POS-X Xi3000BT User manual

Xi3000 Bluetooth Wireless Scanners
Configuration Guide
Table of Contents
Revision History.........................................................................................v
Restore Default Settings............................................................................1
Exit Setup without Changes......................................................................1
Set Connection............................................................................................1
RF Auto Shutdown Duration....................................................................1
Transmit Buffer Setting ............................................................................1
Memory Mode Parameters .......................................................................2
List Setting..................................................................................................3
Buzzer Settings...........................................................................................3
Reading Redundancy Setting....................................................................4
Scan Mode Setting .....................................................................................4
Auto-Sense Setting.....................................................................................4
Scanner Time-out Duration......................................................................5
Negative Barcode Setting ..........................................................................5
Delay between Reread ...............................................................................5
Keyboard Wedge Parameters...................................................................6
RS-232 Parameters....................................................................................9
Bluetooth Serial Port Parameters...........................................................11
Bluetooth HID Parameters......................................................................12
Prefix / Postfix Settings............................................................................15
Character Substitution............................................................................15
Code ID Selection.....................................................................................15
Code ID Setting........................................................................................16
Length Code Setting (2 digits) ................................................................18
Select Readable Codes.............................................................................21
Code39 Parameters..................................................................................26
Italy Pharmacode Parameters................................................................26
French Pharmacode Parameters............................................................27
Industrial 25 Parameters.........................................................................27
Interleave 25 Parameters ........................................................................28
Matrix 25 Parameters..............................................................................30
Codabar Parameters................................................................................31
Plessey Parameters...................................................................................32
Telepen Parameters.................................................................................32
MSI Parameters.......................................................................................33
EAN128 Parameters ................................................................................34
EAN8 Parameters ....................................................................................35

UPCA Parameters....................................................................................35
UPCE Parameters....................................................................................36
EAN13 Parameters..................................................................................37
RSS Code ID Selection ............................................................................38
RSS14 Parameters ...................................................................................38
RSS Limited Parameters.........................................................................39
RSS Expanded Parameters.....................................................................39
Activate Editing Formats........................................................................40
Editing Format Parameters....................................................................41
Decimal Digits ..........................................................................................53
Hexadecimal Digits..................................................................................54
Key Type...................................................................................................55
Key Status.................................................................................................55
KBD Wedge Character Table.................................................................56
RS-232 Character Table..........................................................................56

Revision History
Version Release Date Notes
V 1.00 Oct. 31, 2005 First release.
V 2.00 Dec.30, 2005 Supports Bluetooth HID.
Firmware version: V4.10
V2.10 Jan.18, 2006 1. Updated:
zBluetooth HID: The default setting of
Capital Lock Setting is changed from
Auto Detection to Capital Lock
OFF.
zBluetooth HID doesn’t support the
following functions on PDA for Win
CE.
Capital Lock Setting: Auto
Detection
Digit Transmission: Numeric
Key
Alt Composing
2. Firmware version: V4.20
V2.11 Jan.27, 2006 Typo:
1. Baud Rate 19200 instead of 119200 at
page 9.
2. by reading Decimal Digits at page 52
instead of page 53.
3. by reading Hex Decimal Digits at page
53 instead of page 53.
V2.12 Mar.03, 2006 HID Japanese keyboard added.
V2.13 ~
V2.14 Nov, 06 2006 Same as V2.12
V2.15 Nov, 13 2006 Power Saving added for SPP and HID at
page 11 and 13

1
Update
Restore Default Settings
Exit Setup without Changes
Set Connection
*
Programming Instructions: (1) Read the label. (2) Read the Serial Number barcode
on the bottom of the desired Xi3000 Base Station within 5 seconds to complete this
setting.
RF Auto Shutdown Duration
*
Programming Instructions: (1) Read the label. (2) Program the desired auto
shutdown duration (in minutes) by reading Decimal Digits on page 52. (3) Read
the “Validate” label (also on page 52) to complete this setting.
Transmit Buffer Setting
Enable
< Disable >
2
Enter Setup
Memory Mode Parameters
•Memory Mode
Enable
< Disable >
•Clear Data
Clear
Confirm
•Send Data
•Memory Data Delay
< 0 >
2 sec
250 ms
3 sec
500 ms
5 sec
1 sec
8 sec

3
Update
List Setting
Page1
Page 6
Page 2
Page 7
Page 3
Page 8
Page 4
Page 9
Page 5
Page 10
Buzzer Settings
< Buzzer Enable>
Buzzer Disable
•Buzzer Frequency
8 kHz
< 4 kHz >
2 kHz
1 kHz
4
Enter Setup
Reading Redundancy Setting
< No Redundancy >
2 Times
3 Times
4 Times
Scan Mode Setting
< Auto Off Mode >
Continuous Mode
Auto Power Off Mode
Alternate Mode
Momentary Mode
Repeat Mode
Laser Mode
Test Mode
Auto-Sense Setting
Enable
<Disable>

5
Update
Scanner Time-out Duration
*
Programming Instructions: (1) Read the label. (2) Program the desired time-out
duration by reading Decimal Digits on page 52. (3) Read the “Validate” label (also
on page 53) to complete this setting.
Negative Barcode Setting
Enable
< Disable >
Delay between Reread
100 ms
1 sec
200ms
2 sec
< 400 ms >
3 sec
800 ms
5 sec
6
Enter Setup
Keyboard Wedge Parameters
•Activate and Select Keyboard Type
*
Programming Instructions: (1) Read the label. (2) Program the desired keyboard
number (shown in the following table) by reading Decimal Digits on page 52. (3)
Read the “Validate” label (also on page 52) to complete this setting.
•Keyboard Table
No. Keyboard Type
1 PCAT (US)
2 PCAT (French)
3 PCAT (German)
4 PCAT (Italy)
5 PCAT (Swedish)
6 PCAT (Norwegian)
7 PCAT (UK)
8 PCAT (Belgium)
9 PCAT (Spanish)
10 PCAT (Portuguese)
11 PS55 A01-1
12 PS55 A01-2
13 PS55 A01-3
14 PS55 001-1
15 PS55 001-81
16 PS55 001-2
17 PS55 001-82
18 PS55 001-3
19 PS55 001-8A
20 PS55 002-1, 003-1
21 PS55 002-81, 003-81
22 PS55 002-2, 003-2
23 PS55 002-82, 003-82
24 PS55 002-3, 003-3
25 PS55 002-8A, 003-8A
26 IBM 3477 (Japanese)
27 PS2-30
28 IBM 34XX/319X, Memorex Telex 122 Keys

7
Update
•Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
•Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
•Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
•Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
8
Enter Setup
•Alphabet Transmission
< Case Sensitive >
Ignore Case
•Digits Transmission
< Alphanumeric Key >
Numeric Key
•Alt Composing
Yes
< No >
•Inter-Character Delay
*
Programming Instructions: (1) Read the label. (2) Program the desired inter-
character delay by reading Decimal Digits on page 52. (3) Read the “Validate”
label (also on page 52) to complete this setting.
•Laptop Support
<Disable>
Enable

9
Update
RS-232 Parameters
•Activate RS232 Interface
•Baud Rate
115200
38400
19200
< 9600 >
4800
2400
1200
Parity
Even
Odd
< No Parity >
•Data Bit
< 8 >
7
10
Enter Setup
•Flow Control (single port only)
< None >
Scanner Ready
Data Ready
INV. Data Ready
•Inter-Character Delay
*
Programming Instructions: (1) Read the label. (2) Program the desired inter-
character delay by reading Decimal Digits on page 52. (3) Read the “Validate”
label (also on page 52) to complete this setting.

11
Update
Bluetooth Serial Port Parameters
•Activate Bluetooth Serial Port Interface
•Device Name Broadcasting
< Yes >
No
•Authentication
Yes
< No >
•PIN Code
*
Programming Instructions: (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 53. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete
this setting. (4) Max 6 characters for this PIN Code setting.
•Power Saving
<Enable>
Disable
12
Enter Setup
Bluetooth HID Parameters
•Activate and Select Keyboard Type
*
Programming Instructions: (1) Read the label. (2) Program the desired
keyboard number (shown in the following table) by reading Decimal Digits on
page 52. (3) Read the “Validate” label (also on page 53) to complete this
setting.
•HID Keyboard Table
No. Keyboard Type
64 PCAT (US)
65 PCAT (French)
66 PCAT (German)
67 PCAT (Italy)
68 PCAT (Swedish)
69 PCAT (Norwegian)
70 PCAT (UK)
71 PCAT (Belgium)
72 PCAT (Spanish)
73 PCAT (Portuguese)
74 PS55 A01-2 (Japanese)
•Reset Connection
Please read this label when switching connection from one PC to another and
the reconnection is needed.
•Device Name Broadcasting
< Yes >
No

13
Update
•Authentication
Yes
< No >
•PIN Code
*
Programming Instructions: (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 53. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete
this setting. (4) Max 6 characters for this PIN Code setting.
•Power Saving
<Enable>
Disable
•Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
14
Enter Setup
•Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
•Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
•Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
•Alphabet Transmission
< Case Sensitive >
Ignore Case

15
Update
•Digits Transmission
< Alphanumeric Key >
Numeric Key
•Alt Composing
Yes
<No>
Prefix / Postfix Settings
Prefix Code *
Postfix Code *
Character Substitution
Set 1 *
Set 2 *
Set 3 *
Programming Instructions: (1) Read the label. (2) Program the desired
character string by reading Hexadecimal Digits on page 53. One character
consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page
53) to complete this setting.
Code ID Selection
•Clear All Code ID Settings
16
Enter Setup
•Select Code ID Set
Set 1
Set 2
Set 3
Set 4
Set 5
Code ID Setting
Code 39 *
Italy Pharmacode *
French Pharmacode *
Industrial 25 *
Interleave 25 *
Matrix 25 *
Codabar *
UPCA *
UPCE *
EAN8 *
EAN13 *
Code 93 *

17
Update
Code 128 *
MSI *
Plessey *
Telepen *
Programming Instructions: (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 53. One character consists of 2
hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete
this setting.
18
Enter Setup
Length Code Setting (2 digits)
•Code 39 Length Code
Enable
< Disable >
•Italy Pharmacode Length Code
Enable
< Disable >
•French Pharmacode Length Code
Enable
< Disable >
•Industrial 25 Length Code
Enable
< Disable >
•Interleave 25 Length Code
Enable
< Disable >

19
Update
•Matrix 25 Length Code
Enable
< Disable >
•Codabar Length Code
Enable
< Disable >
•UPCA Length Code
Enable
< Disable >
•UPCE Length Code
Enable
< Disable >
•EAN8 Length Code
Enable
< Disable >
•EAN13 Length Code
Enable
< Disable >
20
Enter Setup
•Code 93 Length Code
Enable
< Disable >
•Code 128 Length Code
Enable
< Disable >
•EAN128/RSS Length Code
Enable
< Disable >
•MSI Length Code
Enable
< Disable >
•Plessey Length Code
Enable
< Disable >
•Telepen Length Code
Enable
< Disable >

21
Update
Select Readable Codes
•Code 39
< Enable >
Disable
•Italy Pharmacode
Enable
< Disable >
•French Pharmacode
Enable
< Disable >
•Industrial 25
< Enable >
Disable
•Interleave 25
< Enable >
Disable
22
Enter Setup
•Matrix 25
Enable
< Disable >
•Codabar
< Enable >
Disable
•Code 93
< Enable >
Disable
•Code 128
< Enable >
Disable
•EAN128
Enable
< Disable >
•MSI
Enable
< Disable >

23
Update
•Plessey
Enable
< Disable >
•Telepen
Enable
< Disable >
•UPCA
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
24
Enter Setup
•UPCE
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
•EAN8
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >

25
Update
•EAN13
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
•RSS14
Enable
< Disable >
•RSS Limited
Enable
< Disable >
•RSS Expanded
Enable
< Disable >
26
Enter Setup
Code39 Parameters
•Standard / Full ASCII Code39
< Standard >
Full ASCII
•Start / Stop Transmission
Enable
< Disable >
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
Italy Pharmacode Parameters
•Checksum Transmission
< Enable >
Disable

27
Update
French Pharmacode Parameters
•Checksum Transmission
< Enable >
Disable
Industrial 25 Parameters
•Start / Stop Selection
< Industrial 25 >
Interleave 25
Matrix 25
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
28
Enter Setup
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions: (1) Read the label. (2) Program the desired length
by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on
page 53) to complete this setting.
Interleave 25 Parameters
•Start / Stop Selection
Industrial 25
< Interleave 25 >
Matrix 25

29
Update
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
Programming Instructions: (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page
53) to complete this setting.
30
Enter Setup
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions: (1) Read the label. (2) Program the desired length
by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on
page 53) to complete this setting.
Matrix 25 Parameters
•Start / Stop Selection
Industrial 25
Interleave 25
< Matrix 25 >
•Checksum Verification
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable

31
Update
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions: (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page
53) to complete this setting.
Codabar Parameters
•CLSI Conversion
Enable
< Disable >
•Start / Stop Transmission
Enable
< Disable >
32
Enter Setup
Start / Stop Selection
< abcd / abcd >
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
Plessey Parameters
•Convert to UK Plessey
Enable
< Disable >
•Checksum Transmission
< Enable >
Disable
Telepen Parameters
•Telepen Output
< AIM Telepen >
Original Telepen

33
Update
MSI Parameters
•Checksum Verification
< Single Modulo 10 >
Double Modulo 10
Modulo 11 & 10
•Checksum Transmission
< Last digit not Transmitted >
Transmitted
Last 2 Digits not Transmitted
•Max / Min Code Length Qualification
Select Max / Min Length Qualification
Max Length *
Min Length *
Programming Instructions: (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page
53) to complete this setting.
34
Enter Setup
•Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 *
Programming Instructions: (1) Read the label. (2) Program the desired length
by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on
page 52) to complete this setting.
EAN128 Parameters
•Code ID Transmission
Enable
<disable>
•Field Separator
*
Programming Instructions: (1) Read the label. (2) Program the desired
character string by reading Hexadecimal Digits on page 53. One character
consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page
53) to complete this setting.
This manual suits for next models
1
Table of contents
Other POS-X Barcode Reader manuals

POS-X
POS-X ION BLUETOOTH User manual

POS-X
POS-X Xi1000 Owner's manual

POS-X
POS-X ION Short Series User manual

POS-X
POS-X ION BLUETOOTH User manual

POS-X
POS-X ION Linear User manual

POS-X
POS-X EVO Laser User manual

POS-X
POS-X EVO 2D User manual

POS-X
POS-X EVO-SG1-AD User manual

POS-X
POS-X ION Short Range User manual

POS-X
POS-X Xi3000 User manual
Popular Barcode Reader manuals by other brands

Datalogic
Datalogic Magellan 9400i Quick reference guide

Denso
Denso BTH-300BW user manual

Leuze electronic
Leuze electronic BCL 338i Original operating instructions

Intermec
Intermec ScanPlus 1800VT supplementary guide

Opticon
Opticon OPR 3101 quick start guide

RIOTEC
RIOTEC LS6307 USB Programming Quick Guide