Rice Lake LaserLight User manual

75936
LaserLight
M-Series and 4-SG LED Remote Displays
Version 2.05
Installation & Operation Manual
®


Contents
1.0 Introduction.................................................................................................................................. 1
1.1 Annunciators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0 Mounting Plate Installation and Setup........................................................................................ 3
2.1 Unpacking and Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Enclosure Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.3 Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.4 Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.4.1 AC Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4.2 Serial Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.4.3 20 mA Current Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.4 RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.5 RS-485 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.6 Reset Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4.7 Communicating with Indicators and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4.8 Decimal Point (7-Segment Display) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.0 Configuration ............................................................................................................................ 10
3.1 Auto-Learn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.2 Manual Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3 Serial Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4 Testing the Remote Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 19
3.4.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4.2 Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4.3 Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4.4 Loop Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.5 Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.6 Demand Print Displaying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.7 Serial Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.7.1 Command Format (7-Segment): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.7.2 Display Message Command Format (Matrix Display): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.7.3 Set or Get the Digital I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.0 Options ....................................................................................................................................... 24
4.1 Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.2 Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.3 Visor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4 Pole Mount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.5 Traffic Light Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.5.1 Dry Contact Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.5.2 Single Switch Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.5.3 Two Switch Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.0 Appendix .................................................................................................................................... 29
5.1 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.2 7-Segment Display Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.3 8- & 12-Character Display Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.4 LaserLight Remote Display Enclosure Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5.5 LaserLight Matrix Display Enclosure Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.6 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
©2008 Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America.
Specifications subject to change without notice. Version 2.05
March 2008
Technical training seminars are available through Rice Lake Weighing Systems.
Course descriptions and dates can be viewed at www.ricelake.com or obtained
by calling 715-234-9171 and asking for the training department.


Introduction 1
About This Manual
This manual is intended for use by service technicians
responsible for installing and servicing the
LaserLight®LED remote display.
Installation procedures are presented in the order
likely to be followed by the installer: pre-installation
setup, configuration, and on-site installation.
Most procedures described in this
manual require work inside the remote
display enclosure. These procedures
are to be performed by qualified
service personnel only.
Authorized distributors and their employees
can view or download this manual from the
Rice Lake Weighing Systems distributor
site at www.ricelake.com.
1.0 Introduction
The LaserLight remote display features a super-bright LED display and non-glare filtered lens for use in a wide
variety of applications. The LaserLight M-Series and LaserLight 4-SG Series are available with a 7-segment,
six-digit display or an 8- or 12-character matrix display. The LaserLight remote display is designed to work with
most digital weight indicators, host computers, and peripherals using 20 mA current loop, RS-232, or RS-485
communications.
The unique IntelliBright™feature uses a photo sensor to read ambient light and automatically adjusts the
LaserLight display between day and night settings.
The display has seven internal buttons and three external buttons to set various parameters. The external buttons
include two for setting the time and date, and one for the learn sequence. The configuration menu is entered via
the setup button and is displayed on the display board panel for easy configuration of the unit.
This manual provides installation and configuration instructions for the display.
Standard Features
The LaserLight 7-segment remote display is available in 4" or 6" digit sizes and the matrix display is available in
2.5" character size with 8 or 12 positions. The LaserLight 4-SG remote display comes in a 4" digit size in a 6"
enclosure size. Both styles use an Auto-Learn function which automatically determines the serial settings and
data format used by the attached indicator.
Additional standard features include:
• Hold displayed weight (demand input)
• Adjustable daylight/night intensity
• Mirror function (weight only)
• Auto-sensing 115/230 VAC power supply
• Mode and unit legends
•Echo
• Traffic light option (4" digit size only)
Optional Features
Optional features of the LaserLight remote display include:
•Temperature
• Time and date
• Field-installable metal visor for all models
• Interchangeable mounting bracket adapter plate
Caution

2LaserLight Remote Display Installation & Operation Manual
1.1 Annunciators
The 7-segment LaserLight remote display uses a set of four high-intensity LED annunciators (shown in
Figure 1-1) and the matrix display uses two positions of the display to show arrows (shown in Figure 1-2) which
provide additional information about the value being displayed:
•Gross and Net annunciators are lit to show whether the displayed weight is a gross or net weight.
•lb, kg annunciators indicate the units associated with the displayed value and represent primary and
secondary units.
• Red, green circle and green arrow annunciators indicate the traffic light state on the display. This feature
applies to only the LaserLight 4-SG.
Figure 1-1. 7-Segment Front Panel Display
Figure 1-2. Matrix Display Front Panel
LED
annunciators
Optional traffic
light display
Arrow
annunciators

Mounting Plate Installation and Setup 3
2.0 Mounting Plate Installation and Setup
The LaserLight remote display can be easily set up and configured once mounted to a wall or pole. This section
describes basic installation, AC wiring, RS-232, RS-485, and 20 mA current loop connections. Once installation
setup is complete, go to Section 3.0 for information on configuring the remote display.
Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when working inside the
enclosure.
This unit uses double pole/neutral fusing which could create an electric shock hazard. Procedures requiring work inside the
remote display must be performed by qualified service personnel only.
The LaserLight has no on/off switch. before opening the unit, ensure the power cord is disconnected from the power outlet.
2.1 Unpacking and Assembly
Immediately after unpacking, visually inspect the LaserLight remote display for damage. If any parts were
damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. The shipping carton
contains the remote display and this manual. The main components of the LaserLight remote display include:
• Painted steel enclosure
• Primary and secondary display boards
•Powersupply
• Mounting panel for the CPU board (located on back of mounting plate)
Figure 2-1. Mounting Plate Showing Primary / Secondary Display Boards (7-Segment Display)
2.2 Enclosure Disassembly
For ease of installation, remove the mounting plate (which includes the primary and secondary display boards)
before installing the LaserLight remote display. This protects the LEDs from unnecessary jarring and makes the
enclosure lighter for installation. Use the following steps to remove the mounting plate from the enclosure.
Use caution when lowering or raising the mounting plate to ensure the LEDs do not touch the enclosure. If
any of the LEDs get bent, they can be straightened back into position.
1. Remove the captive screws located on the bottom of the enclosure. The mounting plate is located on the
inside of the enclosure. It is mounted on a frame that can be held in place by tabs and two pins, (located
on the inside of the enclosure, shown in Figure 2-2).
2. Glide the mounting plate frame downward so that it hangs freely beneath the enclosure.
3. Disconnect the chassis ground wire from the top of the mounting plate mounting frame.
Caution
Warning
Primary display Secondary display
Caution

4LaserLight Remote Display Installation & Operation Manual
4. Disconnect the AC cord assembly from the power supply.
5. Using a slight diagonal twisting motion, slide the mounting plate out from the inside of the enclosure and
set it aside.
Figure 2-2. Tab Pin Assembly on Inside of Remote Display Enclosure
2.3 Wall Mounting
The LaserLight remote display can be mounted to any vertical surface or pole.
Select a site and use installation screws or wall anchors to secure the remote display to a wall. If installing the
remote display on a pole, an optional pole mounting kit is required, this kit fits 4" - 8" poles. Once the enclosure
is secured, slide the mounting plate down so that it is hanging freely from the enclosure with the tabs secured
against the pins. This enables the user to continue wiring the remote display.
2.4 Wiring
The LaserLight remote display provides three cord grips located on the underside of the enclosure for cabling;
one for the power cord (cord supplied), and two for serial communications. The LaserLight remote display is
pre-wired. Ribbon cables connect the CPU board to the digit display boards. An A/C power cord is also supplied.
Only the serial communications cable must be connected. Use the following steps to wire the remote display.
The LaserLight remote display has no on/off switch. Before opening the unit, ensure the power cord is
disconnected from the power outlet.
1. If the remote display is not open, remove the captive screws located on the bottom of the remote display
enclosure.
2. Lower the mounting plate from the inside of the enclosure.
Use caution when lowering or raising the mounting plate to ensure the LEDs do not touch the enclosure sides.
If any of the LEDs get bent, they can be straightened back into position.
3. Loosen the retaining screws located on the front of mounting plate (Figure 2-3). The mounting plate is
hinged on a backplate frame to allow easier access to the AC wiring and the CPU board.
Figure 2-3. Retaining Screw Location
Warning
Caution
Retaining screw

Mounting Plate Installation and Setup 5
2.4.1 AC Wiring
The LaserLight power supply can run on either 115 or 230 VAC. The AC wiring is run through the cord grip to a
3-position AC terminal block bracket on the inside of the enclosure (shown in Figure 2-4). This bracket can be
removed by loosening the two standoffs and lifting it off. It can then be lowered and pulled outside of the
enclosure to ease wiring connections.
Figure 2-4. Inside Enclosure Backplate Diagram
Wiring is run from the terminal block down to the power supply on the back of the mounting plate (location
shown in Figure 2-5).
Figure 2-5. Mounting Plate Diagram with CPU Board and Power Supply Locations
NOTE: Pin 1 is positioned at the left end of the connectors. See Figure 2-5 above.
Refer to the following table for AC wiring connections.
Note: Ensure that a ground wire is attached to the grounding stud located on the enclosure backplate (see Figure 2-4).
3-pin Terminal Block on Enclosure Back To Power Supply
Pin Wire Color Pin
1Hot Brown 1
2Neutral Blue 2
3Ground Green Ground Tab
Table 2-1. AC Wiring Connections
Grounding stud
Power supply
1
GND
VR4
VR3
MX2 MX3
J3
DP3
C1
1
J2
J1
DP2
LO
C5
1
J6
1 1
J4
HCPL4100
HS2
RX1
RESET
VR2
HI
1
U7
1
ISP
1
J7
TX1
TX0
RX0
RX0_20MA
TX0_232
RX0_232
RX0_485 TX0_485
TX1_232
TX1_20MA
RX1_232
RX1_20MA
1
J8
1
J9
VR1
DP1
MX1
HS1
TRIPSET
CPU +5V
TEST
MX3 +5V
TEST
TEST +12V
POWER
SUPPLY
1
1
1
1
1
1
RICE LAKE WEIGHING SYSTEMS
Assembly P/N
Revision
M
D
T
X
I
M
20mA
R
E
C
V
PAS
ACT
PAS
ACT
0
1
2002
KP1
J1 - DIGITAL I/O - FUTURE USE
J2 - FIBER LINK OPTION CARD
J3 - POWER SUPPLY INPUT
J4 - TEMPERATURE PROBE
J5 - LEARN SWITCH
J6 - 20mA SERIAL
J9 - RS-485 SERIAL
CONNECTOR GUIDE
J7 - TIME SET
KP1 - KEYPAD
J5
J8 - RS-232 SERIAL

6LaserLight Remote Display Installation & Operation Manual
2.4.2 Serial Wiring
Serial communications are connected to the CPU board using removable screw terminal plugs on J6, J8 and J9
(see Figure 2-8).
To connect the communications cable to the remote display, do the following:
1. If the enclosure is not open, disconnect power and open the remote display by removing the captive
screws on the bottom of the enclosure and lower the mounting plate.
2. Open the captive retaining screws (Figure 2-6) and flip forward the hinged mounting plate.
Figure 2-6. LED Primary and Secondary Display Boards (7-Segment Display)
3. Loosen the serial cable cord grip and push enough communications cable into the enclosure to allow
attachment to the CPU board.
4. Strip 1/4" (.65 cm) of insulation from the serial cable ends.
5. Make cable connections for RS-232, RS-485, or 20 mA current loop communications as described in
Table 2-2.
6. Remove any excess cable from inside the enclosure. Tighten the serial cable cord grip.
NOTE: If you are experiencing RF Interference, follow the instructions below.
1. Loop the serial wires through the cylindrical ferrite (PN 66730) provided with this manual. See
Figure 2-7 below.
2. Using the plastic cable ties provided, secure the wires to the ferrite and the serial cable to the learn switch
wires to keep ferrite from contacting the CPU board. See Figure 2-7 below.
Figure 2-7. Cylindrical Ferrite Placement
Captive retaining
screw
Cylindrical
ferrite
Plastic cable ties

Mounting Plate Installation and Setup 7
NOTES:
•Terminals J6, J8, and J9 are removable screw terminal plugs.
•Port 0 is used for input only and port 1 is used to drive the next LaserLight Remote Display. See Table 2-2
above.
Connector Pin Assignment Function Port Position
J1 1 Ground
2Digin 0
3Digin 1
4+ 5 Volts
5DigOut 0
6DigOut 1
7Ground
J6 1 20 mA Rx+ Port 0
220 mA Rx– Port 0
320 mA Tx+ Port 1
420 mA Tx– Port 1
J8 1 RS-232 TxD 0 Port 0
2RS-232 TxD 1 Port 1
3RS-232 RxD 0 Port 0
4RS-232 RxD 1 Port 1
5RS-232 SIG GND
6RS-232 SIG GND
J9 1 RS-485 Rx+ Port 0
2RS-485 Rx– Port 0
3RS-485 Tx+ Port 0
4RS-485 Tx– Port 0
Table 2-2. Serial Communications Wiring

8LaserLight Remote Display Installation & Operation Manual
Figure 2-8 shows the LaserLight remote display CPU board.
Figure 2-8. LaserLight Remote Display CPU Board
Port 0 which is connected to the indicator supports three configurations; 20 mA, RS-232, and RS-485
communications. Port 1 which is the Echo port, supports 20 mA and RS-232 communications.
2.4.3 20 mA Current Loop
The 20 mA current loop communication is provided on connector J6 of the CPU board (Figure 2-8,Table 2-2).
Ensure receive jumpers are across RX0, 20 mA and select active or passive switch settings. Remove any unused
jumpers. (Figure 2-9)
2.4.4 RS-232
The RS-232 connection is provided on connector J8 of the CPU board (Figure 2-8,Table 2-2). Ensure the
transmit and receive jumpers are across TX0 232 and RX0 232. (Figure 2-9)
2.4.5 RS-485
The RS-485 connection is provided on connector J9 of the CPU board (Figure 2-8,Table 2-2). Ensure the
transmit and receive jumpers are across TX0 485 and RX0 485. (Figure 2-9)
Figure 2-9. Jumper Pin Locations
VR4
VR3
MX2 MX3
J3
DP3
C1
1
J2
J1
DP2
LO
C5
1
J6
11
J4
HCPL4100
HS2
RX1
RESET
VR2
HI
1
U7
1
ISP
1
J7
TX1
TX0
RX0
RX0_20MA
TX0_232
RX0_232
RX0_485 TX0_485
TX1_232
TX1_20MA
RX1_232
RX1_20MA
1
J8
1
J9
VR1
DP1
MX1
HS1
TRIPSET
CPU +5V
TEST
MX3 +5V
TEST
TEST +12V
POWER
SUPPLY
1
1
1
1
1
1
RICE LAKE WEIGHING SYSTEMS
Assembly P/N
Revision
M
D
T
X
I
M
20mA
R
E
C
V
PAS
ACT
PAS
ACT
0
1
2002
KP1
J1 - DIGITAL I/O - FUTURE USE
J2 - FIBER LINK OPTION CARD
J3 - POWER SUPPLY INPUT
J4 - TEMPERATURE PROBE
J5 - LEARN SWITCH
J6 - 20mASERIAL
J9 - RS-485 SERIAL
CONNECTOR GUIDE
J7 - TIME SET
KP1 - KEYPAD
J5
J8 - RS-232 SERIAL
20 mA
Active/Passive
Port 0 Jumpers
Signal LED’s
Signal LED’s
Reset Switch
Port 1
Jumpers

Mounting Plate Installation and Setup 9
2.4.6 Reset Switch
The reset switch enables a simulated power up reset. It then goes back to normal operation mode. The reset
switch eliminates having to unplug the unit to do a reset. Refer to Figure 2-8 on page 7 for the reset switch
location on the CPU board.
2.4.7 Communicating with Indicators and LEDs
Small LEDs located on the CPU board flash when serial data is received or sent. The transmit indicators flash
when data is being sent out of the port. The receive indicator flashes when the data is received. A steady indicator
on any receive LED reflects a connection with no streaming data. See to Figure 2-9 on page 7 for communication
indicator locations on the CPU board.
2.4.8 Decimal Point (7-Segment Display)
The primary display board has decimal LED’s. These can be changed to commas by moving a jumper located on
the front of the display board shown in Figure 3-2 on page 10.
Ensure that the decimal point/comma jumper is in the proper position on the display board.

10 LaserLight Remote Display Installation & Operation Manual
3.0 Configuration
Once the LaserLight remote display is installed, it may need to be configured if your indicator requires special
settings. This can be done manually and is explained in Section 3.2.
Using Auto-Learn (Section 3.1) simplifies installation by automatically detecting the communications format
and data rate used by the indicator and eliminates the need for configuration.
3.1 Auto-Learn
The LaserLight remote display incorporates a software feature called Auto-Learn. Auto-Learn examines the
serial data stream sent from the attached indicator and attempts to determine the data settings and format used by
the indicator.
Auto-Learn occurs automatically when Port 0 is not locked via software configuration (not locked by default)
(Table 3-5), and the connecting indicator is configured to send continuous (streaming) data. It will also occur
automatically if the currently streamed format changes. LaserLight will Auto-Learn by itself in most cases. Or,
you can force this by pressing the external Auto-Learn button.
Use the following quick steps for Auto-Learn.
1. Open the enclosure per disassembly instructions in Section 2.2 on page 3 and connect the serial
interface.
2. Visually inspect that the Auto-Learn button is connected to J5 on the CPU board (see Figure 3-1 for
plug-in location).
3. Power up the remote display.
4. Momentarily press the Learn button.
5. Use the right and left buttons to shift the displayed data string if the displayed weight is not positioned
with LSD.
NOTES:
• If you are using an indicator with a Toledo T8142 format, follow steps 1 through 5 and then go to SP IND
in the serial menu. Select 1 under special indicators.
• It is recommended to lock Port 0 (see Table 3-5), to eliminate any un-intentional changes from occurring.
3.2 Manual Configuration
To begin configuration, open the enclosure (See Section 2.2 on page 3 for enclosure disassembly instructions), to
access the CPU board (Figure 3-1) and digit display board (Figure 3-2).
Figure 3-1. LaserLight CPU Board
VR4
VR3
MX2 MX3
J3
DP3
C1
1
J2
J1
DP2
LO
C5
1
J6
11
J4
HCPL4100
HS2
RX1
RESET
VR2
HI
1
U7
1
ISP
1
J7
TX1
TX0
RX0
RX0_20MA
TX0_232
RX0_232
RX0_485 TX0_485
TX1_232
TX1_20MA
RX1_232
RX1_20MA
1
J8
1
J9
VR1
DP1
MX1
HS1
TRIPSET
CPU +5V
TEST
MX3 +5V
TEST
TEST +12V
POWER
SUPPLY
1
1
1
1
1
1
RICE LAKE WEIGHING SYSTEMS
Assembly P/N
Revision
M
D
T
X
I
M
20mA
R
E
C
V
PAS
ACT
PAS
ACT
0
1
2002
KP1
J1 - DIGITAL I/O - FUTURE USE
J2 - FIBER LINK OPTION CARD
J3 - POWER SUPPLY INPUT
J4 - TEMPERATURE PROBE
J5 - LEARN SWITCH
J6 - 20mASERIAL
J9 - RS-485 SERIAL
CONNECTOR GUIDE
J7 - TIME SET
KP1 - KEYPAD
J5
J8 - RS-232 SERIAL

Configuration 11
The setup button is located on the secondary display board (Figure 3-2).
Figure 3-2. Setup Button Location on Secondary Display Board (7-Segment Display)
The display board is mounted on a hinged mounting plate to allow for easy access to the CPU board. Press the
SETUP button (shown in Figure 3-2) to access main menu configuration parameters.
Main menu parameters include:
• Configuration
• Serial communications
• Test
• Version
The LaserLight remote display can be configured and displayed using a series of menus accessed using internal
buttons located on the secondary display and shown in Figure 3-3.
Figure 3-3. Configuration Setup Buttons
Use the UP/DOWN, LEFT/RIGHT buttons to navigate through menu items and the ENTER button for setting a
selection.
Jumper position
for decimal point or
comma
Setup button
DOWN
RIGHT
LEFT
UP
SETUP
ENTER

12 LaserLight Remote Display Installation & Operation Manual
Table 3-1 summarizes the functions of each of the main menus and Figure 3-4 illustrates the main menu
selections.
Figure 3-4. LaserLight Main Menu Options
When configuring the indicator attached to the remote display, ensure that the decimal point configuration is
compatible with the remote display. The LaserLight 7-segment remote display allows none, one, or two decimal
places (see Figure 3-2 for jumper positions). The 8- or 12-character matrix displays use one character position for
the decimal point.
Figure 3-5 shows the configuration menu.
Figure 3-5. Configuration Main Menu Choices
Note: With the 8- and 12-character matrix displays some of the labels are not shortened, for example STDSTL in the
7-segment is STAND STILL on the 12-character display.
7-segment
Display Menu
8-Character
Matrix Display
Menu
12-Character
Matrix Display
Menu Menu Function
CONFIG CONFIG CONFIG Configuration. Configures time and date (option), temperature (option),
display brightness, mirroring, and other parameters associated with
configuring the remote display
SERIAL SERIAL SERIAL Serial. Configures serial ports
TEST TEST TEST Test. System hardware tests
VER VERSION VERSION Version. Displays installed software version number
Table 3-1. LaserLight Remote Display Menu Summary
TEST
SERIAL
CONFIG VER
TIM DAT TEMP BRIGHT
ENABLE
Off
On
ISO
USA
Minutes
Hour
FORMAT SET DATE
Month
Day
Year
SUPP 0 MIRROR STDSTL ADDRES MSG TM D TEST RESET
On
Off
C
F DAY
On
Off
Off
On
Off
On 0 - 31
Off
On
CONFIG
SERIAL TEST VER
15 sec
5 sec
30 sec
1 min
5 min
Reset
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
LEARN EN
Off
On NIGHT
TEMP ADJ
+/- 5

Configuration 13
CONFIG Menu
7-Segment Display
Parameter
8-Character Matrix
Display
12-Character matrix
Display
Choices Description
Level 2 Submenus
TIMDAT TIMEDATE TIME/DATE Enabled
Format
Set
Date
To enable time and date
Displays USA or ISO time format
Sets hours/minutes and month/day/year
Can disable date
TEMP TEMP TEMPERATURE F
C
Select Fahrenheit or Celsius
TEMPADJ TEMPADJ DEGREE ADJUST + 5%
- 5%
+/- 5 degrees display. Can add or subtract up to +/- 5
degrees of both Fahrenheit or Celsius
BRIGHT BRIGHT BRIGHTNESS Day
Night
Selects the brightness during day or nightime hours
SUPP O SUPP O SUPPRESS 0 On
Off
Select On to enable the suppression of leading zeros
in a weight.
MIRROR MIRROR MIRROR On
Off
Select On to display LED readout in reverse. The
menu is viewed normally.
STDSTL STD STL STAND STILL On
Off
Select On to enable display updated weight only when
the scale is not in motion.
ADDRES ADDRESS ADDRESS 0through
31
Assign a command address by selecting a number
between 0-31.
MSG TM MSG TIME MESSAGE TIME 5, 15, 30
sec., 1, 5
minutes
Select amount of time a message stays on the remote
display. Time can vary from 5 seconds to 5 minutes. If
no serial command is used, then this parameter is not
used. (7-segment DM command only)
D TEST DSP TEST DISPLAY TEST On
Off
Set this parameter On to enable a countdown display
test on start up.
RESET RESET RESET CONFIG Resets the remote display to default parameters
LEARN EN LEARN EN LEARN EN On
Off
Enable allows weight learn operation. With Learn off,
the unit operates for demand messages.
Table 3-2. Configuration Menu Summary - Level 2

14 LaserLight Remote Display Installation & Operation Manual
3.3 Serial Communications
The LaserLight remote display has two serial ports available:
• Port 0 - Provides communication with the indicator
• Port 1 - Provides echoing OF INDICATOR DATA
There are 15 sub-parameters associated with Port 0 and six sub-parameters associated with Port 1 which are
shown in Figure 3-6 on page 15. See Section 2.4.2 for serial wiring positions.
Parameter Choices Description
Level 3 submenus (TIMDAT Parameter)
ENABLE On
Off
Select On to enable time and date option. Note: You need an additional chip
called a “snap hat.” It is recommended that you disable the time/date feature if
you don’t want this addtional chip. Will display at zero or less weight only.
FORMAT USA
ISO
Displays in either USA or ISO (military time) format
SET HH/MM
MM/DD/YYYY
Sets hour/minutes and month/day/year
DATE On
Off
Select Off to disable the date display if the date and time option is installed. Time
is still displayed.
Brightness (BRIGHT Parameter)
DAY 1-10 Selects the brightness during day. Brightness is set from 1-10 or 10 to 100% of
the full brightness. IntelliBright averages measured ambient light over a ten
minute time span.
NIGHT 1-5-10Selects the brightness during night. Brightness is set from 1-10 or 10 to 100% of
the full brightness. IntelliBright averages measured ambient light over a ten
minute time span.
Table 3-3. Configuration Menu Summary - Level 3

Configuration 15
Figure 3-6. Serial Menu
PORT0 PORT1
BAUD PARITY DATA
BAUD PARITY DATA
Even
Odd
8
7
None
Even
Odd
None
CONFIG SERIAL TEST VER
HOLD WT LOCK E CHAR LW POS
Off
On
Off
On
LR
CR
FF
ETX
number
between 5-50
STOP
8
7
2
1
LENGTH
number
between 5-75
A -Z
A -Z
GROSSC NETC MOTION
A -Z
A -ZA -Z
SP IND
0
1200
2400
4800
9600
19200
1200
2400
4800
9600
19200
ECHO LOCK
Off
On
On
Off
STOP
2
1
PRIMU SECU
number
between 5-75
1
2
3
4
5

16 LaserLight Remote Display Installation & Operation Manual
Serial Menu
Parameter Choices Description
Level 2 Submenus
Port 0 BAUD
PARITY
DATA BITS
STOP BITS
HOLD WT
LOCK
E CHAR
LW POS
LENGTH
PRIM U
SEC U
GROS C
NET C
MOTION
SP IND
Configure Port 0. See Level 3 submenu parameter descriptions.
Keeps last weight displayed if communication is lost and prevents the remote
display from going into an error condition.
If enabled, prevents the Auto-Learn (Section 3.1) parameter from working
and ensures settings remain currently set.
This feature looks at the last character to determine the end of a packet.
Can select a number between 5 and 50. Is zero indexed and determines last
weight position of the format.
Can select a number between 5 and 75 and determines the length of packet
in the string format.
Select primary unit characters
Select secondary unit characters
Select gross character
Select net character
Select motion status character
Select, decode status, and settings for special indicator type.
0 = none
1 = Toledo 8142 format
PORT 1 BAUD
PARITY
DATA BITS
STOP BITS
ECHO
LOCK
Configure Port 1. See level 3 submenu parameter descriptions.
Disable this to allow echoing between remote display and other devices. Data
settings should be set equal to or greater than device being echoed to.
If disabled, remote display uses same settings as indicator after an
Auto-Learn.
Table 3-4. Serial Communication Menu Summary
Serial Menu
Port 0
Parameter
Choices Description
Level 3 Submenus
7-Segment
Display
Parameters
8-Character
Display
Parameters
12-Character
Display
Parameters
BAUD BAUD BAUD 1200
2400
4800
9600
19200
Baud rate. Selects the transmission speed for Port 0
PARITY PARITY PARITY ODD
EVEN
NONE
Selects the parity of data of Port 0
DATA DATABITS DATA BITS 7
8
Selects the number of data bits of Port 0
Table 3-5. Port 0 Serial Menu
If selected, the
appropriate
annunciator is
lit
This manual suits for next models
1
Table of contents
Other Rice Lake Monitor manuals

Rice Lake
Rice Lake LaserLight3 User manual

Rice Lake
Rice Lake SURVIVOR IQ L Series User manual

Rice Lake
Rice Lake LaserLight3 User manual

Rice Lake
Rice Lake MSI-8000 User manual

Rice Lake
Rice Lake LaserLT-60 User manual

Rice Lake
Rice Lake EL232 XPCD User manual

Rice Lake
Rice Lake LaserLight Series User manual

Rice Lake
Rice Lake IQ plus 710 User manual

Rice Lake
Rice Lake LaserLight2 ConnexLink 167091 User manual

Rice Lake
Rice Lake MSI-8000HD User manual