POS-X Xi2000-BT Series User manual

Xi2000-BT Series
Configuration Guide
POS-X, Inc.
2130 Grant St.
Bellingham, WA 98225
360-738-8533
U.S. Default Settings Sequence
•Enter Setup
•Reset Scanner
•Enable Auto-Sense Mode ON
•UPC-A Convert to EAN-13 OFF
•UPC-E Lead Zero ON
Save Changes
Exit Setup without Changes

Table of Contents
Restore Default Settings.......................................................................................ii
Set Connection ......................................................................................................1
RF Auto Shutdown Duration...............................................................................1
Memory Mode Parameters..................................................................................2
List Setting.............................................................................................................3
Buzzer Settings......................................................................................................3
Reading Redundancy Setting...............................................................................4
Scan Mode Setting ................................................................................................4
Auto-Sense Setting................................................................................................4
Scanner Time-out Duration.................................................................................5
Negative Barcode Setting .....................................................................................5
Delay between Reread..........................................................................................5
Keyboard Wedge Parameters..............................................................................6
Laptop Support.....................................................................................................8
RS-232 Parameters...............................................................................................9
Bluetooth Serial Port Parameters......................................................................11
Prefix / Postfix Settings.......................................................................................12
Character Substitution.......................................................................................12
Code ID Selection................................................................................................12
Code ID Setting...................................................................................................13
Length Code Setting (2 digits) ...........................................................................14
Select Readable Codes........................................................................................17
Code39 Parameters.............................................................................................22
Italy Pharmacode Parameters...........................................................................22
French Pharmacode Parameters.......................................................................23
Industrial 25 Parameters....................................................................................23
Interleave 25 Parameters ...................................................................................24
Matrix 25 Parameters.........................................................................................26
Codabar Parameters...........................................................................................27
Plessey Parameters .............................................................................................28
Telepen Parameters............................................................................................28
MSI Parameters..................................................................................................29
MSI Parameters..................................................................................................29
EAN128 Parameters...........................................................................................30
EAN8 Parameters...............................................................................................31
UPCA Parameters...............................................................................................31
UPCE Parameters...............................................................................................32
EAN13 Parameters.............................................................................................33
RSS Code ID Selection .......................................................................................34
RSS14 Parameters ..............................................................................................34
RSS Limited Parameters....................................................................................35
RSS Limited Parameters....................................................................................35
Activate Editing Formats...................................................................................36
Editing Format Parameters...............................................................................37
Decimal Digits.....................................................................................................49
Hexadecimal Digits.............................................................................................50
RS-232 Character Table ....................................................................................51

1
Update
Set Connection
*
Programming Instructions : (1) Read the label. (2) Read the Serial Number
barcode on the bottom of the desired 3660 Base Station within 5 seconds to
complete this setting.
RF Auto Shutdown Duration
*
Programming Instructions : (1) Read the label. (2) Program the desired auto
shutdown duration (in minutes) by reading Decimal Digits on page 49. (3) Read
the “Validate” label (also on page 49) to complete this setting.
2
Enter Setup
Memory Mode Parameters
•Memory Mode
Enable
< Disable >
•Clear Data
Clear
Confirm
•Send Data
•Memory Data Delay
< 0 >
2 sec
250 ms
3 sec
500 ms
5 sec
1 sec
8 sec

3
Update
List Setting
Page1
Page 6
Page 2
Page 7
Page 3
Page 8
Page 4
Page 9
Page 5
Page 10
Buzzer Settings
< Buzzer Enable>
Buzzer Disable
•Buzzer Frequency
8 kHz
< 4 kHz >
2 kHz
1 kHz
4
Enter Setup
Reading Redundancy Setting
< No Redundancy >
2 Times
3 Times
4 Times
Scan Mode Setting
Auto Off Mode
< Continuous Mode >
Auto Power Off Mode
Alternate Mode
Momentary Mode
Repeat Mode
Laser Mode
Test Mode
Auto-Sense Setting
< Enable >
Disable

5
Update
Scanner Time-out Duration
*
Programming Instructions : (1) Read the label. (2) Program the desired time-out
duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also
on page 49) to complete this setting.
Negative Barcode Setting
Enable
< Disable >
Delay between Reread
100 ms
1 sec
200ms
2 sec
< 400 ms >
3 sec
800 ms
5 sec
6
Enter Setup
Keyboard Wedge Parameters
•Activate and Select Keyboard Type
*
Programming Instructions : (1) Read the label. (2) Program the desired keyboard
number (shown in the following table) by reading Decimal Digits on page 49. (3)
Read the “Validate” label (also on page 49) to complete this setting.
•Keyboard Table
No. Keyboard Type
1 PCAT (US)
2 PCAT (French)
3 PCAT (German)
4 PCAT (Italy)
5 PCAT (Swedish)
6 PCAT (Norwegian)
7 PCAT (UK)
8 PCAT (Belgium)
9 PCAT (Spanish)
10 PCAT (Portuguese)
11 PS55 A01-1
12 PS55 A01-2
13 PS55 A01-3
14 PS55 001-1
15 PS55 001-81
16 PS55 001-2
17 PS55 001-82
18 PS55 001-3
19 PS55 001-8A
20 PS55 002-1, 003-1
21 PS55 002-81, 003-81
22 PS55 002-2, 003-2
23 PS55 002-82, 003-82
24 PS55 002-3, 003-3
25 PS55 002-8A, 003-8A
26 IBM 3477 (Japanese)
27 PS2-30
28 IBM 34XX/319X, Memorex Telex 122 Keys

7
Update
•Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
•Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
•Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
•Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
8
Enter Setup
•Alphabet Transmission
< Case Sensitive >
Ignore Case
•Digits Transmission
< Alphanumeric Key >
Numeric Key
•Alt Composing
Yes
< No >
•Inter-Character Delay
*
Programming Instructions : (1) Read the label. (2) Program the desired inter-
character delay by reading Decimal Digits on page 49. (3) Read the “Validate”
label (also on page 49) to complete this setting.
Laptop Support
< Disable>
Enable

9
Update
RS-232 Parameters
•Activate RS232 Interface
•Baud Rate
115200
38400
19200
< 9600 >
4800
2400
1200
300
•Parity
Even
Odd
< No Parity >
•Data Bit
< 8 >
7
10
Enter Setup
•Flow Control
< None >
Scanner Ready
Data Ready
INV. Data Ready
•Inter-Character Delay
*
Programming Instructions : (1) Read the label. (2) Program the desired inter-
character delay by reading Decimal Digits on page 49. (3) Read the “Validate”
label (also on page 49) to complete this setting.

11
Update
Bluetooth Serial Port Parameters
•Activate BlueTooth Serial Port Interface
•Device Name Broadcasting
< Yes >
No
•Authentication
Yes
< No >
•PIN Code
*
Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete
this setting. (4) Max 6 characters for this PIN Code setting.
12
Enter Setup
Prefix / Postfix Settings
Prefix Code *
Postfix Code *
Character Substitution
Set 1 *
Set 2 *
Set 3 *
Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete
this setting.
Code ID Selection
•Clear All Code ID Settings
•Select Code ID Set
Set 1
Set 2
Set 3
Set 4
Set 5

13
Update
Code ID Setting
Code 39 *
Italy Pharmacode *
French Pharmacode *
Industrial 25 *
Interleave 25 *
Matrix 25 *
Codabar *
UPCA *
UPCE *
EAN8 *
EAN13 *
Code 93 *
Code 128 *
MSI *
Plessey *
Telepen *
Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this
setting.
14
Enter Setup
Length Code Setting (2 digits)
•Code 39 Length Code
Enable
< Disable >
•Italy Pharmacode Length Code
Enable
< Disable >
•French Pharmacode Length Code
Enable
< Disable >
•Industrial 25 Length Code
Enable
< Disable >
•Interleave 25 Length Code
Enable
< Disable >

15
Update
•Matrix 25 Length Code
Enable
< Disable >
•Codabar Length Code
Enable
< Disable >
•UPCA Length Code
Enable
< Disable >
•UPCE Length Code
Enable
< Disable >
•EAN8 Length Code
Enable
< Disable >
•EAN13 Length Code
Enable
< Disable >
16
Enter Setup
•Code 93 Length Code
Enable
< Disable >
•Code 128 Length Code
Enable
< Disable >
•EAN128/RSS Length Code
Enable
< Disable >
•MSI Length Code
Enable
< Disable >
•Plessey Length Code
Enable
< Disable >
•Telepen Length Code
Enable
< Disable >

17
Update
Select Readable Codes
•Code 39
< Enable >
Disable
•Italy Pharmacode
Enable
< Disable >
•French Pharmacode
Enable
< Disable >
•Industrial 25
< Enable >
Disable
•Interleave 25
< Enable >
Disable
18
Enter Setup
•Matrix 25
Enable
< Disable >
•Codabar
< Enable >
Disable
•Code 93
< Enable >
Disable
•Code 128
< Enable >
Disable
•EAN128
Enable
< Disable >
•MSI
Enable
< Disable >

19
Update
•Plessey
Enable
< Disable >
•Telepen
Enable
< Disable >
•UPCA
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
20
Enter Setup
•UPCE
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
•EAN8
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >

21
Update
•EAN13
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
RSS14
Enable
< Disable >
•RSS Limited
Enable
< Disable >
•RSS Expanded
Enable
< Disable >
22
Enter Setup
Code39 Parameters
•Standard / Full ASCII Code39
< Standard >
Full ASCII
•Start / Stop Transmission
Enable
< Disable >
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
Italy Pharmacode Parameters
•Checksum Transmission
< Enable >
Disable>

23
Update
French Pharmacode Parameters
•Checksum Transmission
< Enable >
Disable
Industrial 25 Parameters
•Start / Stop Selection
< Industrial 25 >
Interleave 25
Matrix 25
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
24
Enter Setup
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
Interleave 25 Parameters
•Start / Stop Selection
Industrial 25
< Interleave 25 >
Matrix 25

25
Update
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
26
Enter Setup
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
Matrix 25 Parameters
•Start / Stop Selection
Industrial 25
Interleave 25
< Matrix 25 >
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable

27
Update
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
Codabar Parameters
•CLSI Conversion
Enable
< Disable >
•Start / Stop Transmission
Enable
< Disable >
28
Enter Setup
•Start / Stop Selection
< abcd / abcd >
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
Plessey Parameters
•Convert to UK Plessey
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
Telepen Parameters
•Telepen Output
< AIM Telepen >
Original Telepen

29
Update
MSI Parameters
•Checksum Verification
< Single Modulo 10 >
Double Modulo 10
Modulo 11 & 10
•Checksum Transmission
< Last digit not Transmitted >
Transmitted
Last 2 Digits not Transmitted
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
30
Enter Setup
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49)
to complete this setting.
EAN128 Parameters
•Code ID Transmission
Enable
< Disable >
•Field Separator
*
Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this
setting.

31
Update
EAN8 Parameters
•Convert to EAN13
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
UPCA Parameters
•Convert to EAN13
Enable
< Disable >
•System Number Transmission
< Enable >
Disable
•Checksum Transmission
< Enable >
Disable
32
Enter Setup
UPCE Parameters
•System Number Selection
System Number 0 and 1
< System Number 0 only >
•Convert to UPCA
Enable
< Disable >
•System Number Transmission
< Enable >
Disable
•Checksum Transmission
< Enable >
Disable

33
Update
EAN13 Parameters
•ISBN Conversion
Enable
< Disable >
•ISSN Conversion
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
34
Enter Setup
RSS Code ID Selection
]C1
< ]e0 >
RSS14 Parameters
•Code ID Transmission
< Enable >
Disable
•Application ID Transmission
< Enable >
Disable
•Checksum Transmission
< Enable >
Disable

35
Update
RSS Limited Parameters
•Code ID Transmission
< Enable >
Disable
•Application ID Transmission
< Enable >
Disable
•Checksum Transmission
< Enable >
Disable
RSS Limited Parameters
•Code ID Transmission
< Enable >
Disable
36
Enter Setup
Activate Editing Formats
•Format 1
Enable
< Disable >
•Format 2
Enable
< Disable >
•Format 3
Enable
< Disable >
•Exclusive Data Editing
Yes
< No >
•Apply Editing Format to Telepen
< Yes >
No
Table of contents
Other POS-X Barcode Reader manuals

POS-X
POS-X EVO-SG1-AD User manual

POS-X
POS-X ION 2D Bluetooth User manual

POS-X
POS-X ION Linear User manual

POS-X
POS-X ION Short Series User manual

POS-X
POS-X ION BLUETOOTH User manual

POS-X
POS-X Xi3000 User manual

POS-X
POS-X EVO 2D User manual

POS-X
POS-X ION Short Range User manual

POS-X
POS-X Xi3000 User manual

POS-X
POS-X EVO Laser User manual