Powerfinn PAC 600 User manual

PAC 600
PAC 800
PAC 800 comfort
Installation and User Manual
Advanced Battery Chargers

Table of
contents POWERFINN PAC 600/800.......................2
General....................................................... 2
Installation..................................................3
Operations.................................................. 4
Safety Instructions......................................5
Troubleshooting and repair........................6
Guarantee..................................................6
Appendix A.................................................6
Appendix B................................................. 7
Appendix C................................................. 7
Important Read this manual before installing or operating the battery charger.
It must be ensured that children do not play with the device.
PAC 600
PAC 800 Powerfinn PAC 600 and PAC 800 battery chargers use modern
switching technology. The intelligent micro controller extends the life of
the battery by supervising the charging process. The charger is
compact, lightweight and meets the EU safety and EMC requirements.
General PAC chargers are available for a variety of battery types. The charger
type is indicated on the label attached to the side of the charger.
Be sure to always use the correct type of charger. The charger type
should correspond to the battery construction (sealed, vented, etc.)
Attempting to charge a battery with the wrong type of charger may
result in considerable damage.
Check the battery to ascertain that the “five hour capacity” (in ampere-
hours, Ah5) is between 5 and 14 times greater than the nominal
current (in amperes) of the charger. E.g. a 10A charger is suitable for
charging batteries with a 5-hour capacity of 50Ah-140Ah.
2

Installation The following points must be respected when choosing a location for
the charger.
1. The location must be dry, dust-free and indoors. The acceptable
temperature range for operation is 0°C to +40°C. A higher ambient
temperature will limit the current supply, see appendix A on page 6.
Caution: The charger is not waterproof. Keep the charger dry and
away from areas with high humidity in order to avoid the risk of
electrical shock and damage to the charger.
2. The equipment may be installed horizontally or vertically. The
horizontal position, however, is recommended with a height of 1
meter above floor level.
3. To ensure sufficient ventilation, leave a free space of at least 10 cm
around all sides of the charger. Do not cover the unit.
4. The charging process generates explosive hydrogen gas. Keep the
area well ventilated. Never use an open flame and avoid sparks
close to the battery and charger.
5. The floor and material below the charger must be fire-resistant.
Install the charger using the railed assembly plate (see figure). With
vertical mounting, place the vertical slide barrier downwards. Fasten
the assembly board to the wall using the mounting holes in the back
of the board. Next, place the charger in the assembly board by
inserting the rails at the bottom side of the charger, into the rail
guides. Finally, fasten the charger to the assembly board by using
the small screws on the side of the board. Fix the sticker (see
appendix C), if provided, to the topside of the charger. Plug the main
power cord into an earthed mains outlet.
3

Operations Read these operating instructions before using the charger for the first
time. Read the safety instructions in the next paragraph thoroughly.
To charge a battery with the PAC charger, follow these instructions:
1. Ensure that the charger is switched off and that the work
environment meets the conditions described in the previous
paragraph.
2. Connect the charger cables to the battery terminals: the positive
(+) cable to the positive (+) terminal and the negative (–) cable to
the negative (–) terminal. The positive cable is red and has a
yellow cable marker with a + symbol. The negative cable is black.
The positive battery cable is commonly marked with red.
Warning: Explosive gases. Prevent flames and sparks. Provide
adequate ventilation during charging.
3. Turn the power on by turning the switch to position ‘1’. The fan will
operate when the charger is turned on. The charger continuously
monitors its own temperature level and reacts by controlling the
charging current and fan speed. The charger will not overheat
under normal conditions.
4. Go to step 8 in case the charger is programmed for constant
voltage charging.
5. During the charging process the STATUS LED light is continuously
orange. A constant red color indicates either too low or too high a
voltage, or that the battery is not connected to the charger. Turn
the power off by turning the switch to the ‘0’ position and make
sure that the battery is suitable for the charger. The battery voltage
should be 8-16V for a 12V charger and 16-32 V for a 24V charger.
Check the cable connections and return to step 2.
6. The battery is fully charged as soon the STATUS LED is green.
7. The charger will switch to maintenance charging about 16 hours
after beginning to charge the battery. The process will terminate
and the STATUS LED will flash intermittent red in case the battery
is not fully charged after PAC switches to maintenance charging.
This may occur if the battery has a defect, or if the charger and the
battery are incompatible (see page 2 ‘General’).
8. This step applies only to chargers programmed for constant
voltage charging. During the charging process the STATUS LED
light is continuously orange. The charger does not check the cable
connections and starts charging immediately after the power is
switched on.
9. Always turn the power off before disconnecting the cables by
turning the switch to the ‘0’ position. This avoids heavy sparking.
4

Car use: Always refer to the user manual of the car before connecting
the charger to the car battery (see step 2) and removing it after finishing
charging (see step 5). The battery terminal not connected to the car
chassis has to be connected first. The other connection is to be made to
the chassis far away from fuel lines and from the fuel induction i.e.
carburetor. After finishing charging, unplug the charger from the mains
before removing the charger cables.
Safety
Instructions In addition to the safety measures mentioned under ‘Installation’ (page
3), the following personal precautions should be taken whenever
charging batteries.
1. For emergency situations ensure in advance that help is available in
time of need.
2. Batteries contain acid that is harmful to the eyes, skin and clothes.
Always wear overalls and safety goggles. Never touch the eyes with
unwashed hands after handling batteries.
3. Ensure that a working, fresh water tap is available. If acid gets into
the eyes or on the skin, immediately rinse the area with plenty of
water for several minutes. If visible injury occurs, contact a physician
immediately. In case of eye injuries, always contact a physician.
4. The charging process generates explosive hydrogen gas. Do not
smoke or otherwise bring burning or sparking matter to the vicinity of
the charger when it is in operation.
5. If a short circuit occurs, the battery may explode or the item causing
the short may melt. Keep the work area clear from tools and debris.
Remove jewelry, watches etcetera before working with the battery.
6. The power cord should be unplugged and the battery must be
disconnected from the charger in case the equipment is left unused
for a longer period of time.
7. The charger must be situated away from heat sources like radiators
and heat registers and in such a way that no objects can fall or liquid
can be spilled into the cabinet openings.
8. Never attempt to recharge non-rechargeable batteries.
9. This device is not meant to be used by children or people whose
physical, sensory or mental attributes or lack of experience and
knowledge prevent them from using the device safely unless a
person responsible for their safety supervises them or has instructed
them how to use the device.
5

Trouble–
shooting
and repair
The most common faults are described under ‘Operations’ (page 4).
If the cause of malfunction cannot be found, contact your retailer or the
manufacturer. Only authorized persons can repair the charger.
Guarantee The equipment has a guarantee of two years from the date of purchase.
Guarantee covers manufacturing and component failures and is valid
only if the equipment is installed and used according to the instructions
in this manual.
Keep the receipt as evidence of the date of purchase.
Appendix A The following graphs show the effect of ambient temperature on
output power and fan speed, as well as the effect of input voltage on
output power.
6

Appendix B Example of a front panel label (varies per model).
Appendix C Example of a top label (varies per model)
Note:
Constant voltage chargers do not have DISCONNECTED and
READY markings mentioned on the label.
7

Perämiehenkatu 6
24100 Salo
tel. +358 (0)2 777 290
fax +358 (0)2 777 2918
www.powerfinn.fi
8
This manual suits for next models
2
Table of contents
Other Powerfinn Batteries Charger manuals

Powerfinn
Powerfinn PAC 1600 User manual