Note: Touching once on the timer symbol will indicate a number 1 on the display
window. The timer is preset from a minimum of 5 minutes to a maximum of 20
minutes where 1 is equivalent to 5 minutes, 2 is 10 minutes, 3 is 15 minutes and 4 is
20 minutes. If you want to disable this function before the preset time expires, touch
on the increase or decrease symbol to set to 0. Timer will automatically cut off
approximately 5 seconds.
d. After the require time is set, the extractor hood will automatically switch back to the
fan setting set beforehand and the timer symbol orange ring will start flashing.
e. When the preset time has expires flashing will stop approximately 5 seconds later.
To set up clean and fresh function after cooking, set the fan increase/decrease symbol
to 0 on the display window.Turn OFF the perimeter panel LED light panel by touching
and holding the light symbol for approximately 1 second.
Touch and hold the timer symbol for approximately 3 seconds. An audible signal will
sound as an acknowledgement. When the signal tone is activated the function will start
and after approximately 40 seconds all lights will be turn off except for the ON/OFF
symbol orange ring backlight and the timer symbol orange ring flashing.
To disable this function before the preset time expires, touch the ON/OFF symbol, all
symbols will light up. Touch the timer symbol for approximately 3 seconds to disable this
function.
Another alternative to operate this clean and fresh function if there is a need to clean the
air in the room when there is no cooking is to switch ON the extractor hood by touching
on the ON/OFF symbol. Touch and hold the timer symbol for approximately 3 seconds.
An audible signal will sound as an acknowledgement. When the signal tone is activated
the function will start and after approximately 40 seconds all lights will be turn off except
for the ON/OFF symbol orange ring backlight and the timer symbol orange ring flashing.
To disable this function before the preset time expires, touch the ON/OFF symbol, all
symbols will light up. Touch the timer symbol for approximately 3 seconds to disable this
function.
Note: Clean and fresh function is preset to work for the first 5 minutes each hour for 24
hours at fan setting speed 1.
If your extractor hood has been operated for 90 hours a white dot saturation indicator
will flash on the lower right side of your display window to remind you that the metal
grease filter should now be clean if you have not done so.
To reset this function touch and hold the timer symbol for approximately 5 seconds.
If your extractor hood has been operated for 270 hours a white dot saturation indicator
will light up solidly on the lower right side of your display window to remind you that it is
time to change the charcoal/carbon filter if you have not done so. If heavy cooking is
observed or when the charcoal filters is/are noticeably dirty or discoloured, have the
charcoal filters replaced immediately. The charcoal filters are not washable and cannot
be restored.
To reset this function touch and hold the timer symbol for approximately 5 seconds.
Note: The saturation indicator does not apply to the activated carbon filter currently
installed on your extractor hood. Please refer to your plasma filter user manual for the
maintenance and care for the activated carbon filter.