-markedlettersofthetypecodeareplaceholdersforversionsofthe
device.
Pepperl+FuchsGroup
Lilienthalstraße200,68307Mannheim,Germany
Internet:www.pepperl-fuchs.com
2. Validity
Specificprocessesandinstructionsinthisinstructionmanualrequire
specialprovisionstoguaranteethesafetyoftheoperatingpersonnel.
3. Reference to Further Documentation
Observelaws,standards,anddirectivesapplicabletotheintendeduse
andtheoperatinglocation.ObserveDirective1999/92/ECinrelationto
hazardousareas.
Thecorrespondingdatasheets,manuals,declarationsofconformity,EU-
typeexaminationcertificates,certificates,andcontroldrawingsif
applicable(seedatasheet)areanintegralpartofthisdocument.Youcan
findthisinformationunderwww.pepperl-fuchs.com.
Duetoconstantrevisions,documentationissubjecttopermanentchange.
Pleasereferonlytothemostup-to-dateversion,whichcanbefoundunder
www.pepperl-fuchs.com.
4. Target Group, Personnel
Responsibilityforplanning,assembly,commissioning,operation,
maintenance,anddismountinglieswiththeplantoperator.
Thepersonnelmustbeappropriatelytrainedandqualifiedinordertocarry
outmounting,installation,commissioning,operation,maintenance,and
dismountingofthedevice.Thetrainedandqualifiedpersonnelmusthave
readandunderstoodtheinstructionmanual.
5. Intended Use
Thedeviceisonlyapprovedforappropriateandintendeduse.Ignoring
theseinstructionswillvoidanywarrantyandabsolvethemanufacturer
fromanyliability.
TheVisuNetFLXSystemsaredesignedforZone2/22andnon-Ex
applications.Thedifferentmountingandconfiguringoptionsleadtothe
highestapplicationflexibility.Duetoafullymodulardesign,thenew
platform,whichisgearedtotheneedsofthe(petro-)chemicaland
pharmaceuticalindustries,theHMIscanbeconfiguredtofitexactlyand
enablessimpleandfastadjustmentsinthefield.
Usethedeviceonlywithinthespecifiedambienttemperaturerange.
Usethedeviceonlywithinthespecifiedambientandoperatingconditions.
Taketheintendeduseoftheconnecteddevicesfromthecorresponding
documentation.
Taketheintendeduseoftheinstalleddevicesfromthecorresponding
documentation.
Thedeviceisanelectricalapparatusforhazardousareas.
Thedeviceisnotsuitableforseparatinghazardousareas.
DevicesforwhichspecificconditionsofuseapplyhavetheXmarkingat
theendofthecertificatenumber.
Onlyusethedevicestationary.
6. Improper Use
Protectionofthepersonnelandtheplantisnotensuredifthedeviceisnot
usedaccordingtoitsintendeduse.
Thedeviceisnotsuitabletoseparateintrinsicallysafecircuitsfromnon-
intrinsicallysafecircuits.
Thedeviceisnotsuitableforseparatinghazardousareas.
7. Mounting and Installation
Priortomounting,installation,andcommissioningofthedeviceyou
shouldmakeyourselffamiliarwiththedeviceandcarefullyreadthe
instructionmanual.
Donotstaybelowtheopendevice.Inordertoavoidpersonalinjuriesor
propertydamage,makeappropriateprovisionsforthemountingand
maintenanceprocedures.
Usemountingmaterialswhicharesuitabletosecurethedevicesafely.
Usemountingmaterialsthatfitthenatureofthemountingsurface.
Onlyuseaccessoriesspecifiedbythemanufacturer.
Mountthedeviceinaweatherprooflocation.
Ensurethattheoperatinglocationhasasufficientfloorloadcapacity.
Ifmountingtheenclosureonconcreteuseexpansionanchors.When
mountingtheenclosuretoasteelframeworkusevibrationresistant
mountingmaterial.
Ensurethatallfastenersarepresent.
Observethetighteningtorqueofthescrews.
Protectthedeviceagainstlong-termorexcessivemechanicalvibrations.
Thedeviceisheavy.Inordertoavoidpersonalinjuriesorproperty
damage,makeappropriateprovisionsforthemountingprocedure.
Donotmountthedeviceatlocationswhereanaggressiveatmosphere
maybepresent.
Donotdamagethebreatherdrain.
Donotcoverthebreatherdrain.
ObservetheinstallationinstructionsaccordingtoIEC/EN60079-14.
ObservetheinstallationinstructionsaccordingtoIEC/EN60079-25.
Ifthedevicehasalreadybeenoperatedingeneralelectricalinstallations,
thedevicemaysubsequentlynolongerbeinstalledinelectrical
installationsusedincombinationwithhazardousareas.
Ensurethattheequipotentialbondingconnectionsareingoodcondition,
andarenotdamagedorcorroded.
Ensurethattheterminalsareingoodconditionandarenotdamagedor
corroded.
Whenconnectingintrinsicallysafedeviceswithintrinsicallysafecircuitsof
associatedapparatus,observethemaximumpeakvalueswithregardto
explosionprotection(verificationofintrinsicsafety).Observethe
standardsIEC/EN60079-14orIEC/EN60079-25.
Provideatransientprotection.Ensurethatthepeakvalueofthetransient
protectiondoesnotexceed140%oftheratedvoltage.
Thedevicemustbeinstalledandoperatedonlyinacontrolled
environmentthatensuresapollutiondegree2(orbetter)accordingto
IEC/EN60664-1.
Thedevicemustbedisconnectedfromthepowersupplypriorto
installationandmaintenance.Thepowersupplymaybeactivatedonly
afterallthecircuitsrequiredforoperationhavebeenfullyassembledand
connected.
OnlyconnectadevicethatisinaccordancewithIEC/EN60950-1andis
designedassafetyextra-lowprotectivevoltage(SELV)system.
Protectthecircuitagainstovervoltage(e.g.,lightning).
Thedeviceprovidesagroundingterminaltowhichanequipotential
bondingconductorwithaminimumcrosssectionof4mm²mustbe
connected.
Requirements in Relation to Intrinsic Safety
IfcircuitswithtypeofprotectionExiareoperatedwithnon-intrinsically
safecircuits,theymustnolongerbeusedascircuitswithtypeof
protectionExi.
Observethemaximumvaluesofthedevice,whenconnectingthedevice
tointrinsicallysafeapparatus.
Keeptheseparationdistancesbetweenallnon-intrinsicallysafecircuits
andintrinsicallysafecircuitsaccordingtoIEC/EN60079-14.
Observethecomplianceoftheseparationdistancesbetweentwo
adjacentintrinsicallysafecircuitsaccordingtoIEC/EN60079-14.
Circuitsofintrinsicallysafeapparatuscanbeledintohazardousareas,
wherebyspecialattentionmustbepaidtomaintainingseparation
distancestoallnon-intrinsicallysafecircuitsaccordingtotherequirements
inIEC/EN60079-14.
ObservethegroundingrequirementsfortypeofprotectionExiaccording
toIEC/EN60079‑14.
Forintrinsicallysafecircuits,thedielectricstrengthoftheinsulationagainst
otherintrinsicallysafecircuitsandagainsttheshieldmustbe
atleast500VaccordingtoIEC/EN60079-14.
Equipotentialbondingmustbeachievedalongtheintrinsicallysafe
circuits.
Requirements for Cable Glands
Installthecablesandthecableglandsinaccordancewith
IEC/ENIEC60079-0andIEC/EN60079-14.
Onlyusecablesandconnectionlineswithatemperaturerange
appropriatetotheapplication.
Useonlyoneconnectionlineperopening.
Useonlyoneconductorperterminal.
Adjustthesealingelementofthecableglandtothediameterofthecables
andconnectionlinesused.
Observethetighteningtorqueofthecableglands.
DOCT-7048C/2021-10 1/2
Tightenallcableglandswiththeappropriatetorque.
Ensurethatallcableglandsareingoodconditionandaresecurely
tightened.
Closeallunusedcableglandswiththeappropriatesealingplugs.
Requirements for Cables and Connection Lines
Observethemaximumpermissiblelengthofcablesandconnectionlines.
Thedielectricstrengthoftheinsulationmustbeatleast500Vaccordingto
IEC/EN60079-14.
Observethepermissiblecorecrosssectionoftheconductor.
Theinsulationstrippinglengthmustbeconsidered.
Wheninstallingtheconductorstheinsulationmustreachuptothe
terminal.
Whenusingstrandedconductors,crimpwireendferrulesonthe
conductorends.
Observetheminimumbendingradiusoftheconductors.
Thenominalcorecrosssectionofaconnectedconductoris2.5mm2
(solid,finelystranded,andstranded).
Unusedcablesandconnectionlinesmustbeeitherconnectedtoterminals
orsecurelytieddownandisolated.
Installthecablesandconnectionlinesinsuchawaythattheyare
protectedfromultravioletradiation.
Installcablesandcableglandsinawaythattheyarenotexposedto
mechanicalhazards.
Equipotentialbondingmustbeachievedalongthefieldcircuits.
Requirements in Relation to Electrostatics
Avoidelectrostaticchargeswhichcouldresultinelectrostaticdischarges
whileinstalling,operating,ormaintainingthedevice.
Avoidinadmissiblyhighelectrostaticchargeofthecablesandconnection
lines.
Includethemetalhousingcomponentsintheequipotentialbonding.
Anelectrostaticchargeposesanignitionhazardincaseofdischarge.
Includethefastenersintheequipotentialbonding.
Requirements for Surrounding Enclosures
Ifadditionalsurroundingenclosuresarerequired,thefollowingpointsmust
beconsideredduringinstallation:
lDegreeofprotectionaccordingtoIEC/EN60529
lResistancetolightaccordingtoIEC/EN60079-0
lResistancetoimpactaccordingtoIEC/EN60079-0
lResistancetochemicalagentsaccordingtoIEC/EN60079-0
lThermalenduranceaccordingtoIEC/EN60079-0
lElectrostaticsaccordingtoIEC/EN60079-0
Mountthesurroundingenclosureinawaythatallhousingoutlets,e.g.,
cableglandsandbreatherdrainsfacedownwards.
Whentheenclosurecoverisfitted,ensurethatallfastenersarefully
tightened.
Mountthedevicesothatitcomplieswiththespecifieddegreeof
protectionaccordingtoIEC/EN60529.
Forcableglandsonlyuseincomingcablediametersoftheappropriate
size.
Ensurethatthesurroundingenclosureisnotdamaged,distorted,or
corroded.
Ensurethatallsealsareclean,undamaged,andcorrectlyfitted.
Tightenallscrewsofthesurroundingenclosure/surroundingenclosure
coverwiththeappropriatetorque.
Closeallunusedenclosureholeswiththeappropriatestoppingplugs.
8. Operation, Maintenance, Repair
Priortousingtheproductmakeyourselffamiliarwithit.Readthe
instructionmanualcarefully.
Donotstaybelowtheopendevice.Inordertoavoidpersonalinjuriesor
propertydamage,makeappropriateprovisionsforthemountingand
maintenanceprocedures.
ObserveIEC/EN60079-17formaintenanceandinspection.
Donotuseadamagedorpolluteddevice.
Ifthereisadefect,thedevicemustberepairedbyPepperl+Fuchs.
Thedevicemustnotberepaired,changed,ormanipulated.Incaseof
failure,alwaysreplacethedevicewithanoriginaldevice.
Observethewarningmarkings.
Donotremovethewarningmarkings.
Ifthedeviceisinstalledinpotentiallyexplosivedustatmosphere,remove
dustlayerswhichexceed5mminregularintervals.
Removethedustbeforeopeningthesurroundingenclosure.
Connectionordisconnectionofenergizednon-intrinsicallysafecircuitsis
onlypermittedintheabsenceofapotentiallyexplosiveatmosphere.
Ifcleaningisnecessarywhilethedeviceislocatedinahazardousarea,in
ordertoavoidelectrostaticchargingonlyuseacleandampcloth.
Thedevicecangetveryhotduringoperation.Toprotectthedevicefrom
excessiveheating,observetherequiredclearancesandsufficient
ventilationwheninstallingthedevice.
9. Delivery, Transport, Disposal
Checkthepackagingandcontentsfordamage.
Checkifyouhavereceivedeveryitemandiftheitemsreceivedarethe
onesyouordered.
Keeptheoriginalpackaging.Alwaysstoreandtransportthedeviceinthe
originalpackaging.
Storethedeviceinacleananddryenvironment.Thepermittedambient
conditionsmustbeconsidered,seedatasheet.
Thedevice,built-incomponents,packaging,andanybatteriescontained
withinmustbedisposedincompliancewiththeapplicablelawsand
guidelinesoftherespectivecountry.
DOCT-7048C/2021-10 2/2

Other Pepperl+Fuchs Industrial Equipment manuals

Pepperl+Fuchs PCV F200-B6-V15B Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PCV F200-B6-V15B Series User manual

Pepperl+Fuchs FieldConnex D0-TI-Ex8 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs FieldConnex D0-TI-Ex8 Series User manual

Pepperl+Fuchs MLV11 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs MLV11 Series User manual

Pepperl+Fuchs IUH-F192-V1 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs IUH-F192-V1 Series User manual

Pepperl+Fuchs LGS Series User manual

Pepperl+Fuchs

Pepperl+Fuchs LGS Series User manual

Pepperl+Fuchs LS611 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs LS611 Series User manual

Pepperl+Fuchs RSD-CFA-CN User manual

Pepperl+Fuchs

Pepperl+Fuchs RSD-CFA-CN User manual

Pepperl+Fuchs PGV Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PGV Series User manual

Pepperl+Fuchs KFU8-DW-1.D User manual

Pepperl+Fuchs

Pepperl+Fuchs KFU8-DW-1.D User manual

Pepperl+Fuchs PGV100R-F200-B16 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PGV100R-F200-B16 Series User manual

Pepperl+Fuchs IQT-F116-R4-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs IQT-F116-R4-V1 User manual

Pepperl+Fuchs 6000 SERIES User manual

Pepperl+Fuchs

Pepperl+Fuchs 6000 SERIES User manual

Pepperl+Fuchs VisuNet TCU1100 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs VisuNet TCU1100 Series User manual

Pepperl+Fuchs 7500 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs 7500 Series User manual

Pepperl+Fuchs Bebco EPS 6100 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs Bebco EPS 6100 Series User manual

Pepperl+Fuchs KCDO-LGH User manual

Pepperl+Fuchs

Pepperl+Fuchs KCDO-LGH User manual

Pepperl+Fuchs 1001A Series User manual

Pepperl+Fuchs

Pepperl+Fuchs 1001A Series User manual

Pepperl+Fuchs F112 User manual

Pepperl+Fuchs

Pepperl+Fuchs F112 User manual

Pepperl+Fuchs R2-SP-N Series User manual

Pepperl+Fuchs

Pepperl+Fuchs R2-SP-N Series User manual

Pepperl+Fuchs PCV F200-R4-V19 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PCV F200-R4-V19 Series User manual

Pepperl+Fuchs VisuNet TCU1100 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs VisuNet TCU1100 Series User manual

Pepperl+Fuchs MLV12-54-LAS-300/76b/95 User manual

Pepperl+Fuchs

Pepperl+Fuchs MLV12-54-LAS-300/76b/95 User manual

Pepperl+Fuchs VisuNet FLX User manual

Pepperl+Fuchs

Pepperl+Fuchs VisuNet FLX User manual

Pepperl+Fuchs 1001B Series User manual

Pepperl+Fuchs

Pepperl+Fuchs 1001B Series User manual

Popular Industrial Equipment manuals by other brands

SCHUNK GSM-W Series Assembly and operating manual

SCHUNK

SCHUNK GSM-W Series Assembly and operating manual

Festo EGC-TB-KF operating instructions

Festo

Festo EGC-TB-KF operating instructions

ABB ACS280 Quick installation and start-up guide

ABB

ABB ACS280 Quick installation and start-up guide

Parker IQAN-LST Installation

Parker

Parker IQAN-LST Installation

Hydac CMP 43x0-7/-T013 Series Installation and maintenance instructions

Hydac

Hydac CMP 43x0-7/-T013 Series Installation and maintenance instructions

GIGAIPC QBiX-Pro-WHLA8565H-A1 quick start guide

GIGAIPC

GIGAIPC QBiX-Pro-WHLA8565H-A1 quick start guide

YZ Systems DynaPak DP-2010TP System Support Manual

YZ Systems

YZ Systems DynaPak DP-2010TP System Support Manual

Nidec LEROY-SOMER LSA 49.1 IC 06 Installation and Maintenance

Nidec

Nidec LEROY-SOMER LSA 49.1 IC 06 Installation and Maintenance

CNC Design D-500 instructions

CNC Design

CNC Design D-500 instructions

Loepfe YARNMASTER 1N1 instruction manual

Loepfe

Loepfe YARNMASTER 1N1 instruction manual

nystrom EJ-FLF140 Installation, operation and maintenance manual

nystrom

nystrom EJ-FLF140 Installation, operation and maintenance manual

Viking G-6000P Technical data

Viking

Viking G-6000P Technical data

NARGESA MX700 Instruction book

NARGESA

NARGESA MX700 Instruction book

GAP Geysers Eco Max Homeowner's manual

GAP

GAP Geysers Eco Max Homeowner's manual

Sesino AP EMX Series Use and maintenance manual

Sesino

Sesino AP EMX Series Use and maintenance manual

tpt HB10 Operation manual

tpt

tpt HB10 Operation manual

SICK DKV60 operating instructions

SICK

SICK DKV60 operating instructions

Titan 759-135 owner's manual

Titan

Titan 759-135 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.