Rehatec Galileo User manual

English
INSTRUCTIONS FOR USE
SERIAL NUMBER::
Galileo
Mobility Base
1024081_EN_1

Rehatec® GmbH
In den Kreuzwiesen 35
69250 Schönau
Germany
Tel.: 06228 / 91 36 0
Fax: 06228 / 91 36 99
www.rehatec.com
© 2023 Rehatec® GmbH
Technical changes and rights reserved. Valid since 12.01.2023 - Rev. 1024081_1

1024081_EN_1 Subject to technical changes and printing errors.
Foreword
Dear user,
We are pleased that you have chosen a high-quality product from Rehatec® GmbH and thank you for your
trust.
These instructions are intended to help you familiarise yourself with your Galileo mobility base and show
you how to handle it easily and quickly in daily use for various applications. All you have to do now is adjust
your mobility base optimally and you are ready to go. Then you can enjoy its use for a long time.
Please note that the illustrations and information in these operating instructions may dier from your pro-
duct due to the individual equipment options.
We reserve the right to make technical changes and improvements. These operating instructions have been
prepared with the greatest care. Nevertheless, errors cannot be completely ruled out. Rehatec® GmbH does
not accept any liability in this case.
Your Rehatec® GmbH wishes you much pleasure in using your Galileo mobility base.
Important!
Read these instructions for use carefully before using your new Galileo mobility base for the rst time. Peo-
ple with impairments, be it sensory impairments, cognitive impairments or learning disabilities, can have the
instructions for use translated for comprehensibility if necessary. This can be done, for example, by reading it
aloud, translating it into easier language or having additional explanations provided by third parties.
The operator must have read and understood the complete instructions for use.
In order not to compromise the safety of the user, the operator must not have any impairment that tempora-
rily or permanently impairs attention and judgement.
Keep the instruction manual handy for later use and ensure that it remains with the product. If lost, we will be
happy to send you another copy.
In addition, it is possible to download the instructions for use from our website www.rehatec.com as well as
downloading them.
Characters
Attention!
Indicates notes that are particularly relevant to safety.
Important!
Denotes particularly useful information in the respective subject context.
3 from 60

1024081_EN_1 Subject to technical changes and printing errors.
Table of contents
Inhalt
1. Safety 6
1.1 Safety instructions 6
2. Intended use 9
2.1 Purpose / scope of application 9
2.2 Responsibility 10
2.3 Declaration of conformity 10
2.4 Care and maintenance 11
2.4.1 Maintenance 11
2.4.2 Inspection plan 12
2.4.3 Cleaning and disinfection 14
2.5 Further use 18
2.5.1 Reuse or reprocessing 18
2.5.2 Disposal 18
2.6 Warranty and service 19
2.6.1 Warranty conditions 19
2.6.2 Service/ Complaints 19
3. Product and delivery overview 20
3.1 Scope of delivery 20
3.2 Accessories 21
3.3 Delivery inspection 21
4. Unit settings 22
4.1 General driving characteristics 22
4.2 User shifts the centre of gravity 24
4.3 Transport in motor vehicles 25
4.4 Drive wheel 27
4.5 Front castor 28
4.6 Front castor stop (optional) 28
4.7 Alignment of the drive wheel 29
4.8 Wheelbase 29
4.9 Wheel guard (optional) 30
4.10 Spokeguard (optional) 30
4.11 Drum brake 31
4.12 Parking brake on drive wheel (optional) 32
4.13 Tilting the seat 33
4.14 Back angle adjustment 33
4.15 Foldable back 34
4.16 Adjusting the seat depth through backrest 35
4.17 Seat height adjustment 35
4.18 Push bar 36
4.19 Split back mounting bracket for seat shell (optional) 37
4.20 Tip assist (optional) 37
4.21 Anti-tip (optional) 38
4.22 Footplate (optional) 39
4.23 Calf pad (optional) 40
4 from 60

1024081_EN_1 Subject to technical changes and printing errors.
4.24 Trapezoid adapter (optional) 40
4.25 Seating system (optional) 41
4.25.1
Back element without connecting hinge 41
4.25.2 Seat element without connecting hinge 41
4.25.3 Extending the seat element to the rear 42
4.26 Outdoor front wheel accessory, incl. wheel chocks 43
4.27 Dynamic back 44
4.28 Armrests standard 45
4.29 comfort armrests 46
4.30 Flip-up leg control pads 48
4.30.1 Split footplate 48
4.30.2 How to ip the leg control pads up mechanically 49
4.30.3 Split plastic or aluminium footplates 49
4.30.4 Calf pads with ip away bracket 50
4.30.5 Flip-up split footplate, special version 51
4.31 Vent tray for medical devices 51
4.31.1 Adjusting the vent tray for medical devices 51
4.31.2 Tiping bar for vent tray 53
4.31.3 Anti-tip (optional) 53
5. Technical data 54
5.1 Product dimensions 54
6. Product label 55
6.1 Product label 55
5 from 60

1024081_EN_1 Subject to technical changes and printing errors.
1.1 Safety instructions
Please follow all instructions in this manual carefully. Incorrect operation can impair important functions.
All safety instructions and other regulations must always be observed by both the patient and the user.
General
DANGER The mobility base may only be used by someone who has received an introduction and has
1. Safety
read and understood the complete instructions for use! The instruction must be given by the operator/
service provider!
DANGER The user must not have any impairments that temporarily or permanently limit attention and
judgement!
DANGER The patient must never be left unattended. Therefore, constant supervision by an adult car-
egiver (user) is required!
CAUTION The individual limitations and abilities of the patient must be taken into account at all times!
WARNING The maximum permissible load must not be exceeded (see chapter "5. Technical data")!
WARNING The mobility base is only approved for the use of one patient!
DANGER The patient must be appropriately secured against falling out without restricting their sitting
comfort!
WARNING The surfaces of the mobility base can heat up due to heat input. There is a considerable risk
of burns if the temperature exceeds 40°C! To protect the patient from burns, the device must be kept
away from heat sources (e.g. replaces) and strong sunlight!
DANGER The mobility base may only be loaded at the seat, back and foot area. Excessive loading due
to incorrect handling ( e.g. by attaching objects, supporting or leaning against etc.) can lead to a possi-
ble risk of tipping over!
DANGER In case of extreme adjustments and unfavourable body posture (e.g. due to the patient being
lifted too far out of the mobility base), there is an increased risk of tipping over! It is therefore very im-
portant that the patient is positioned in the therapy chair by means of any straps!
CAUTION When sitting down or standing up, do not put excessive strain on the footrest!
There is then an increased danger of tipping over!
CAUTION Additional safety instructions of individual points under "4. Unit settings" must be strictly
observed!
WARNING Never carry or transport the unit with the patient sitting in it!
CAUTION For transport or storage of the unit, plug-in and unattached parts should be packed sepa-
rately. This is the only way to ensure that the product and parts are protected from external inuences!
CAUTION It is essential to keep any packaging lm away from children! Otherwise there is a
considerable risk of suocation!
6 from 60

1024081_EN_1 Subject to technical changes and printing errors.
CAUTION Repair and adjustment work may only be carried out without the patient sitting in the unit!
CAUTION Before each use of the unit, all settings must be made in a patient-friendly manner. Before
each use, check that all parts are securely fastened!
CAUTION All settings must be checked at regular intervals. All screw connections must be checked for
tightness. Wheels must be checked regularly!
CAUTION Never use force during adjustment work, as improper handling can cause damage to the
unit!
WARNING Any combinations of the mobility base with third-party products are not permitted and
can be dangerous. The manufacturer accepts no liability for damage and/or complications due to such
combinations!
WARNING Any electrical components of the unit must not be opened or changed without the permis-
sion of the manufacturer!
WARNING In the event of defects, damage or modications, the unit must not be used and must there-
fore be withdrawn from circulation!
WARNING In case of irregularities of the electric drive, the unit must not be used any further!
DANGER If unusual odours or noises occur when charging or using the electric drive, the unit must not
be used any longer! The unit must be taken out of circulation!
CAUTION During all repair and adjustment work, attention must be paid to the danger of pinching and
crushing!
CAUTION Repair and inspection work may only be carried out by Rehatec® GmbH or operators/care
providers!
CAUTION Maximum adjustment ranges must not be exceeded. It must be possible to guarantee a
secure connection of the parts!
CAUTION Maintenance must be carried out at the prescribed intervals by the operator/care provider (see
chapter "2.4.3 Maintenance intervals").
Settings/ Functions
7 from 60

1024081_EN_1 Subject to technical changes and printing errors.
Environment/ Operation
WARNING The use of the mobility base is only possible at an ambient temperature of 15°C to 35°C!
CAUTION The mobility base must be protected from moisture!
DANGER The mobility base may only be used on rm, level and horizontal ground!
CAUTION The mobility base may only be stored indoors at an ambient temperature of 10° to 50°C!
WARNING The mobility base must be secured against rolling away by applying all parking brakes!
WARNING A possible risk of tipping and slipping due to a change in the suboor condition (wood, carpet,
stone oor and tiles, etc.) must be taken into account!
WARNING If manoeuvrability is limited on soft ground, e.g. on carpeted oors, there is an increased risk of
tipping over!
DANGER Pushing the mobility base over a laterally sloping oor may only be done without a patient!
CAUTION If the mobility base comes into contact with moisture, it must not be used. Immediate drying must
then be ensured (e.g. dry with an absorbent cloth)!
CAUTION If the unit is used in combination with an electric drive, it must not be cleaned with a pressure washer
or steam cleaner!
DANGER Do not immerse any electrical components in water!
DANGER To avoid the risk of re, the device must never be used near or in connection with ammable substan-
ces and re-causing objects!
CAUTION Upholstery, wooden and plastic parts installed on the unit are not ame-retardant. It is therefore
essential that the mobility base is kept away from smoking utensils, replaces, chimney pipes, cookers and
other room heaters.
DANGER Additional objects on the mobility base, e.g. cloths, cushions, blankets, paper and magazines, toys,
etc. can increase the risk of re!
DANGER Never use the mobility base as a climbing aid!
DANGER Children who are playing must not pull themselves up on the mobility base! There is a considerable
risk of tipping over!
DANGER Keep children away from all electronic components at all costs!
DANGER Make sure that no one can injure or strangle themselves by any cables!
8 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.1 Purpose / scope of application
Purpose
The Galileo mobility base is used in general living areas, in care homes as well as in domestic situations. It
is designed to accommodate seating shells or seating systems in order to support therapeutic applications
for people with moderate to severe sitting malpositions and/or sitting posture instabilities, thereby enabling
pain-free sitting in a physiologically correct posture.
Scope of application
The mobility base is used in the general living area, in the care area as well as in the domestic area. It is inten-
ded for indoor and outdoor use. The device must also be kept away from heat sources and strong sunlight -
risk of burns! Failure to observe this can lead to considerable damage and endanger both the patient and the
user. In the event of improper use beyond the prescribed range, the warranty promise or product liability will
be void.
In order to ensure safe and successful operation for the user of Rehatec® GmbH devices, all notes, precau-
tions and information in these instructions for use must be observed.
Rehatec® GmbH gives no guarantee regarding the suitability of this product for a specic therapeutic and
diagnostic purpose. The user determines the sensible use.
User groups: User, operator/care provider and patient
Users do not need any specic skills, but they must be instructed in the proper use of the device.
The instruction is provided by the corresponding operator/care provider. The operator/care provi-
der, in turn, must be able to provide evidence of corresponding training on the respective product.
The individual abilities and limitations of the respective patient shall always be considered.
Never leave the patient unattended!
Indications
Galileo is used to hold a seat shell or a seat system that is used for dierent diseases such as:
Infantile cerebral palsy, myelodysplasia, muscular dystrophy and diseases with scoliotic vertebral column
deformities.
Contraindications
Before adapting the mobility base to the patient, a doctor should clarify whether there are any contraindi-
cations. The indications for the treatment must be monitored by a doctor or therapist at regular intervals.
In general, any kind of pain is a contraindication! Under the following circumstances and/or symptoms, the
active and/or passive use of the device must be explicitly claried with the attending physician or therapist.
2. Intended use
9 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.2 Responsibility
The operator is responsible for the intended use as well as for maintenance and care of the product. Product
modications, repairs, maintenance work and extensions shall only be carried out by authorised persons.
Only original spare parts and accessories shall be used.
Rehatec® GmbH only provides a warranty if the product is used under the specied conditions and for the
intended purposes (see also chapter "9 Warranty and service").
2.3 Declaration of conformity
The corresponding declaration of conformity is available at www.rehatec.com under "Downloads". The CE
mark must be removed if the Rehatec® product is converted, modied or used in combination with unautho-
rised products from other manufacturers. The CE mark also expires if original Rehatec® spare parts/accesso-
ries are not used.
10 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.4 Care and maintenance
The user is responsible for regular maintenance and care.
2.4.1 Maintenance
Never use a unit that is not in perfect condition!
In case of excessive wear or if worn product parts are not replaced, the safety of the product may no
longer be guaranteed!
Faults, malfunctions or defects shall only be repaired by the manufacturer or the operator/care
provider!
Do not make any changes to the product!
In case of complaints or problems, please contact your care provider/operator!
Only use original spare parts/accessories or those approved by Rehatec® GmbH!
Before each use
Please check the following functions before each use:
• All connecting parts and components required for the supply. You can treat moving parts/mechanisms with
a Teon spray (dry lubricant) and wipe o excess residue with a soft cloth.
• The functions of the drum brakes.
During use
• It is important that all components are undamaged during use. Check them regularly and have them re-
paired or replaced if necessary.
The Galileo mobility base must be serviced every 12 months, taking into account any earlier
pre-increasing maintenance intervals, in accordance with the following inspection plan!
11 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.4.2 Inspection plan
Inspections must be carried out by the operator/care provider and documented on the copy. This
document is associated with the device and serves as proof in the event of reuse and when clai-
ming warranty services. Please keep it together with the instructions for use.
Inspection Plan
Galileo Mobility Base
Page 1
21-05-11
Rehatec® GmbH, In den Kreuzwiesen 35, 69250 Schönau, T: +49 6228 9136-0, F: +49 6228 9136-99, info@rehatec.com, www.rehatec.com
Product
Operator
Serial number Maintenance interval
Pos. Assembly Settings
& functions
Damage
& deformation
Bolted
joints
no
defects
defects
found
no
defects
defects
found
no
defects
defects
found
1Frame Standard frame, abducted
Closed frame, abducted
Anti-tip
Tipping bar
Parking brakes/knee lever brakes
Brake with extension lever
Wheel base extension
Castor wheeks with wheel forks and castor stems
Castor wheel stop
Width extension kit for castor wheels
Drive wheels with drum brake carrier and hand
brake levers
Quick-release axles
Spoke guards
Width extension kit for drive wheels
Wheel guards
Seat tilting via gas spring
One-hand operation of seat tilting
Steering device and push aid incl. wheel chocks
Mudguards for steering device and push aid
Wheelchair-tiedown and occupant-restraint system
Transport fittings
Bracket for holding scala-/viamobil
scalamobil anti-tip
2Seat Seat plate
Trapezoidal adapter
Footplate mounting
12 months
12 from 60

1024081_EN_1 Subject to technical changes and printing errors.
You can nd an inspection plan that can be lled out interactively on our homepage
under "Downloads".
Inspection Plan
Galileo Mobility Base
Page 2
21-05-11
Rehatec® GmbH, In den Kreuzwiesen 35, 69250 Schönau, T: +49 6228 9136-0, F: +49 6228 9136-99, info@rehatec.com, www.rehatec.com
Inspection completed on Inspection completed by Signature
Pos. Assembly Settings
& functions
Damage &
deformation
Bolted
joints
no
defects
defects
found
no
defects
defects
found
no
defects
defects
found
Notes on repairs and maintenance
Seating element
Back element
Connecting hinge
Extension of the seating element
Universal bracket
Headrest, shell-shaped
3 Back Back adjustment, mechanical
Back adjustment via gas spring
Push bar, angle-adjustable
Dynamic back
Mounting device with a split, fixed bracket
Mounting device with a split, adjustable bracket
Standard armrests
Comfort armrests
4Feet Footplate
Light-weight footplate
Footplates, parted
Foot angle, adjustable
Folding mechanism
Heel loop
Calf support
Calf supports, split
Flip-up foot rests, standard
Flip-up foot rests, special
Heel loop for flip-up foot rests
13 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.4.3 Cleaning and disinfection
The user is responsible for regular maintenance and care.
In case of complaints or problems, please contact your care provider/dealer!
2.4.3.1 Safety instructions for cleaning and disinfection
DANGER Cleaning or disinfection that is neglected, inadequate or carried out incorrectly (using the
wrong agents or procedures) can pose a serious risk to the user and patient!
DANGER Maintenance, cleaning, repair and adjustment work shall only be carried out without the
patient sitting in the unit!
DANGER When cleaning and disinfecting, pay attention to the residues of the agents used in order
to avoid poisoning, irritation or allergic reactions!
CAUTION Do not use abrasive agents and cloths for cleaning the device!
WARNING Care and safety instructions for the use of the respective cleaning/disinfection agents
shall be observed!
WARNING Very dirty, cracked, holey and contaminated foam parts that have an
adhesive bond to any support element shall be replaced. Cleaning is not possible for these parts!
CAUTION Do not use cleaning agents with solvents if they can aect the structure and consistency
of wood, wooden surfaces and paint coatings, foam/plastics, plastic surfaces (benzene, toluene,
acetone, etc.) and metal paints or coatings.
CAUTION The product and accessories shall not be cleaned with a machine.
CAUTION The product and accessories are not intended to be cleaned with a pressure washer or
steam cleaner, regardless of whether you spray, wash or apply compressed air to them.
CAUTION Do not use germicides or irradiation for disinfection purposes if the irradiation may have
a direct eect on wood, plastics and metals as well as their surfaces and coatings.
CAUTION Dilution and dosing of cleaning agents and disinfectants is only permitted in accordance
with the instructions of the respective manufacturer!
CAUTION All soft and textile components must be dismantled before basic cleaning!
CAUTION After cleaning or disinfection, all soft and textile parts must be completely dry before
they are reattached to the unit!
14 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.4.3.2 General cleaning and disinfection process
DANGER Cleaning or disinfection that is neglected, inadequate or carried out incorrectly (using the
wrong agents or procedures) can pose a serious risk to the operator and patient! Before selecting a
cleaning agent, please contact your dealer.
Basic cleaning before rst use
• When unpacking the unit, visually inspect all visible surfaces for dirt, damage or unknown substances.
• Each unit must be completely cleaned (with accessories) and disinfected before rst use.
• Thereafter, the device and accessories should be subjected to a basic cleaning at least every 2-4 weeks or
as required.
• Always consult the detergent manufacturer for advice on the choice of detergent and its dilution according
to the table of materials below.
Part of the unit Material
Castors ABS, S-Z, PA 66, TPE
Frame and metallic components of the unit S -P/ -C/ -Z, ALU -P/ E, ES
Wheel guard ABS
Spokeguard PET / PC
Steering cover PVC-foam rubber , TPE
Armrests and calf pads PU-foam
Buckle POM / PA 66
Screws, pins, nuts S -Z/ -N, ES
Wooden parts veneered PU-coating lacquer
Wooden parts laminated PVC
Mains cables ABS, PVC
Enclosures for electrical components ABS, PVC
Synthetic leather covers PVC-compound, BW/P knitted fabric, PU
Textile covers P, PA
Cushions PU-foam
Belts and straps P, PA
Drive wheels ALU-E / ES / Rubber
Abbreviation Material
S-P Steel, powder-coated*
S-C Steel, chrome-plated
S-Z Steel, galvanised
S-N Steel, nickel-plated
ALU-P Aluminium, powder-coated*
ALU-E Aluminium, anodised
ES Stainless steel
POM Polyoxymethylene
PU Polyurethane
PA Polyamide
PC Polycarbonate
PPolyester
PVC Polyvinyl chloride compound
TPE Thermoplastic elastomers
BW Cotton
PET Polyethylene terephthalate (*) - all substances used for powder coa-
ting are based on epoxy resin/polyester.
15 from 60

1024081_EN_1 Subject to technical changes and printing errors.
Daily cleaning
• It is recommended that all parts of the unit that have been touched by patients and users, as well as all
handles and accessories, are cleaned every day.
• Spilled liquids should be removed as soon as possible. Use of the mobility base is only permitted when the
device is completely dry and clean.
• Wash or replace padded elements as needed.
IMPORTANT Some liquids used in the healthcare sector may cause permanent stains!
Cleaning for a dierent patient
Before the mobility base is used for therapy with a new patient, it must be carefully prepared:
• All hard surfaces the patient might touch shall be cleaned and treated with a disinfectant.
• All covers must be cleaned and treated with a disinfectant (if possible).
IMPORTANT If you use the device frequently for dierent patients, you can purchase replacement
elements from your dealer.
Cleaning for reuse
Before the mobility base is used again, it must be carefully prepared:
• All hard surfaces the patient might touch shall be cleaned and treated with a disinfectant.
• All covers/belts and straps must be cleaned and treated with a disinfectant (if possible).
• When soiled, all covers and available belts and straps shall be cleaned or replaced!
Cleaning/disinfection of solid surfaces
Only the use of detergents and CE-certied disinfectants intended for cleaning medical equipment and
having an optimal pH value of 6.5-8 are permitted.
Cleaning agents and disinfectants may contain isopropanol and ethanol (e.g. INCIDIN® FOAM).
Cleaning of:
• Coated and lacquered metal surfaces
• Coated and lacquered wooden surfaces
• Hard plastic surfaces of star knobs, wing screws and clamp levers
is best done with a soft, dry towel, a slightly damp microbre cloth and lukewarm water (with or without
detergent).
Disinfection of:
• Coated and lacquered metal surfaces
• Coated and lacquered wooden surfaces
• hard plastic surfaces of star knobs, wing screws, clamp levers
is best done with soft paper and microbre cleaning cloths. The disinfectant must not be sprayed onto the
product. Spray a soft cloth and apply the disinfectant to the surfaces.
The device and its accessories must not be sprayed with liquid agents to avoid possible liquid penetration.
To avoid skin irritations or allergic reactions, make sure that no residues of cleaning agents or disinfectants
16 from 60

1024081_EN_1 Subject to technical changes and printing errors.
remain on the surfaces.
Dry the parts thoroughly afterwards.
Synthetic leather covers
The leatherette covers must be disinfected with a CE certied surface disinfectant. The disinfectant must
then be wiped o completely with a damp cloth and the synthetic leather covers must be dried thoroughly
with a microbre cloth.
Alternatively, disinfection can be carried out in a cold fogging system.
Any stains on the synthetic leather covers should be removed as soon as possible with lukewarm water and
a slightly damp cloth, preferably microbre or cotton. For heavier soiling, a warm, mild soapy water solution
and a soft hand brush or sponge can be used. The cleaning process may have to be repeated several times.
Afterwards, wipe away the remains of the cleaning agents with a damp cloth.
Cover cleaning
Here are the laundry symbols to be found on some covers. They depend on the material the covers are made
of.
Symbol Meaning
Machine wash 40°C
Do not bleach
Iron cool
Tumble dry at low heat
17 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.5 Further use
2.5.1 Reuse or reprocessing
The operator/care provider is responsible for reuse or reprocessing.
The Galileo mobility base is basically suitable for reuse, although products in reuse are subject to special
stress.
When the product is used again, it is important that all documents belonging to the unit are handed over to
the next user.
Before each reuse, the product shall be thoroughly inspected.
inspection according to the inspection plan and cleaning according to the following instructions:
Important notes on preparation:
Do not use abrasive agents or cloths
• the powder-coated base frame, the drive wheels, wheel guards and the chrome-plated and pow-
der-coated add-on parts must be cleaned with a CE-certied disinfectant. Dry the parts thoroughly
afterwards. Alternatively, disinfection can also be carried out in a certied cold fogging system.
Lifetime
The lifetime of the product based on its risk assessment is 7 years.
2.5.2 Disposal
The product must not be disposed of with household waste.
The Galileo mobility base requires proper disposal. Please contact your operator/care provider.
Packaging materials shall be separated according to their waste types and disposed of via the waste con-
tainers in accordance with the municipal recycling concept. Waste disposal may vary from municipality to
municipality. For proper disposal, please contact your municipal waste disposal service or the administration
of your place of residence. Observe the disposal regulations of your country.
18 from 60

1024081_EN_1 Subject to technical changes and printing errors.
2.6 Warranty and service
Warranty services refer to defects of the product that are demonstrably due to material or manufacturing
defects.
For the Galileo mobility base, we provide a 3-year guarantee on the frame parts. Such defects will be re-
paired by Rehatec® GmbH free of charge. Cushions, wooden parts, fabrics, castors, gas springs and Bowden
cables are excluded from this guarantee. The manufacturer's warranty conditions apply to the electrical
components.
Rehatec® GmbH cannot accept any further warranty or liability for damage resulting from the following
reasons:
• Non-original spare parts and accessories or those not approved by Rehatec® GmbH
• Changes or interventions in the product not approved by Rehatec® GmbH
• Natural wear and tear or excessive strain
• Any use opposed to the intended purpose or cases of violent damage
• Failure to follow the instructions for use
• Accidental damage
• Repairs or modications carried out by persons who have not been trained or authorised by Rehatec®
GmbH (operators/care providers)
2.6.1 Warranty conditions
• Complaints must be made in writing
• Warranty is void in case of design changes without written approval by Rehatec® GmbH
• Defective or replaced parts are the property of Rehatec® GmbH
• The warranty does not cover accidental damage
• The guarantee refers to new units
2.6.2 Service/ Complaints
Rehatec® GmbH is at your disposal for complaints, enquiries and for further information or orders of acces-
sories and retrottable additional equipment.
19 from 60

1024081_EN_1 Subject to technical changes and printing errors.
3. Product and delivery overview
3.1 Scope of delivery
You may add individual accessories to the Galileo mobility base. Technical data on size and permissible
weight can be found in the table in chapter "5. Technical data".
The base model of the Galileo mobility base is usually delivered fully assembled. To avoid damage during
transport, removable and unattached parts are packed separately in the box.
Base model
The illustration may dier from your product due to the individual options you chose.
Galileo base model
1Base frame (abduction frame)
2Drive wheels (20"; 22"; 24")
3Front castors (4"; 5"; 6"; 7"; 8")
4Brake handle/drum brake
5Seat height adjustment
Seat tilt via gas spring
6Back, height-adjustable and angle-adjustable
7Push bar
8Seat plate
1
2
5
8
7
6
4
3
20 from 60
Table of contents
Other Rehatec Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Seca
Seca 233 manual

Vermeiren
Vermeiren Languedoc instruction manual

Hellenbrand
Hellenbrand Hill-Rom Evolution LI156E Series user manual

MOXTEK
MOXTEK X-ray Sources MOX-HPC150 Max Operation manual

VALES & HILLS BIOMEDICAL TECH
VALES & HILLS BIOMEDICAL TECH iCV200S user manual

Vital Motion
Vital Motion HUMMINGBIRD operating instructions