manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable F1FR-FS56 Manual

Reliable F1FR-FS56 Manual

This manual suits for next models

1

Other Reliable Irrigation System manuals

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable Non-Ferrous Concealer User manual

Reliable

Reliable Non-Ferrous Concealer User manual

Reliable F1FR QREC Manual

Reliable

Reliable F1FR QREC Manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable KFR-CCS User manual

Reliable

Reliable KFR-CCS User manual

Reliable G4A-300 User manual

Reliable

Reliable G4A-300 User manual

Reliable DDX PrePaK Maintenance manual

Reliable

Reliable DDX PrePaK Maintenance manual

Reliable DH80 User manual

Reliable

Reliable DH80 User manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable JL-14 User manual

Reliable

Reliable JL-14 User manual

Reliable F1FR28 Series User manual

Reliable

Reliable F1FR28 Series User manual

Reliable DH56 HSW-PL Manual

Reliable

Reliable DH56 HSW-PL Manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable F1XLH Series User manual

Reliable

Reliable F1XLH Series User manual

Reliable DH80 Manual

Reliable

Reliable DH80 Manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable F1FR-FS56 User manual

Reliable

Reliable F1FR-FS56 User manual

Reliable GFR User manual

Reliable

Reliable GFR User manual

Reliable RFC30 LL User manual

Reliable

Reliable RFC30 LL User manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Popular Irrigation System manuals by other brands

Tyco TY-B Series manual

Tyco

Tyco TY-B Series manual

Toro ZSERIES 570Z brochure

Toro

Toro ZSERIES 570Z brochure

OpenSprinkler OSPi user manual

OpenSprinkler

OpenSprinkler OSPi user manual

EINHELL GE-WW 5537 E Original operating instructions

EINHELL

EINHELL GE-WW 5537 E Original operating instructions

Hunter Institutional Series instructions

Hunter

Hunter Institutional Series instructions

Cellfast 52-305 user manual

Cellfast

Cellfast 52-305 user manual

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product CENTRAL A instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL A instruction manual

Oral Care Technologies Hydro Floss Instructions for use

Oral Care Technologies

Oral Care Technologies Hydro Floss Instructions for use

Tyco Fire Product Gem F892 instruction manual

Tyco Fire Product

Tyco Fire Product Gem F892 instruction manual

Irrigation-Mart KIT-GK100-RV-B quick start guide

Irrigation-Mart

Irrigation-Mart KIT-GK100-RV-B quick start guide

Tyco CC3 manual

Tyco

Tyco CC3 manual

Valley Bender160 owner's manual

Valley

Valley Bender160 owner's manual

Toro 730 Series Installation and service instructions

Toro

Toro 730 Series Installation and service instructions

Eden 97063-EDAMZ quick start guide

Eden

Eden 97063-EDAMZ quick start guide

Netafim NETBEAT user manual

Netafim

Netafim NETBEAT user manual

Tyco Fire Product CENTRAL ELO-231 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ELO-231 instruction manual

Johnson Controls tyco ESFR-17 manual

Johnson Controls

Johnson Controls tyco ESFR-17 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1FR-FS56
Model F1FR-FS42
Quick Response Flat
Spray Sprinklers
Models F1FR-FS56 and F1FR-
FS42 Flat Spray Sprinklers
Types
Standard Pendent
Listings and Approvals
F1FR-FS56
• VdS Schadenverhütung GmbH: Certificate G4080047
• CE Certificate: EC-Certificate of conformity
0786-CPD-40242
F1FR-FS42
• VdS Schadenverhütung GmbH: Certificate G414023
• CE Certificate: Certificate of constancy of performance
0786-CPR-40296
Product Description
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers are
designed for installation in accordance with CEA 4001 or EN
12845 (Automatic Sprinkler Systems - Design, Installation
and Maintenance). The spray pattern created by this sprinkler
makes this an excellent choice for applications with lower
clearance above the suspended open ceilings and in racks.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
with shield are used in applications where there are high and
lower level sprinklers. The shield is to help prevent the lower
level sprinklers from getting wet by the higher level sprinklers.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
utilize a frangible 3.0 mm glass bulb. The glass bulb
consists of an accurately controlled amount of special fluid
hermetically sealed inside of a precisely manufactured glass
capsule. This glass bulb is specially constructed to provide
fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid phase and in the vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied, the
liquid expands forcing the bubble smaller and smaller as the
liquid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distribute
the discharging water.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
temperature rating are identified by the color of the glass
bulb capsule.
Pendent
Pendent with shield
Multilingual document:
Select your language below
Bulletin 022 Rev. A_Multilingual
Bulletin 022 Rev. A_Multilingual
2
022FG01
Models F1FR-FS56 and F1FR-FS42 Quick Response Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler Type
Standard–Pendent (SSP) Deflec-
tors Marked to Indicate Position
K Factor Sprinkler
Height
Approval
Organizations
Sprinkler Identifica-
tion Number (SIN)
US Metric
1/2” (15 mm) Standard Orifice with 1/2” NPT Thread 5.6 80 2.25” (57 mm) VdS RA2214
1/2” (15 mm) Standard Orifice with R
1/2Thread 5.6 80 2.25” (57 mm) VdS RA2214
3/8” (10 mm) Standard Orifice with R
1/2Thread 4.2 57 2.25” (57 mm) VdS RA2215
Pendent
Model F1FR-FS56 with shield
Models F1FR-FS56 and F1FR-FS42 Quick Response Pendent Sprinklers with shield
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identifica-
tion Number (SIN)
US Metric
1/2” (15 mm) 1/2” NPT 5.6 80 2.25” (57 mm) VdS RA2214
1/2” (15 mm) R
1/2” BSPT 5.6 80 2.25” (57 mm) VdS RA2214
3/8” (10 mm) R
1/2” BSPT 4.2 57 2.25 (57 mm) VdS RA2215
Shield Data
Part No. Approvals “A”
Dimension
“B”
Dimension
“C”
Dimension
6999995574 VdS 4
17/32”
(115 mm) 1
15/16”
(49 mm) 9/16” (14 mm)
3
Models F1FR-FS56, F1FR-FS42 Pendent
Sprinklers, F1FR-FS56 and F1FR-FS42
Pendent Sprinklers with shield
Application
Models F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
are used in concealed spaces, suspended open ceiling and
in racks in accordance with CEA 4001 Sprinkler System
Planning) and EN 12845 (Automatic Sprinkler Systems -
Design Installation and Maintenance).
Installation
Models F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
are quick response sprinklers intended for installation as
specified in CEA 4001 and EN 12845. They must also be
installed with the Model D Sprinkler Wrench specifically
designed by Reliable for use with these sprinklers.
When installing Models F1FR-FS56 and F1FR-FS42
Pendent with shield use the Model GFR2 Sprinkler Wrench.
Any other type of wrench may damage these sprinklers.
Note: A leak tight 1/2” NPT sprinkler joint can be obtained
with a torque of 8-18 ft-lb (10.8 - 24.4 N-m). Do not tighten
sprinklers over maximum recommended torque. It may
cause leakage or impairment of the sprinklers.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
- Specify Bulb Size when ordering
6. Sprinkler Finish - Bronze only
Note: When Models F1FR-FS56 and F1FR-FS42 Pendent
Sprinklers with shield are ordered, the sprinklers and shields
are packaged separately.
Maintenance
The Models F1FR-FS56, F1FR-FS42 Pendent, F1FR-
FS56 and F1FR-FS42 Pendent Sprinklers with shield should
be inspected quarterly. Do not clean sprinklers with soap
and water, ammonia or any other cleaning fluid. Remove any
sprinkler which has been painted (other than factory applied)
or damaged in any way. A stock of spare sprinklers should
be maintained to allow quick replacement of damaged or
operated sprinklers. Prior to installation, sprinklers should be
maintained in the original cartons and packaging until used
to minimize the potential for damage to sprinklers that would
cause improper operation or non-operation.
Temperature Ratings:
Classification
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color
°C °F
Ordinary
Ordinary
Intermediate
Intermediate High
57
68
79
93
141
135
155
175
200
286
100 °F (38 °C)
100 °F (38 °C)
150 °F (66 °C)
150 °F (66 °C)
225 °F (107 °C)
Orange
Red
Yellow
Green
Blue
Finish
Sprinkler Shield
Bronze Galvanized
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products
manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable... For Complete Protection
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
• Fire department connection
EG. Printed in U.S.A. 05/14 P/N 9999970360