CHANGING A NOZZLE
1REMOVING THE NOZZLE RETENTION SCREW
Use your K-Key or a small flat blade screwdriver to remove the nozzle retention
screw by turning counter-clockwise to remove and clockwise to re-install.
2PULL UP THE RISER
Insert the K-Key in the keyhole on the top of the nozzle turret and turn the
key 1/4 turn to insure that the key does not slip out of the keyhole when
you pull it up. Firmly pull up the entire spring-loaded riser to access the
nozzle socket. Hold the riser assembly up with one hand.
3REMOVING THE NOZZLE
With the nozzle retention screw removed, insert the K-Key into the slot
directly under the nozzle “prongs” at the top of the nozzle. Now, turn the key
1/4 turn to “hook” the nozzle and pull the nozzle out.
4INSTALLING A NOZZLE
Press the desired nozzle into the nozzle socket. Make sure the nozzle
number is visible and the nozzle “prongs” are up. Then, re-install the
nozzle retention screw. NOTE: The nozzle retention screw is also a
break-up screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
1FINDING THE LEFT START POSITION
Place your finger on the top center of the nozzle turret. Rotate the turret
to the right until it stops and then back to the left until it stops. Notice the
position of the nozzle arrow. This is the “Left Start” position. The sprinkler
will begin spraying from this position and rotate clockwise until it reaches
the right Adjustable Stop-Return Point.
2ORIENTING THE LEFT START POSITION
Insert the K-Key in the keyhole on the top of the nozzle turret and turn the
key 1/4 turn to insure that the key does not slip out of the keyhole when
you pull it up. Being careful not to allow the nozzle turret to turn, firmly pull
up the entire spring-loaded riser. Hold the lower riser assembly up with one
hand. Now turn only the lower riser clockwise or counter-clockwise until the
nozzle arrow is pointing where you want the sprinkler to begin spraying.
3CHANGING THE ARC
Insert the K-Key or a small flat blade screwdriver into the Arc Set Adjustment
slot. Turn clockwise to increase the arc or counter-clockwise to decrease the
arc. NOTE: The arc set arrow in the center of the nozzle turret rotates to
show the current setting. WHEN SET AT 360°, THE SUPER
PRO
WILL
ROTATE CONTINUOUSLY IN A CLOCKWISE DIRECTION.
4OPERATING THE SHUT OFF
To shut off the water flow insert your K-Key into the flow shut-off slot and
turn counter-clockwise. During system operation, the riser will remain
elevated. To open flow again, turn key clockwise.
NOTE: The Super
Pro
is factory preset with a 90° arc setting, and includes a pre-installed #2.5 nozzle.
S075 S
TWIST-LOCK
TOP
SPRINKLER
ASSEMBLY
HOUSING
CAN
STANDARD NOZZLE PERFORMANCE LOW ANGLE NOZZLE PERFORMANCE
SPRINKLER INSTALLATION
1INSTALL AND BURY
Do not use pipe dope.Thread the sprinkler on the pipe. Bury the
sprinkler flush to grade. NOTE: Gear driven sprinklers and pop-up
sprays should not be installed on the same watering zone.
2INSPECTING THE FILTER
Unscrew the top and lift the complete sprinkler assembly out of the
housing can. The filter is located on the bottom of the sprinkler
assembly and can easily be pulled out, cleaned and re-installed.
3WINTERIZATION TIPS
When using an air compressor to remove water from the system
please note the following:
1) Do not exceed 30 PSI.
2) Always introduce air into the system gradually to avoid air
pressure surges. Sudden release of compressed air into the
sprinkler can cause damage.
3) Each zone should run no longer than 1 minute on air. Sprinklers
turn 10 to 12 times faster on air than on water. Over spinning
rotors on air can cause damage to the internal components.
S075 S GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS
METRIC
Pressure Radius Flow
KPa Bars Meters L/M M
3
/H
207 2.1 10.7 9.46 .57
276 2.8 11.0 10.60 .64
345 3.4 11.3 12.11 .73
414 4.1 11.6 13.63 .82
207 2.1 9.1 1.70 .10
276 2.8 8.8 1.89 .11
345 3.4 7.9 2.27 .14
414 4.1 7.9 2.65 .16
207 2.1 9.8 2.65 .16
276 2.8 9.8 3.03 .18
345 3.4 10.1 3.41 .20
414 4.1 10.1 3.79 .23
207 2.1 9.1 4.16 .25
276 2.8 9.8 4.92 .30
345 3.4 10.1 5.68 .34
414 4.1 10.1 6.06 .36
207 2.1 11.6 8.71 .52
276 2.8 11.6 9.46 .57
345 3.4 12.2 10.22 .61
414 4.1 12.8 11.36 .68
207 2.1 10.7 12.87 .77
276 2.8 11.0 14.38 .86
345 3.4 11.6 15.90 .95
414 4.1 11.9 18.17 1.09
207 2.1 12.8 15.52 .93
276 2.8 13.4 17.41 1.04
345 3.4 13.7 19.31 1.16
414 4.1 14.0 21.58 1.29
276 2.8 14.0 21.96 1.32
345 3.4 14.6 24.23 1.45
414 4.1 14.9 26.50 1.59
483 4.8 14.9 28.39 1.70
276 2.8 12.8 28.39 1.70
345 3.4 13.7 31.04 1.86
414 4.1 14.6 34.07 2.04
483 4.8 14.6 35.96 2.16
U.S.
Nozzle Pressure Radius Flow
PSI Ft. GPM
#2.5
Factory
Installed
Nozzle
#0.5
#0.75
#1
#2
#3
#4
#6
#8
METRIC
Pressure Radius Flow
KPa Bars Meters L/M M
3
/H
207 2.1 7.9 4.92 .30
276 2.8 8.2 5.68 .34
345 3.4 8.2 6.44 .39
414 4.1 8.5 7.19 .43
207 2.1 8.8 10.98 .66
276 2.8 9.1 12.49 .75
345 3.4 9.4 12.87 .77
414 4.1 10.1 15.14 .91
207 2.1 8.5 15.14 .91
276 2.8 9.4 17.79 1.07
345 3.4 10.4 18.93 1.14
414 4.1 11.0 22.71 1.36
207 2.8 9.1 22.71 1.36
276 3.4 10.4 26.50 1.59
345 4.1 11.3 29.53 1.77
414 4.8 11.6 31.04 1.86
U.S.
Nozzle Pressure Radius Flow
PSI Ft. GPM
#1 30 26' 1.3
40 27' 1.5
50 27' 1.7
60 28' 1.9
#3 30 29' 2.9
40 30' 3.3
50 31' 3.4
60 33' 4.0
#4 30 28' 4.0
40 31' 4.7
50 34' 5.0
60 36' 6.0
#6 40 30' 6.0
50 34' 7.0
60 37' 7.8
70 38' 8.2
30 35' 2.5
40 36' 2.8
50 37' 3.2
60 38' 3.6
30 30' .45
40 29' .5
50 26' .6
60 26’ .7
30 32' .7
40 32' .8
50 33' .9
60 33’ 1.0
30 30' 1.1
40 32' 1.3
50 33' 1.5
60 33' 1.6
30 38' 2.3
40 38' 2.5
50 40' 2.7
60 42' 3.0
30 35' 3.4
40 36' 3.8
50 38' 4.2
60 39' 4.8
30 42' 4.1
40 44' 4.6
50 45' 5.1
60 46' 5.7
40 46' 5.8
50 48' 6.4
60 49' 7.0
70 49 7.5
40 42' 7.5
50 45' 8.2
60 48' 9.0
70 48 9.5

Other Rain Irrigation System manuals

Rain AMICO+ User manual

Rain

Rain AMICO+ User manual

Rain C-dial Compact User manual

Rain

Rain C-dial Compact User manual

Rain SO50 Operating manual

Rain

Rain SO50 Operating manual

Rain S050 S Operating manual

Rain

Rain S050 S Operating manual

Rain i-dial User manual

Rain

Rain i-dial User manual

Rain PROSPORT KRN02210 Operating manual

Rain

Rain PROSPORT KRN02210 Operating manual

Rain PRESSURE ZERO 094 HSB4068 User manual

Rain

Rain PRESSURE ZERO 094 HSB4068 User manual

Rain Click User manual

Rain

Rain Click User manual

Rain SO75 Operating manual

Rain

Rain SO75 Operating manual

Rain elite 9 VDC User manual

Rain

Rain elite 9 VDC User manual

Rain ACQUA CLICK User manual

Rain

Rain ACQUA CLICK User manual

Rain Click Plus User manual

Rain

Rain Click Plus User manual

Rain S-Dial User manual

Rain

Rain S-Dial User manual

Popular Irrigation System manuals by other brands

Tyco Rapidresponse LFII Series manual

Tyco

Tyco Rapidresponse LFII Series manual

Viking VK638-D Technical data

Viking

Viking VK638-D Technical data

Toro XP300-02 Installation and service instructions

Toro

Toro XP300-02 Installation and service instructions

Triad DamSurge Valve Operator's manual

Triad

Triad DamSurge Valve Operator's manual

Reliable Pantman F1 manual

Reliable

Reliable Pantman F1 manual

Tyco Fire Product Gem FR-1 instruction manual

Tyco Fire Product

Tyco Fire Product Gem FR-1 instruction manual

ATIKA VT 36 manual

ATIKA

ATIKA VT 36 manual

Toro 53763 Installation and operating instructions

Toro

Toro 53763 Installation and operating instructions

TriangleTube WASTEFLOW Installation & maintenance manual

TriangleTube

TriangleTube WASTEFLOW Installation & maintenance manual

Brandson Equipment 304257/20191212NB128 user manual

Brandson Equipment

Brandson Equipment 304257/20191212NB128 user manual

Autopot easy2grow 24 Set-up guidelines

Autopot

Autopot easy2grow 24 Set-up guidelines

Solem LoRa LR-BST-25 installation guide

Solem

Solem LoRa LR-BST-25 installation guide

Perrot LVZX 30 Operation manual

Perrot

Perrot LVZX 30 Operation manual

Reliable RFS42 Bulletin

Reliable

Reliable RFS42 Bulletin

AQUAvalve 6Pot XL Set-up guidelines

AQUAvalve

AQUAvalve 6Pot XL Set-up guidelines

Tyco Fire Product CENTRAL Optima instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL Optima instruction manual

Viking Microfast M Technical data

Viking

Viking Microfast M Technical data

Eden 96212EDAMZ quick start guide

Eden

Eden 96212EDAMZ quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.