INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISGEO
IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefulnottotouchthepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajar’in
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbodyandbecoming
damaged.

ENGLISH RAISmanualforRaisGeo
2

ENGLISH RAISmanualforRaisGeo
3
INTRODUCTION...………………………………………………………….. 4
WARRANTY..…………………………………………………….………….. 4
SPECIFICATIONS………………………………………………………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION……………………………………………………………... 10
INSTALLATIONWITHTURNTABLE….…………………………………. 1119
INSTALLATIONDISTANCETOCOMBUSTIBLEWALL……………… 20
CORNERINSTALLATION45°…………….………………………………. 21
INSTALLATIONDISTANCETONONCOMBUSTIBLEWALL………. 22
FORTHEINSTALLER……………………………………………………… 23
OPERATINGINSTRUCTIONS…………………………………………….. 24
FUEL…………………………………………………………………………... 24
DRYINGANDSTORAGE…………………………………………………… 25
REGULATIONOFCOMBUSTIONAIR…………………………………… 26
USINGTHEWOODBURNINGSTOVE…………………………………… 27
ADJUSTMENTOFAIRDAMPER…………………………………………. 27
CONTROL…………………………………………………………………….. 27
FIRSTUSAGE………………………………………………………………… 28
LIGHTINGANDFUELLING………………………………………………… 2930
CLEANINGANDCARE…………………………………………………….. 31
CLEANINGOFTHEFLUEWAYS………………………………………… 32
PROBLEMSOLVING……………………………………………………….. 33
ACCESSORIESANDSPAREPARTS……………………………………. 34
SPAREPARTDIAGRAMRAISTOPAS…….………...…………………. 3435
SPAREPARTDIAGRAMRAISOPUS……....…………………………… 3637
Revision:
Date :2011
RaisGeo

ENGLISH RAISmanualforRaisGeo
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectionbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonly.

ENGLISH RAISmanualforRaisGeo
5
RAISGEO161 RAISGEO126
Nominaloutput(kW): 5 5
Min./Max.output(kW): 38 38
Heatingarea(m
2
): Approx100 Approx100
Size,width/depth/height(mm): 490/490/1610 490/490/1260
Combustionchamberwidth/depth/height(mm). 288/288/500 288/288/500
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2 3logsofwoodapprox.25cm)
1.6 1.6
Min.uptake/Min.draught(Pascal): 12 12
Weight(kg): 450 450
Efficiency(%): 79 79
ParticlesafterNS3058/3059(g/kg): 3.95 3.95
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 5 5
Smokegastemperature(°C): 274 274
Intermittentoperation: Fuellingshouldbeundertaken
within3hours
Specifications

ENGLISH RAISmanualforRaisGeo
6
Thestovesareequippedwithcooldoorhandles aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse sotakeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.

ENGLISH RAISmanualforRaisGeo
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandproperinstallationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingtherelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipment.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).

ENGLISH RAISmanualforRaisGeo
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdraught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbeused,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallationofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustiblematerialgiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.

ENGLISH RAISmanualforRaisGeo
9
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatthereisafreeflowthrough
areaofminimum20cm
2 whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptclear.

ENGLISH RAISmanualforRaisGeo
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairoutlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.

ENGLISH RAISmanualforRaisGeo
11

ENGLISH RAISmanualforRaisGeo
12
1 Locatethestovewhereitistobeinstalled,itcannotbemovedoncethe
soapstonehasbeeninstalled.
A Therearflueconnectioncanbeinstalledafterthethirdrowofsoapstone
hasbeenpositioned(Geo161only).
B Fortopflueconnection,removethemarkedopeningwithaplasticor
rubberhammer.
C Installationuptotheceiling,theeasiestoptionistousetheRaissliding
fluesystemandadaptor.Thesteeltopplateshouldbepushedontothe
fluepipe.
2 Adjustthelegssothattheyarelevel.
Loosenthecounterscrew.
Adjusttheleg.
Tightenthecounterscrew.
3 Positionthesoapstoneasshownonthediagramandscrewthemtogether
withtheenclosedmountings.
Dependingonthechoiceofflueoutlet,youareleftwithonepieceof
soapstone,eithernumber7023or7033/7036.
4 Insertthefirebox.
A Ensurethatthefireboxiscentredwithinthestovebody,itmustNOT
touchthesoapstone.
B Ifyouareusingtherearflueoutletoption,ensurethattheexitholesare
aligned.

ENGLISH RAISmanualforRaisGeo
13
5 Withanexternalairconnection;
Mounttheairsupplyatthebottomofthestovewithaflexiblehoseanda
clamp.
6 Withoutanexternalairconnection;
Fittheventgrille(seestep5onpage16)

ENGLISH RAISmanualforRaisGeo
14

ENGLISH RAISmanualforRaisGeo
15

ENGLISH RAISmanualforRaisGeo
16

ENGLISH RAISmanualforRaisGeo
17

ENGLISH RAISmanualforRaisGeo
18

ENGLISH RAISmanualforRaisGeo
19

ENGLISH RAISmanualforRaisGeo
20
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisionsofthecurrentUKBuildingRegulationsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJandalsoin
Other manuals for GEO
1
This manual suits for next models
2
Table of contents
Other RAIS Wood Stove manuals
Popular Wood Stove manuals by other brands

Drolet
Drolet DB03081 Installation and operation manual

Lopi
Lopi Patriot owner's manual

Hardy
Hardy LC300 Installation and operating instructions

Drolet
Drolet Savannah DB03020 Technical data

IronStrike
IronStrike Tahoma 2100GL Installation and operation manual

Dovre
Dovre 350CB Installation instructions and operating manual

Teba
Teba TKS-15 installation manual

Beltane Stoves
Beltane Stoves HOLFORD Installation and operating instructions

HearthStone
HearthStone Phoenix 8612 owner's manual

Mendip Stoves
Mendip Stoves Christon 550 Operation and installation manual

Travis Industries
Travis Industries Leyden 250-00622 manual

Breckwell
Breckwell SP24 owner's manual