This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.
Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.
Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.
Important Safety Instructions
A. Remove the pole top cover.
C. Align and fasten the fitting to
the pole through the locating
holes either at 0º or at 15º. Once
securely fastened, align and
fasten the pole top cover.
B. Using the electrical tail
supplied from the fitting, feed
the cable through the locating
hole on the top of the pole,
down the pole to the access
door.
2 . R e c o m m e n d e d b e f o r e
installing (burying) the pole into
the ground.
C. Replace the access door via the
four stainless steel fasteners using an
allen key.
B. Connect the cable from the fitting
in the pole to the connector block
through the access door.
4. A. Remove the access door via
the four stainless steel fasteners using
an allen key.
Cable entry
Mounting
holes
Replace the glass via the four stainless
steel screws. Ensure there is no exposed
conductors or loose strands.
Ensure the new LED is the correct
w a t t a g e , a c c o r d i n g t o t h e
specification and is securely located on
the mounting surface.
Ensure that the gasket is securely in
place.
6. To install or change the LED, unscrew
the four stainless steel screws on the
glass and remove the glass from the
fitting, and allow the glass to hinge on
the securing cable.
7. Switch on the power
supply.
Post top light
direction
Access door
direction
A
B
C
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Wire Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
Pole
Ground
Level
6
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Wire Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
Ensure the electrical cable
tail is fed through the pole
and base plate.
3. Assemble the base plate
(supplied) to be buried in the
ground, using the stainless
steel hook bolts and nuts
(supplied).
Hook the two hook bolts into
the allocated holes on the
pole. Slide the blank base
plate onto the hook bolts at
the bottom of the pole. Align
and fasten the hook bolts
using the nuts.
x2 Hook bolts
Blank base plate
Bolt hook nuts
A
B
C
Remove access door.
A
Connect power
to the tting.
To Luminaire
Mains power
B
L N
Replace access door.
C
4. Remove the access door. Feed
the ca ble from the gr ound
through the glands at the bottom
of the fitting to the access door.
Connect the Switched Live (S/A),
Neutral (N) and Earth (E) cable(s)
to the MCB and connector block
in the access door.
NEUTRAL – (Black or Blue) to
terminal marked N
EA RT H – (G re en /Ye ll ow ) to
terminal marked.
SWITCHED LIVE – (Red or Brown)
to terminal marked L